Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC being L1 bidder | |
| 2 | L2₹25.0 L+₹3.1 L (14.1%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L2 | Rejected-Finance being not L1 bidder | |
| 3 | L3₹26.7 L+₹4.8 L (21.9%)Rejected-Finance MIG 330 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L3 | Rejected-Finance being not L1 bidder | |
| 4 | L4₹27.3 L+₹5.4 L (24.5%)Rejected-Finance D NO 9 2 1 1 VUDA QUATERS PITHAPURAM COLONY VISAKHAPATNAM PIN 530 003 | VISAKHAPATANAM | ANDHRA PRADESH | 530003 | L4 | Rejected-Finance being not L1 bidder | |
| 5 | L5₹28.2 L+₹6.3 L (28.7%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance being not L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Jun 2023, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF UG CABLE DG SET, STREET LIGHTS, GARDEN LIGHTS, HIGH MAST LIGHTS, PACKAGE AC PLANT, UPS AND OTHER MISC WORKS AT INS CIRCARS, NOI, HQ ENC AND OTHER ALLIED AREAS UNDER GE (UTILITY-I) VISAKHAPATNAM
2023_MES_596592_1
8547/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
AS per NIT
5 documents required · 5 mandatory
₹500
Garrison Engineer Utility-I
₹80,000
Yes
30 Jun 2023
18 May 2023
17 Jun 2023
18 May 2023
15 Jun 2023
2 Jun 2023
Amount
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cable, foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
Labour only for laying of bricks sub class 'B' (Old size) reused for cable protection cover , laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
S&F 40 mm bore galvanised steel tubing, medium grade with necessary fittings, laid under road crossing, for cable protection complete all as specified and directed. Make - Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete including demolition of old PCC complete all as specified and directed.
M&L cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in copings, benching and the like etc. including necessary formwork & demolition of old concrete complete all as specified and directed.
Taking down defective street light fitting of any make / type / capacity from top of pole / walls / high mast at a height not less than 7.0 m, at any location, for repair work and re-fixing the same after repair work including testing and commissioning complete all as specified and directed. Note:- (i) M&L for Items like ballast, lamp, ignitor, capacitors, electronic drivers, surge protection devices etc shall be measured and paid separately under relevant items. However rate quoted shall deemed to include cost of minor spares like nut bolts, circle clips, clamps etc (if reqd) (ii) Necessary T&P like ladders etc required to take the fitting down shall be arranged by the contractor.
S&F in repairs electronic driver of make as per existing, suitable for 120 to 250W street light / flood light / post top lantern complete all as specified and directed. Note:-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
All as per serial Item No. 12.00 above but suitable for 90 to 100 W
All as per serial Item No. 12.00 above but suitable for 70 to 80 W
S&F in repairs only surge protection device of capacity 10 KV & make as per existing, suitable for street light / flood light / post top lantern complete all as specified and directed. Note:-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
M&L for dismantling defective LED street light fitting of any make / type and of capacity 120 to 250 W, strip opening the LED panel complete including identifying defective LED diodes, supply and replacement of defective LED diodes, soldering, replacement of pitted control wiring from LED panel to driver etc, testing and commissioning complete all specified and directed by Engineer-in-Charge. Note :-The rate quoted is not inclusive of taking down & refixing of street light fittings and the same shall be measured and paid separately under relevant item.
All as per serial Item No. 16.00 above but LED street light fitting of capacity 90 to 100 W
All as per serial Item No. 16.00 above but LED street light fitting of capacity 60 to 80 W
S&F LED street light fitting of capacity 60 watt, IP-65 (minimum), integrated type with high efficiency electronic driver, SPD of capaciity 10 KV, pressure die cast aluminium housing with toughened glass cover, internally prewired and including electrically connecting & taking down complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj Note:- Supply of new GI Pipe bracket if required shall be measured and paid seperately under relevant item.
All as per serial Item No. 19.00 above but LED street light fitting of capacity 90 W
All as per serial Item No. 19.00 above but LED street light fitting of capacity 100 W
S&F LED flood light fitting of capacity 100 watt, IP-65 (minimum) with luminous efficacy 100 Lumen/watt (minimum), SPD of capaciity 10 KV, pressure die cast aluminium housing, toughened glass cover, internally prewired and including electrically connecting & taking down old unserviceable flood light fittings from any position at a height exceeding 7.5 m & taking down complete all as specified and as directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
All as per serial Item No. 22.00 above but LED flood light fitting of capacity 150 W
All as per serial Item No. 22.00 above but LED flood light fitting of capacity 200 W
All as per serial Item No. 22.00 above but LED flood light fitting of capacity 250 W
S&F 40 watt LED post top lantern with polycarbonate opal diffuser, pressure die cast aluminium housing, IP-65 (minimum), high efficient constant current electronic driver including electrically connecting and taking down complete all as specified and directed. Make :- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
S&F in repair 1 x 9 / 10 watt LED bollard light fitting, bamboo shape, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
S&F in repair 1 x 9 / 10 watt LED bollard light fitting, inverted conical shape, opal acrylic diffuser, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
S&F in repair 1 x 9 / 10 watt LED bollard light fitting, mushroom shape, IP-65, including hot dip galvanized pole, driver, all fixing arrangement etc. including electrically connecting complete all as specified and directed. Make:- Signify Innovations India Ltd (Formerly Phillips) / Havells / Crompton / Bajaj
S&F three phase, automatic street light control panel with and including astronommical timer switch for automatic switching on / off street light as per set time through programmable switch, 65A, TP power contactor, suitable capacity MCB / MCCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock including taking down complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd / Indo Asian
S&F MCCB 3 pole 200 Amps, thermal magnetic release adjustaple type, breaking capacity 25 KA, Ics = 100% Icu including necessary modification in the panel & taking down existing MCCB complete all as specified and directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand / Indo Asian (Optipower)
All as per Sl item No. 31.00 above but 63 to 100 Amps
Taking down existing loop in loop out junction box, disconnecting the cable connections and refixing the same loop in loop out junction box with new cable connections including providing new set of aluminium lugs / thimbles of size 10 to 35 sqmm (as reqd) for 3.5/4 core existing LT cabe of any type, necessary insulation with tape, clamps for fixing of cables, fittings and fixtures, nut bolts etc complete all as specified and directed.
Taking out existing XLPE Cable of any size in underground / alongwith pole or in any positon, removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed. Note:- Excavation and earthwork (if required) shall be measured and paid seperately.
Re-laying only old servicable (cable obtained from taking out old cable here-in-before after checking the fault) UG LT XLPE electric cable with alumimium conductor, 1100 volts grade of any size, laid in trenches / duct / on pole complete all as specified and directed.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 25 Sqmm x 4 Core, laid in trenches / duct / on pole complete all as specified and directed. Make :- Havells / KEI / Polycab / Gloster / Finolex
All as per Sl item No. 36.00 but cross sectional area 16 Sqmm x 4 Core
All as per Sl item No. 36.00 but cross sectional area 50 Sqmm x 3.5 Core
M&L for disconnecting electrical connection of defective / burnt out UG LT cable of any size 2 to 4 core from main switch / DB / Junction boxe / LT Panels, excavating, taking out the required length of existing cable from loop, cutting the defective portion of cable old termination at end, providing new aluminium thimbles / lugs of suitable size and reconnecting the same with existing location and refilling of cable trench with existing sand and bricks complete all as specified and as directed. Note :- (i) The rate quoted shall deemed to include cost of necessary earth work, matching the disturbed surfaces as per existing. (ii) Additional length of cable or joint required shall be measured and paid seperately
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 connected to earthing test point and including dismantling complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:2:4 type B1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
S&F steel tubular swaged poles conforming to IS-2713, complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-31 (9 m long) and including painting with two coat of aluminium paint over a coat of primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and 03 Nos band / strips with white synthetic enamel paint, 30 cm wide each at a distance of 30 cm from top of plinth block and numbering of poles including taking down complete all as specified and directed. Note:- Excavation, earth work and PCC work will be measured and paid for separately under respective items. Make of Pole:- Calcutta Poles & Tubes / Skipper Limited / Jindal Steel / National tubing Co / Bombay tube & Store Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F PVC insulated 3 core multistranded sheathed cable with 1.5 Sqmm copper conductor for connection of street / security light etc, including taking down complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
S&F weather proof cable junction box of size not less than 250 mm x 200 mm x 100 mm with terminals, IP 66 (minimum), suitable for outdoor installation, suitable for 10 to 25 sqmm cable, including 01 No 5/6 Amp MCB, 50 Amp rated 3 pole connector, fixing arrangement with MS flat of size 25 x 3 mm with necessary nuts, bolt and washers & taking down complete all as specified and directed. Make :- Hensel / Sintex Industries Ltd. / C&S electric Ltd. / National
M&L for bracket suitable for street light made out of GI pipe light grade of 40 mm bore & 1.50 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down complete all as specified and directed. Make of Pipe :- Tata / Jindal Steel / Surya Roshni Ltd. / Bhushan Power & Steel Ltd. / M/s APL Apollo Tubes Ltd
M&L preparation of old painted surface of existing 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the colour code, writing pole details & applying one coat of white wash on pole coping complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F 2 inches wide reflective tape with high-performance adhesion, water resistant including fixing around the circumference of pole at an approximate height of two meters complete all as specified and directed. Note:- Unit rate quoted shall deemed to include cost for arrangment of all T&P such as ladder etc. reuired.
M&L for disconnecting, removing 0.75 HP to 2 HP motor 415 Volts, 50 Hz, 3 Phase from high mast gear box unit and carryout necessary rewinding of the burnt core with super enameled copper wire of appropriate gauge, greasing of bearings, rotating shaft, replacing worn out nuts and bolts complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling defective lantern carriage from High mast of any height, check for any short circuit / burnt wire, disconnecting and replacing the wires from light fittings and driver unit and re-fix the light fittings and re-align the carriage and light fittings as required complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of broken / defective SS wire of size 6 mm 7/19 construction complete, after disconnecting and dismantling the SS rope securely from the high mast alongwith replacing and fixing U-clips, fasteners as required and testing & commissioning complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulated 3 core multistranded sheathed cable with 2.5 Sqmm copper conductor for connection of street / security light etc, including taking down complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
S&F in repair mono-crystalline solar panels of 125-240 Watt (Pmax) capacity including taking down old damaged solar panels from position complete all as specified and directed by Engineer-in-Charge.
M& L for Solar LED light fittings with in-built MPPT charge controllers including taking down the light fittings from the pole complete all as specified and directed by Engineer-in-Charge.
S&F on-load change over switch 400 Amp capacity, four pole, 415 volts with SS enclosure including taking down complete all as specified and directed. Make:- L&T / Legrand / ABB / Siemens / Schnieder / Havells India Ltd. / Indo Asian
All as per Sl Item No. 53.00 but capacity of 200 Amp
All as per Sl Item No. 53.00 but capacity of 100 Amp
S&F on-load change over switch 630 Amp capacity, four pole, 415 volts, manual change over & open execution including fixing in existing panel and necessary modification in the panel (if reqd) & taking down complete all as specified and directed. Make:- L & T / Legrand / ABB / Siemens / Schnieder / Havells India Ltd. / Indo Asian
S&F 4 Pole power contactor in replacement 450 A , AC1/400 Amps AC3 capacity for contactors with dust cover in DG set panel with necessary connections complete all as specified and directed. Make: L&T / Indoasian / GE / BCH / HPL / C&S / ABB / Siemens
All as per Sl Item No. 57.00 but capacity of 380 A , AC1/330 Amps AC3
S&F in repair dry maintenance free battery 12 V, 65 AH including copper terminal lugs complete all as specified and as directed by Engr-in-Charge. Make:- Exide / Amron / Luminous / Amaraja
M&L for repair of DG Set of 30 to 200 KVA capacity by dismantling the sub-assemblies such as fuel pump, fuel injection, wood ward governor, turbo-charger, radiator, oil cooler, engine heads, rocker arms, self starter, dynamo engine wiring, terminal contacts and safety contacts etc. including replacement of spare parts as required and re-assembling the sub-assemblies after carrying out necessary repairs including testing and commissioning complete all as specified and as directed. Note:- (i) Supply only spare parts of existing makes required shall be measured and paid separately under relevant items. (ii) Repairs and calibration of sub-assemblies shall be measured and paid separately under relevant items.
All as per Sl Item No. 60.00 but for DG Set of 250 to 500 KVA capacity
M&L for repair & calibration of wood ward Governor as per calibration procedure and norms for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 62.00 but for DG Set of 250 to 500 KVA capacity
M&L for repair & calibration of turbo super charger as per calibration procedure and norms as per manufacturer’s guide lines including replacement of Turbo supply & discharge hoses and clamps and de-scaling of Turbo charger for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 64.00 but for DG Set of 250 to 500 KVA capacity
M&L for Repair & calibration of Fuel Pump & Injectors as per calibration procedure and norms as per manufacturer's guide lines including replacement of unserviceable 'O' rings, Plungers and cups etc. for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 66.00 but for DG Set of 250 to 500 KVA capacity
M&L for Repair & calibration of Self starter including re-winding of Commutator, replacing Carbon brush set, carbon brush holder, King Pins Holders, armature check nuts, body screws, clutch plate assembly and solenoid etc. as required for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 68.00 but for DG Set of 250 to 500 KVA capacity
M&L for De-scaling of radiator by dismantling the upper & lower tank and cleaning the core pipes with cleaning chemicals, components and arrest the leaking core by brazing / dummy with lead including cleaning of upper & lower tanks and replacing the upper and lower gaskets and required nuts, bolts, refixing the same including testing and painting for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 70.00 but for DG Set of 250 to 500 KVA capacity
All as per Sl Item No. 70.00 but for DG Set of 1010 KVA capacity
M&L for maintenance and servicing of alternator of any make & capacity by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid up to the satisfaction and checking of diodes, excitation winding, isolation transformer and AVR panel applying Dr. Beck paint for insulation improvement over the strips / winding and drying till getting satisfactory insulation resistance and re-fixing the covers and testing for DG Set of 30 to 200 KVA capacity complete all as specified and as directed.
All as per Sl Item No. 73.00 but for DG Set of 250 to 500 KVA capacity
All as per Sl Item No. 73.00 but for DG Set of 1010 KVA capacity
Supply, calibration, installing, setting, testing and commissioning of AVR upto 1010 KVA Dg set, 415V, 3 Phase, 4 wire system, Digital type, Voltage regulation : 10% of rated voltage, frequency setting : 50/60 cycle, stability, doom settings, excitation voltage and current to be matched with OEM instructions complete all as specified and as directed.
Supply, replacing, testing & calibrating and commissioning of engine oil pressure gauge, dial type, Analog type, range 0 to 10 Kg/cm2, resolution 0.25 Kg/cm2, control wiring complete all as specified and directed by Engineer-in-Charge.
Supply, replacing, testing & calibrating and commissioning of coolant temperature gauge, dial type, Analog type, range 0 to 150ºC , resolution 5º C control wiring complete all as specified and directed by Engineer-in-Charge.
Supply, replacing, testing & calibrating and commissioning of Ammeter, dial type, Analog type, range -150 to +150 Amps, resolution 10 Amps control wiring complete all as specified and directed by Engineer-in-Charge. Make :- Havells India Ltd. / HPL India Ltd. / L&T / AE / Schneider / BCH
Supply, replacing, testing & calibrating and commissioning of Hour run meter cum tachometer, dial type, Analog type, range3 to 3600 RPM, resolution 50 RPM control wiring complete all as specified and directed by Engineer-in-Charge.
M&L for strip opening AMF panel of 30 to 200 KVA capacity DG set, checking, inspecting, calibrating AMF panel, replacing the burnt copper wiring with suitable flexible copper wire, inspecting the contactor coils & replacing the defective coils, cleaning the fixed / moving contacts with CTC complete including setting of AVR of Alternator including testing & commissioning all as specified and directed.
All as per Sl Item No. 81.00 but for DG Set of 250 to 500 KVA capacity
All as per Sl Item No. 81.00 but for DG Set of 1010 KVA capacity
S&F in repair dry maintenance free battery 12 V, 180 AH including copper terminal lugs complete all as specified and as directed by Engr-in-Charge. Make:- Exide / Amron / Luminous / Amaraja
All as per Sl Item No. 84.00 above but 12 V, 90 AH battery
M&L for carrying out 'B' check for DG set of capacity 1010 KVA after 06 months or 250 hrs running, whichever is earlier as per manufacturer's recommendation including replacement of fuel filters, air filters, oil filters, 'O' rings, engine oil, gasket, coolant etc complete all as per manufacturers instructional manual and all as directed by Engg-in-charge. Make of Engine: Cummins / Kirloskar Note:- Unit rates quoted against this item shall be considered to include cost of fuel filters, air filters, oil filters, 'O' rings, gasket, engine oil and coolant consumed etc.
All as per Sl Item No. 86.00 above but for DG Set of 320 KVA capacity
All as per Sl Item No. 86.00 above but for DG Set of 250 KVA capacity
All as per Sl Item No. 86.00 above but for DG Set of 125 KVA capacity
All as per Sl Item No. 86.00 above but for DG Set of 100 KVA capacity
M&L for replacement of air cleaner filter suitable for DG Set of 1010 KVA capacity & as per OEM complete all as specified and as directed by Engineer-in-Charge.
All as per Sl Item No. 91.00 above but for DG Set of 320 KVA capacity
All as per Sl Item No. 91.00 above but for DG Set of 250 KVA capacity
All as per Sl Item No. 91.00 above but for DG Set of 60 to 125 KVA capacity
Supply only Engine oil 15W40 or as per recommendation of engine manufacturer all as directed. Make : Servo / Bosch / Castrol / Valvoline / HPCL
Supply & topping up of radiator coolants as per the recommendation of engine manufacturer all as directed. Make : Servo / Bosch / Castrol / Valvoline / HPCL
S&F in repair self starter motor for DG set of 100 to 1010 KVA capacity as per OEM complete all as specified and as directed by Engr-in-Charge.
S&F of 100 to 500 KVA engine controller consisting of following parts including taking down old one :- (a) Seep Sea (UK) Controller- 01 No (b) AVR - 01 No (c) Governor Cord - 01 No (d) HWT Sensor - 01 No (e) LLOP Sensor - 01 No (f) Software updating with Laptop - 01 No (g) Programming with Laptop - 01 No (h) Necessary auxiliary relays / relay cord - 01 Job (j) Necessary wiring modification, testing and commissioning - 01 Job
M&L for preparation of old painted external surfaces of DG set of capacity 500 KVA including alternator, radiator support channels, panel board, connected equipments complete and spray painting with two coats synthetic enamel paint complete all as specified and as directed. Note:-Rusted surfaces of DG Set shall be scraped with sand paper and shall be applied with one coat of zinc chromate primer before application of paint and unit rate quoted against this item shall be considered to include this aspect.
S&F in repair fuel and lub oil hose pipe set with clamp / clip etc suitable for DG Set of 82.5 to 100 KVA capacity and make as per OEM complete all as specified and as directed.
All as per Sl Item No. 100.00 above but for DG Set of 125 KVA capacity
All as per Sl Item No. 100.00 above but for DG Set of 250 KVA capacity
All as per Sl Item No. 100.00 above but for DG Set of 320 KVA capacity
All as per Sl Item No. 100.00 above but for DG Set of 1010 KVA capacity
M&L for Servicing AHU of 11 TR capacity (Package AC), with and including dismantling units, sheet metal parts, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connection, cleaning of air filters, greasing of blower motor, replacement of un serviceable bearings, Painting of blower motor, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over one coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge.
M&L for complete Servicing the condensing unit of 5.5 TR capacity (Package AC), with and including dismantling units, sheet metal parts, blowing out the dust, spraying the organic based scale removing agent Vaniklin at the appropriate ratio to the condenser fan area till removal of complete dust & scale, flushing through for proper air flow across the coil, cleaning of expansion valve; greasing of blower motor, checking of electrical connections, greasing of motor bearing renewal of all corroded sheet metal screws, applying synthetic enamel paint over one coat of primer on the rusted portion and testing & commissioning the unit all as specified and as directed by Engineer-in-Charge.
M&L for complete leak testing the indoor and outdoor units, complete refrigerant pipe with Nitrogen gas, locating the leaks, rectify the leak by brazing / welding and pressure testing the complete system of 5.5 TR Capacity of air cooled package AC system all as specified and as directed by Engineer-in-Charge.
Supply and charge refrigerant gas R407C (Environmental friendly) including leak testing the system, arresting the leaks with necessary materials like gasket / ‘O’ rings/ washers all as specified and directed by Engineer-in-Charge. Make : Mafron / Freon / Floron
S&F PCB Board suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F Condenser unit suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F Outdoor fan motor suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F Indoor fan motor suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F Outdoor fan blade suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F blower unit for Indoor suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
Supply only compressor oil as specified and directed by Engineer-in-charge.
S&F Expansion valve suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge.
S&F over load protection relay suitable for 5.5 TR package type AC unit and of make as per OEM including taking down complete all as specified and as directed by Engineer-in-charge. Make: L&T / Schnieder/ GE / BCH / C&S / ABB / Siemens
S&F in repair scroll compressor suitable for 5.5 TR capacity package type AC unit & of make as per OEM including sealing of the compressor with brazing complete all as specified and directed by Engineer-in-Charge. Make:- Blue star / Voltas / Carrier
S&F in repair 3 pole MNX power contactors in various AC plants including necessary control wiring all as specified and as directed by Engineer-in-Charge.
SRIESWARI ENTERPRISES
M/s.DSRK CONSTRUCTIONS
ALPHA ENGINEERING CONSTRUCTIONS
ANAND ENTERPRISES AND ENGINEERS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .