Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | L1 | Accepted-AOC L | |
| 2 | L2₹15.3 L+₹97,640 (6.81%)Rejected-Finance OFFICE NO 301 VASANTASAKHA PLAZA NARHE PUNE MAHARASHTRA 411041 | PUNE | PUNE | MAHARASHTRA | 411041 | L2 | Rejected-Finance L2 | |
| 3 | L3₹15.8 L+₹1.5 L (10.3%)Rejected-Finance 6 573D BHASKARA BUILDING NADAKKAVU P O UDAYAMPEROOR ERNAKULAM KERALA 682307 | ERNAKULAM | KERALA | 682307 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical OFFICE NO 507 ELLORA FIESTA PLOT NO 08 SANPADA SECTOR 11 NAVI MUMBAI MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | - | Rejected-Technical stamp paper not submitted |
Tender Value
₹1.3 L
EMD Value
₹32,600
Closing Date
20 Aug 2022, 11:00 amClosed
REGISTRAR
KFRI PEECHI
Supply, Installation, Testing and Commissioning of 125 KVA Diesel Generator on buy back scheme at KFRI,Sub centre, Nilambur
2022_KCSTE_502289_1
KFRI/95/2021/TOelectrical
Open Tender
Electrical Works
Item Rate
60 days
KFRI SUB CENTER NILAMBUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
₹32,600
15 Nov 2022
5 Aug 2022
22 Aug 2022
5 Aug 2022
20 Aug 2022
5 Aug 2022
Amount
Supply, Installation, Testing and Commissioning of 125 KVA, silent type, water cooled, radiator type, four stroke, electric start D.G Set with acoustic enclosure and standard control panel with 200A, 4P MCCB with stand by low earth fault relay using Neutral CT, additional battery charger,Meter for Reading amps, Voltage etc... indication lamp etc. The engine shall be capable of taking 10% overload for one hour after 12 hours of continuous operation. The alternator shall be brushless, self excited, self regulated, SPDP enclosure, class F/H insulation, suitable for continuous operation at 1500 rpm, generating 415 V +/- 5% at 0.8 p.f, 50Hz, 0.80 load factor, 3 phase, 4 wire system generally conforming to BS: 2613 & IS: 4722. The neutral of the DG set shall be provided with low set earth fault relay using adequate Nutral CT in the neutral earthing conductor . Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as antiviberation pad, lead acid batteries (as specified by engine manufacturer) and engine driven battery charger along with leads, battery stand, fuel piping from fuel tank to Engine, electronic governor, Residential silencer, suitable size cable termination box etc as required. Rate shall be inclusive of all lift, lead charges. The work should be as per Electrical Inspectorate / Pollution control board norms,One year year manufacture warranty cumins,kirloskar or equvalent brand
Supply & installation of exhaust gas piping of suitable diameter for 125kVA DG set as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, wire mesh & aluminum cladding etc as required
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Supply and providing plate earthing as per IS 3043 with 600x600x3 mm copper earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Supplying and laying 25 mm X 5 mm copper stripat .5 meter below ground level as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.joining shall be done by overlapping and with 2 sets of brass nutbolt and spring washer spaced at 50 mm
Providing and fixing 4.00 mm dia copper wire on surface or inrecess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Supply, of one number PVC insulated and PVC sheathed, XLPE power cable of 1.1KV grade as required. 120sq mm 4 core
Supply, of one number PVC insulated and PVC sheathed, XLPE power cable of 1.1KV grade as required. 25 sq mm 4 core
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.120 sq mm 4 core
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 120 sq mm 4 core
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 25 sq mm 4 core
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supply and providing 6 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969
Supply and providing CO2 type 4.5Kg fire extinguisher or equivalent.
Supply and fixing 9 litre capacity GI fire bucket painted in post office red with primer coat of red oxide
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders inexisting cubicle panel board including drilling holes in cubicl panel, making connection etc as required.250A FPMCCB
100A FPMCCB
Supply and fixing 100A change overswitch box
Supply and fixing 63A change overswitch box
Preparation of schematic drawing and getting approval from Kerala State Electrical inspectorate, including liaison works etc complete as required but excluding statutory charges.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size)
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Steel work in built up tubular ( square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Providing and fixing 25 mm square weld mesh of 10gauge welded with 30mm GI square pipe frame including all materials, welding charges, fixing charges, and painting with Epoxy primer coat etc. completeas per the instructions of Engineer Incharge
Painting two coat with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Roofing with Galvanized iron color coated trafford sheets 0.50mm (including colour coated G.I ridge, hip and valley sheets, j-bolts, washers etc) on a frame work of M.S. rectangular pipes (B-class) m.s rods, iron plates, etc. ( already done and paid seperately) with over laps of 150mm at the ends all cost of materials conveyance and labour charges etc complete all levels as per direction of engineer in charge.
Buy back cost of old 50 KVA Diesel generator set with panel including 18% GST
VIRTUS TECHNO
BPE BHARATH POWER ENGINEERS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .