Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L1 | Accepted-AOC Being lowest bid | |
| 2 | L2₹8.9 L+₹1.3 L (17.4%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L2 | Rejected-Finance Being Higher Bid | |
| 3 | L3₹12.2 L+₹4.7 L (61.5%)Rejected-Finance | L3 | Rejected-Finance Being Higher Bid |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REPAIR / REPLACEMENT OF EXTERNAL LT ELECTRIFICATION AND CONNECTED WORKS AT MIL STN DHARCULA
2021_MES_441132_2
8377/DHR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Dharchula
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Pithoragarh
₹17,000
Yes
16 Aug 2021
11 Jun 2021
5 Jul 2021
11 Jun 2021
3 Jul 2021
14 Jun 2021
11 Jun 2021 - 14 Jun 2021
75 days
Amount
DESCRIPTION OF ITEMS
M & L for stay assembly complete with stay rod 20mm dia including stay wire 7/3.15 mm fixed to stay of poles including necessary stay clamp of flat iron, nuts and bolts, and including dismantling of old stay assembly etc complete all as specified and shown in electrical plate of SSR part-1 2009. Note:- Excavation and concrete shall be measured & paid separately under relavant items.
S & F in replacement ACSR conductor of any type and size stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between spans etc complete all as directed by Engr-in-charge.
Supply and fix in replacement cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5/ 4 core XLPE, armoured, Al conductor cable Outdoor type and taking down of old one for following size of cables:
(a) cable size 4 core 10-16 sqmm
(b) cable size 3.5 core 25 - 50 sqmm
Supply and laying or fixing or passing through pipe in replacement, 1100 Volts grade heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and over all PVC sheathed stranded conductor complete all as specified and directed for following sizes nominal cross section including taking down/ removing the unserviceable cable the following sizes: (Note: - Excavation & earth work, sand cushioning bricks protection & GI pipe where reqd. shall be measured & paid separately).
cable size of cross sectional area 10 sqmm of 2 core
cable size of cross sectional area 16 sqmm of 2 core
cable size of cross sectional area 35 sqmm of 3.5 core
cable size of cross sectional area 50 sqmm of 3.5 core
S & F in replacement pin type procelain white / brown / green / insulator(inplace of defective one) including galvanised mild steel spindle, two galvanised iron Washers and one galvanised iron nut,100mm height 65mm dia for 1100 volts grade complete all as specified & directed.
S & F in replacement shackle type insulator(inplace of defective one) vitreous procelain white / brown / green with and including galvanised mild steel straps, washers, insulator, bolts and nuts, insulators of size 100mm height and 115mm max dia with working pressure 1100 volt and galvanised steel straps 31X 5 mm size and dia of bolts 14mm complete all as specified & directed.
S & F in replacement plastic moulded polly propeline phase separator for LT OH line for working pressure upto 415 Volts of appropriate length and 25mm width with fly nuts & clamps suitable for following bunch of conductors.
Suitable for 4 wires
Suitable for 5 wires
Labour only for tightening of LT stay assembly incl replacement of stay clamp where as required complete all as spfd & directed by Engr-in-Charge.
M & L for tightening, stringing of ACSR conductor of any size for LT over head lines on poles including binding & testing complete all as specified and directed
M & L for GI pipe in replacement, light grade 40 mm for cable protection etc all as specified and directed
M & L for cutting of road / PCC hardstanding to a size of 300mm in width and n. exc. 60cm in depth for laying of protection pipe for cable including returing filling spreading leveling watering and well ramming in layers and providing 100 mm thick PCC 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
M & L for MCCB of capacity 125 Amp 3 pole , 415 V, 50 Hz 36 KA with adjustable thermal and adjustable magnetic protection release to existing LT panel board, making all connectionsluding suitable lugs, testing commissioning including taking out unsv MCCBs by disconnecting all electrical connection on existing position from LT Panel board and complete all as specified and directed.
All as per item No 12 above as but MCCB 200 Amp 4 pole , 415 V, 50 Hz 25 KA
Cutting /Trimming the tree branches of any size touching /embaracing the OH line of LT up to 1.5 Mtr on both side of the OH line & upto 3 RM above the over head line incl removing the same from site to a distance not less than 250 Mtr away complete all as specified & directed incl providing T&P as and where required. Note : Approx distance of each span is 10 Mtr.
Excavation in trenches in hard/dense soil n exc 1.5m wide and exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for layingpipe/ cable complete all as specified and as directed by Enge-in-charge befor returing filling the earth.
Returning filling in excavated soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as specified and as directed.
Removal of surplus excavated soil to a distance exc50 m but not exc in 100 m and deposited wher directedat a leveln exc 50 m above the starting point complete all as specified and as directed.
M & L for Sand cushioningng (dry sand) to under ground cable for cable protection provided with layers 8cm thick before laying and 15cm thick after laying the cable and punned down to 23 cm thickness complete all as specified and directed. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 18cm as mentioned in para19.75 of SSR Part-I
Supply and laying sub class B bricks old size for protection of cables laid lengthwise perpendicular to the axis of cable, adjecent to each other complete all as specified and directed.
M&L for repair to GOD & DO, changing of male & female contacts, knife, greasing, damaged insulators, nut bolts etc complete all as specified and directed.
M & L for replacing continuous earth GI wire of size not less than 8 SWG/4mm dia by making all the connectins and fittings good and properly connected with the existing earthing complete testing including dismantling of old/unsv continuous earth wire as required at site complete as specified and directed.
Zero cutting of bushes/grass, unwanted veg growth in and around the electrical installations, transformers,panel boards,HT/LT 4 pole / 2 pole structures, HT/LT electric poles,etc in complete station and disposed offf to the location not less than 50Mtr all as reqd at site/directed.
M & L for maintenance, servicing of diesel engine generating set 20 KVA/125KVA, 2 cylinder, air cooled 4 stroke 1500RPM, including valve seal cutting, valve grinding, head facing, servicing of dynamo, alternator, water pump, cleaning of exhaust manifold, radiator & fuel tank, etc and repairs of worn out parts and fixing/replacement of spares parts, nuts, bolts, washers, engine oil and complete service of rectifier for right flow of alternate current complete all as required at site to entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note:- Spare parts shall be measured and paid separately under respective items.
Supply only following spare parts suitable for air cooled diesel engine generating set Kirloskar
Air/oil/fuel/ and by pass filter
Fan/Alternator/water pump belts
Hose pipe suitable size
Oil seal set
Washer set
Battery leads copper cable of suitable size with brass connectors / terminals, nuts & bolts in red colour-03mtr & black colour -02mtr all as directed of length
Engine oil best grade 10W30/20W40
Disconecting and taking down self starter assembly of 20 KVA DG set from the existing position, opening and servicing by rectiffying defect / faults and repair replacement of internal parts like coils, corbon bushes, crcuits etc with ew ISI marked oarts, assembling and fixing with DG set inlcuding testing and commissioning complete all as specified and directed.
M & L for repair to LED street light of any make and any type, up to 45watt capacity fixed in poles or kept in store including repair / replacement of spares like driver / circuit board, unserviceable LED, toughned glass, cable connector, necessary cable to connect in site etc complete complete all as specified and directed.
Supply and fixing and testing complete as existing poles/walls aesthetically Designed SMD LED Street light luminaires of 45 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as > 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD <10% , P.F >.95 .The fitting should have in built surge protector of 5 KV, complete all as specified.
Supply & Fixing in replacement of old bracket made out of 40 mm bore light grade GI pipe bent to shape fixed as bracket suitable for street light fittings not less than 1.2 m long bent/welded to shape including necessary nut, bolt and clamp-02 No made of MS flat 40x5mm as reuired duly painted by unscrewing nut and bolts complete all as specified and directed.
M & L service connection 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with overall PVC sheathed 2.5 sqmm nominal cross sectional area complete all as specified and directed.
Supply and erection, in truly vertical position in replacement, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles, complete all as specified and directed. (Note : PCC, Earth work and MS work as cross arms clamps etc shall be measured and paid separately)
M & L for painting to steel tubler poles 9 m long including cross arms, street light brackets, earth pipe, clamps with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands /straps 25 Cm wide with paint red signal post office colour and 2 band 25 cm wide with white synthetic enamell paint 300 mm apart from plinth block and numbering of poles 100 mm height with white paint in black box of size 125x125mm , complete all as specified and directed.
Shifting of LT poles 9 mtr height after breaking PCC, taking out from trench, closing the trench with refilling and shifting refixing at the location complete all as specified and directed. Note: Cost of earh work, pcc work and demolation of pcc shall be deemed to inclusive in quoted unit rate.
M & L for PCC 1:3.:6 type C-2 using 40mm graded aggregate as in foundation/ for stay assembly etc. all as specified and directed
M & L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation/ for pole etc. all as specified and directed.
M & L cement concret type B2, 1:2:4 using 20mm graded aggregate for coping etc complete all as specified and directed
M & L for Earthing in replacment for sub station eqpt complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel earth plate surrounded by alternative quantity of charcoal dust & salt to a packed thickness of 15 cm on all side upto 15 cm above & below the plate, excavation earth work, returning, filling in removal of surplus soil upto 50 mtr on side,as shown in electrical plate No. 5 connected to earthing test point incl PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone agg pit cover in RCC 1:2:4 type B-0 using 12.5 mm graded stone agg with 6 mm dia mild steel round bars @ 100 mm C /C with 12 mm dia lifting handle incl providing 40mm dia GI pipe medium grade for watering, funnel & wire mesh etc complte including testing on completion complete all as specified & directed.
Supply and filling in topping up with electrolite /tilled water for solar street light / DG set batterries as same as kept with AGE office as specified & directed.
Demolition of cement concrete (un-reinforced) any description and laid in any position complete all as specified and directed.
SHAHJEE FRIDGE SERVICE
kumaon and hills strument engnering services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .