SITC of Chilled water system for EV Dyno lab equipments and Air condtioning system for control room/panel room at AEC Chakan.
2026_ARAI_925942_1
AEC-CHAKAN-52-PR-60005651
Open Tender
Miscellaneous Works
Buy
180 days
ARAI AEC center, Plot No A 22/2, Maharashtra Indust
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹5.9 L
Yes
ARAI AEC center,Plot No A 22/2, Maharashtra Indust
11 Sept 2026
11 Sept 2026
5 Oct 2026
11 Sept 2026
1 Oct 2026
12 Sept 2026
12 Sept 2026 - 22 Sept 2026
22 Sept 2026
Supply, Installation, Testing & Commissioning of Air Cooled Screw Chiller with VFD complete with Twin Screw Semi-hermetic type Compressor, Shell & Tube Condenser & Chiller Expansion Valves, Soft Starter, First Charge of Green Gases & Oil etc. The plant should be suitable for the following parameter Capacity. The Chillers should be installed on a baseframe along with Antivibration Spring mounted pads. The chillers shall be tested as per AHRI Std for four points. The chiller shall be AHRI & Eurovent Certified. Nominal Capacity 330 TR at 35 Deg C Water Inlet Temperature = 23 Deg.C Chilled Water Outlet Temperature = 18 Deg.C
SITC of Chilled water pump. Supply, installation, testing and commissioning of Non-self priming, end suction single stage centrifugal pump, directly coupled with IEC flanged 3 ph motor, pull out type pumps with TEFC motor with protection IP 65 and complete with all components and accessories like pump body CI, bronze/SS impeller, bronze wear ring, SS shaft, ball bearings, mech shaft seals, coupling, coupling guard. Proper MS base frame to be provided for mounting pump. Base frame shall be painted with primer and oil enamel paint. Anti-vibration isolation pads shall be provided. Entire pump body to be enclosed by nitrile rubber thermal insulation of minimum 25 mm thickness and further covered with 26 Gauge aluminium cladding. Protection hood to be provided for pump motor. Flow : Minimum 3000 LPM Head- 4.5BBar at Condensor ( Contractor to design the over all head for entire system to consider the all fittings) Make- Armstrong/Grundfos/Willo
Supply, Installation, Testing & Comssioing of Closed type, Buffer Vesel with man hole & other accesories of Min 12000 Ltr capacity will be of M.S. construction of 6mm thick .The tank shall be fabricated as per IS 2825-1969 for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. For chilled water application, it will be insulated with 25 MM thick TF quality EPS covered with 26 Gauge Aluminum Cladding.
Supply, Installation, testing and commissioning of GI 'C' class chilled water piping complete with all required bends, elbow, tees, reducer, flanges, rubber gaskets, MS Supporting & Hardware includes etc. These pipe shall be insulated with 19mm thick nitride rubber and aluminium cladding of 26swg. Make- Zenith/Tata/Zindal
Supply , Installation,Testing & commissioning EPDM lined butterfly valves for Buffer Vesel, Seam seal body CI Coated with nylon PN16, Seat of nitrile with flow control lever
Supply, installation, testing and commissioning of electrical control panel. Electrical panel shall be provided for operation of chilled water pump mentioned in Sr. no. 2 Control panel shall be conform to IEC 60439, IP 65 compliant. Panel shall be fabricated from MS sheet of minimum 1.6 mm thickness, powder coated with 7 tank dip process. Panel shall be floor/wall mounted as per site conditions. Panel GA drawing to be approved by ARAI In charge before fabrication. all necessary star delta starter/ MCB/switchgear/hardware shall be provided for proper operation of pump, as per OEM recommendation. Panel shall have provisions to provide all safety interlocks like dry run, over load, under current, single phase protection, etc. for safe and proper working of pump. All necessary hardware to be provided by bidder. ON and OFF push buttons to be provided on panel for pump operation. Panel shall have ON/OFF/TRIP LED indication lamps to indicate pump status. Panel shall have R/Y/B phase indication lamps on panel. Panel shall have main isolation switch/MCB. Panel shall have top/bottom entry for cabling, as per site conditions. Proper glands to be used. Panel shall have appropriate ventilation arrangement. VFD for pumps is to be considered. Panel AC is to considered with apprpiate size as per the panel requirement. ARAI will provide single incomer to panel. All further necessary internal cabling is in bidder's scope. Make of electrical switchgear: L&K/siemens/Schneider
Supply,Installation, testing and commissioning of XLPE/PVC insulated PVC Sheathed, 1100V grade GI wire/strip armoured Aluminium / Copper Conductor power & control cable and required lugs/glands respectively.
Supply , Installation,Testing & commissioning of Remote panel for operation of pumping system with on/off button, indication lamp, Emergency switch etc. :
SITC of Perforated 2mm GI Cable tray for piping and cables for all machines including Earthing link jumpers, hardware inclduing cable tray cover etc.
SITC of inverter type Cassette AC with indoor & Outdoor, copper condenser, Green gas, L Type Outdoor stand, antivibration rubber pads, cordless remote and including drilling/core cutting, filling of gap etc. all hardware/fittings required for its installation with following sizes. Suggested Make- Toshiba/Daikin/Mitsubishi/Carrier
SITC of inverter type Cassette AC with indoor & Outdoor, copper condenser, Green gas, L Type Outdoor stand, antivibration rubber pads, cordless remote and including drilling/core cutting, filling of gap etc. all hardware/fittings required for its installation with following sizes. Suggested Make- Toshiba/Daikin/Mitsubishi/Carrier
Supply, installation, testing and commissioning of refrigerant Suction & liquid piping using eddy current free Copper pipes and fittings like elbows, couplers, tee joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods, insulation of pipes using 13 mm thick elastomeric closed cell Nitrile Rubber insulation material having class "O" for fire properties, structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports, tagging to enable tracing connectivity to respective units as per shop drawings to be generated by contractor and approved by consultant. Submission of test reports in approved format forms a part of this item scope. Making up of any leakages occurring during testing / commissioning / first calendar year from handing over, including supply, labor, consumables, refrigerant, top up, oil top up and incidental expenses also forms a part of the scope covered under this item, Making of hole/Core cutting in the wall for piping & Closing etc.
Supply, Installation, Testing & Commissioning of PVC - SCHEDULE 40 Drain Piping With Insulation complete with proper fittings (Elbows, Bends, Tees etc.,) properly installed using GI Slotted Channel / GI Split Clamp Supports. All joints to be properly sealed using SOLVENT CEMENT and allowing a resting period of 24 Hrs. for every sealed joint to ensure proper fusion. The Drain Piping should be properly Insulated with 9mm thick Nitrile Rubber Insulation. Suggested Make-Finolax/Paras etc
SITC of flexible power Cable as per the OEM recommendation from indoor to outdoor poi9nt for all casset AC Units
C-AMC of Air cooled chiller of capacity 330TR or as mentioned in sr No-01 through chiller OEM. AMC includes regular service , spares and breakdown for 3rd Year
C-AMC of Air cooled chiller of capacity 330TR or as mentioned in sr No-01 through chiller OEM. AMC includes regular service , spares and breakdown for 4th Year
C-AMC of Air cooled chiller of capacity 330TR or as mentioned in sr No-01 through chiller OEM. AMC includes regular service , spares and breakdown for 5th Year
L1 is to be evaluated on basic cost including C AMC . However PO is to be issued without C-AMC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
TechnicalBid.pdf
Tender Documents • 1.52 MB
LayoutofHVACSystem.pdf
Tender Documents • 0.21 MB
PriceBid1.xls
Tender Documents • 0.04 MB
PriceBid.xls
PDF • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .