Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹3.5 L+₹25,355 (7.79%)Rejected-Finance | L2 | Rejected-Finance SINCE L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical BIDDER REJECTED |
Tender Value
Refer Docs
EMD Value
₹4,500
Closing Date
24 Dec 2024, 6:55 pmClosed
SO(ENM)
GM UNIT KUJU
Electrical rewiring of Weighbridge 01 which has to be shifted near checkpost and rewiring of weighbridge 02 installed at Karma Project under Kuju Area.
2024_CCL_323354_1
GM (K)/EnM/eTender/24-25/248
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹4,500
24 Feb 2025
13 Dec 2024
25 Dec 2024
13 Dec 2024
24 Dec 2024
14 Dec 2024
13 Dec 2024 - 20 Dec 2024
Amount
Wiring for light point/ fan point /exhaust fan point / call Bell point int with 1.5sqmFRES PVC insulator copper conductor single core cable in surface/resessed medium class PVC coduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 1 FRLS PVC Insulated copper conductor single core cable ets as reqired, Group B
Rewiring for light point fan point/exhaust fan point/call bell pont with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and 1.5 sq mm FRLS PVC 2 insulated copper condustar single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required Group B
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class FVC conduit as required. (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)
Wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 A socket outlet and 2 way 5/6 A switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet and 15/16 A switch
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing PVC batten/angle holder including no connection etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular: plate etc. as required.
Supplying, installing, testing and commissioning of following capacity TPN tap ofi box made of 1.6mm thick sheet steel enclosure duly painted with pov der coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 100 AΜΡ. ΤΡΝ
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with pov/der coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required. 63A ΤΡΝ
Supplying and lixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A for lighting control
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm)
Supplying and fixing DP sheet steel enclosure on surface/n recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing of 18W LED tubelight
Providing and fixing of 18W LED bulb
Supply, testing and commissioning of 3 phase, 4 pole surge protection device
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Total impact of GST for the purpose of CTC
Electro Enterprises (BID ID -1109681)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .