Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹18.6 L+₹93,322.50 (5.28%)Rejected-AOC 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹19.7 L+₹2.0 L (11.4%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 4 | L4₹20.0 L+₹2.3 L (13.2%)Rejected-AOC MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 5 | L5₹20.6 L+₹3.0 L (16.8%)Rejected-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L5 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR REPLACEMENT OF EXTERNAL ELECTRICAL NETWORK LT DISTRIBUTION LINE WITH POLE ACSR CONDUCTOR LT PANEL AND OTHER ALLIED MISC WORK AT OFFERS JCO OR MD ACCN AND SOMNATH LINE AREA AT OTM ACCN MIL STN DHRANGADHRA
2024_MES_664070_1
GE(A)/GNR/TOKEN/33 of 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹46,000
Yes
19 Oct 2024
5 Jul 2024
12 Sept 2024
5 Jul 2024
5 Sept 2024
19 Jul 2024
5 Jul 2024 - 17 Jul 2024
Amount
Taking out sub class burnt bricks from the trenches and stacking at site serviceable /unserviceable bricks for reuse complete all as specified and directed..
Supply and laying sub class old 'B' burnt bricks laid as cable protection cover complete all as specified and directed.
Laying only sub class brunt bricks as cable protection cover all as directed.
Dismantling old unserviceable Steel poles/Rcc poles/struts, any size complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-31 (09 Mtr long) including two coats of bituminous paint internally and externally for the portion embedded in concrete and two coats of aluminium paint over one coat of red oxide primer to external/exposed surfaces complete all as specified and directed . Note:- (i) Excavation/PCC will be measured and paid separately under relevant items (ii) writing letters pole no and figures in white enamel of black Roman, Italic or Indian of 10 cm height including circular back ground with black enamel paint of two coats incl white circular border over steel
Dismantling cross-arms of M.S channel or angle sections etc. complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard and dense soil and getting out complete all as specified and directed..
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5 m but not exceeding 3.00m in depth for foundation of pole, laying of cables etc in hard/dense soil and getting out complete all as specified and directed..
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm complete all as specified and directed..
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed..
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundtion of PCC poles/struts all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundtion of pole/stay assembly etc including necessary form work, all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 6 sqmm x 2 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 10 sqmm x 2 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge. Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 16 sqmm x 2/4 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25/35 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 50 sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 70 sqmm x 3.5core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 95sqmm x 3.5 core with glands, cable protection pipes etc., complete from the trenches/fixed on wall removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items.
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 25 Sqmm x 3.5 core cable obtained vide item No 18 above all as per existing make
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 35 Sqmm x 3.5 core cable obtained vide item No 18 above shall be reused.
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 50 Sqmm x 3.5 core cable obtained vide item No 19 above shall be reused.
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 70 Sqmm x 3.5 core cable obtained vide item No 20 above shall be reused.
Re-Laying only in trenches/fixed on wall (or) passing through pipes/in floors, connecting up testing and commissioning of Serviceable PVC/XLPE , 1100 volts grade, LT UG electric cable of size 95 Sqmm x 3.5 core cable obtained vide item No 21 above shall be reused.
Supplying & laying, XLPE insulated PVC inner sheathed, 6 Sqmm, 2 core, armoured with galvanised steel strip heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete all as specified and directed.
All as per item No 27 above but cable of size 10 sqmm 2 core .
All as per item No 27 above but cable of size 10 sqmm 4 core .
All as per item No 27 above but cable of size 16 sqmm 4 core .
All as per item No 27 above but cable of size 35 sqmm 3.5 core
All as per item No 27 above but cable of size 50 sqmm 3.5 core
All as per item No 27 above but cable of size70 sqmm 3.5 core
All as per item No 27 above but cable of size 95 sqmm 3.5 core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of 25/35 Sqmm 3.5core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of 50 sqmm 3.5 core
Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for cable of 70 /95 sqmm 3.5 core
S&F, in repair, GI pipe 80mm bore, light grade, laid below road / fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as per specified and directed.
Supply and fix LT junction box for street light, FRP type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm (internal) comprising of suitable size Aluminium busbar 3 rows with terminals,1 No bakelite base neutral link and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs all as specified and as directed .
S&F, in repair, FRP insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. including taking down old
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 35mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide prime rincluding taking dowo old complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant including taking dowo old complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete withIP 66 protection complete all as specified and directed.
M&L for ACSR sqirrul type conductor of any size drawn for over head line fixed to insulator with binding wire complete all as specified and as directed.
M&L, in repair, Pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volt grade including taking down unservicebale insulator complete all as specified and directed.
M&L, in repair, shackle type insulator, porcelain vitreous, white, brown or green, 75 mm height, 90 mm dia for working pressure 1100 volt grade including galvanized mild steel straps, 31 x 3 mm washers, insulator GI bolts of 12 mm dia including taking down unservicebale insulator complete all as specified and directed.
Suplying, fabricating & fixing structural mild steel channel, angle, iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners,eye hooks, bolts,pole clamps and back plates including nuts, bolts and washers, welding banding cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. .
Dismantling of old un-serviceable ACSR conductor of any size and make from LT over head line complete all as specified and directed.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth strip of 25x4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 4 pole, 250 Amps, 35/36 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed.
All as per item No 51 above but MCCB of rating 200 Amp, 36 KA breaking capacity, 4 pole complete all as specified and directed. .
All as per item No 51 above but MCCB of rating 160 Amp, 36 KA breaking capacity, 4 pole complete all as specified and directed. .
All as per item No 51 above but MCCB of rating 125 Amp, 36 KA breaking capacity, 4 pole complete all as specified and directed. .
All as per item No 51 above but MCCB of rating 100 Amp, 25 KA breaking capacity, 4 pole complete all as specified and directed. .
All as per item No 51 above but MCCB of rating 63 Amp, 16 KA breaking capacity, 4 pole complete all as specified and directed. .
Disconnecting the existing Unserviceable MCCB, taking out from the panel board and replace by S&F new MCCB 3 pole, 200 Amps, 35 KA breaking capacity suitable for 415 Volt, 50 Hz, 3 phase supply, thermal & adjustable magnetic setting, fixed in existing panel and connecting with existing cable, including nuts bolts and washer etc complete all as specified and directed.
All as per item No 57 above but MCCB of rating 160 Amp, 36 KA breaking capacity, 3 pole complete all as specified and directed.
All as per item No 57 above but MCCB of rating 125 Amp, 25 KA breaking capacity, 3 pole complete all as specified and directed.
Supply, installation, commissioning and testing, feeder piller board, compartment , LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof made out of angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.2 mtr in ground and 0.30 mtr over the ground including excavation & earth work in any type of soil and PCC complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar 200 amps rating of 04 strip having suitable whole with nuts and bolts (ii) MCCB 125 Amps, 04 pole 415 Volt-01 No, (iii) MCCB 63 Amp, 04 pole, 415 Volts-04 Nos (iV) MCB 40 Amp, 02 pole, 230 Volts-02 Nos(v) Digital type multifunctional meter showing A, V, Hz etc with suitable CT ratio -1No (vi) Indicating lamp Neon type for R-Y-B - 3 Nos.
S&F, in repair, shunt capacitor 20 KVAR capacity for improvement of power factor bank,including taking down old complete all as specified and as directed.
S&F, in repair, shunt capacitor 10KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed.
S&F, in repair, shunt capacitor 5 KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed.
M/L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height of 9 mtr and above and carrying and depositing where directed not exceeding 50 mtr. Note : (i) Necessary T & P items arrange by contractor. (ii) While cutting the tree branches the fallen branch damaged the contactor, insulator, pole the contractor should be replaced the said items without any extra cost.(ii) Cutting of tree consider in each span only not no of tree in one span have 10 trees it consider only one span.
S&F, in repair, shunt capacitor 2 KVAR capacity for improvement of power factor bank,,including taking down old complete all as specified and as directed.
M&L for painting of indoor/outdoor LT panel of any size with two coats of synthetic enamel grey colour paint after throughly scrapping/cleaning the rushed portion and fixing the LT panel door properly including welding work if necessary and miscelleneous items complete all as specified and directed by Engr-in-Charge
Shree Krushna Supply Corporation (BID ID -3083437)
ALBA AC AND REF SERVICES (BID ID -3070379)
M/S HARI CONSTRUCTION (BID ID -3076223)
BK CONSTRUCTION (BID ID -3073677)
GITANSH ENGINEERS AND COMPANY (BID ID -3071485)
JYOT ENTERPRIES (BID ID -3074544)
Bhumi Construction (BID ID -3087932)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .