Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 56 57 HADAPSAR INDUSTRIAL ESTATE HADAPSAR PUNE MAHARASHTRA 411013 | PUNE | PUNE | MAHARASHTRA | 411013 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹30.0 L
EMD Value
₹29,963
Closing Date
2 Nov 2021, 5:00 pmClosed
District Police Chief, Palakkad
District Police Office, Near Yakkara Road,Palakkad,
Supply and installation of video walls and logistics for the emergency response support system facility of existing district control room.
2021_KP_445492_1
G1(b)/46690/2021P
Open Tender
Equipments
Supply and Service
60 days
District Police Office
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,600
Yes
₹29,963
Yes
24 Nov 2021
13 Oct 2021
3 Nov 2021
13 Oct 2021
2 Nov 2021
13 Oct 2021
13 Oct 2021 - 1 Nov 2021
Supply and installation of video walls and logistics
Supply, Installation, testing and Commissioning of 43inch 3840 X 2160 (UHD) monitors with one set of 3x3 and 2x2 splitters with looping for video wall display in 3x3 and 2x2 format with all the necessary accessories to complete the work as per specification
Supply and installation of 5/10/20 Mtr HDME cables from monior wall to control desk in cavity floor including 500MMx25X 2 MM concealed raceway arrangemnts in cavity floor with all the other necessary accessories to complete the works
Supply and fixing of Monitor Wall (6X3 Matrix) (H x W x D = 850/2600mm X 5822mm X 600mm) - as per design enclosed offering Monitor Wall with provision of placing 18 Nos. of 43"monitor on Functional Rail Mounts.xtruded Aluminum Profile structure (Powder Coated MS based Top/Bottom Frame and Foot. Laminated 17/18mm (±1mm) MDF Board Side Panels (Fixed side panels), Laminated 17/18mm (±1mm) MDF Board Front & Back Modesty (Removable Front & Back Modesty through lock with Knob). Table Top in 17/18mm Wire Managers - For routing LAN & Power Cables within the Wall. Power Distribution Sockets - within the wall for Powering of Active Devices (±1mm) Laminated Board as per specification
Supply and fixing of 4 USERS CURVE CONTROL DESK WITH EQUIPMENT RACKS User Control Desk (H x W x D = 750mm X 3800mm X 1030mm) - as per design enclosed offering Console desk with provision of placing 4 Nos. of monitor on monitor mounts, 4 Nos. of keyboard/Mouse on Sliding Tray.Extruded Aluminum Profile structure (Powder Coated) with MS (2mm) Top & Bottom Frame. Laminated 25mm (±2mm) MDF Board Side Panels (Fixed side panels), Laminated 17/18mm (±1mm) MDF Board Front & Back Modesty (Openable Front & Back Modesty through Lock with Knob). Table Top in Laminated 25mm (±2mm) MDF Board with Nosing, Monitor Base in Laminated 17/18mm (±1mm) MDF Board.Wire Managers - For routing LAN & Power Cables within the Desk. Power Distribution Sockets - within the Desk for Powering of Active Devices. Adequate Heat management provision for Exhaust of heat from within the Desk Assembly. Adequate space for CPUs & Other equipment's placed with in the Desk
Supply of all the materials required for maintenance free Earthing system including 3 mtrs length,20mm dia 250 microns molecularly copper bonded steel rod with stainless steel connectors and fasteners forconnecting 6AWG copper wire, earth enhancing compound (12.5 kg Nos mineral compound/ 22.6 kg low resistivity graphite compound),FRP (UFEFRP) earth electrode inspection chamber of size 200mmx 200mm dimension and flush with the surrounding with heavy duty cover having bearing capacity of 15KN etc as required.
Supply , installation, testing and commissioning ofof 24 port Fiber LIU patch panel and CAT-3 Patch panel 24 Ports , SCSC/SCSM pigtails with splicing and Duplex Fiber optic patch cords Single mode (LC to LC) 1M and all other items required to complete the work, patch cords and all other items required to complete the work
LAN networking and UPS power distribution of 18 nos monitors and control desk power and network provision in control room with required supply and Laying of CAT-6 Lan cable, finer cable connectvity and LCB/MCB , elecrical wires as per load calcutions etc.. with all other necessary accessories to complete the work
Shifting of existing ANPR control room equipments with all Central Monitoring server and storage , Client machines ,desktop monitors etc..for ANPR as per specification and all other necessary accessories to complete the work
Supply and Installation of 22U Floor mount indoor Rack with Lock/6x6ams 3pin plug 1MCB power distribution unit and cable Manager(1nos), cooling Fan,adjustable shelf(2nos), proper earthing and all other necessary accessories to complete the work
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .