Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC 80 STATION PALLY DANKUNI HOOGHLY 712331 | 712331 | ₹3.3 L | L1 | Accepted-AOC Accepted as L1 Bidder |
| 2 | L2₹3.3 L+₹2,573.03 (0.79%)Rejected-AOC | ₹3.3 L+₹2,573.03 (0.79%) | L2 | Rejected-AOC Rejected as L2 Bidder |
| 3 | L3₹3.3 L+₹2,672 (0.82%)Rejected-Finance BARASAT HOUSING ESTATE PH II P O NOAPARA KOLKATA 700 125 | 24 PARAGANAS NORTH | WEST BENGAL | 700125 | ₹3.3 L+₹2,672 (0.82%) | L3 | Rejected-Finance Rejected as L3 Bidder |
| 4 | L4₹3.3 L+₹5,904.78 (1.80%)Rejected-Finance 1 1E KHODAGONGE ROAD KOLKATA 700 010 | KOLKATA | KOLKATA | WEST BENGAL | 700010 | ₹3.3 L+₹5,904.78 (1.80%) | L4 | Rejected-Finance Rejected as L4 Bidder |
| 5 | L5₹3.4 L+₹9,170.55 (2.80%)Rejected-Finance | ₹3.4 L+₹9,170.55 (2.80%) | L5 | Rejected-Finance Rejected as L5 Bidder |
Tender Value
₹3.3 L
EMD Value
₹6,598
Closing Date
31 Jul 2026, 2:00 pmClosed
Executive Engineer
Electrical Division - I, EM Sector, KMDA, Unnayan Bhavan, L-Block, Ground floor, Salt Lake City, Kolkata-700091
Installation of additional service light with allied electrical works at AIFF National Centre of Excellence, New Town, Kolkata.
2026_KMDA_1032955_1
13 / EE / ED-I / EM / KMDA / T-2 of 2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
7 days
New Town, Kolkata
Please refer Tender documents
8 documents required · 8 mandatory
₹0
₹6,598
1 Sept 2026
24 Jul 2026
3 Aug 2026
24 Jul 2026
31 Jul 2026
24 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Supplying of Swaged Steel Tubular pole (IS 2713, Pt. II 1980) for following designation and of following dimensions: | - | - | - | - |
| 1.1 | a) 410-SP-1; 7.0 mtrs: 62.00 Kg | 5 | Nos. | 5,383 | ₹26,915 |
| 0.0 | Supplying and Fixing waterproof looping cable box/ junction box having one 250 V, 6 A SP MCB and housing the same in pole incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting as per direction of EIC. | - | - | - | - |
| 2.1 | a) 250 x 200 x 105 mm | 9 | Nos. | 1,812 | ₹16,308 |
| 0.0 | Supplyingn and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. | - | - | - | - |
| 3.1 | a) 6-32 A SP MCB | 5 | Nos. | 190 | ₹950 |
| 0.0 | Earthing with one 15.88mm dia GI rod with double GI nuts and washers and 4SWG GI wire to an average depth of 3 mtr. | - | - | - | - |
| 4.1 | a) With 1.8mtr long earth spike. | 10 | Nos. | 300 | ₹3,000 |
| 0.0 | Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-45, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80 , under voltage and over voltage protection, EMI EMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 mm² FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). | - | - | - | - |
| 5.1 | a) 250 Watt | 15 | Nos. | 4,613 | ₹69,195 |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
TENDER_DOCUMENTS.pdf
Tender Documents • 2.44 MB
BOQ_2536875.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .