Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.3 L+₹3.9 L (11.3%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹39.8 L+₹5.4 L (15.6%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹31.3 L
EMD Value
₹62,500
Closing Date
3 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL AMAN BHARDWAJ
Military Engineer Service GE AF No 1 Jamnagar 361003
PROVISON OF POWER SUPPLY , FLAME PROOF LIGHT, SPECIAL REP OF CABLE AND CERTAIN MINOR WORKS AT AF STATION SAMANA UNDER GE AF JAMNAGAR NO.1
2023_MES_592991_1
8222/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF JAMNAGAR NO 1
6 documents required · 6 mandatory
₹500
Yes
GE AF JAMNAGAR NO 1
₹62,500
Yes
14 Jul 2023
3 May 2023
5 Jun 2023
3 May 2023
3 Jun 2023
20 May 2023
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting outt in solft/loose soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dence soil.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / disintegrated rock.hard/dence soil.
M&L for Cement concrete Type D-2, 1:4:8 (using 40mm graded aggregate) in foundations, filling and mass concrete.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exc 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall or pillars all as specified and directed.
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F anodized aluminium three track Power coated of any color ( thickness of powder coating not less than 50 micron) sliding window with three sliding shutter , the size of outer frame three track 92 x 31.5x 1.20mm ( using two track for glazed window shutter and one track for wire gauged ) , the section shutter size 37x 18x 1.2mm)and glazing with 4 mm thick glass ( plain/floated) including all-around suitable rubber gasket and MS wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed on aluminum flat and inserted in the frame of shutter with tracking arrangement each sliding window shall be provided with one number handle including locking arrangement & 2 numbers’s sliding rollers of nylon with including all necessary fittings complete all as specified and directed by Engineer-in-Charge
S&F rolled Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165
S&F 30mm thick.Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 100 mm size butt hinges medium weight, cold rolled mild steel, and fixed complete all as specified & directed.
S&F 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed.
S&F 150 mm in size aluminium handles cast type anodized complete all as specified & directed.
S&F 250 mm in length Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
M&L for preparing of new or previously untreated surfaces of wood or wood based materials of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified & directed.
M&L for preparing of new or previously untreated surfaces of steel or iron of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified & directed.
S&F rolled mild steel Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe.290.Gde-E-165
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M & L for rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces.
M&L for preparation of new plastered surface of wall and applying two coats of Distemper oil emulsion over one coat of primer, complete all as specified and directed
M & L for rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces.
M&L for preparation of new plastered surfaces of wall incl pilasters / cornices etc and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS-15489 : 2004 : Alkali & fungal resistant, dirt resistant, exterior paint of required shade (company Depot Tinted) with silicon additives @1.43 Liters/10 Sqm over and including priming coat of exterior primer applied @ 0.90 Litre / 10 Sqm.
M&L for cement concrete type B1 1:2:4 (20 mm graded aggregates) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed .
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
Ditto as per item 23 above Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M & L for Hardcore of Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete type D-2,1:4:8 (40 mm graded aggregate) as in subbase complete complete all as specified and as directed by Engr-in-Charge.
M&L for 100 mm thick cement concrete type B-2,1:2:4 (40 mm graded aggregate) as in floor / hard standing,etc complete all as specified & directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of rubbish outside MD land
M&L for 75 mm thick cement concrete type B-2,1:2:4 (40 mm graded aggregate) as in plinth protection,etc complete all as specified & directed.
M & L for Damp proof course of 40mm thick in cement concrete 1:2:4, type B-0 to horizontal or vertical surfaces including necessary formwork complete.
Supply only Liquid water proofing compound
M&L for Cutting holes in stone walls built in cement mortar or cement lime mortar for inserting holdfasts or any other required work and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required; depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall should exc one brick but not exc two brick complete.
Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out soft/loose soil, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in any type of soil removing surplus soil to a distance n exc 50 m complete all as specified and directed.
M&L for Cement Concrete Type C2 1:3:6 (using 40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasketetc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F Powder coated of any colour (Thickness or powder coating not less than 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F 12 mm Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work.
S&F sheet glass 4 mm thick ordinary quality (plain/floated) and glazing with oil putty / wooden beads / aluminium glazing clip in square exc. 0.5 sqm in each pane complete all as specified & directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose all as specified and directed
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soft/loose soil all as directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soft / disintegrated rock all as directed.
Removing excavated soil to a distance exc 50 m but n.exc 100 m and depositing where directed at a level n.exc 1.5m above the starting point.
Removing excavated soft rock to a distance exc 50 m but n.exc 100 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009) for measurement purpose thickness of sand after punning down will be considered.)
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed .
S&F Tubes 32 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors / trenches.
S&F Tubes 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors / trenches.
Supply and lay in trenches / walls / poles, LT power cables, 16 sqmm, 4 core, aluminium stranded conductor, XLPE Insulated, cores laid up, PVC inner sheathed, armoured with galvanized steel strip, extruded PVC type ST2 outer sheathed, 650/1100 V grade all as specified and directed.
Supply and lay in trenches / walls / poles, LT power cables, 120 sqmm, 4 core, aluminium stranded conductor, XLPE Insulated, cores laid up, PVC inner sheathed, armoured with galvanized steel strip, extruded PVC type ST2 outer sheathed, 650/1100 V grade all as specified and directed.
Disconnecting & Taking out LT underground cable (aluminium conductor of size 90/120 sqmm 3.5/4 core) from trenches including cable cover, tubes if any, etc, compete, all as specified and directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4way, Horizontal type with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, double door type 415 volts, fixed flush to wall complete all as specified and directed.
Supply and fix MCCB 63 Amp, Four Pole, breaking capacity 25 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix in repairs MCCB 200 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, adjustable thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCB 160 Amp, Four Pole, breaking capacity 35/36 KA, 415 V - 50 Hz, adjustable thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repairs MCCB 100 Amp, Four Pole, breaking capacity 25/36 KA, 415 V - 50 Hz, adjustable thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix MCCB 250 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed thermal and magnetic setting type, fixed in existing panel & connecting complete all as specified & directed by Engr in charge.
Supply and fix MCB’s single pole & neutral, 40 Amps, 230 volts with ‘C’ curve 10 KA, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s Single pole 6-32Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole & neutral, 16Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole & neutral, 40-100Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole & neutral, 32Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply install testing and commissioning of diesel Engine driven generating set 25 KVA capacity, 3 phase, 4 wire, 440 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures having salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application/installation. Integrated design thereby facilating/easy handling installation and shifting of... .
...the eqpt at site. The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2:4) type B-1 foundation as recommended by manufacturer , Vibration pad sand cushioning around PCC foundation etc all and Tools and spares as provided by manufacturer all as specified and as directed with the following specifications :-.
(A) ENGINE : Water cooled with radiator diesel Engine (confirming to IS : 10001/10002) of 1500 RPM capacity to match the 25 KVA alternator under NTP conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS 6514/ IS 10001 / 10002 the Engine shall consist of the following :-
(i) Fly wheel
(ii) Flexible coupling with guard bolts and nuts etc.
(iii) Air cleaner heavy duty dry type
(iv) Radiator with guard and water pump engine mounted.
(v) Dynamo of suitable capcity (vi) Air cleaner heavy duty dry.
(vii) Fuel injuction pump.
(viii) Radiator fan (Blower type) with guard.
(ix) Electronicv/ A1 class governer.
(x) Fuel filter (Mounted).
(xi) Lubricating oil filter (mounted).
(xii) 12V self regulating alternator belt driven by engine
(xiii) Exhaust silencer heavy duty residential type.
(xiv) Corrosion resistor / scale inhibitor.
(xv) Starter 12 V DC.
(xvi) Lubricating oil cooler.
(xvii) Lubricating oil pump (Gear type).
(xviii) Turbo Charger
(xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet.
(xx) Instrument panel complete with the following:-
(a) Auto mannual starting switch with key.
(b) Lubricating oil tempreture gauge.
(c) Lubricating oil pressure gauge.
(d) Water tempreture gauge.
(e) Battery charging ammeter.
(f) Battery charging indicating lamp.
(g) Hour meter with RPM indicator.
(h) Safety control against high temperature of water.
(j) Safety control against low lubricating oil pressure.
(k) Over speed stop with double driven adoptor.
(B) BRUSH LESS ALTERNATOR
(i) Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364
(ii) Type :- Self excited self regulated with automatic voltage regulator.
(iii) Rating :- 25 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition 3
(iv) Speed :- 1500 RPM
(v) System :- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz.
(vi) Connection :- 4 wire star connected.
(vii) Enclosure :- Screen protected dip proof.
(viii) Ventilation :- Self ventilated
(ix) Insulation :- Insulation Class H
(C) AUTOMATIC CONTROL PANEL
Built in AMF panel for automatic ON during power failure and off while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 16 SWG , over an angle iron frame made out of 50 x 50 x 6 mm angle with removable side cover hinged front panel and rear panel of easy accessibility complete with internal wiring of suitable size copper conductor cable and cable glands for external connection and comprising of following :-
(i) Main in coming MCCB 4 pole 415 volts suitable for 25 KVA DG set (Recommended by Manufacturers)
(iv) Frequency metre digital type - 01 No
(v) HRC type instruments fuse
(vi) LED type signal lamp for DG set/ commercial power on off indication - 06 nos
(vii) Copper bus bar of suitable size.
(viii) Circuit diagramed plate
(ix) CT operated KWH metre - 01 No
(x) Power factor meter digital type - 01 No
(xi) Reverse power relays and suitable contactors - 01 Set
(xii) mannual mode, auto mode, test mode - 01 set
(xiii) single phase preventer - 04 Nos
(xiv) Battery charger
(xv) All relays/power contactors of suitable size and capacity
(D) ONE SET OF ACCESSORIES COMPRISING OF :-
(a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 16 hrs running at full load including necessary piping.
(i) Level indicator on fuel tank
(ii) Drain plug
(iii) MS class 'C' piping for inlet from pump to tank of engine
(iv) Fuel strainer
(v) Air vent
(b) BATTERY (As recommended by manufacturers)
(C) BASE PLATE (Fabricated out of MS channels ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer)
Note:- the quotted rate shall include construction of foundation/plinth of PCC 1:2:4 type B-1 of suitable size and 0.5 mt below ground and 1.5 metre above ground.
Supply and fix, testing and caliberation of voltage stablizer for automatic operation three phase naturally air cooled indoor type amd designed for input variation 340V-460V wit output voltage stablized with 415 of +- 2.5% variation and speed correction of 8 V per sec and of capacity 10 KVA
Material and Labour for Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 50x6mm.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm copper strip
Material & Labour for point wiring with 4 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M&L for sub main wiring with four run of five core PVC insulated copper cable multi-stranded conductor 6 Sqmm drawn through in and including Non metallic PVC conduit not less tha 40mm dia into wall / ceiling with all accessories with 6.0 Sqmm PVC insulated unsheathed copper conductor as earth wire, connected to common earth dolly complete all as specified and as directed. Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
M & L for Switch socket combination 3 pin 16A, flush type including connecting complete.
M & L for 16 Amp, 5 pin ,3 phase Industrial Female socket box with metal enclosuree, including connecting complete.
Material and labour of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Note : The Quoted rate for above item includes the cost of following : - (a) Earth electrode. (b) Main earthing lead from earth electrode to test point of 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust, common salt and adequate quantity of chemical (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode.
(g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point. (l) Connecting lead from test point to main
Material and labour of Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip 25 x 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Note : The Quoted rate for above item includes the cost of following : - (a) Earth electrode. (b) Main earthing lead from earth electrode to test point of 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust, common salt and adequate quantity of chemical (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode.
(g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) Test point. (l) Connecting lead from test point to main
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC capping & casing not less than 25 mm wide, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC surface type terminal box of suitable size with PVC cover complete.
All as per item No 74 above but wiring for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
M&L Switch piano, flush type single pole, one way 6 Amp
M & L for Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal, including connecting complete.
S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed by Engg –in-charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm
Supply and fix oscillating and tilting wall mounted fan 400mm sweep ,1350 RPM mm sweep AC, 240 volts, metal body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete.
M&L for Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, including connecting complete.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.
Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete.
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete.
M&L for Cutting hole in existing stone masonary wall built in cement mortar by means of stone cutter or other means making hole suitable for fixing of Ventilating / exhaust fan up to 300/380mm sweep, including making good the disturbed surface in cement mortar 1:4, to match with existing surface complete all as directed by Engr-in-Charge.
Supply and Fix Antisuicide Fan rod ( 15'') ,Mspipe zinc plated 19 mm OD,1.8+-0.05 mm thick, spring set grade 3 carbon steel material zinc plated. MSME tested for performance test and opening at impact load of 22kgf+ and spring hidden in the pipe will expand to about 1 mtr or more including taking down and refixing fan complete all as specified and directed.
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing of flame proof Aluminum exhaust fan 450 mm sweep, RPM 1400 with copper winding & fitting including installation on wall/ceiling complete all as specified and directed.
Supply and fix surface plastic box of 3 module for mounting switch/socket and connecting all wires connection as in working condition all as specified and directed.
Supply and fix 3 top plate with support plate of modular fitting complete.
Supply and fix MCB’s single pole and neutral 6 to 32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply, installation, commissioning and testing of Analogue Addressable Fire Alarm Control Panel along with loop card and 12 volts 7 ah battery including detector wise configuration facility 200 Event storage with Real Time Clock, upto 192 grouping facility, Pre Alarm Action, Programmable Detector sensivity. Device type verification, Earth fault annunciation facility at 0 ohms, Double Address Sensing, Loop wise device test, 40 x 4 characters LCD display 4 numbers of loop card and 254 devices in any combination per loop. Day / Night mode facility. USB 2.0 interface for PC connectivity. Rs. 485 Communication facility for Network / Repeater / MODBUS / BACnet.
........…….Programmable Auto Silence Facility. Programmable AC Loos Delay. Programmable Silence Inhibit. Two No’s of programmable inputs. Battery low audio, visual warning. Three programmable Form C relay for Fire, Fault and Supervisory. Primary Power 120 / 220 VAC+10% - 15%, 60/50 Hz. Standby Power 24V DC (2Nos. of 12V 40Ah Max, built in for 12Ah) Sealed Lead acid battery operation condition operation temperature 0 - 49º C / 32 - 120º F Relative Humidity 93 ± 2% RH (Non-condensing) at 32 ± 2º C /90 ± 3º F.
Supply, installation and commissioning and testing of Addressable Smoke detector with base with Binary coded address setting. Dual Led's for 360 visibilty. Sleek low-profile housing design. Regular 100mm base. IP rating: Ip-42.
Supply, installing, testing and commissioining and testing factory made and tested (including CPRI type test certified) LT panel (KIOSK) in replacement of old Main LT panel outdoor type, platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC suplly system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 1200 amps rating installed on porcelain insulators......../-
........……The panel shall be dust and vermin proof, with IP 54 protection, made of 3.15mm CRCA MS sheet 75mm x 30mm thick MS Channel frame, duly powder coated finished. Front and back opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal. The scopeof work includes provision of the following...../-
........…….:- Incoming (a)ACB 4 pole 800 Amps,50 KA,415V-01 Nos (b)Bus bar (Aluminium)1200 Amp,4pole,for incoming supply Outgoing (a)MCCB 4 pole 250 Amps,36KA,415V 50 Hz-03 Nos (b) MCCB 4 pole 400 Amps,36KA,415V-03 Nos (c) MCCB 4 pole 160 Amps,25 KA,415V-04 Nos (d) MCCB 3 pole 63 Amps,25 KA,415V-01 Nos (c) Existing cable (For various Bldg supply cable of sizes) connect with busbar properly with suitable size copper Lug. (e) digital panel meter showing KVAr, K W Power factor, current pahse voltage, line current including CTs and PTs. (f) Phase indication LED lamp one set.
Supply, install, testing and commissioining and testing factory made and tested (including CPRI type test certified) LT feeder pillar box (KIOSK) in replacement of old LT feeder outdoor type,platform mounted, suitable for 415 Volts 3 phase 4 wire, 50 Hz AC suplly system, all as specified and directed, having bus bar chamber with insulated Aluminium bus bars 400 amps rating installed on porcelain insulators......../-
........……The panel shall be dust and vermin proof, with IP 54 protection, made of 3.15mm CRCA MS sheet 75mm x 30mm thick MS Channel frame, duly powder coated finish. Front and back opening type with aprons for cable entry with double door shutter and locking arrangement, danger plate and earthing terminal. The scopeof work includes provision of the following...../-
........…….:- Incoming (a)MCCB 4 pole 200 Amps,36 KA,415V-01 Nos (b)Bus bar (Aluminium)400 Amp,4pole,for incoming supply Outgoing (a)MCCB SPN 32 amp 16 KA,415V 50 Hz-03 Nos (b) MCCB 4 pole 100 Amps,25KA,415V-04 Nos (c) MCCB 4 pole 80 Amps,25 KA,415V-01 Nos (c) Existing cable (For various Bldg supply cable of sizes) connect with busbar properly with suitable size copper Lug. (e) digital panel meter showing KVAr, K W Power factor, currevt pahse voltage, line current including CTs and PTs. (f) Phase indication LED lamp one set.
Sagathiya Builders
Jagdamba Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .