| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC BEING LOWEST TENDER |
| 2 | L2₹1.9 Cr+₹23.0 L (14.0%)Rejected-Finance 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | ₹1.9 Cr+₹23.0 L (14.0%) | L2 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 3 | L3₹1.9 Cr+₹23.1 L (14.1%)Rejected-Finance | ₹1.9 Cr+₹23.1 L (14.1%) | L3 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 4 | L4₹1.9 Cr+₹26.6 L (16.2%)Rejected-Finance | ₹1.9 Cr+₹26.6 L (16.2%) | L4 | Rejected-Finance HIGHER THAN LOWEST TENDER |
| 5 | L5₹1.9 Cr+₹28.7 L (17.5%)Rejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹1.9 Cr+₹28.7 L (17.5%) | L5 | Rejected-Finance HIGHER THAN LOWEST TENDER |
Tender Value
₹1.9 Cr
EMD Value
₹2.4 L
Closing Date
15 Aug 2022, 6:00 pmClosed
BRIG AJAI SINGH CHONKER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
ADDN ALTN AND SPL REPAIRS TO HANGER 1S LOC AT ENGR REGT AT KANCHRAPARA MIL STN UNDER GE BARRACKPORE
2022_MES_535812_1
89057/E8
Open Tender
Civil Works
Item Rate
360 days
GARRISON ENGINEER BARRACKPORE
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GARRISON ENGINEER BARRACKPORE
₹2.4 L
Yes
10 Sept 2022
5 Jul 2022
17 Aug 2022
5 Jul 2022
15 Aug 2022
1 Aug 2022
Amount
Dismantling Plain or corrugated steel sheeting any guage, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
S&F for prepainted galvatume aluminium zinc coating GI based corrugated/semi-corrugated steel 0.50 mm thk of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw as in roof complete all as specified and directed
M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws complete all as specified and directed
Dismantling structural steel work in tubular purlins including doors, gates but excluding framed trusses etc complete all as specified and directed
S&F in repairs for Rolled section as in main & cross beams, hip & jack rafters; purlins where connecting to common rafters & running rails & guides for sliding doors; fixed with angles cleats o other connecting plates conforming to Fe 290 (Gde-E-165) complete all as specified and directed
Erection and fixing only Rolled section as in main & cross beams, hip & jack rafters; purlins where connecting to common rafters & running rails & guides for sliding doors; fixed with angles cleats o other connecting plates .
Demolitin of brickwork built in cement mortar including all quions ,arches,pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles
M&L for Brick work with sub class'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM (1:6) complete all as specified and directed
All as per description of item 08 above but except bricks complete all as specified and directed
M&L Brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed
All as per description of item 10 above but except bricks complete all as specified and directed
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed
M&L Rendering 15 mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 20mm thick cement plaster (in two layers) on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement top layer 5mm thick with WPC @ 3% by weight of cement complete all as specified and directed Note:- WPC will be paid separetes item
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided complete all as specified and directed
M&L Reinforcement cement concrete type M-25 (Design Mix) as in beams, cantilever, bressummeres lintels over 1.50m spam complete all as specified and directed.
M&L Reinforcement cement concrete type M-25 (Design Mix) as in foundations including rafts, footings, foundations beams, plinth beams, bases for columns and basement slabs etc complete all as specified and directed.
M&L Reinforcement cement concrete type M-25 (Design Mix) as in columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L Reinforcement cement concrete type M-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar works, flat rough finished surafaces of concrete; not exceeding 200mm thick (horizontal or sloping)
Form work to sides and soffits of floor and roof beams, beams haunching, girders, bressummers, lintels and cantilever, shelves including supports over hangs etc rough finished surfaces of concrete ( flat ) complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including flat rough finished surafaces of concrete complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions, square, rectangular or polygonal in shape, including flat rough finished surafaces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed
M&L for Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed
M&L for Mild steel TMT bars 6 to 10mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, as in stirrups/ spacer hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to Fe-310-O or Fe-410-O complete all as specified and directed
S&F for Framed work such as grills, Gate, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; hang as gate incl pintel hinges. Stops, hand made sliding bolt conforming to Fe 290 GDE -E-165 complete all as specified and directed
M&L Preparation of new steel sufaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfaces complete all as specified and directed
M&L One coats of synthetic enamel paint on old steel surfaces of any description, n.exc 10 Cms in width or girth, including preparation of surfaces, complete all as specified and directed.
Preparation of new plastered surface of external wall and chajjas and making the surface smooth with sand paper and priming the surface with alkali resistance primer paint for external surface, over primed surface applying two coat of cement base paint incl curing complete all as specified and directed
M&L three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and directed
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and directed
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed
S&F 4 mm thick Fibre cement Standard ceiling board of Everest or equivalent make with false ceiling (oceanic) with powder coated exposed G.I grid suspension system (E- Grid T 2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span withhanger spacing of 1200 long cross Tee 1200/600 mm long and wall Angle . The wall Angle shall be fixed on pvc Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c . The main Runners to be placed @1200 mm c/c . The Cross Tee 1200mm will be inserted in the pre cut slots of Main Runner at a Regular interval of 600 mm to form a modular grid of 1200mm x600 mm . Additional cross Tee 's of 600 mm shall be placed perpendicular to the cross Tee 1200 mm long to finally from a grid of 600 mm x 600 mm. Grid ofr module of size 600 mmx600mm shall be supported by 6 mm dia G.I. wire from purlins / soffits. 6 mm thick High pressure steam cured Non Asbestos Fibre cement standard ceiling Board ( Density > 1200 kg/ cum ) of size 595mm x 595 mm , conforming IS 14862 & Type B category III of ISO 8336 , tested as per AS 1530 part - 3 & B. S - 476 part 4,5,6,7&8, should be placed in Grid module to form (Make:- GI grid- Jindal or armstrong and Ceiling board- Everest) complete all as specified and directed
S&F for Steel windows with side hung shutters including Box type hinges with steel handles, & steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
S&F for steel ventilators with top hung shutters incl. hinges, steel peg stay complete all as specified and directed
S&f for 4mm thick Figured glass, pin head type and glazing with oil putty in squares/rectangular n exc 0.5 sq. m in each pane complete all as specified and directed
S&F pressed steel frame made out of MS sheet 1.25mm thick of size 105x60 mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-0 (12.50 mm graded aggregate) back of chowkhats and incl two coats of synthentic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed
S&F for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkats all as specified and directed
M & L preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
S&F for 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane all as specified and directed.
S&F 250 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed
S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed complete all as specified and directed
S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified.
Roughenig surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as directed.
M&L for 50 mm thick (avg thickness) plain cement concrete type C-2, 1:3:6 ( using 40mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed
M&L for 40 mm thick plain cement concrete type B-0, 1:2:4 ( using 12.5 mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed.
M&L for 15mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) as per manufactures instruction complete all as specified and directed.
Supply only Metallic floor hardener ( at the rate of 7 kg per sqm ) complete all as specified and directed. Make : Floor Metalic hardner : M/s Sika India Pvt Ltd, M/s Maruti Bitumen Pvt Ltd, M/s Hindustan Chemicals Ltd (Floor toppings / Hardening), M/s Thermax Ltd or equivalent as per approved by GE
S&F for vitreous china squatting pan of 'orissa' pattern long pan size 580 mm x 440mm white front or back inlet and including provision of PCC or lime concrete bedding and 32 mm dia flush pipe etc and removal of debris complete all as specified.
S&F vitreous china wash down water closet pan (pedestal pattern)(EWC) white including plastic water closet seat cover closed pattern with flat bottom, and cover and mild steel chromium plated hinging device etc complete complete all as specified and directed
S&F for 10 litres capacity PVC valve less syphonic action type, flushing cistern, low level with inlet ball valve and bracket etc, complete all as specified and directed including taking out old one complete all as specified and directed.
S&F for PVC connection 450mm long suitable for 15mm nominal bore complete with brass nuts all as specified.
S&F 110 mm dia PVC (SWR) pipes single socketed ,in any length with rubber ring joints , laid in trenches or in floor compleate all as specified and directed.
S&F 110 mm dia PVC (SWR) pipes single socketed ,in any length with rubber ring joints ,fixed to walls etc compleate all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius with access doors complete all as specified and directed
S&F for 110 mm dia PVC cowls complete all as specified and directed.
M&L for Cast iron floor trap 100 dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed
M&L Coloured Glazed ceramic tiles in vertical surface 450mm x300mm x 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
Material & Labour Non Skid ceramic colour tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for 15mm thick screed bed in cement mortar (1:4) for laying floor/roof finishes etc complete all as specified and directed
M&L for rendering 10mm thick on brick or concrete surfaces in cement mortar (1:3) as in screed bed for laying wall finishes complete all as specified and directed
Supply and fix for factory made PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
Supply and fix for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and as directed.
S&F 75 mm size stainless steel butt hinges medium weight cold rolled complete all as specified and directed
M&L for 100 mm size aluminium anodised cast type handles complete all as specified and directed
S&F of 100mm long aluminium anodised,barrel tower bolt of extruded section complete all as specified and directed
Supply and fix for Vitreous China wash hand basins white colour and flat back of size 550 mm x 400 mm excluding taps , waste chain and porcelain stopper but including brackets complete all as specified and directed
Supply and fix for 15 mm bore pillar taps cast copper alloy, with capstan heads, chromium plated, fancy type complete all as directed by Engr in Charge.
Supply and fix for vitreous china urinal flat back, Half stall type with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2,securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixed in repairs, complete all as specified and directed.
S&F 15mm bore dia bib taps cast copper alloy chromium plated, fancy type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and as directed.
Supply and fix stop valve/ angular stop cock fancy type, cast copper, chromium plated, screed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed 15m bore pipe complete all as specified and directed
S&F 15 mm bore GI pipe tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
S&F 20 mm bore GI pipe tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
S&F for 1000 Ltr capacity rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed tap) twisted and fixed in position all as specified in SSR Part-I
S&F for ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, screwed for iron pipe of 20 mm bore ( min weight 210 gms), complete all as specified and directed.
Cutting chases, pinning in making good to facings brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings steps cills chases for concealed water tubing, exc 10 cm but not exc 20 cm girth complete all as specified and directed
M&L for PCC type D-2 (1:4:8 ) using 40 mm graded stone aggregate for Foundation and Mass Concrete Compleate all as directed.
Excavating in trenches, n.exc 1.5m wide & n.exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. nexc10 sq m on plan & n exc 1.5 m in depth & getting out in soft/loose soil, complete all as specified and directed.
Returning filling in including spreading, levelling,watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding and depositing where directed at a level not exceeding 1.5m above the starting point and disposal complete all as specified and directed
M&L for 40mm thick Damp proof course, in cement concrete 1:2:4 type-B-0, to horizontal or vertical surfaces, including necessary formwork complete all as specified and directed
M&L for Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. M complete all as specified and directed
S&F for Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members (not exc 4kg per sqm)(size- 25mm x 75mm) complete all as specified and directed
Supply only Liquid water proofing compound complete all as directed
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30cm in depth, 1.5m depth width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lead upto 1.5m as directed by Engr-in-Charge.
All as per item No 1.87 as above but not exceeding 1.5m depth.
M&L Brick work with sub class 'B' bricks straight or curved on plan n exc 6 mtr mean radius built in CM (1:4) complete all as specified and directed
M&L Brickwork with subclass ‘B’ bricks in one and half brick thick honey comb walling, built in CM (1:4) complete all as specified and directed
M&L Rendering 15 mm thick cement plaster on fair faces of brick work in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed
M&L for Loose filling with Broken bricks aggregate of guage 40 to 80mm in soakage pits, soakage wells complete all as specified and directed
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L for Reinforcement cement concrete type B1 1:2:4 ( 20 mm graded aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses and the like complete all as specified and directed
M&L Hardcore of guage exc63mm,Broken Bricks deposited, spread & leveled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, fair finished surfaces complete all as specified and directed
M&L cement concrete type B1 1:2:4 (20 mm graded aggregate) as in benching and copings of drain/man hole including necessary moulds and form work complete all as specified and directed
M&L for salt glazed stoneware drain pipe 100 mm internal dia grade 'A' laid in trenches and jointed and tested complete all as specified .
M&L for PCC type C2 1:3:6 (40 mm graded aggregate) for concrete bed to drain pipes for 100 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
S&F for 100 mm bore cast iron soil waste and vent pipes (sand cast) in any length with or without ears, with cement joints, fixed to walls complete ISI Marked complete all as specified and directed
S&F salt glazed stone ware gully traps of size 150 x150 mm square or round moulded type 'P' complete all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed
M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth complete all as specified and directed.
M&L for Providing, cement concrete, type B-0 (1:2:4) (using 12.50 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed
M&L Rendering 10 mm thick cement plaster on fair faces of brick work in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed
M&L for sub-main wiring with two single core 6 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including 25 mm dia non-metallic PVC conduit fixed in RCC wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC.
M & L for point wiring complete with FRLSH PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though complete concealed wiringn including non metallic medium grade rigid PVC conduit accessories, ISI marked, 19/20 mm dia including all accessories on the surface of walls/floors/ceilings and making good the disturbed surface, with and including sunken type pressed steel/welded MS terminal box 1.2 mm thick bakelite laminated sheet top cover 3 mm thick and 1.5 Sq mm copper earth continuity wire connected to earth dolly complete for the following complete all as specified and as directed by EIC.
(a) One light point controlled by one switch.
(b) One ceiling fan/exhaust fan controlled by one switch.
(c) One 3 pin socket outlet 5 Amps on the same board.
(d) one 3 pin socket out let 5 Amps on the independent board.
All as per Item No. 2 above but 2.5 Sq mm multi stranded copper conductor with 2.5 Sq mm copper earth continuity wire connected to earth duly complete for one 15A Socket on Independent board all as specified and as directed by EIC.
S & F angle lamp holder, PVC Polycab type with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix LED bulb 12 watts suitable for batten holder bipin type complete all as specified and directed
Supply and fixing surface & wall mounted LED batten 4 feet with 1x20 Watt indoor decorative luminaries with and including electronic driver and 1x20 watt LED Lamp, pre-wired including necessary electric connection with copper flexible PVC cable of 0.50 Sq mm 3 core not more than 1 mtr in length from ceiling rose/connector to light fitting,conforming to the following specifications: - (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2400 Lm, voltage range- 140 to 270 Volts, continious operation of 2 hours at 320 Volts.(ii) Housing: - Aluminium Extruded body. (iii) IP rating: - Minimum IP 20. (iv) Front cover: - Acrylic/polycarbonate cover (v) Mounting: - Suitable for wall/ ceiling mounting. (vi) Finish: - Smooth finish. (vii) Lamp: - High bright LED. (viii) System Efficacy of Luminaries (lm/Watt): - Not less than 120 Lm/watt. (ix) Colour temperature: - Not less than 5700 degree K. (x) Colour rendering index (CRI): - Not less than 80. (xi) Life: - Not less than 25000 hrs of operation. (xii) Optics: - Designed for optimum light distribution. (xiii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz. (xiv) Surge protection: - Inbuilt surge protection minimum 2.5 KV. (xv) Heat sink: - As per OEM's design complete all as specified and directed. Note:- Bidder has to compulsorily submit the LM-79 and LM-80 and NABL accredited lab test report conforming to technical specifications and consolidated lab report for the offered LED has to be struct structured in the same sequence.
S & F 200 Watt High power LED flood light (on Long span steel fabricated hanger having dimensions 150Mx54Mx15M, LxWxH) made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. Systerm efficacy > 110LPW. Option for 3000K and dincluding 10 KV SPD complete with all connected accessores for fixing on channels with suitable size of clamps, nut bolts, washers all as specified and as directed by EIC. Note - Quoted rate deemed to be included for testingn and commissioning of flood light at a height of 12-15 meter from the ground level and provision of T&P for fixing the light fitting is also included in unit rate offered by the Contractor.
S & F Socket outlet, flush type 2 in 1, 3 pin, 5 amps, 240 volts all as specified and as directed by EIC.
S & F switch piano flush button single pole one way 5 amp 240 volts, all as specified and as directed.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amps, flush type, 240 volts all as specified and as directed by EIC.
S & F switch piano flush button single pole one way 15 amp 240 volts, all as specified and as directed.
M & L for ceiling rose, surface bakelite, 65 x 50 mm, three terminals all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed.
S & F sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 4 way with 200 amps rated busbar, 240 volts, as per IS-8623 all as specified and as directed.
S & F vertical load line in sheet metal enclosures MCCB TPN DB's with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgooinh , IP-43 , TPN4 way with 200 amps rated busbar, 440 volts, as per IS-8623 all as specified and as directed. Note- MCCB 3 pole 63 amps as main incomer will be measured and paid separately
S & F single pole and neutral enclouser with two pin and earth plug and socket complete with one single pole MCB complete suitable for 240 volts, single phase supply and 20 amps rating all as specified and directed.
S & F MCCB 63 Amps, 3 pole, 16 KA , fixed type complete all as specified and directed by EIC.
S & F MCB SPN 40 Amps, 240 volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
S & F MCB SP, 6 to 32 Amps, 240 volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs all as specified and as directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel pipe electrode, 600mm x 600mm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below nominal ground level) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to galvanised earthing lead of 4 mm dia of iron or steel wire all as shown in electrical plate No. 5 all as specified and as directed. Note :- the cost of excavation and earth work PCC pit and CI cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing all as specified and as directed by EIC.
M&L for sub-main wiring on Parabolic Steel Hangers angle iron structure with two single core 2.5 sq mm FRLSH PVC insulated unsheathed stranded copper conductor cable drawn through including providing MS flat clamp for fixing the PVC conduit including 20 mm dia non-metallic PVC conduit heavy grade fixed in wall/MS angle iron at a height not more than 10 meter from ground level including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete, all as specified and as directed by EIC. Note - Sub main wiring includes two run of 2.5 Sqmm and one run of 2.5 Sqmm as earth wire with making arrangement of fixing of 20 mm conduit on iron angles of a Parabolic Hanger having maximum height not more than 15 mtr from ground level and rates quoted is deemed to be included in unit rate by the Contractor.
Material and labour for XLPE insulated,LT armoured electric cable with aluminium standed conductor 1100 volts grade,cross-sectional area 35 sqmm ,4 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc and testing complete all as specified and directed.
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
M & L for 50mm bore GI pipe (Light grade) laid under road or fixed with pole/wall of culvert as in protection of UG cable incl necessary MS clamp and complete all as specified and directed.
Boaring holes horizontally under Road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 100 mm dia for passing of UG cable all as specified and as directed.(GI Pipe laid shall be measured seperately) complete all as specified and directed
M & L Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed
M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
M & L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4MM galvanised iron strip complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and includingGI Strip of size 32x6mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (GI strip upto 7.5m including testing consider in this item).
Supply and fixing CRCA kiosks box 2 mm thick suitable for Earthing test point having size 250x250x150 mm complete including making fixing arrangement with brick/stone/RCC wall with flat iron clamp all as specified and directed by Engr-in-charge. make- Sintex/Star electric Eng Co./Universal switch gear control/CPRI approved
M & L for GI tubing medium grade 25 mm bore laid under trenches, with wall incl all fittings complete all as specified and directed
M & L for GI tubing medium grade 20 mm bore laid under trenches, with wall incl all fittings complete all as specified and directed
M & L for gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 25 mm bore complete all as specified and directed
M & L for gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 20 mm bore complete all as specified and directed
M & L for cuting existing GI tubings for alterations or additions for 40mm or 50mm dia complete all as specified and directed
Construction of valve pit chamber with brick masonary with sub class 'B' bricks (one brick thick) in cement mortar (1:6) and necessary PCC (75mm thick) type D2 (1:4:8) as in foundation and 15mm thick plastering on brick work in cement mortar (1:4) including necessary earthwork etc work having internal dimension 120cm x 120cm x 90cm and providing of 3mm thick MS sheet cover duly hinged on 40mm x 40mm x 6mm angle iron frame and embedded on top of chamber by minimum 4 Nos MS hold fast. Necessary locking arrangement shall be provided to the sheet cover for safety. The steel surfaces shall be painted with two coats black bituminous paint over a coat of anti corrosive red oxide primer complete after demolition of old valve pit chamber all as specified and directed.
ROY CONSTRUCTION
M/S KANCHAN KANTI BAKSI
BUSINESS SYNDICATE
NARSINGH DEVELOPERS LLP
USHA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .