Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.9 LAccepted-AOC BANKIM CHANDRA ROAD HAKIMPARA SILIGURI DIST DARJEELING PIN 734001 W B | JALPAIGURI | WEST BENGAL | 734001 | ₹21.9 L Quoted ₹22.8 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹23.5 L+₹66,033.57 (2.89%)Rejected-Finance VILL POST BARANACHINA PS DINHATA DIST COOCH BEHAR 736135 | COOCHBEHAR | WEST BENGAL | 736135 | ₹23.5 L+₹66,033.57 (2.89%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹24.3 L+₹1.5 L (6.56%)Rejected-Finance 777 AMAR NAGAR VILLAGE TOWN CITY RAE BARELI RAEBARELI UTTAR PRADESH 229001 INDIA | RAE BARELI | UTTAR PRADESH | 229001 | ₹24.3 L+₹1.5 L (6.56%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹24.6 L+₹1.8 L (7.68%)Rejected-Finance GAIRKATA ROAD WARD NO 03 PO PS DHUPGURI DIST JALPAIGURI W B PIN 735210 | JALPAIGURI | WEST BENGAL | 735210 | ₹24.6 L+₹1.8 L (7.68%) | L-4 | Rejected-Finance Being L-4 |
| 5 | L-5₹25.0 L+₹2.1 L (9.32%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | ₹25.0 L+₹2.1 L (9.32%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
2 Sept 2023, 6:00 pmClosed
GE NORTH BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR TO FALSE CEILING, WALL PANELING AND CERTAIN MISCELLANEOUS WORK IN OTM ACCOMMODATION AT CENTRAL ZONE UNDER GE (NORTH) BINNAGURI
2023_MES_611523_1
NIT No. 8701 / 21 / 2023-24 / 15 / E8
Open Tender
Civil Works
Item Rate
270 days
BINNAGURI CANTONMENT
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE NORTH BINNAGURI
₹66,000
Yes
20 Oct 2023
1 Aug 2023
4 Sept 2023
1 Aug 2023
2 Sept 2023
16 Aug 2023
Amount
S&F in repair of 4mm thick designer board false ceiling with powder coated GI snap grid frame work of grid size 600 x 600 mm complete all as specified and as directed including all necessary drilling and necessary arrangement to fix including the following items as under:- (a) 27x27x0.55 mm thick GI angle powder coated duly plugged @ 600mm centre to centre alongwith perimeter of wall. (b) 25x25x0.55 mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders (n.exe 1.2 mtr length) with adjustable clamps and dash true fastners plugging in RCC slab/wooden truss/Angle Iron runner of slopped roof placed @ 600mm centre to centre from perimeter of wall. (c) Supply & Fixing of 4mm thick non asbestos cement designer board of approved texture and finished complete. Note: The complete ceiling work shall be done as per manufactures instruction and as directed.
S&F in repair of POP seamless false ceiling with powder coated GI snap grid frame work complete all as specified and as directed including all necessary drilling and necessary arrangement to fix items as under :- (a) Perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleevs and screws450 mm c/c intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit including ceiling section of 0.55 mm thick having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to intermediate channel 1.6mm dia GI wire suspenders (n.exe 1.2 mtr length) with adjustable clamps and dash true fastners plugging in RCC slab/wooden truss/Angle Iron runnder of slopped roof placed @ 600mm centre to centre from perimeter of wall. (b) Fixing of calcium silicate ceiling made out of 1800mm x 1200mm x 12mm, 1200mm x 1200mm x 12mm thick fixed to ceiling section with 25mm long self drilling and tapping screws complete. Note: The complete ceiling work shall be done as per manufactures instruction and as directed.
S&F in repair solid PVC wall lining consisting of 5mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site complete all as specified and as directed.
M&L 5mm thick PVC sheet fillet of width 35mm as per specifications and drawing complete all as specified and as directed.
M & L for 18/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cupboard door/shelves/wall paneling including 6 mm thick wooden lipping and dismantling of old boarding complete all as specified and as directed. Note : The cost is including polishing to wood surfaces.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (unreinforced) including existing treatment of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Material & labour for 75mm thick PCC (1:3:6) Type C-2 (40 mm graded stone aggregate) as in plinth protection including finishing the concrete surface even and smooth w/o using extra cement complete all as specified. Note: The unit rate quoted shall be deemed to include for providing the concrete in alternate bays n exc 3 mtr long with 12 mm wide and 50 mm deep joint between the bays which shall be filled with mastic filling with hot bitumen 85/25 and 1:2 mix by volume.
M&L for non skid ceramic tiles of size 400x400x7mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match etc including 15mm thick screed bed bedding layer in CM 1:6 for laying floor finishes complete all as specified and as directed.
M & L for non skid coloured ceramic floor tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm, in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed.
M&L for 300 x 450mm size glazed ceramic coloured tiles in vertical surface not less than 7 to 8 mm thick set and jointed in neat cement slurry laid over 10mm thick rendering in cement mortar (1:4) and pointed in white or coloured cement to match etc complete all as specified and as directed.
M&L for Vitrified Ceramic tiles of light shade 8mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor and including 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and as directed.
M&L for Vitrified Ceramic tiles of light shade 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 Sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor and including 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and as directed.
M&L for 25 mm thick prepolished chequered tiles of size 300 x 300 mm set and jointed in neat cement slurry including 15mm thick screed bed in CM 1:6 and pointed in white or coloured cement mixed with mixture of pigments to match with the colour of tiles including demolition of existing floor tiles complete all as specified and as directed.
M&L for 80 mm thick precast concrete polished coloured interlocking paver block with grery cement and pigment, any shape and size confirming to IS 15658-2006, M-40 Grade including dismantling of old paver blocks complete all as specified and as directed.
M&L for sand cushioning under interlocking paver blocks complete all as specified and as directed. Note: Sand cushioning will be measured and paid separately under relevant item of this schedule.
M&L for granite work 18-20 mm thick table rubbed and polished as in top of kitchen slab over 15 mm thick cement screed bed cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L Rounding to edge of stone, Granite slab, kota stone slab one edge, such as in steps, cooking platform and other similar work complete all as specified and as directed.
S&F in repair 2 nd class hardwood boarding in floors planed one side with butt joints and fixed with nails complete all as specified and as directed.
S&F in repair powder coated aluminium window sliding type three track (one gauge and two glazed shutter) aluminium sections weighing not less than 0.55 Kg per mtr for shutter and aluminium sections weighing not less than 1.67 Kg per mtr for frame including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement etc complete including 4 mm thick tinted glass and stainless steel mosquito proof gauge and taking down old one complete all as specified and as directed.
S&F aluminum anodized louvered ventilators with glass louvers, without sash bars, of aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and with suitable locking arrangements including taking down old one complete all as specified and directed.
S&F in repair powder coated glazed aluminium section for partition with one or mor rebates complete all as specified and as directed.
S&F in repair Solid PVC Wall Lining consisting of 5mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site on alluminium door as per specifications and drawing complete all as specified and as directed.
S&F in repair 5.5mm thick Sheet glass, ordinary quality, fixed with existing snap beading, rubber gasket etc. area of each pane exc. 0.50 sqm complete all as specified and as directed.
Supply & Fixing in repair powder coated anodised aluminium frame (sections weighting not less than 1.40 kg/mtr) made of Square/tubular Aluminium section for door with one or more rebates jointing cleat for fixing etc and provision of aluminium door shutter (Single/Double shutter) including necessary jointing cleats glazing clips, rubber gasket aluminium anodised snap beading, screws, hold fast, Aluminium hinges 3Nos 100mm long for each shutter, floor stopper, locking arrangements handle 4 mm thick tinted glass fixed in panels complete all as specified and as directed.
S&F factory made pressed steel windows of standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-07, Sheet 1/3 to 3/3 with double shutter i.e glazed & wire gauged shutter including all fittings and fixture like MS hold fast, box hinges, handles, MS tower bolts, stoppers, MS guard bar/grill etc complete including one shop coat of anti corrosive zinc chrome primer complete all as specified and as directed. Notes:- (a) Rate quoted shall be deemed to be including of all fittings fixtures . (b) Glass, wire mesh MS guard bar/grill and painting shall be measured and paid separately under relevant items of this schedule. (c) PCC (1:3:6) type C1 to be filled in chowkats frame and paid under relevant item of this schedule.
All as per Item No 26 here-in-before but with single shutter of glazed/wire gauged shutter including one shop coat anti-corrosive zinc chrome primer complete all as specified and as directed.
S&F Mild steel framed work such as grills, gratings, guard bar etc with ends of bars shouldered or riveted or for forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290. Gde -E- 165 complete all as specified and as directed.
S&F of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staple complete all as specified and as directed.
Dismantling plain / corrugated steel / AC Sheets any gauge or any thickness fixed in any position complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Rolled Mild steel work as in roof trusses purlin, brackets, cleats posts etc complete using Fe 410-w (gde E-250) Quality A including welding complete all as specified and as directed as in additional stiffners and wind ties.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 0.5mm thick of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F prepainted Galvalume Aluminium Zinc Coating GI based Plain Steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in eves board, valley gutters, curves, ridges, corner boards etc fixed with self tapping screws complete all as specified and as directed.
M&L for two coats of synthetic enamel painting to steel surfaces any description over 10 Cm in width or girth not otherwise described including preparation of surfaces complete all as specified and as directed.
Taking up or down CPVC or GI tubing 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and as directed.
Taking up or down or 20mm steel tubing or CPVC pipe and connections including cleaning for refixing or removal to store complete all as specified and as directed.
Refixing old CPVC or GI tubing 15mm bore pipe and connection in new or old position (wall, ceiling, floors etc complete all as specified and as directed. Note: Old serviceable tubing obtained from taking down shall be reused.
Refixing old CPVC or GI tubing 20mm bore pipe and connection in new or old position (wall, ceiling, floors etc complete all as specified and as directed. Note: Old serviceable tubing obtained from taking down shall be reused.
S&F 15mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 20mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Demolition of brick work built in cement mortar and removing from site complete all as specified and as directed.
M&L brickwork with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and as directed.
M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and as directed.
Taking down cement plaster on wall of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for Rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and fair without using extra cement complete all as specified and as directed.
M&L for 5mm thick plaster rendering on fair faces of concrete surfaces of ceiling in CM(1:3) finished even and fair (without using extra cement) complete all as specified and as directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @2% by the weight of cement or as per manufacturer's instructions finishing the surface even and fair complete all as specified and as directed. Note: Integral liquid water proofing compound shall be measured and paid separately.
Supply only Liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for applying two coats of exterior emulsion paint (weather coat) over a coat of exterior primer damp coat on a new plastered surfaces of facia, roof projection, chajja etc including necessary preparation of surfaces complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of walls and applying two coats of oil bound distemper over a coat of primer and a coat of wall care putty complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of ceilings and applying three coats of white wash on ceiling complete all as specified and as directed.
S&F in repairs for PVC cornices as per design complete all as specified and as directed.
M&L for preparing old oil bound distemper surfaces of walls including cornices, pilasters and other wall features etyc by washing rubbing down and stopping and applying and finishing the walls with textured exterior paint of required shed two coats over and including priming coat of exterior primer complete all as specified and as directed.
M&L for preparing old oil bound distemper surfaces of walls including cornices, pilasters and other wall features etyc by washing rubbing down and stopping and applying and finishing the walls with premium acrylic smooth exterior paint with silicone additives of required shade (luster paint) over and including priming coat of exterior primer complete all as specified and as directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and separating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and as directed.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly for one light point controlled by one, one way switch complete all as specified and as directed.
All as per item No 58 above here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and as directed.
All as per item No 58 above here in before but for one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and as directed.
All as per item No 58 above here in before but for one 3/5 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and as directed.
All as per item No 58 above here in before but for one bell point controlled by one, bell switch 5 Amps complete all as specified and as directed.
All as per item No 58 above here in before but for light point controlled by two way switch Amps complete all as specified and as directed.
All as per item No 58 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
S&F switch piano single pole flush type 5 amps, 230 volts one way complete all as specified and as directed.
S&F switch piano single pole flush type 5 amps, 230 volts two way complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and as directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S&F in repair Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F in repair Modular switch, single pole, Two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F in repair Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F of stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans, ISI marked complete all as specified and as directed.
S&F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F Call bell Ding dong, 230 Volt single phase all as specified and as directed.
S&F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed.
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unsv fitting complete all as specified and as directed.
S&F IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed.
S & F Recess round shape LED ceiling light 12 Watt fitting (6'' outer dia) for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old light fitting complete all as specified and as directed.
S & F Post top lanterns 15 watt LED light fitting ,new generation, energy saving, environmental friendly, long life with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories internally prewired including connecting up with three core twisted flexible copper conductor cable up to ceiling rose and necessary mounting arrangements and taking down old light fitting complete all as specified and as directed.
S & F Recess mounting flat panel 34 Watt LED fitting (2'X2') for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection and taking down old light fitting complete all as specified and as directed.
S&F of Decorative wall light fixture made up of polycarbonate suitable for 15 Watt LED retrofit of type B-22 base, IP66 grade, with and including 15 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25 mm dia PVC rigid non- metallic concealed conduit with and including taking down unsv sub main, complete all as specified and as directed. Note: Two runs of sub main wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
S&F in replacement of sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S & F sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete including removal of old unsv sheet metal enclosure complete all as specified and as directed.
S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface including removal of old unsv sheet metal enclosure complete all as specified and as directed.
S&F in replacement of MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F in replacement of MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed.
S&F in replacement of MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed.
S&F Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, including necessary connection complete all as specified including taking down old one complete all as specified and as directed.
PULAK SAHA
SINGH & CO
BIG BEN ENTERPRISES
M/S SINHA ENTERPRISE
M/S DUTTA ENTERPRISE
SHRI MRITYUNJOY KAR
MESSRS SEN BROTHERS
P CHAKRABORTY CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .