Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | Admitted-Finance |
| 2 | Admitted-Finance 4314 FIRST FLOOR KIKAR BAZAR BATHINDA 151001 PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
18 Mar 2021, 11:30 amClosed
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Repair/Renovation of Old damaged header and other allied works at Rana Pratap Bagh SPS.
2021_DJB_201438_9
NIT NO. 23 (2020-2021)
Open Tender
Miscellaneous Services
Item Wise
60 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
Exempted
31 Mar 2021
12 Mar 2021
18 Mar 2021
12 Mar 2021
18 Mar 2021
12 Mar 2021
Dismantling of existing damaged 300/200 mm dia. header line and allied accessories from the pump set with the help of heavy manual labour and electric welding set and gas cutter using proper logistics arrangements i.e. special tripod for holding the dismantled pipe and other accessories.
Supply of 300 mm dia. M.S. pipe having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved
Dismantling of existing damaged Suction line of 150mm dia. line from deep Sump well with the help of heavy manual labour and electric welding set and gas cutter using proper logistics arrangements i.e. special tripod for holding the dismantled pipe and other accessories.
Removing of MS Base frame from RCC by cutting foundation bolts bolts by using gas cutter/Welding set, manual labour and lifting/shifting the same to JE Store etc.
Breaking of RCC foundation by pneumatic power hammer and electric compression machine etc. Removing the broken material from pump house and disposing the same at suitable place as per instruction of Engineer in Charge.
Making /Casting the new foundation with the each RCC mixture upto 150mm height suitable for 25HP Pump Set size of the foundation 1650mmx600mm approx..i/c providing the foundation bolts(6 Nos.) each & fixing the same in the foundation before casting etc. as required.
Supply of 125 mm dia. M.S. pipe having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved
Supply of 150 mm dia. M.S. pipe having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make - TATA/ Jindal/ ISI/ Any other DJB Approved
Providing the Sluice valve P.N 1.0 Size 125mm. Make: Kirloskar/IVC
Providing the NRV P.N 1.0 Size 150mm. Make: Kirloskar/IVC
Supply of 12mm thick M.S flange for 150 mm dia. M.S pipe.
Supply of 20mm thick M.S flange for 300 mm dia. M.S pipe.
Fabrication & supply of MS blind flange 300 mm dia thickness 20mm as per site requirement.
Supply of neoprene rubber packing sheet as per site requirement.
Supply of M.S Nut bolts washer as per site requirement.
Providing of M.S. Bend of 150 mm dia. having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make- TATA/ Jindal/ISI/ Any other DJB Approved
Providing of M.S. Bend of 125 mm dia. having thickness 8 mm duly painted with black bituminous anticorrosive paint. Make- TATA/ Jindal/ISI/ Any other DJB Approved
Hiring of D.G set of suitable capacity with fuel and operator.
Safety arrangement Air face mask, hand blowers, helmets, Gum Boots, safety belts, portable ladder, first aid box, caution board, caution tape, barrier cone, torch, fire extinguisher etc. arranged by the firm at site of work for safe working.
Lighting arrangement at site of work i/c consumables as per site requirement. Hiring charges of electrical accessories, T&P, flood light, Halogen light, bulbs etc. with all cabling and panel board switches.
Fixing of existing MS Base frame on the new foundation, valves, gap pieces by electric welding set, manual labour, alignment the pump/motor also making connection of the pump set etc.
Replacement of header by welding the flanges of 12mm thickness of the M.S pipe of 300mm dia. by cutting , welding, grinding etc. and fixing the same in proper alignment alongwith the existing holding arrangement with the help of heavy manual labor, nut/ bolts etc. complete in all respect as per site requirement.
Replacement of Suction line/Delivery line of 150mm/125mm by welding the flanges of 12mm thickness by cutting , welding, grinding etc. and fixing the same in proper alignment alongwith the existing holding arrangement with the help of heavy manual labor, nut/ bolts etc. complete in all respect as per site requirement.
Minor Civil work required for restoration of damaged support during dismantling of damaged header with the help of mason and labor etc.
Transportation of man and material at site of work. The work also includes Testing and commissioning of header on NO LOAD/FULL LOAD with full pressure as per satisfaction of engineer in-charge.
Painting the header and allied accessories with minimum one quote of primer and 02 minimum quotes of enamel paint.
SANJAY SALES CORPORATION
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .