Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.6 LAccepted-AOC DOOR NO 18 13 3 3RD FLOOR HILL CREST APARTMENTS SEETHAMMADHARA NORTH EXTENSION VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹44.3 L+₹67,210.65 (1.54%)Rejected-Finance D NO 18 13 4 3RD FLOOR HILL CREST APARTMENT SEETHAMADHARA NORTH EXTENSION VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹45.5 L+₹1.9 L (4.32%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹47.5 L+₹3.9 L (8.94%)Rejected-Finance D NO 71 31 96 6 ASRR COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹48.0 L+₹4.4 L (10.1%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
10 May 2024, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
PROVISION OF COMMON TOILETS INCLUDING SEWAGE LINE AND COMPOUND WALL AT NAUSENA BAUGH, PROVISION OF 03 SPLIT (02 TON) FOR THE BRIEFING ROOM IN SUBMARINE SCHOOL INS SATAVAHANA VISAKHAPATNAM
2024_MES_650004_1
C/8312/23-24/E8 / Token 122 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹91,000
Yes
6 Nov 2024
12 Apr 2024
18 May 2024
12 Apr 2024
10 May 2024
26 Apr 2024
Amount
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard/dense soil complete all as specified and directed.
Removing excavated material exc. 5.00 km but n exc. 15 km and depositing where directed complete all as specified and directed
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately)
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter for smooth finished surfaces of concrete complete all as specified and directed.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc smooth finished surfaces of concrete complete all as specified and directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat smooth finished surfaces of concrete complete all as specified and directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat smooth finished surfaces of concrete complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M&L for high strength corrosion resistant Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M&L Brick work with fly ash bricks, bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed
M & L for 10 mm thick, screed bed as in roof in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
M&L for preparation of horizontal or vertical surfaces for water proofing treatment on existing cleaned non accessible RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:- (a) Preparing and cleaning of fully dry surfaces as per IS3067-1966 (b) Applying bitumen primer(85/25 grade)conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Litr and viscosity 70-160 cps shall be applied on the prepared surface. (c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application. The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane.
Supply, laying, connection and testing in repair, 25 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply, laying, connection and testing in repair, 40 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supply and fixing vitreous china (White) wash down water closet pan (pedestal pattern) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (White) and mild steel chromium plated or aluminium hinging device complete all as specified and directed by Engr-in-Charge.
S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed.
S & F, 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed.
S&F PVC waste pipe of bore 32 mm and 900mm long to WHB all as specified complete all as specified and directed.
S & F 15 mm bore, CP Health Faucet with 8mm Dia, 1.0 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed.
S & F 15mm bore, bib taps, 2 way, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15mm bore, bib taps, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 15 mm bore, stop valve, cast copper alloy, chromium plated, fancy type with long shank and cup(conceled type) crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F Vitreous China urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed.
S & F Wash Hand Basin, Vitreous China (flat back or angle back type)/oval shape any size, including cutting for and pinning in ends of brackets or erecting stand of size 550 X 400 complete all as per manufacturer's instructions and as required at site.
S & F in repair 15 mm bore,swan neck pillar taps, brass chromium plated, Single Lever screwed for iron pipe complete all as specified and directed.
Providing and fixing factory made uPVC white colour window /ventilator (half fixed half louvered) of area n.exe 1.00 sqm made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners including stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75mm bore including necessary bracket,clamp etc complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary bracket,clamp etc complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenchs 110mm bore complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe with solvent cement including fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F PVC (SWR) bends any radius with access doors 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius with access doors 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
S & F 75mm bore, PVC (SWR) branch piece,single (single Y) equal or unequal with access door complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) branch piece,single (single Y) equal or unequal complete all as specified and directed.
S & F 75mm bore, PVC (SWR) branch piece,single (single Y) equal or unequal with access door complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) branch piece,single (single Y) equal or unequal with access door complete all as specified and directed.
S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
M & L for granite stone slab (of any type) 18 to 20 mm thick (Table rubbed and polished to smooth mirror finish), machine cut, colour Mexican Red/Ruby Red/Z black/Paerl black etc design/pattern as directed including inlays, borders, margins in two or more colours/shades as in floors, trades of steps, cill cooking platform etc set and bedded and jointed with grey cement slurry and jointed and pointed flush using polymer based cementitious tiling joint filler to match the shade of the Granite slabs complete all as specified and directed. (Note: Single stone slab shall be used for entire length/height of steps, jambs, pillars, window cills, cooking platform etc and joints sahll match with the flooring complete)
S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). (Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges with S S screws shall be paid separately)
S & F 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive trength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body hreaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges with S S screws shall be paid separately) complete all as specified and directed.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
M & L for treating the soil alongwith external perimeter of building at the rate of 2.25 litre of emulsion per meter of the perimeter wall complete all as specified and directed.
M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per Sqm of surface area complete all as specified and directed.
M&L for Non-skid coloured ceramic joint free tiles with tile spacer of minimum 3 mm thickness & in light shade 7 to 8mm thick , area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm in floors set and jointed with epoxy grout and masking tape and pointed in white cement or white cement mixed with colour pigment to match the shade of the tile including 15 mm thick screed bed in cement mortor 1:6 a complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 450 x 350/450 x300 ,7 to 8 mm thick with tile spacer of minimum thickess 3mm ,set and jointed with epoxy grout and masking tape and pointed in white cement or white cement mixed with colour pigment to match the shade of the tile including bedding layer of backing coat 10 mm thick in CM 1:4 complete all as specified and directed. Note : Rate includes for cutting for offsets etc
Supply, hoisted and fixing in position 2000 Ltrs capacity rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings complete all as specified & directed.
S & F 40 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
S & F 20 mm bore, gun metal Gate valves, with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed.
M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for moorum/red bajri filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing/pathway, etc, and finished the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore drain pipes complete all as specified and directed .
S & F 200 mm dia, DWC HDPE pipe, stiffness class SN8, with non smooth external annular corrugated and smooth internal surface (Double wall) for non pressure sewage & drainage application, grade conforming to IS-16098 (Part-II: 2013), in any length, with rubber ring joints, laid in trenches or in floors, etc complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finishing the surface even and fair without using extra cement complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces and finishing the surface even and fair without using extra cemen complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole,drain etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 200 mm bore of pipe complete all as specifieed and directed.
M & L for reinforced cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. complete all as specified and as directed.
Use and waste of Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide for smooth finished surfaces of concrete complete all as specified and directed.
M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate), block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cemen complete all as specified and directed.
S & F mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-450 Gde-E-250 Quality -A complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
M&L for preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS
M & L for conceled Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 89 above but for One 3/5 pin socket outlet 6 amps point on same board complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/ polycarbonate, insolated body complete all as specified and directed.
Supply and fixing of LED Surface mounting general purpose LED Battens in extruded aluminium housing tube light fitting 1x 20Watt with LED Lamp , driver including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No LUMILINEPLUSNEOBS20WLED830SPCSSIND of Havells or equivalent model of make list as given in PS as approved by GE.
Supply and fixing of LED Surface mounting general purpose LED Battens in extruded aluminium housing tube light fitting 1x 10Watt with LED Lamp , driver including connecting up three core1.00sq. mm copper conductor flexible wire/cable complete all as specified. Make : Model No LUMILINEPLUSBS10WLED830SPCSSIND of Havells or equivalent model of make list as given in PS as approved by GE.
Supply and fixing LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in triple optics complete with IP 66 protection with and including 1.5 sqmm weather proof 3 core FRLH grade copper conductor and 32 mm dia( or higher size as per manufacturers recommendation) light grade GI pipe (bend to shape or as per manufacturers recommendation ) bracket 1.5 mtr long complete with MS flat iron clamp (clamps shall be 40 x 5 mm MS flat) nuts, bolts & washers including painting the clamps with two coat of aluminium paint over a coat of red oxide primer and including taking up old light fitting complete all as specified and as directedcomplete all as specified and directed Make:- Havells Cat No ENDURASUNDOWNSL35WLED765PASYBOPC or its equivalent make of Philips / CG
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell's cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer's mentioned in PS)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer's mentioned in PS)
Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's mentioned in PS)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated, unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated, unseathed ,multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated,unseathed, multi stranded FRLSH (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated,unseathed, multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one )
S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed Make : Havells, Model : Ventil Air DS or equivelant of make r equivalent make as per List of Manufacturer's mentioned in PS
S & F stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed.
S&F new generation, IP 65 LED Post Top Lantern 40 Watt, 230 Volts, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, Clear Cover for bright illumination complete with driver and lamp, fixing accessories suitable for pole dia Ø 76 mm and connecting up with suitable copper conductor complete all as specified and directed. Make: Havell's Cat No. RUBYPT40WLED757PSYMTOPC or equivelant of make as per list of manufacturer).
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Supply, installation and testing inverter split AC units indoor/outdoor complete with cordless remote control with inbuilt air ioniser and plasma filter for better indoor air quality, minimum 5 star rating,copper condenser,copper cooling coil and EER 3.2 of capacity 2.0 TR including 2.5 sqmm 4 core flex copper cable connection from indoor to outdoor unit as per site requirement including making holes of required dia on walls and necessary masonry work for making good distrubuted surface and match with the existing colour complete all as specified and directed. Make: Bluestar,Carrier,Voltas,LG, Daikin ,Hitachi,General
S & F voltage stabilizer of capacity 5KVA, single phase, input working voltage 170-270 Volts with output voltage stabilized at 230V, metal body with time delay system, wall mountable, built in thermal overload protection, low & high voltage cut-off protection, micro controller based design complete all as specified and directed. Make: V-Gaurd model no VG-500 or equivalent model of make mentioned in PS
S & F MS stand for mounting outdoor unit of Split Ac of capacity 2.00 Ton complete all as specified and as directed.
S & F SRCD DBOXx (Socket Residual Current Device) with over current protection, double pole,PVC encloser with 20 Amps MCB SP "C"curve complete all as specified and directed. Make: Havell's Cat No.DHDBCDP025202003 or equivelant of make as per list of manufacturer).
M/s Sudersana Traders
K NAGARAJU
SRI RAJA RAJESWARI ENTERPRISES
M B CONSTRUCTIONS
SRI LAKSHMI GANAPATHI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .