Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC AXIS HOUSE PLOT 149 BCD KANDIVALI INDUSTRIAL ESTATE KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹34.7 L | L1 | Accepted-AOC As per tender conditions |
| 2 | Not L-1₹42.4 LRejected-AOC | ₹42.4 L | Not L-1 | Rejected-AOC As per tender conditions |
| 3 | Not L-1₹44.8 LRejected-AOC | ₹44.8 L | Not L-1 | Rejected-AOC As per tender conditions |
| 4 | Not L-1₹47.4 LRejected-AOC 4C PEACE ENCLAVE G S ROAD ULUBARI GUWAHATI ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | ₹47.4 L | Not L-1 | Rejected-AOC As per tender conditions |
| 5 | Not L-1₹54.7 LRejected-AOC | ₹54.7 L | Not L-1 | Rejected-AOC As per tender conditions |
| Sl No | Description | Qty | Unit | JEF Techno Solutions Private Limited L6 | FORTUNE INFRATRADE PVT.LTD. L4 | North Eastern Engineers L2 | WIRE CONSULTANCY L3 | AXIS ELECTRICAL COMPONENTS (I) PVT. LTD. L1 | Roksna India Private Limited L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Fixing of of Vertical AirTermination Solid Aluminium with Base- 10 mm dia and 600 mm long, along with accessories . AirTermination Base tested as per IEC 62561-1 2017 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse Current withstand test: 100 kA of 10/350μs waveform (Ageing & Electrical test) conducted in a sequenced manner & tested in the Govt. accredited laboratory. AirTermination conductor tested as per IEC 62561 - 2 conducted in Govt. accredited Laboratory to meet the requirements of IS/IEC 62305 | 64 | EA | 2,300 ₹1,47,200 | 563 ₹36,032 Lowest | 640 ₹40,960 | 1,100 ₹70,400 | 750 ₹48,000 | 700 ₹44,800 |
| 2.00 | Supply and Fixing of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited laboratory to meet the requirement of IS/IEC 62305 with accessories such as holding clamps, connector etc. | 4,450 | MTR | 345 ₹15,35,250 | 295 ₹13,12,750 | 265 ₹11,79,250 | 260 ₹11,57,000 | 212 ₹9,43,400 Lowest | 333 ₹14,81,850 |
| 3.00 | Supply and Fixing of 8mm dia solid Aluminium Conductor for Down Conductor and tested as per IEC62561- 2 conducted in the Govt. accredited laboratory to meet the requirement of IS/IEC62305 including accessories such as holding clamps, connectors, holders etc. | 2,280 | MTR | 345 ₹7,86,600 | 261 ₹5,95,080 | 310 ₹7,06,800 | 260 ₹5,92,800 | 201 ₹4,58,280 Lowest | 333 ₹7,59,240 |
| 4.00 | Supply and Fixing of TestLink tested as per IEC 62561-12017 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350μs waveform(Ageing & Electrical test ) condcuted in asequenced manner & tested in the Govt. accredited laboratory. | 136 | EA | 1,150 ₹1,56,400 | 325 ₹44,200 | 410 ₹55,760 | 260 ₹35,360 | 231 ₹31,416 Lowest | 455 ₹61,880 |
| 5.00 | Supply and installation of UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod is to be tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467and providing masonry enclosure nwith cover plate having locking arrangement and watering pipe etc.with charcoal/coke and salt etc. | 136 | SET | 12,750 ₹17,34,000 | 8,890 ₹12,09,040 | 8,320 ₹11,31,520 | 8,500 ₹11,56,000 | 6,353 ₹8,64,008 Lowest | 8,970 ₹12,19,920 |
| 6.00 | Supply and fixing of GI Strip of size 25x6 mm thickness from earth electrode direct lyin ground as required with accessories tested and used exclusively for lightning protection earthing system and ring equipotential bonding. | 3,016 | MTR | 525 ₹15,83,400 | 272 ₹8,20,352 | 160 ₹4,82,560 Lowest | 260 ₹7,84,160 | 197 ₹5,94,152 | 355 ₹10,70,680 |
Tender Value
Refer Docs
EMD Value
₹71,800
Closing Date
16 Jan 2026, 2:30 pmClosed
Mrs. Neeta Dutta
Brahmaputra Cracker and Polymer Limited, C and P Department, Administrative Building, PO_Lepetkata, Dist_DIBRUGARH, Assam, Pin Code_786006
Please refer Tender documents.
2025_BCPL_261038_1
BCPL/CNP/LE25W174ND/3617
Open Tender
Miscellaneous Services
Item Rate
240 days
BCPL, Lepetkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹71,800
Yes
BCPL, Administrative Building, Lepetkata
30 May 2026
30 Dec 2025
17 Jan 2026
30 Dec 2025
16 Jan 2026
30 Dec 2025
7 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: BRAHMAPUTRA CRACKER AND POLYMER LIMITED
Name of Work: HIRING OF SERVICES CONTRACT FOR INSTALLATION OF LIGHTNING PROTECTION SYSTEM INCLUDING SUPPLY OF ACCESSORIES AT BCPL TOWNSHIP
Contract No: BCPL/C&P/LE25W174ND/3617
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Service Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency UNIT RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category SAC GST IN % (Select appropriate GST %age from the dropdown list) TOTAL AMOUNT in Rs. P TOTAL AMOUNT INCLUDING GST (Select appropriate GST % in GST column) TOTAL AMOUNT In Words
1 Supply and Fixing of of Vertical AirTermination Solid Aluminium with Base- 10 mm dia and 600 mm long, along with accessories . AirTermination Base tested as per IEC 62561-1 2017 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse Current withstand test: 100 kA of 10/350μs waveform (Ageing & Electrical test) conducted in a sequenced manner & tested in the Govt. accredited laboratory. AirTermination conductor tested as per IEC 62561 - 2 conducted in Govt. accredited Laboratory to meet the requirements of IS/IEC 62305 64 EA Excess(+) Full Conversion INR 18 1 Supply and Fixing of of Vertical AirTermination Solid Aluminium with Base- 10 mm dia and 600 mm long, along with accessories . AirTermination Base tested as per IEC 62561-1 2017 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse Current withstand test: 100 kA of 10/350μs waveform (Ageing & Electrical test) conducted in a sequenced manner & tested in the Govt. accredited laboratory. AirTermination conductor tested as per IEC 62561 - 2 conducted in Govt. accredited Laboratory to meet the requirements of IS/IEC 62305 64 EA
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
RFQ.pdf
Tender Documents • 3.11 MB
BOQ_302000.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .