| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹31.0 L+₹87,199 (2.90%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended due to not enlisted in cat c(i), Doc to prove eligibility not uploaded on Def Proc Portal. | |
| 4 | Rejected-Technical | - | Rejected-Technical Not recommended due to not enlisted in cat c(i), Doc to prove eligibility not uploaded on Def Proc Portal. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended due to not enlisted in cat c(i), Doc to prove eligibility not uploaded on Def Proc Portal. |
| Sl No | Description | Qty | Unit | fakhrie apostrical L2 | SURESH ELECTRICALS L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, installation and testing Air cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C + 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410 a/R-32 (b) EER- 5 Star Rating (c) Tonnage - 1.5 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments as specified as directed by Engineer-in-Charge. | 14 | Each | 62,500 ₹8,75,000 Lowest | 62,500 ₹8,75,000 Lowest |
| 2.00 | Supply, installation and testing Air cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C + 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410a/R-32 (b) EER- 5 Star Rating (c) Tonnage - 2 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments as specified as directed by Engineer-in-Charge. | 15 | EACH | 90,000 ₹13,50,000 | 81,500 ₹12,22,500 Lowest |
| 2.01Note for Item No 1 & 2 :- The cost of following items deemded to be included in quoted rate. (a) Copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) MS Bracket for outdoor unit duly power coated with fixing arrangement. (c) Making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall. (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) PVC round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) Taking down of existing AC and deposited to E/M store yard without any damage. | |||||
| 3.00 | Supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180V to 250V without voltage stabilzed at 230V with accuracy of (+) 2.5% and capacity 4 KVA as specified as directed by Engineer-in-Charge. | 14 | EACH | 3,100 ₹43,400 | 2,900 ₹40,600 Lowest |
| 4.00 | Supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180V to 250V without voltage stabilzed at 230V with accuracy of (+) 2.5% and capacity 5 KVA as specified as directed by Engineer-in-Charge. | 15 | Each | 4,000 ₹60,000 Lowest | 4,100 ₹61,500 |
| 5.00 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by Engr-in-charge.
Note: 2 Runs of main copper conductor, one run earth wire and PVC Casing capping will be measured as one running meter for payment. | 120 | Running Metre | 450 ₹54,000 | 230 ₹27,600 Lowest |
| 6.00 | S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position all as specified as directed by Engineer-in-Charge. | 29 | Each | 610 ₹17,690 Lowest | 650 ₹18,850 |
| 7.00 | Supply, installation, commissioning and testing in replacement of loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both class A and class B wiring complete as specified and as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD | 1 | EACH | 26,500 ₹26,500 Lowest | 26,500 ₹26,500 Lowest |
| 8.00 | Supply, installation, commissioning and testing in replacement of Addressable Smoke detector with base with Binary coded address setting. Dual Led's for 360 visibilty. Sleek low-profile housing design. Regular 100mm base. IP rating: Ip-42 complete all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/ CEASEFIRE INDUSTRIES PVT LTD | 110 | EACH | 3,000 ₹3,30,000 Lowest | 3,200 ₹3,52,000 |
| 9.00 | Supply, installation, commissioning and testing in replacement of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating complete all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD | 2 | EACH | 5,095 ₹10,190 Lowest | 5,600 ₹11,200 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
29 Jul 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
SPECIAL REPAIRS REPLACEMENT TO E/M EQUIPMENTS AND INFRASTRUCTURE AT AF STN JAMNAGAR UNDER GE (AF) JAMNAGAR NO 1
2025_MES_719201_1
8327/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Jamnagar No 1
₹58,000
Yes
8 Oct 2025
8 Jul 2025
30 Jul 2025
8 Jul 2025
29 Jul 2025
22 Jul 2025
Amount
Supply, installation and testing Air cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C + 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410 a/R-32 (b) EER- 5 Star Rating (c) Tonnage - 1.5 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments as specified as directed by Engineer-in-Charge.
Supply, installation and testing Air cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (22 Deg C + 3 in cooling mode) Air conditoner will have following conditons :- (a) Refrigerant - R-410a/R-32 (b) EER- 5 Star Rating (c) Tonnage - 2 TR (d) Indoor Noise level - Not more than 40 Db (e) Filter - As recommended by OEM (f) Remote - As recommended by OEM including 02 Nos remote bty (g) Temp display, turbo mode and auto swing facility All specification will be as per IS-1391 (Part 2) and latest amendments as specified as directed by Engineer-in-Charge.
Note for Item No 1 & 2 :- The cost of following items deemded to be included in quoted rate. (a) Copper pipe duly insulated between indoor/outdoor unit upto lenght 10mtr for each unit (b) MS Bracket for outdoor unit duly power coated with fixing arrangement. (c) Making of hole in walls including civil work , sleeves and making good to the disturbed surface/wall. (d) Testing and commissioning of the Air conditioner to the entire satisfaction of Engineer in Charge (e) PVC round sheathed copper cable of suitable size for connecting indoor and outdoor unit upto supply point as per site requirement (f) Taking down of existing AC and deposited to E/M store yard without any damage.
Supply and installation of voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input varioution between 180V to 250V without voltage stabilzed at 230V with accuracy of (+) 2.5% and capacity 4 KVA as specified as directed by Engineer-in-Charge.
Supply and installed voltage stabilzer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 180V to 250V without voltage stabilzed at 230V with accuracy of (+) 2.5% and capacity 5 KVA as specified as directed by Engineer-in-Charge.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm each, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC casing capping with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.00 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete all as specified and as directed by Engr-in-charge. Note: 2 Runs of main copper conductor, one run earth wire and PVC Casing capping will be measured as one running meter for payment.
S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position all as specified as directed by Engineer-in-Charge.
Supply, installation, commissioning and testing in replacement of loop Card having 254 devices of both detectors and modules in a single line circuit, SLC supports both class A and class B wiring complete as specified and as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply, installation, commissioning and testing in replacement of Addressable Smoke detector with base with Binary coded address setting. Dual Led's for 360 visibilty. Sleek low-profile housing design. Regular 100mm base. IP rating: Ip-42 complete all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/ CEASEFIRE INDUSTRIES PVT LTD
Supply, installation, commissioning and testing in replacement of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating complete all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply, installation, commissioning and testing in replacement of conventional type Horn wall mounted type rated at 100 dBA@ 1m for audible annunciation complete all as specified as directed by Engineer-in-Charge. - Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD Note:- Need to connect with sounder as External power supply required
Supply, installation, commissioning and testing in replacement of fault isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected complete as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/ CEASEFIRE INDUSTRIES PVT LTD.
Supply, installation, commissioning and testing in replacement of Addressable Control Module for monitoring the field devices. Binary coding setting Approval UL listed complete all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/ CEASEFIRE INDUSTRIES PVT LTD.
S&F in replacement of Batteries DC, 12V, 7 AH, lead acid duly initial charged complete all as specified as directed by Engineer-in-Charge. Make: Exide and Amaron
M&L for Checking, inspecting and finding of faults in looping, siren, wiring, panel working of existing fire alarm system by OEM engineers at AF stn Jamnagar GE(AF) No1 and rectification of defects incluing Control electrical wiring connected to fire alarm sytem including smoke detector/sprinklers/modules etc complete all as specified as directed by Engineer-in-Charge.
Supply and fixing in replacment of armoured cable 1.5sqmm 2 core to be fixed on wall/cable Tray including all fittings required for connection and fixing all as specified and directed by Engineer in charge
Dismantling of smoke detector from site, cleaning and examining for serviceability and reinstallation as per existing location and testing of smoke detector all as specified as directed by Engineer-in-Charge.
Supply, installation, commissioning and testing in replacement of Analogue Addressable Fire Alarm Control Panel including detector wise configuration facility 200 Event storage with Real Time Clock, upto 192 grouping facility, Pre Alarm Action, Programmable Detector sensivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 characters LCD display 4 numbers of loop card and 254 devices in any combination per loop. Day / Night mode facility. USB 2.0 interface for PC connectivity. Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220 VAC+10% - 15%, 60/50 Hz. Standby Power 24V DC (2Nos. of 12V 40Ah Max, built in for 12Ah) Sealed Lead acid battery operation condition operation temperature 0 - 49º C / 32 - 120º F Relative Humidity 93 ± 2% RH (Non-condensing) at 32 ± 2º C /90 ± 3º F. Make: Ravel Electronics Pvt Ltd. / Honey Well / Ceasefire Industries Pvt. Ltd all as specified as directed by Engineer-in-Charge. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD
Supply and fixing in replacement of stove enamelled black MS conduit 20mm dia ISI marked on ceiling or recessed as required & repairing & making good the same disturbed surfaces complete all as specified as directed by Engineer-in-Charge.
Supply and fixing in replacement of PVC insulated, PVC sheathed single core multistranded copper conductor cable of size 1.5 Sqmm FRLS all as specified and directed by Engineer-in-Charge.
Supply and fix of MCCBs 250 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, adjustable thermal and adjustable magnetic setting type, fixed in existing panel & connecting complete all as specified as directed by Engineer-in-Charge.
Supply & laying LT cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core fixed on wall and connecting and testing etc complete all as specified as directed by Engineer-in-Charge.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. including making good the disturbed surfaces complete all as specified as directed by Engineer-in-Charge.
M&L point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic conduit 19/20 mm dia, medium duty, ISI Marked to be fixed on wall and terminated in modular pvc box ,modular cover plate, modular fittings etc including 2.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch complete including repairing the disturbed surfaces in CM 1:3 and finishing the surface as per existing treatment if required all as specified as directed by Engineer-in-Charge.
Supply and fixing of modular Socket 6A/16A - 2/3 pin combined 2 module all as as specified as directed by Engineer-in-Charge.
Supply and fixing of Modular switch 1 way 16A, 1 module all as specified as directed by Engineer-in-Charge.
fakhrie apostrical (BID ID -3375035)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .