| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹35.8 L+₹67,401 (1.92%)Rejected-AOC 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC R | |
| 3 | L3₹42.0 L+₹6.8 L (19.4%)Rejected-AOC | L3 | Rejected-AOC R |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
31 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF SUMMER WINTER APPLIANCES IN SOUTH COMPELEX AT IMA DEHRADUN
2021_MES_491183_2
GE/IMA/100/2021-22 9162/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE IMA Dehradun
₹84,000
Yes
12 Feb 2022
8 Jan 2022
2 Feb 2022
8 Jan 2022
31 Jan 2022
17 Jan 2022
60 days
Amount
Dismantling and taking out the non-functional Water coolers of any description, any make and in any position of capacity 40 ltr to 150 ltr, including disconnection of water line connections, cleaning and servicing of the water cooler , checking all serviceable parts, necessary brazing, reassembling all parts of water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the water cooler in working condition during the entire contract period and further for defects liability period.
Checking of leakage of refrigerent system of water cooler of capacity 40/80/120/150 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom leg suppots and testing and vaccumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :- (i) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item (ii) The new fixed spares/ parts shall be paid as "supply only" as specified / mentioned here-in-after and fixing charges for new/ repaired items are deemed to be included under this item
Supply only Condensor fan Motor suitable for Water cooler of capacity 40/60/80/120/150 ltr duly connected and testing complete in position all as directed.
Supply only over load protector suitable for water cooler of capacity 40/60/ 80/ 120/150ltr complete all as directed.
Supply only starting capacitor conforming to IS - 2193-1975 AC 230 Volts in Aluminium container capacity 40/60 Mfd complete all as specified and directed.
Supply only running capacitor 25 mfd complete all as specified and directed.
Supply only running capacitor 10 Mfd complete all as specified and directed.
Supply only starting capacitor 10 mfd complete all as directed.
Supply only thermostat switch suitable for water cooler capacity 40/60/80/120/150 ltr and any make complete all as directed and approved by GE.
Supply only starting relay complete suitable for water cooler of different capacity and any make complete all as specified and directed.
Supply only push/lifting type self closing tap of 15mm dia chromium plated suitable for Usha Sriram/Sidwal/Voltas/Bluestar make water cooler of different capacity complete all as specified and directed.
Supply only inner door gasket suitable for Usha Sriram/Sidwa/Voltas/Bluestar make water cooler of different capacity complete all as directed.
Supply only wiring kit suitable for water cooler of various capacity complete all as specified & directed.
Supply only condensor Fan blade set suitable for Water cooler of capacity 40/60/80/120/150 ltr complete all as directed.
Supply only PVC drain pipe 2m long of size 25 to 40mm dia complete with 04 Nos hose clip of suitable sizes complete all as directed .
Supply only drier filter pencil type suitable for water cooler of different capacity and any make complete all as specified and directed.
Supply only stainless steel water tray for safe drinking water suitable for Water cooler of capacity 40/60/80/120/150 ltr and any make complete all as directed.
S&F PVC float valve 15mm dia with epoxy coated aluminium rod and high density plastic ball min weight 142 gms with Nipple & long screws etc suitable for Water cooler fixed in repair complete all as directed.
S&F PVC connection 15 mm size 450 mm long with brass union nuts on both ends suitable for water cooler fixed in repair complete all as directed.
S&F PVC connection 15 mm size 600 mm long with brass union nuts on both ends suitable for water cooler fixed in repair complete all as directed.
S&F PVC connection 15 mm size 750 mm long with brass union nuts on both ends suitable for water cooler fixed in repair complete all as directed.
S&F PVC insulated and sheathed cable 3 core 2.5 sqmm stranded copper conductor fixed in repair complete all as specified and directed.
S&F Steel water tubing medium grade 15mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed.
S&F Steel water tubing medium grade 20mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed.
Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 15mm bore complete all as specified and directed
Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 20 mm bore complete all as specified and directed
M&L for Preparation of existing decorated surface of water cooler of any capacity,make & model and applying one coat of synthetic enameled paint (white) by spray machine including writing MES No/ SM No in capital letters of height not less than 20 mm on water cooler body in MES pattern and style complete all as specified and directed.
M&L for Rewinding of blower motor 1/32 HP, 1/35 HP, 1/12 HP AC 240 Volts single phase 50C/S with existing guage of copper winding wire including insulation varnishing and repair of connecting bushes, bearing , blower fan blade,shaft and connection wire and testing complete of water cooler of all as specified and directed.
Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 40/80 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 60/120 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
,Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 150 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Servicing of Refrigerator cap-165 upto 320 ltrs complete cleaning of storage, cooling/condenser coils etc complete all as directed by Engineer-in-Charge. Note :- (i)The rate quoted for servicing shall be inclusive of attending complaints and keeping the refrigerator in working condition during the entire contract period and further for defects liability period.(ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item
Checking of leakage of refrigerent system of Refrigerator of capacity 165/190/286 Ltrs to 300/310/320 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom legs suppots and testing and vaccumising the system and supplying and filling of oil in required quantity complete all as specified and directed. Note :- (i) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only starting relay box type suitable for refrigerator compressor of any make and capacity complete all as directed.
Supply only thermostat switch suitable for refrigerator/Deep Freezer of capacity 165 to 320 litrs / 200 to 340 litrs and any make complete all as directed by Engineer-in-charge.
Supply only inner door gasket suitable for refrigerators of make, VIDEOCON, GODREJ,KELVINATOR, SAMSUNG and any capacity (single/double door) etc complete all as specified and directed.
Supply only door handle suitable for refrigerators of make VIDEOCON,, GODREJ,KELVINATOR, SAMSUNG and any capacity (single/double door) etc complete all as specified and directed.
Supply only freezer with door assembly of make as approved by GE of size 165 upto 310 ltr capacity refrigerator(single/double door) complete all as directed.
Supply only bottom plate suppot Legs (size as per sample) suitable for refrigerators of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG and any capacity etc complete all as specified and directed.
Supply only door light switch (push button type) with lamp holder of make and size as directed complete all as directed.
Supply only electric bulb 15watt 250 volt AC or pin type make philips, Havells, Bajaj complete all as directed.
Supply only Glass cover for vegitable tray suitable for 165 upto 320 ltrs capacity of refrigerator(single/double door) complete all as directed.
Supply only fan motor for frost free Refrigerator of make VIDEOCON,, GODREJ, KELVINATOR, SAMSUNG, LG, WHIRLPOOL etc and any capacity complete all as directed.
Supply only frost heater suitable for frost free Reftigerator of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG,LG,,WHIRLPOOL etc and any capacity complete all as directed.
Supply only bio metal switch suitable for frost free Refrigerator of make VIDEOCON, GODREJ, KELVINATOR, SAMSUNG, LG, WHIRLPOOL etc and any capacity complete all as directed.
Supply only ice cube tray for Refrigerator 165 upto 320 ltrs capacity complete all as directed by Engineer-in-charge.
Supply only vegitable basket for refrigerator of different capacity as directed by Engineer-in-charge.Make & Size:- As per sample
Supply only timer suitable for frost free Refrigerators of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG,LG,,WHIRLPOOL etc and any capacity complete all as directed.
Supply only bottle rack of refrigerator door suitable for refrigerator 165 upto 320 ltr capacity and any make complete all as directed by Engineer-in-charge.
Dismantling and taking down unserviceable condensor coil and S&F condensor coil with accessories suitable for regrigerator of any make and capacity including charging of refrigerant gas R-134A and leakage testing and proper working effect duly complete all as specified and directed.
Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor unit of Make Kelvinator, Kirlosker, Whirlpool, Godrej, LG,Samsung etc capacity 1/8, 1/6 TR for Referigerator of any make, any size with copmplete testing by nitrogen pressure and charging of gas R-134A upto required pressure and proper working effect complete of size 165/190 to 310/320 litres capacity.
Servicing of Deep Freezer Cap-200/300/310/320/340 ltrs complete cleaning of storage, cooling/condenser coils etc complete all as directed by Engineer-in-Charge..Note :- (i)The rate quoted for servicing shall be inclusive of attending complaints and keeping the deep freezer in working condition during the entire contract period and further for defects liability period.(ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item
Checking of leakage of refrigerent system of Deep Freezer of capacity 200/300/310/320/340 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom leg suppots, testing and vaccumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :- Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item
Supply only Condensor fan Motor suitable for Deep freezer of any make and capacity complete all as specified and directed.
Supply only fan blade suitable for Deep freezer of any make and capacity complete all as specified and directed.
Disconnecting, dismantling and taking out defective /unserviceable sealed compressor unit and exchange with reconditioned sealed compressor unit suitable for deep freezer capacity 300/320 litre with complete testing by nitrogen pressure and charging of gas R-134A upto required pressure and proper working effect duly complete all as specified and directed.
Painting of existing Deep Freezer of any description and any position and capacity with applying one coat of synthetic enameled paint (white or approved by Engr-in-charge) by spray machine including preparation of existing decorated surface of deep freezer including writing MES No/ SM No in capital letters of height not less than 20 mm on deep freezer body in MES pattern and style complete all as specified and directed.
Supplying and Charging of refrigerant gas (Make Mafron R-134A) including leakage testing of complete plant/equipment with nitrozen gas and repairing leakage portion complete all as specified and directed.
Servicing of desert cooler in any position by, strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler complete all as directed by Engineer-in-Charge.Note :-The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.
Taking down desert cooler from the site by disconnecting the electric and water connections and scrapping old paint, cleaning and necessary preparation of surfaces and painting of existing colour with one coat of anti corrosive paint internally and two coats of synthetic enamel paint externally on the surfaces including bottom surface of desert cooler by spray painting and writing MES No of the desert cooler in the pattern and style as approved by the Engineer-in-Charge with different tint / colour complete all as specified and as directed.
Supply only electric blower fan motor 1/5 HP 1400 RPM single shaft for desert cooler complete all as directed.
Supply only water lifting submersible pump 1/7 HP 1400 rpm for desert cooler complete all as directed.
Supply only wood wool pad, set of three, weight not less than 200gms of required size as approved suitable for various desert coolers panels including GI chicken wire mesh complete as per site and as directed by Engineer-in-charge.Size of wood wool pad.
Supply only condensor 4 Mfd suitable for desert cooler complete all as directed.
Supply only fan blade set for desert cooler of size 18"/24" dia complete all as directed.
Supply only switch controlling knob of any size and make complete all as directed.
PVC insulated and sheathed cable 3 core 1.5 sqmm stranded copper conductor fixed in reapair complete all as directed..
S&F MS steel work for Desert cooler frame work,Cross arms,branching,supports,clamps,angles and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending cold or hot ,drilling holes for bolts, in any shape or size as indicated or directed in repair and with including two coat of synthtic enamel paint over a coat of primer. Complete all as directed.
Servicing of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) complete cleaning of cooling /condenser coils, changing of air dust filter pads complete all as specified and directed by Engineer-in-Charge.Note :- The rate quoted for servicing shall be inclusive of attending complaints and keeping the Cold Storage Plant of 5 ton Cap in working condition during the entire contract period and further for defects liability period.
Checking of leakage of refrigerant system of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item
S&F Copper tubing with insulation of sizes 5/8" for Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) fixed in repair complete all as approved by GE and directed by Engineer-in-charge.
S&F Copper tubing with insulation of sizes 3/8" for Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) fixed in repair complete all as approved by GE and directed by Engineer-in-charge.
M&L for Insulation foam suitable for fixing with copper tubing 1/2", 1/4", 3/8" and 5/8" fixed in repair complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Shri Ram, Copeland , Kirloskar, Techumesh, and Carrier of one unit of Cold Storage Plant 5 ton Cap (2.5 TR x 2 Units) complete including testing of nitrogen gas pressure and charging of gas R-22/R - 404A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Blower fan motor of one unit of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) including testing fixed in repair complte all as directed by Engineer-in-Charge.Make:- ISI Marked, as approved by Engineer-in-charge.
S&F Single pole, 25 Amp contactor suitable for Cold Storage Plant 5 ton (2.5TR x 2 Units) capacity fixed in repair complete all as directed by Engineer-in -charge.
S&F Condensor fan blade set suitable for cold storage plant 2.5 Ton capacity of ISI marked as approved by GE fixed in repair.
Supply & charging of refrigerant Gas REFR ON (R-404A) to make up the required pressure complete all as specified and directed by Engineer-in-Charge.
Air tight door rubber gasket suitable for Cold Storage Plant 5 ton Cap (2.5 TR x 2 Units) including testing fixed in repair complete all as directed by Engineer-in-Charge.
Cut off panel of cooling system with senser and all accessories suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity fixed in repair complete all as specified and directed by Engineer-in-Charge.
Evaporating unit with all accessories suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F Condenser coil suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity with all accessories and including charging of refrigerant gas R-22/R - 404A and leakage testing complete fixed in repair complete all as directed.
Dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 0.5 to 15 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. Note :-The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item
Supply only electro mechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round type for stabilizer as per requirement complete all as specified & directed.
Supply only relay 12/24 volts suitable for 1 -15 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make by GE.
Supply only DC electronic circuit relay of capacity 24/12 volts stabilizer for 1 to 15 KVA complete of approved make all as specified & directed.
Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp complete of approved make & of existing shape and size all as specified.
Supply only toggle switch 20/30 Amp two way of approved make all as specified and directed.
Supply only top plug 15 amp, 240 volts, ISI marked all as specified and directed.
Supply only top plug 5 amp, 240 volts, ISI marked all as specified and directed.
Supply only coopper wound voltage stabilizer single phase for automatic operation, naturally air cooled wall each mounting type and designed for input voltage between 17 volts to 250 volts with output stabilizes voltage 230 volts with accuracy of ± 2.5 % having digital display with time delay of 5 minits initally starts of capacity 5 KVA complete all as specified and directed. Note:- The unserviceable voltage stabilizer will be deposited in MES store yard.
S&F MCB SP 6 to 32 Amps, 240 volts 'B' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed.
S&F MCB SPN 40 to 63 Amps, 240 volts 'B' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed.
S&F MCB TPN 40 to 63 Amps, 415 volts 'B' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed.
S&F MCB TPN 100 Amps, 415 volts 'B' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed.
Dismantling and taking out/down the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts, painting the bottom with one coat of black synthetic enameled paint, replacement of the unserviceable and defective parts, brazing, reassembling and testing of the AC complete all as specified and directed by Engineer–in–charge. Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the AC in working condition during the entire contract period and further for defects liability period.
Checking of leakage of refrigerant system of window type AC of capacity 1.5/2.0 ton by putting the nitrogen pressure, identifying the leaks / defects, repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), is deemed to be included under the unit rate quoted by the contractor for this item
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge. Make:-"REFRON/FLORON/DAIKIN/GUJRAT FLORO" R-32/R410a/R-407c/R132a.
Supply only starting capacitor 80-100 mfd suitable for 1.5/2 TR capacity Window/split type AC complete all as directed.
Supply only starting capacitor of capacity 100-120 mfd complete all as directed.
Supply only running capacitor 36 mfd, complete all as directed.
Supply only running capacitor 45 mfd, complete all as directed.
Supply only electric condenser fan motor of split/window type AC capacity 1.5TR/2 TR AC , 220 Volts, Single phase complete all as specifie and directed.
Supply only front grill suitable for window type AC 1.5/2 TR cap of make Bluestar/Carrier/LG etc complete all as directed.
Supply only nylon/press jute filter suitable for 1.5 TR window AC complete all as specified and directed.
Supply only electric panel suitable for window type 1.5 /2TR AC units including making all electrical connections complete all as specified and directed by Engineer-in-Charge.
Supply only ventury made of thermo-coal insulation suitable for 1.5 TR/2TR capacity window type AC complete all as specified and directed by Engineer-in-Charge.
Supply only wiring Kit suitable for window type AC 1.5 to 2 TR cap complete all as specified & directed.
Supply only reverse cycle valve for heating system in window type /split type AC 1.5 / 2 Ton capacity with and including charging of refrigerant gas R-22 and leakage testing complete in position etc complete all as directed.
Supply only thermostat switch suitable for 1.5 TR/2 TR capacity of window type AC complete all as specified and directed by Engineer-in-Charge.
Supply only condensor fan blade set for window / Split type AC 1.5 / 2 Ton capacity of ISI marked as approved by GE.
Supply only relay box type suitable for window/ Split type AC 1.5TR/2TR capacity complete all as directed by Engineer-in charge.
S&F PVC insulated and sheathed cable 3 core 4.0 sqmm stranded copper conductor fixed in repair complete all as spcified and directed.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Kirloskar, Voltas, Carrier, Bluestar,LG,Samsung etc. for Window type AC 1.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Kirloskar, Voltas, Carrier, Bluestar,LG,Samsung etc. for Window type AC 2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
S&F Copper tubing with insulation of size 3/8" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repair complete all as directed.
S&F Copper tubing with insulation of size 5/8" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repaircomplete all as directed.
S&F Condenser coil suitable for window type /split type AC 1.5 / 2 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed
Taking out existing defective window/Split AC electric motor of 930 RPM, 1/8,1/5 HP 220 volts single phase strip opening for rewinding, removing for rewinding to & from to workshop as approved by Engineer-in-Charge, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) as approved by the engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop to the entire satisfaction of Engineer-in-charge and transportation & fixing the motor at site including necessary connection & testing at site complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking out the existing Air conditioner Split type of any description any capacity, any make and in any position, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engineer-in-Charge. NOTE:- (i) The servicing of one split AC (one indoor unit + one outdoor unit) will be measured as one job. (ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (iii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt. (iv) The rate quoted for servicing shall be inclusive of attending complaints and keeping the AC in working condition during the entire contract period and further forr defects liability period.
Checking of leakage of refrigerant system of split type AC of capacity 1.5/2.0 ton by putting the nitrogen pressure, identifying the leaks / defects, repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), is deemed to be included under the unit rate quoted by the contractor for this item
Supply only single pole, 25Amp contactor suitable for split AC 1.5/2 TR capacity complete all as directed by Engineer-in-charge.
Supply only mild steel angle iron stand factory made suitable for out door unit for 1.5/2 TR split AC complete all as directed by Engineer-in-charge.
Supply only remote for senser kit suitable for 1.5/2 TR capacity Split type AC of make Voltas, LG, Carrier AC's complete all as directed by Engineer-in-charge.Make :-As Per Sample
Supply only blower fan motor single phase 220/230 volts 1400 RPM suitable for 1.5TR/2TR Split type AC complete all as directed.
Supply only indoor blower motor single phase 220/230 volts 1400 RPM suitable for 1.5TR/2TR Split type AC complete all as directed.
Supply only PCB plate complete with connections suitable for Split type AC 1.5TR/2TR single phase capacity complete all as specified and directed by Engineer-in-Charge
M&L for Insulation for copper tube of size 3/8” or 5/8” fixed in repair all as directed by Engineer-in-Charge.
S&F PVC flexible Pipe 25mm/40mm/50mm dia size over insulated copper tube 3/8” or 5/8”,with necessary packing tape 50mm wide for protection fixed in repair complete all as specified and directed by Engineer-in-Charge.
Shifting and fixing split AC cap- 1.0/ 1.5 / 2.0 TR including cutting for hole on wall and making good of disturbed surface with matching existing finishes complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Kirloskar, Voltas, Carrier, LG,samsung,Videocon,Loyed etc. for Split type AC 1.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Kirloskar, Voltas, Carrier, LG,samsung,Videocon,Loyed etc. for Split type AC 2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Kirloskar, Voltas, Carrier, LG,samsung,Videocon,Loyed etc. for Split type AC 2.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22/R32 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
S&F PVC wire insulated, unsheathed copper conductor single core, 06 sqmm, 04 core 1100 Volts grade, multi stranded, FRLS flexible wire cable fixed in repair
M&L for Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 4 Sq mm size with multi stranded copper conductor drawing into 20 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed1X4 Sq mm cable(Green Colour) with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all as specified and directed. NOTE: (i) Two run of 4 sqmm single core PVC cable with one run of1X 4 sqmm (Green Colour) cable as earth conductor & condiut shall be measured as one unit/RM. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
M&L for Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sq mm size with multi stranded copper conductor drawing into 20 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sq mm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all as specified and directed. NOTE: (i) Two run of 6 sqmm single core PVC cable with one run of 6 sqmm (Green Colour wire) as earth conductor & condiut shall be measured as one unit/RM. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
S&F Switch piano, flush type, single pole one way, 15 Amp fixed in repair complete all as directed.
S&F Socket outlet, multipurpose, 2 in 1 5 pin, 15 Amp fixed in repair complete all as directed.
Supply only copper wound Voltagae stabilizer single phase for automatic operation , naturally air cooled suitable for refrigerator and designed for input voltage between 170 Volts to 250 Volts with output stabilizes voltage 230 Volts with accuracy of ± 2.5 % having digital display with time delay of 5 minits intially starts of capacity 3 KVA complete all as specified and directed. Make :- Microtech/Bluebird/ V-Guard Model No VGSD 50 supreme. Note:- The unserviceable voltage stabilizer will be deposited in MES store yard.
S&F Sheet metal enclosure, single pole and neutral with three pin and earth plug and socket with and including one single pole MCB 20 Amps, 240 volts,10 KA complete fixed in repair all as directed.
S&F Sheet metal enclosure, triple pole and neutral with three pin and earth plug and socket with and including one four pole MCB 63 Amps, 415 volts,10 KA complete fixed in repair all as directed.
Supply only REO Modular AC MCB box protected socket PVC pastic base 3-Model including 25 amps plug top and MCB 25 amp fixed in repair complete all as specified and directed.
Taking down unserviceable storage type electric water heater (Geysers) after isolating electric supply of capacity 25/35/50 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as specified and as directed.
Taking down unsv storage type electric water heater (Geysers) any make after isolating electric supply capacity 100/150 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as specified and as directed.
S&F Non return valves cast copper alloy 15 mm dia ISI mark complete including taking down old existing NRVcomplete all as specified and as directed..
Taking down old/unserviceable assembly of water heater of capacity 25/35 ltr & S&F new stainless steel chromium plated assembly ISI marked as per sample suitable for water heater of capacity 25/35 ltrs complete all as specified and as directed.
Taking down old/unserviceable assembly of water heater of capacity 50 ltr & S&F new stainless steel chromium plated assembly as per sample suitable for water heater of capacity 50 ltrs complete all as specified and as directed.
S&F Heating element 2 KW 230 volt, ISI marked, round /triangular type or as per sample for storage type electric water heater including taking down existing unserviceable element complete all as specified and as directed.
S&F Heating element 2.0 KW 230 volt, ISI marked square/rectangular type (For existing recold Geyser) or as per sample for storage type electric water heater including taking down existing element complete all as directed.
S&F Heating element 3 KW, 230 volts ISI markded Round shape base (For Geyser cap 100/150 ltrs) with provn of Thermostate Racold Model PL-150, ISI Marked including taking down existing element complete all as specified and as directed.
S&F Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked as per sample suitable for round/Tringlular type element including taking down existing complete all as specified and as directed.
S&F Thermostate switch 220- 240 volt 16 Amp 0-75° / 80° C ISI marked as per sample suitable for square/rectangular type (For Recold Geyser) of element including taking down existing complete all as specified and as directed.
S&F Indicating lamp 230 volt AC for geyser fixed in repair of Green & Red colourcomplete all as specified and as directed..
S&F Heavy duty PVC connection with 15mm dia 450mm long CP with brass nuts and leads PVC washer 02 Nos on each ends for geyser connection fixed in repair complete all as specified and as directed
S&F Heavy duty PVC connection with 15mm dia 600mm long CP with brass nuts and leads PVC washer 02 Nos on each ends for geyser connection fixed in repair complete all as specified and as directed.
S&F Metallic fastener screw 75mm long 6mm dia with bolt for hanging Geyser, complete all as directed.
S&F Multifunction safety valve cast copper alloy 15 mm dia ISI marked complete including taking down existing valve complete all as specified and as directed.
S&F 3 Pin plug top 15 amps complete ncluding taking down existing top complete all as specified and as directed.
Supply and fix in repair Rubber gasket for fall plate for 25/50 Ltr capacity geyser complete all as specified and directed
Supply and fix in repair Pressure release valve 15mm dia for 50 Ltr capacity geyser complete all as specified and directed.
Dismantling and taking out the non-functional water purifier of any description, any make and in any position of capacity upto 25 to 30 ltrs/hrs, including disconnection of water line connections, cleaning and general servicing of the water purifier , checking all serviceable parts, reassembling all parts of water purifier, restoring water supply connections and testing of the water purifier complete all as specified and directed by Engineer–in–charge. Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the water purifier in working condition during the entire contract period and further for defects liability period.
Supply only water purifier sediment filter set suitable for existing water purifier complete all as specified and directed.
Supply only maimbren set suitable for existing water purifier complete all as specified and directed.
Supply only Solonoid Valve suitable for existing water purifier complete all as specified and directed.
Power supply, 240 volts, 50 Hz suitable for water purifier complete all as specified and directed.
Supply only carbon filter suitable for water purifier complete all as specified and directed.
Supply only water purifier booster water pump 24/48 watts suitable for water purifier complete all as specified and directed.
Supply only auto cut float valve suitable for existing water purifier complete all as specified and directed.
Supply only tube jointer,bulkhead,elbow etc suitable for existing water purifier complete all as specified and directed.
Supply only RO water flexible pipe,size 1/4-1 inch suitable for water purifier complete all as specified and directed.
S&F Switch piano, flush type, single pole one way 5 Amp fixed in repair complete all as specified and directed
S&F Socket out let, multipurpose, 2 in 1 5 pin, 5 Amp fixed in repair complete all as specified and directed
Dismantling and taking out unserviceable water purifier and S&F RO water purifier,wall mounted,capacity 50 LPH including all fittings complete all as spcified and directed. Make:-(i) AQUAGUARD Model-PRIMA 50 B RO + UV (Capacity 50 LPH) (ii) KENT, Model No-Elite Plus (RO+ UV+UF+TDS control),(iii) AQUAFRESH, Model No-AAOO.
Dismantling and taking out unserviceable water purifier and S&F RO water purifier,wall mounted,storage cap 8 L,auto shut-off inlcuding all fittings complete all as spcified and directed. Make:-AQUAGUARD, Model -Reviva RO + UV (Styorage Capacity 8 Ltrs), KENT, Model No-11133 Supreme, PUREIT, Model No-WUCU100.
Dismantling and taking out unserviceable split AC indoor unit and S&F split AC indoor unit suitable for existing Split type AC 1.5/2 TR capacity with copper coil complete including testing of nitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper working effect to the satisfaction. complete all as specifed and directed. Note:- The unserviceable split AC Indoor unit will be deposited in MES store yard.
Dismantling and taking out unserviceable split AC outdoor unit and S&F split AC outdoor unit Suitable for existing Split type AC 1.5/2 TR capacity complete including testing ofnitrogen gas pressure and charging of gas R-22/R-32 upto required pressure and proper wdorking effect to the satisfaction complete all as specifed and directed. Note:- The unserviceable split AC outdoor unit will be deposited in MES store yard.
Supply only copper wound Voltage Stabilizer single phase for automatic operation, naturally air cooled Suitable for Water Cooler and designed for input voltage between 170 Volts to 250 Volts with output stabilizers voltage 230 Volts with accuracy of + 2.5% having digital display with time delay of 5 minits initially starts of capacity 4 KVA complete all as specified and directed. Make:- V-Gurad, Bluebird, Microtek. Note:- The unserviceable Voltage Stabilizer will be deposited in MES store yard.
Repair and replacement of Desert Coolers electric driven (Single phase) having nominal air flow capacity of 4000 cum per hour,tank capacity minimum 50 ltrs with honeycomb pads and all standard accessories and Angle Iron stand of required height including one No 5 Amp 3 pin Plug top complete all as pecified and directed. Note:- The unserviceable Desert Cooler will be deposited in MES store yard. Make:-Samphony, Khaitan, Universal.
S&F Water heater (Geyser) storage type, electric,capacity 25 litres five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMGTWH025or equivalent in Bajaj/Usha/Recold
Heating element 2.0 KW 230 volt, ISI marked square/rectangular type (For existing Bajaj calenta Geyser) or as per sample for storage type electric water heater including taking down existing element complete all as directed.
S&F Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked suitable for bajaj calenta geyser including taking down existing complete all as specified and as directed.
S&F Water heater temprature sensor range -40 to 150 degree celsius 230 volt AC,50 Hz suitable for bajaj geyser fixed in repair complete all as specified and as directed..
Supply and charging of FLUORO R32 refrigerant Gas to make up the required pressure complete all as specified and directed. Note:- Charging cost including in this item.
Supply and Charging refrigerant gas refill 0.2 kg (Make HFCS R-600A) including leakage testing of complete plant/equipment with nitrozen gas and repairing leakage portion complete all as specified and directed. Note:- Charging cost including in this item.
S&F Metal clad industrial plug top and porcelain socket 3 pin 20 Amps with earth pin 230 to 250 Volts including taking down existing complete all as specified and directed.
Tarachand gurudutt
M/s Anamika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .