Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.2 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹29.2 L+₹3.5 L (13.5%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹31.4 L+₹5.8 L (22.5%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹35.4 L+₹9.7 L (37.8%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹37.6 L+₹11.9 L (46.4%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
22 Aug 2022, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
MAINTENANCE REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS, FIXTURES, DBS AND SUB MAIN WIRING AT CIRCARS AREA, COMD MESS AREA AND NOI AREA UNDER GE (NB) VISAKHAPATNAM
2022_MES_540817_1
C/8063/22-23/E8 / Token 43 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹99,600
Yes
24 Sept 2022
25 Jul 2022
24 Aug 2022
25 Jul 2022
22 Aug 2022
8 Aug 2022
Amount
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 04 above but for One light point controlled by two Nos two way switch complete ditto.
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 04 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 09 above but for One light point controlled by two Nos two way switch complete ditto
All as per item No. 04 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 09 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
All as per item No. 09 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module,AC 230V, 50HZ, conforming to IS 1293 :2005 (incl all revisons and amendments) complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (ii) Four runs of 10 sqmm and two runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
S & F repairs of single core 1.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 2.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 4 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing point wiring/Sub main wiring complete all as specified and as directed.
S & F repairs of single core 6 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing Sub main wiring complete all as specified and as directed.
S & F repairs of single core 10 Sqmm size cable (nominal area) PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 Volts [ISI marked ] drawn through existing /Sub main wiring complete all as specified and as directed.
S & F sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed. (Make: Havell's Cat No. DHDPUSN020 or equivelant of make as per List of Manufacturer's)
S & F three phase sheet metal enclosure with socket plug top and MCBs having triple pole and nutral enclosure with a three pin and earth plug and socket complete with one triple pole MCB of capacity 32Amp, 415V complete all as specified and as directed. (Make: Havell's Cat No. DHDPUTN030 or equivelant of make as per List of Manufacturer's)
S & F in repairs AC Plug for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F in repairs AC Socket for two pin and earth plug and socket enclosure complete all as specified and as directed.
S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 70 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, TPN, 6 Way, 415V, Double door with IP 43 protection, IK 09 complete all as specified and as diretced complete all as specified and directed. (Make: Legrand cat part No. 5076 71 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 12 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 11 or equivalent make as per List of Manufacturer's)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 8 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 47 or equivelant of make as per List of manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SPN 40 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF040 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB Four pole 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCFPF063 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SPN 63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF063 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB TP, 63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed (Make :Havell's Cat part No. DHMGCTPF063 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB TP, 63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed (Make :Havell's Cat part No. DHMGCTPF063 or equivelant of make as perList of manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 3 Pole, 63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 03 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 15 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 05 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 17 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB enclosure suitable for 3 module, 3P MCCB of 63-100 Amps capacity as per site requirement complete and making good disturbed surfaces complete all as specified and as directed.
S & F in repairs MCCB enclosure suitable for 3 module, 4P MCCB of 100-250 Amps capacity as per site requirement complete and making good disturbed surfaces complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole two way 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 16 amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal with PVC rectangluar gang box complete all as specified and as directed.
S & F in repair Socket outlet, 2/3 pin, 5 Amps, flush type complete all as specified and as directed.
S & F in repairs Flush type socket outlet 3 pin, 2 in1, 6A/16A, AC 230V complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments) complete all as specified and as directed.
S & F in repairs steped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 1 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 2 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 8 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 12 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 16 module complete all as specified and as directed.
S & F in repairs Modular white cover plate with frame, but 18 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 1/2 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 3 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 6 module complete all as specified and as directed.
S & F in repairs Modular metal flush box, but 8 module complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs LED Drive 36/40 watts as per site requirement complete all as specified and as directed.
S & F in repairs LED Drive 18-24 watts as per site requirement complete all as specified and as directed
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 6 Watt, Lumen ≥ 600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LKBP01S006X or equivelant of make as per list of manufacturer)
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 11 Watt, Lumen ≥ 1000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LKBP01S010X or equivelant of make as per list of manufacturer)
S & F in repairs LED tube light fittings, batten type, poly carbonate body, 21 Watt, Lumen ≥ 2000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LKBP01S020X or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings, panel type, white powder coated CRCA body, PC lens, Approx dimensions 2'x2', 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LULTSLS036X or equivelant of make as per list of manufacturer)
S & F in repairs LED light fittings,panel type, white powder coated CRCA body, PC lens, Approx dimensions 1'x4', 35 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,min IP 40 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 10 Minutes), 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LULU4SL033XC or equivelant of make as per list of manufacturer)
S & F in repairs Recess mounted spotlight, 2 Watt, warm white colour with aluminium housing and prismatic diffuser, white finish with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LJPP02R002X or equivelant of make as per list of manufacturer)
S & F in repairs Recess mounted COB light, 3 Watt, swival type, warm white colour with aluminium housing and prismatic diffuser, white finish with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LETS36R003X or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 6 Watt as per the existing cutout, 100-110mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JKL-WHT-LNEP01R006X or equivelant of make as per list of manufacturer)
S & F in repairs LED downlight, Recess mounted round/square, die cast aluminium housing, 12-15 Watt as per the existing cutout, 160-180mm and making flush and smooth with gypsum board, CCT: WW/NW/CW, CRI > 80 Ra, IP 20 rated, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JKL-WHT-LNEP01R012X or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulk Head, 10 Watt, IP 65 rated, with pressure die cast aluminium housing and acrylic diffuser, CCT: WW/NW/CW, CRI > 80 Ra, with open and short circuit protections as per IS: 10322 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. IL-WHT-LBLK02X010X or equivelant of make as per list of manufacturer)
S & F in repairs ceiling mounted COB focus light, 20 Watt, warm white colour with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JUI-BLK-LFCLB1R020XW or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulb, 5 Watts Lumen ≥ 500, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LPRM4KV05B2C or equivelant of make as per list of manufacturer)
S & F in repairs LED Bulb, 9 Watts Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LPRM4KV09B2C or equivelant of make as per list of manufacturer)
S & F in repairs LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 30 Watt, Lumen ≥ 3000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-GRY-LSRT015030XC or equivelant of make as per list of manufacturer)
S & F in repairs LED outdoor Flood light fittings, Min IP 65 rated, High pressure aluminium die cast housing and toughened glass cover, 50 Watt, Lumen ≥ 5000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-GRY-LFRO01S050XC or equivelant of make as per list of manufacturer)
S & F in repairs LED outdoor Flood light fittings, Min IP 66 rated, High pressure aluminium die cast housing and toughened glass cover, 100 Watt, Lumen ≥ 10000, Luminous afficacy ≥ 110 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with external SPD of 10 KV, with open and short circuit protections with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JBI-GRY-LFLDSLM100X or equivelant of make as per list of manufacturer)
S & F in repairs LED outdoor Flood light fittings, Min IP 66 rated, High pressure aluminium die cast housing and toughened glass cover, 200 Watt, Lumen ≥ 20000, Luminous afficacy ≥ 110 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with external SPD of 10 KV, with open and short circuit protections with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. (Make: Jaquar Cat No. JBI-GRY-LFLDSLM200X or equivelant of make as per list of manufacturer)
S & F in repairs LED Bollard light fittings, Min IP 65 rated, aluminium die cast housing, frosted Polycarbonate diffuser, Matt grey finish, warm white colour, Wattage 16x0.5 Watt, with open and short circuit protections with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed. (Make: Jaquar Cat No. JQM-GRY-LBLD03R108XW or equivelant of make as per list of manufacturer)
S & F in repairs LED Strip light, 12V, 24W, Indoor type, colour: cool white/Natural white/red/green/blue, Luminous efficacy > 90 Lum/Watt and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LJNS02S012X or equivelant of make as per list of manufacturer)
S & F in repairs LED drive, 12V DC, 2A suitable for strip lights and connecting up complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LSTD02A012V or equivelant of make as per list of manufacturer)
S & F in repairs LED tube rod, T8, 20 Watt, polycarbonate diffuser, 1200mm length, CCT: WW/CW complete all as specified and directed. (Make: Jaquar Cat No. JRA-WHT-LTBL01X010XC or equivelant of make as per list of manufacturer)
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 10"x8" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 6"x4" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F in repairs Rigid non-metalic PVC conduit (32mm dia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F in repair aluminium thimble/ Spreaders, suitable for cable size upto 50 Sqmm complete all as specified and as directed.
Supply and laying cable PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of size 25 Sqmm 4 core including taking out old one complete all as specified and directed.
Supply and laying cable PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of size 35 Sqmm 4 core including taking out old one complete all as specified and directed.
Supply and laying cable PVC insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of size 50 Sqmm 4 core including taking out old one complete all as specified and directed.
Taking down ceiling fan / EXHAUST FAN any sweep from the site including servicing, oiling and greasing etc and re-fixing the ceiling fan / exhaust fan of any sweep again at existing site and connecting up including Provn of 0.75 twin core copper FRLS chord wire from ceiling rose to fan and replacement of minor accessories such as clamp, nut, bolts, split pin, rubber bush etc complete all as specified and as directed .
S & F in repair Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge. (Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
M & L for Repairs to Panel board indoor type sheet metal approximate size (8 x1.5 x 1.5 Feet's) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws metal screws and painting the complete body with two coat of synthetic enamel paint over a coat of Zinc chrome primer and marking the Qtr No, Panel Board No in front side and all as specified and as directed
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs UPVC cable trunking casing and capping of size 75x75mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F in repairs UPVC cable trunking casing and capping of size 100x100mm including cover, bends, elbow, coupler, tees, internal and external bends, arranging existing cables/copper refrigerator pipe etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F LED tube light fittings, batten type, poly carbonate body, 21 Watt, Lumen ≥ 2000, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, THD ≤ 20% & PF ≥0.9, over voltage protection withstand upto 360 (for 2 Hrs) with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Jaquar Cat No. JQM-WHT-LKBP01S020X or equivelant of make as per list of manufacturer)
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated soils exc 250 m but n. exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
SREE DURGA INFOTECH
AARAV POWER CONTROLS
NIKESH ENTERPRISES
DELTA CONSTRUCTIONS
SAI SREENIVASA ENGINEERING
VARADHI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .