Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC FLAT NO 101 UGF FRONT LHS RZ B 49A KAILASHPURI PALAM COLONY NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | ₹3.2 Cr | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹3.6 Cr+₹33.0 L (10.2%)Rejected-Finance | ₹3.6 Cr+₹33.0 L (10.2%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.6 Cr+₹35.5 L (10.9%)Rejected-Finance | ₹3.6 Cr+₹35.5 L (10.9%) | L3 | Rejected-Finance L3 |
| 4 | L4₹3.7 Cr+₹46.6 L (14.3%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | ₹3.7 Cr+₹46.6 L (14.3%) | L4 | Rejected-Finance L4 |
Tender Value
₹3 Cr
EMD Value
₹3.8 L
Closing Date
5 Sept 2023, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, Kalyan Marg, Banipark, Jaipur-06
PROVN OF 08 OFFRS MD ACCN (MAJ) AT KOTA MIL STN
2023_MES_602367_2
CWE/KOTA/82220/E8
Open Tender
Civil Works
Lump-sum
330 days
Kota
As per NIT
7 documents required · 7 mandatory
₹2,000
Yes
GE KOTA
₹3.8 L
Yes
12 Oct 2023
8 Aug 2023
7 Sept 2023
8 Aug 2023
5 Sept 2023
23 Aug 2023
8 Aug 2023 - 22 Aug 2023
Amount
Lump sum price worked out by contractor for "BUILDING WORKS" (including internal water supply and internal electric supply) as listed in Schedule `A' Part-I* Above/below the lump sum price inserted by the MES in Schedule `A' Part-I
Lump sum price worked out by contractor for "INTERNAL WATER SUPPLY" as listed in Schedule `A' Part-II *Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-III *Above/below the lump sum price inserted by the MES in Schedule `A' Part-III
Lump sum price worked out by contractor for "HOT WATER SUPPLY" as listed in Schedule `A' Part-IV *Above/below the lump sum price inserted by the MES in Schedule `A' Part-IV
Lump sum price worked out by contractor for "SPECIAL ITEM OF WORK" as listed in Schedule `A' Part-V *Above/below the lump sum price inserted by the MES in Schedule `A' Part-V
Lump sum price worked out by the Contractor for "ROAD / PATH / CULVERT" as listed in Schedule ‘A’ Part-VI *Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VI
Lump sum price worked out by the Contractor for "EXTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-VII *Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VII
Lump sum price worked out by contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-VIII *Above/below the lump sum price inserted by the MES in Schedule `A' Part-VIII
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-IX *Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-IX
Lump sum price worked out by contractor for "Area Drainage" as listed in Schedule `A' Part-X *Above/below the lump sum price inserted by the MES in Schedule `A' Part-X
Lump sum price worked out by contractor for "SITE CLEARANCE AND EARTH WORK " as listed in Schedule `A' Part-XI *Above/below the lump sum price inserted by the MES in Schedule `A' Part-XI
Lump sum price worked out by contractor for FENCING AND GATE " as listed in Schedule `A' Part-XII *Above/below the lump sum price inserted by the MES in Schedule `A' Part-XII
Lump sum price worked out by the Contractor for Schedule `A' Part-XIII (MISC SCHEDULE) (rate against Srl No.13.01 to 13.16 shall be quoted by the Contractor)
M & L for Continous 40 to 50 mm thick roughly hammer dressed stone edging, with width 450 mm laid dry on end vertically ( length of stone edging shall not less than 600 mm) complete all as specified & directed.
M&L for Steel gate 5.45 METRE wide and 2.00 METREs height with RCC columns including all necessary excavation in any type of soil and painting complete all as specified & shown in drgs.
M&L for Cutting of existing GI pipe line and inserting Tee 50x50x50 mm for taking branch connection including necessary joints and fittings complete all as specified and directed by engr in charge.
S & F terminal box made of PVC Box of size 210x 155x92mm fix on pole by means of mild steel clamps with bolt and nuts, provn for cable entry for incoming and outgoing including MCB 6-32-1Nos and 4 way connector-1nos Amps necessary connection duly fixed with and including cable glands threaded tye IP65 made of polymide with lock nut complete all as specified. Make : Hensel Cat No KF PV 0500 or equivalent as approved by GE
M&L for road/ hard surface cutting for laying of cable/ pipe including making good of surface complete all as specifeid and directed by Engineer in charge
S & F in street Meduim brackets 40 mm dia GI pipe medicum grade upto 1.2 mtr long bend to shape including flat iron clamps and sutable nuts and bolts for fixing street light bracket in pole complete all as specified & directed
Supply and fixing PVC insulated unsheathed copper conductor cable 1.5 sqmm 3 core from street light fitting to juction box to on poles of 9 mtrs and making nececessary connection both at junction box and street light fittings incl suitable size PVC conduit and fixing accessories complete all as specified & directed
M&L for Wiring with TV coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a copper wire net for TV antenna from terminal boxes to TV socket complete all as specified (conduit pipe and fittings shall be inclusive in the unit rate ).
M&L for Wiring with twin core PVC insulated sheathed cable with copper conductor having single strand of 0.6 mm dia taped for telephone wiring from terminal box to telephone socket complete all as specified (conduit pipe and fittings shall be inclusive in the unit rate )
M&L for GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 3 pin telephone socket outlet flush type duly marked with symbol of telephone and 3 mm thick plastic laminated sheet cover complete for telephone connection all as specified
M&L for GI box flush mounted 100mm x100mmx100mm having holes for 20 mm conduit entry including 2 pin TV socket outlet flush type duly marked with symbol of TV and 3 mm thick plastic laminated sheet cover complete for TV connection etc complete all as specified and directed
S&F Vertical TPN distribution boards made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating 4 way, double door, IP43, as per IS 8623-III, impact resistance IK09 with the provision of 200 A rated busbar, blanking plates with all electrical connection as specified and comprising of the following:- (a) MCCB 100 A - 01 No (Incomer) (b) MCB TP 25 A - 04 Nos (o/g) (c) MCB SP 10 A 'C' curve - 01 No (o/g)
S&F LED batten light fitting 20 watt including LED tube 4 feet long complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 8/10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified & directed
S&F LED batten light fitting 10 watt including LED tube 2 feet long complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 8/10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin etc complete all as specified and directed
S&F LED mirror light fitting 10 watt including LED tube complete suitable for fixation on wall with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 8/10 watt ± 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15 % lumen output should not be less than 90 lumens per watt, total input voltage range 140 - 280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin etc complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 200/230 mm sweep with, blades, and frame and louvers including suitable size of wooden frame with circular opening for mounting exhaust fan in the ventilation opening complete all as specified and as directed.
S AND A ENGINEERS CONSTRUCTION CO
M/S TIKAM CHAND JAIN
Pioneer Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .