Tender Value
₹240.6 Cr
EMD Value
₹1 Cr
Closing Date
20 Mar 2026, 4:00 pmClosed
Yes (up to 4 members)
Two Packet System
EPC [ Single Stage ]
Yes
20/01/2026 11:00
Lowest to Highest
180 days
Expenditure
Capital (Works)
RAIPUR
13 conditions · 2 needing a document upload
Please refer Para 2.2.2 of RFP: "Eligibility & Qualification requirements of Bidder" for the financial eligibility criteria / financial capacity.
Please refer Para 2.2.2 of RFP: "Eligibility & Qualification requirements of Bidder" for the technical eligibility criteria/ Technical Capacity.
8 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suomoto post tender letters of the tenders shall be treated as NULL & Void
It is responsibility of the tenderer that they ensure to see any corrigendum of the tenderer to check the corrigendum on the IREPS website from time to time.
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under.
After opening of the tender, any document pertaining to the constitution of Sole Proprietorship Firm / Partnership Firm / Registered Company/ Registered Trust / Registered Society / HUF etc. shall be neither asked nor considered, if submitted. Further, no suo moto cognizance of any document available in public domain (i.e., on internet etc.) or in Railway's record/office files etc. will be taken for consideration of the tender, if no such mention is available in tender offer submitted.
EPC-Replacement of Panel interlocking installations with Electronic interlocking installations at C-Cabin, D-Cabin, E-Cabin, P-Cabin, Freight Maintenance Yard, Bhilai Exchange Yard, Tilda and Baikunth stations along with associated S&T, Civil & Electrical works in Raipur Division of SECR
EPC-08-SNT-Proj-R-25
EPC-08-SNT-Proj-R-25
Open
Works - General
24 Months
Bilaspur, Chhattisgarh
₹0
₹1 Cr
20 Mar 2026
11 Dec 2025
6 Mar 2026
20 Jan 2026
58 items across 6 schedules · ₹43,83,25,786.3 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of electric fan with BLDC motor, 1200 mm sweep, 26-28 watt, 5 star rating with remote having 2 years warranty. Inspection by Authority Engineer. | Numbers | 300.00 | 2,367 | 7,10,100 |
| 2 | Supply of 20W LED 4' tube light fitting with tube and all its standard accessories. Inspection by Authority Engineer. | Numbers | 1200.00 | 459 | 5,50,800 |
| 3 | Supply of Bulk head fitting with glass dome, wire guard & 5W LED lamp and all its standard accessories. Inspection by Authority Engineer. | Numbers | 300.00 | 756 | 2,26,800 |
| 4 | Supply of 5W LED retrofit lamp B22 16 83 Numbers 93.33 At Par 7746.67 holder base with polycarbonate body and aluminum heat sink. Inspection by Authority Engineer. | Numbers | 675.00 | 118 | 79,650 |
| 5 | Supply of exhaust fan of 300 mm sweep complete with heavy duty gravity flap (self open & close shutter) and all accessories to work on 230 Volts AC supply. (Crompton, Usha, Bajaj, Havells, Khaitan, Anchor or Surya make. Inspection by Authority Engineer. | Numbers | 105.00 | 1,524 | 1,60,020 |
| 6 | Supply of 25W LED outdoor LED street light with complete fitting & all its standard accessories, comprises of pressure die cast aluminium housing powder coated in graphite grey and toughened glass. Inspection by Authority Engineer. | Numbers | 80.00 | 2,592 | 2,07,360 |
| 7 | Supply of 5 pin modular socket outlet with switch of 6 Amps capacity & 250V grade complete with accessories. (ABB, Havells, Wipro, Anchor, HPL or any other make that confirms to respective IS). 230V. Inspection by Authority Engineer. | Numbers | 465.00 | 147 | 68,355 |
| 8 | Supply of 5 pin modular socket outlet with switch of 16 Amps capacity & 250V grade complete with accessories. (ABB, Havells, Wipro, Anchor, HPL or any other make that confirms to respective IS). Inspection by Authority Engineer. | Numbers | 482.00 | 225 | 1,08,450 |
| 9 | "Supply & installation of RJ 45 modular connectors. Inspection by Authority Engineer. | Numbers | 248.00 | 9 | 2,232 |
| 10 | Supply, Transportation & Installation of Split AC, godrej Cooling Only 2 Ton 5 Star (ISEER value from >=5 to <=5.5) Inverter AC Variable Speed Wall Mount Split AC Split AC with inverter compressor, Noise Level 48 dB or better R32 green AC, Condenser Coil: Copper coil, Dust filter, Input Voltage 230 VAC, Included Components 1 Indoor Unit, 1 Outdoor Unit, 1 Remote Control, User manual, Copper wire/ Interconnecting pipe. Brand: godrej/Daikin/Blue Star/Voltas/LG/Samsung or similar. Inspection by Authority Engineer. | Numbers | 76.00 | 49,403 | 37,54,628 |
| 11 | Supply, Transportation & Installation of Heavy Duty AC Stand/Heavy Duty Air Conditioner Outdoor Unit Mounting Bracket. Inspection by Authority Engineer. | Numbers | 76.00 | 494 | 37,544 |
| 12 | Supply of MCB -16A D.P.9KA. with metallic housing. Inspection by Authority Engineer. | Numbers | 288.00 | 491 | 1,41,408 |
| 13 | Supply of DP MCB 32 A MCB complete with sheet steel enclosure , powder painted. Inspection by Authority Engineer. | Numbers | 248.00 | 648 | 1,60,704 |
| 14 | supply of wall mounted 4 way metallic sub distribution board with 04 Nos 250V,16A SP MCB, busbar, neutral and earthing arrangement etc. Inspection by Authority Engineer. | Numbers | 69.00 | 1,290 | 89,010 |
| 15 | Supply of JB of 200 x 150 x 80 mm with Hylam sheet. Inspection by Authority Engineer. | Numbers | 129.00 | 872 | 1,12,488 |
| 16 | Supply of MS distribution box of size 200 x 200 x 120 mm with 2 Nos suitable size aluminium busbar arrangement of 100 Amps capacity. Inspection by Authority Engineer. | Numbers | 69.00 | 1,336 | 92,184 |
| 17 | Supply of street light junction box 150x150x120 mm size with 1 no. 6A HRC fuse with base and 1 no. TPN terminal block stud type suitable for 25sqmm cable. Inspection by Authority Engineer. | Numbers | 46.00 | 1,820 | 83,720 |
| 18 | Supply of 2-Pole structure complete with AB switches, DO Fuse, LA & arrangement etc. Inspection by Authority Engineer. | Set | 46.00 | 41,743 | 19,20,178 |
| 19 | Fabrication and erection of 2-Pole structure complete with AB switches, DO Fuse, LA & arrangement (with all required materials) | Set | 46.00 | 9,809 | 4,51,214 |
| 20 | Supply of 2 HP single phase submersible pump. Inspection by Authority Engineer. | Set | 8.00 | 25,361 | 2,02,888 |
| 21 | Supply of 2 HP Starters Control Panel for Submersible Pump. Inspection by Authority Engineer. | Numbers | 8.00 | 3,481 | 27,848 |
| 22 | Supply of Submersible cable 3 core PVC insulated Flat with copper conductor 6 sq mm size. Inspection by Authority Engineer. | Metre | 3200.00 | 265 | 8,48,000 |
| 23 | Installation of submersible pumps & control panel supplied. | Numbers | 8.00 | 1,150 | 9,200 |
| 24 | Supply & installation of New Universal RO water purification system with inbuilt water cooler. as per attached specification. Inspection by Authority Engineer. | Numbers | 8.00 | 52,700 | 4,21,600 |
| 25 | Supply of 3 source Auto changeover panel 150 Amps. Capacity as per RDSO specification No. TI/SPC/PSI/CLS/0020 and RDSO specification No. TI/SPC/PSI/CLS/0023. Inspection by Authority Engineer. | Numbers | 8.00 | 71,507 | 5,72,056 |
| 26 | Installation and commissioning of Automatic changeover for CLS panel as per details in Annexure A. | Numbers | 8.00 | 254 | 2,032 |
| 27 | Fixing of LED tube light, bulkhead, fitting | Numbers | 1200.00 | 11.7 | 14,040 |
| 28 | Fixing & connecting of ceiling fan. | Numbers | 300.00 | 13.5 | 4,050 |
| 29 | Fixing, wiring & testing of outdoor LED fitting with short arm fixture. | Numbers | 300.00 | 256 | 76,800 |
| 30 | Fixing & connecting of exhaust fan. | Numbers | 105.00 | 24.3 | 2,551.5 |
| 31 | Fixing & connecting of socket outlet with switch of 5 pin, 16/6 Amp capacity & 250 volts | Numbers | 947.00 | 11.7 | 11,079.9 |
| 32 | Fixing & connection of street light junction box | Numbers | 140.00 | 93.22 | 13,050.8 |
| 33 | Fixing & Installation of MS distribution box. | Numbers | 138.00 | 168 | 23,184 |
| 34 | Fixing of Junction Box. | Numbers | 129.00 | 85.5 | 11,029.5 |
| 35 | Erection, testing & commissioning of MCB 16A/32A, DP complete with its metallic enclosure. | Numbers | 536.00 | 46.8 | 25,084.8 |
| 36 | Erection of 10-13 mtr Rail poles (with excavation, installation and all required materials) | Numbers | 46.00 | 4,186 | 1,92,556 |
| 37 | Concealed wiring for lights, exhaust & fans with modular type switches : Concealed wiring with modular type switches 1.5 sq mm single core flexible FRLS copper wire. | Point | 2280.00 | 414 | 9,43,920 |
| 38 | Concealed Wiring for 6/16Amps plug points with Modular board with PVC insulated copper conductor 2.5 sq.mm. size with supply of all materials. | Point | 288.00 | 508 | 1,46,304 |
| 39 | Concealed Wiring for Sub-circuits or similar wiring | Metre | 500.00 | 110 | 55,000 |
| 40 | Concealed wiring for 32 Amps plug points with PVC pipe & PVC insulator copper conductor 4sqmm or more size with supply of all material. | Point | 248.00 | 851 | 2,11,048 |
| 41 | supply of wall mounted 4 way metallic sub distribution board with 04 Nos 250V,16A SP MCB, busbar, neutral and earthing arrangement etc. Inspection by Authority Engineer. | Numbers | 112.00 | 1,290 | 1,44,480 |
| 42 | Erection of Metallic distribution board. | Numbers | 112.00 | 54.9 | 6,148.8 |
| 43 | Plug and socket with MCB 20A metal clad box with metal plug and top. Inspection by Authority Engineer. | Numbers | 140.00 | 1,265 | 1,77,100 |
| 44 | Supply of MS pipe/MS clamp for clamping the light fitting at suitable design and size. Inspection by Authority Engineer. | Kg | 60.00 | 40.5 | 2,430 |
| 45 | Supply of 2x150 sq mm 1100V, LT XLPE PVC armoured Cable with ISI mark | Metre | 40000.00 | 546 | 2,18,40,000 |
| 46 | Electrical Works which are not covered in the above list and as approved by the authority engineer shall be supplied & executed as CPWD DSR E&M (2025). Execution & supply of all items covered under CPWD DSR E&M (2025). The specification and the guideline of CPWD applicable for this schedule. | Lumpsum | 1.00 | 2,24,50,000 | 2,24,50,000 |
| Schedule total | ₹5,73,90,326.3 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SIPFMY_1.pdf
ATTACHMENT
Alt3FeasibilityReport_1.pdf
ATTACHMENT
RevisedAlt2RFP.pdf
ATTACHMENT
Axlecounters.pdf
ATTACHMENT
ChecklistforNewSTInstallation.pdf
ATTACHMENT
ChecklistHQTSAA.pdf
ATTACHMENT
FINALSMKEYSCHEME.pdf
ATTACHMENT
KAVACHREADYEI.pdf
ATTACHMENT
TAN3004EIOnlyHOTSTANDBY.pdf
ATTACHMENT
TAN3007EmbeddedPC.pdf
ATTACHMENT
TAN3008forDistributedEI.pdf
ATTACHMENT
TAN3009minormodificaitoninMLK.pdf
ATTACHMENT
TAN30124.pdf
ATTACHMENT
TAN3012correctionsupplyforVDUMonitor.pdf
ATTACHMENT
TANSecurityV1.pdf
ATTACHMENT
UniformPolicy03-2022onmiscellaneousteststobecarriedoutduringFAT_0001.pdf
ATTACHMENT
TSAAChecklist4.0.pdf
ATTACHMENT
JPODisconnectionReconnectionalterationinRelayroom.pdf
ATTACHMENT
JPOforCarryingoutalterationworkinRelayRoom_3.pdf
ATTACHMENT
JPORBSafeworkinginRelayRoom.pdf
ATTACHMENT
JPORevisedSECRforRelayRoomOpening.pdf
ATTACHMENT
JPOwithPROJPROCEDUREORDERWITHPROJECT.pdf
ATTACHMENT
NIGuidlineRailwayboard.pdf
ATTACHMENT
SignalalterationSECRguidline.pdf
ATTACHMENT
Earthingandbonding.pdf
ATTACHMENT
TentativeKAVACHTOWERLOCATION.pdf
ATTACHMENT
InspectionofDC-DCconverterusedinEIsystem..pdf
ATTACHMENT
PamphletonPrecautionsinlayingofOFCcables.pdf
ATTACHMENT
Replytoquerrymerge.pdf
ATTACHMENT
TentativeBuildingLocationPlan_compressed.pdf
ATTACHMENT
SIPBIAExYard.pdf
ATTACHMENT
Alt3EPCAgreement.pdf
ATTACHMENT
SIPD-CAB.pdf
ATTACHMENT
SIPBKTH.pdf
ATTACHMENT
SIPC-CAB.pdf
ATTACHMENT
Replyof2ndPrebid_1.pdf
ATTACHMENT
SIPTLD.pdf
ATTACHMENT
SIPP-CAB.pdf
ATTACHMENT
SIPECabin.pdf
ATTACHMENT
RDSO-CableDuctDocument.pdf
ATTACHMENT
2024-09-02-Modifiedpointdetectionletter29_08_24.pdf
ATTACHMENT
Policycircular01_2022policyonELDInstallationMaintenancePractice.pdf
ATTACHMENT
EnclosureVInstallationPractices3.pdf
ATTACHMENT
OtherDrawingsforExecution.pdf
ATTACHMENT
PolicyCircular06_2022ImplementationofstandardizationofstandardcircuitissuedbyRDSO.pdf
ATTACHMENT
Procedureorder.pdf
ATTACHMENT
EnclosreVInstalationPractices1.pdf
ATTACHMENT
TANAFDAS3009V1.pdf
ATTACHMENT
TypicalarrangementofIPSatCentreorGoomtyforDistributedEIwithDualVDU.PDF
ATTACHMENT
79-23TypicalforsteelappratuscaselargedrawingL.B..pdf
ATTACHMENT
81_2024-TypicalofVDULayout.pdf
ATTACHMENT
Modifiedpointdetectioncircuitwithpolicyguideline.pdf
ATTACHMENT
Policy01-2021-StandardisationofFuseratinginallSignallightingcircuits.pdf
ATTACHMENT
Policy02-2021-Standardisationoflocationofvariousmaintenance.pdf
ATTACHMENT
POLICYCIRCULARFORUSEOFPPTCTYPEFUSE.PDF
ATTACHMENT
Policycircular01_2022policyonELDInstallationApplicationMaintenancePractice.pdf
ATTACHMENT
Policycircular01_2024GuidelinesforprovisionofAxlecountertracksections.pdf
ATTACHMENT
PolicyCircular02_2025_SECRGuidelineforinstallationofstandbyAxlecounter.pdf
ATTACHMENT
PolicyCircular03_2025_JointCheckingofPCCL.pdf
ATTACHMENT
Policycircular04-2022onuniformuseof110VACoperatedliftingbarrieroverSECR.pdf
ATTACHMENT
PolicyCircular04_2025_toeliminatehazardofpointpositionnotcorresponding.pdf
ATTACHMENT
Policycircular05_2025Modifiedpointdetectioncircuit.pdf
ATTACHMENT
policycircular07_2020standardizationofoutdoorcables.pdf
ATTACHMENT
Policycircular09_2020UseofQBCA1RelaysforpointoperationinEI.pdf
ATTACHMENT
PolicyCircularno7_20256QuadELD.pdf
ATTACHMENT
CompletiondrawingpolicySECR.pdf
ATTACHMENT
CriticalitemRDSOinspection.pdf
ATTACHMENT
Guidelinesfordrillingholesintrack.pdf
ATTACHMENT
policyforsubmissiondrgINCLUDINGRINGFOLDER.pdf
ATTACHMENT
PowersupplytodataloggerfromIPS.pdf
ATTACHMENT
PrecommissioningchecklistPCCLSECRpolicy.pdf
ATTACHMENT
WorkneartrackCivildptSECR.pdf
ATTACHMENT
WritingworkinSigInstallations.pdf
ATTACHMENT
48OFCSECRPolicyguideline.pdf
ATTACHMENT
2024-04-24-RDSOLetter-CCTVTAN-Signed.pdf
ATTACHMENT
2025-09-24-SignedTANVer2240925.pdf
ATTACHMENT
CCTVTAN24.04.24.pdf
ATTACHMENT
supplyofmaterialCCTVSecurityOnlySTQC.pdf
ATTACHMENT
T2025-08-07-ANforIPMPLSVer3.0withAmdtNo.1.pdf
ATTACHMENT
TTF_IPMPLS.pdf
ATTACHMENT
TTPforVSSIPMPLSTCCS.pdf
ATTACHMENT
CablelayingpolicySECR.pdf
ATTACHMENT
HandbookonLayingofSignallingcabless.pdf
ATTACHMENT
JPOforearthworknearSTcablesRB.pdf
ATTACHMENT
JPOforearthworknearSTcablesSECR.pdf
ATTACHMENT
Platformutilityductsforcablelaying.pdf
ATTACHMENT
RBTrackcrossingPrecautions03.06.2024.pdf
ATTACHMENT
RDSOGuidelinesCableLaying.pdf
ATTACHMENT
TrackcrossingBS105guidline.pdf
ATTACHMENT
IPS.pdf
ATTACHMENT
OEMcertification.pdf
ATTACHMENT
RDSOapprovedvendoronly.pdf
ATTACHMENT
RDSOletterregapprovalofMsEfftronicsmakeupgradedversionofDataloggerSystem.pdf
ATTACHMENT
SORST2021.pdf
ATTACHMENT
SECRSTDrawings.pdf
ATTACHMENT
TypicalofBuildings.pdf
ATTACHMENT
ApprovedRCCDuctChamber_compressed.pdf
ATTACHMENT
SIPFMY_1.pdf
CORRIGENDUM
SIPBIAExYard.pdf
CORRIGENDUM
RevisedAlt2RFP.pdf
CORRIGENDUM
TentativeKAVACHTOWERLOCATION.pdf
CORRIGENDUM
EPCAgreementwithScheduleG-1_2.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .