Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC 65 RANJEET NAGAR NEAR SAI HOSPITAL AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.2 L+₹4.1 L (18.5%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹27.1 L+₹5.0 L (22.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹27.6 L+₹5.4 L (24.6%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹27.7 L+₹5.5 L (25.1%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹82,020
Closing Date
5 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT-133001
MANNING AND OPERATION OF ALFA POWER HOUSE AND ALLIED WORKS IN SEC C UNDER GE UTILITY AMBALA CANTT
2021_MES_427851_1
GE(U)/AMB-62/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹82,020
Yes
6 Aug 2021
8 Mar 2021
7 Apr 2021
8 Mar 2021
5 Apr 2021
23 Mar 2021
8 Mar 2021 - 22 Mar 2021
60 days
Amount
SCHEDULE ' A' (SECTION-I) Manning & Operation of Alpha power house system by technically qualified team comprising of 01 No Elect (Skilled) for each shift of 8 hrs for round the clock (03 shifts) at for operation of HT switch gears for maintaining the HT electric supply system recieving from MRS & Alpha Power house and distributing the LT supply of Sect 'C' up to service connections of user end. They are responsible for maintaing the Log sheet of each incoming & out going feeder and maintaing all documents like tripping register,shut down register etc.Contractor will provide all contigencies reqd for maintaining documents, T&P required for maintaining 11 KV HT/440 Volt LT distribution system at site such as measuring instruments,insulation tape etc are deemed to be included in the quoted rate complete all as specified and as directed by Engineer-in-Charge. Note ‘A’ :- (i) Contractor will deploy well experienced and well conversant manpower including Sunday & All Holidays-Elect-01 Nos. (ii) Attendance register will be maintained by the contractor and signed by himself, JE E/M & Engineer -In -Charge.
The rates qouted by the contractor shall be inclusive all taxes like GST,EPF, ESI, LWC as applicable and also include contractor's profit etc. In this connection please refer Note 20 of Sch A/BoQ Notes mentioned in tender documents.
SCHEDULE 'A' (SECTION-II) Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight through joint of size 95-185 Sqmm. Notes (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate. (b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per hour. (d) Straight through joint , 95 to 185, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate.
Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable.with end joint of size 95-185 Sqmm Notes (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges demed to be included in the quoted rate. (b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will lived Rs 500/ per day. (d) Out door/indoor termination upto 185 Sqmm, Labour charges, excavation and making joint deemed to be includeing in quoted rate.
Labour only for attending complaint of LTelectric distribution network UG /OH of all nature like No light, faulty insulator,broken conductor& cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM at Alpha power house Sector `C` complete all as specified and as directed by Engineer-in-Charge. Cost of aluminium lugs saddle of any size for fixing of cables on walls, for finishing work and all fixing accessories required for rectifying the complaints items are included in the rate quoted by contractor. (iii) Cost of materials for laying of cables strecthing of OH conductor, burnt out MCCB`s will be measured and paid separately under relevant items as supply only here in after. (i) All T&P required for electrification work shall be provided by contractor at own arrangements to the trades men & helpers Note ‘A’ :- (i) Contractor will supply following well experienced and well conversant manpower against this items during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays for attending the complaints :- (a) Electrician -02 Nos (b) Helper -02 Nos (ii) 1700 hours to 0100 hours on all working days including Sunday & all Holidays -Elect-01 -Helper-01 (iii) 0100 hours to 0900 hours on all working days including Sunday & Gazetted Holidays -Elect-01 Helper-01
Labour only for attending complaint of HTelectric distribution network UG /OH in day to day maintenance by attendng daily complaints including Sunday and other holidays for round the clock and making the same serviceable in all respects alongwithreplacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories the quoted rate for shall also include checking of transformer,oil level visual inspection of OH lines Earth Resistance of transformer,switch gear GODO etc. The scope also include excavation of cable to new cable accessories like joints, Fuze wire for GOD`s Note : (i) Contractor provide one Electrician and two Helpers for attending and rectifying of complaints. (ii) The materials/items required for rectifying the complaints shall be measured & paid for repartely as supply only here in after in respective items.
Labour only for carry out visual inspection of transformer once ina month including minor maintenance like dusting ,tightening of loose connection HT/LV Side andreplacement aluminium terminal and checking of transformer oil level ,for top up if required ,checking of silca gel ,heating/replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in quoted rate. The record of the same will be submitted in the performa as directed by Engr-in-Charge. Note : The aluminium terminals, silica gel and Transfomer oil if required for top up shall be measured & paid for seperately here in after ''supply only''
Note for item Sr No. 4.00 to 7.00. Note 1. (i) The contractor may have to provide additional resources as per the direction of Engr-in-Charge for speedy disposal of complaints as and when required. Penal recovery at the rate of Rs 500/- per complaint per hour will be levied from the contractor in case of late attending of complaint after reasonable time or 3 hours whichever is more as decided by Engr-in-charge /GE. (ii) The scope of work covers all complaints received from above concern Power houses will be lodged/docketed /attended/completed. The completion will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :-
(a) Blown out fuses
(b) Faulty Insulator
(c) Loose GOD male female contact
(d) Faulty cable joints
(e) O/H Conductor broken
(f) Broken jumpers
(g) Tightening of stay
(h) Stretching of broken loose faulty conductor and binding on insulators up to 3 span.
(j) Clearance and trimming of tree branches upto minimum 3 Mtrs from HT/LT OH lines.
(k) Tightening of service connection as preventive maintenance.
(l) Tightening of bus bar and control devices in HT/LT panel and servicing the same during breakdown or as preventive maintenance.
(m) Tracing fault manually in LT/HT electric lines and underground cables network.
(n) AC complaints like connecting /disconnecting.
(o) Faulty HT/LT switchgears.
(p) Switching ON/OFF street lights at appropriate time as directed by JE/ Engr-in charge. Penal recovery for Rs 500/- per day will be recovered if street light not put ON/OFF at appropriate time.
(q) The area covered under the above power house consists of HT/LT overhead lines, HT/LT underground cables, distribution transformers, HT/LT switch gears etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area.
(r) Any other electric complaint which is considered essential by the department.
(s) Confirmation on completion of any nature of major complaints will be intimated to JE concerned of the area or Engr-in-Charge immediately.
(t) Item required for incorporation in the work will be provided to the contractor by the deptt free for fixing and will be fixed by the manpower provided by the contractor without claiming any extra cost to the deptt..
(u) Contractor will prepare the summary of complaints attended on monthly basis as per pefrorma given by Engr-in-Charge. The summary will be submitted to Engr-in-Charge duly signed by JE and contractor at the end of month.
(v) The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour commissioner act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue through on line in the individual/employ account.
(w) The contractor will carry out visual inspection of transformer once in a month including minor maintenance like dusting, tightening of loose connection andreplacement of aluminium tube terminal and checking level of transformer oil as required at site by using proper T & P as instructed by Engr-in-Charge and record of the same will be submitted in the performa as directed by Engr-in charge.
(x) Maintenance of sub stations including cleaning of In/Out of surrounding areas. Records of periodic maintenance of transformers, GOD, earthing etc will be maintained by the contractor as per direction of JE. Otherwise recovery of Rs 500/- per day shall be imposed on this acount.
(y) Insurance, Education Qualification and experience cert for the personnel employed on duty shall be submitted to Engr-in-Charge before taking over the installation.
(z) Proper Uniform(summer and winter) including shoes shall be provided by the contractor for pers employed on duty as desired by Engr-in-Charge.
(aa) Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Winch , Rope, Bamboo ladder, search light and other tools and will maintain them in working Condition all the time.
(ac) Contractor will have no rights to object the work for carrying out by other agency at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over of the assets will be carried out between the agencies.
Note 2. (a) The Contractor will visit the installation and HT/LT distribution network before quoting their rates. Further no excuse will be entertained on the pretext that machinery/ equipment installed at power houses/ distribution system on the basis of its function ability and vintage.
(b) Most of the electrical machinery (VCB, OCB, relays etc) are of old and obsolete model. The electric supply has to be maintained by carrying out effective comprehensive maintenance under the supervision of JE E/M on the prevailing conditions only
(c) Proper locking arrangement shall be made by the contractor for the assets of the responsible area.
(d) Proper Handing/Taking over of assets of the area and their safe custody will be ensured by the contractor. Deficiency of item will not be entertained at the end of the contract period. Any theft/loss occurred during the currency of the contract will be brought to the knowledge of Engr-in charge immediately.
(e) Contractor will be responsible for the employee’s Food and Rest room near the power house, distance within 01 KM from power house.
(f) In case of employee is married the contractor will be responsible for the resi.
(g) Contractor will be responsible for security pass making from stn HQ within the 01 Month from taking over the installation.
(h) Log sheet,duty roster, attendance register has to provide and maintain by the contractor and must be kept at installations
(j) The contractor has to give the employes names immediately after accepatance of tender to the Engr-in- Charge along with complete documents,failing which recovery of Rs 500/- per person after first month) will be recovered in absence of any documents.
(k) The contractor has to install the display board mentioned firm name, contractor name,contractor No, installation No and min fare wages. The periodical inspection shall be carried out by JE/AGE/GE at installation.
Maintenance of sub Station including cleaning In /out of surroundings areas, zeroing of grass in two pole & four pole structure ,loose filling of sands/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained Quarterly and signed by JE E/M & Engr-in-Charge all as specified and directed by Engr -in-Charge.
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 25-50 Sqmm
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm
Supply only indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.50x240-300 Sqmm
Supply only straight through joint heat shrinkable 1100 Volts for XPLE cable 1100 volt grade of size 3.5/4 x 25-50 Sqmm
Supply only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-120 Sqmm
Supply only straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 150-185 Sqmm
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm
Supply only aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm
Suply only chemical (Round up) for remove unwanted vegitation/grass at various locations .
Supply and fix inreplacement XLPE insulated armoured aluminium conductor cable, oversheathed here of size for 3.5 core 25 Sqmm all as specified and directed.
Description all as per item ser No 19.00 here in before but for 3.5 core 35 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 50 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 95 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 150 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 185 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 300 Sqmm
Description all as per item ser No 19.00 here in before but for 3.5 core 400 Sqmm
Supply and fix in replacement shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed.
Supply and fix inreplacement pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm hight and 65 mm dia with GI spindle two washer and one GI nut complete all as specified and as directed.
Supply and fix in replacement aluminium conductor steel reinforced (ACSR) all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement 1100 volts grade heavy duty cable PVC insulated standred aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core
Supply and fix in replacement GI tubing 50 mm bore light grade for cable protection under roads,floors,along pole complete all as specified and as directed.
Description all as per item ser No 31.00 here in before but 80 mm dia.
Supply and fix inreplacement MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type with thermal magnetic release complete all as specified and directed.
Supply and fix inreplacement MCCB TPN 250 Amps, 415 Volts, 40 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type
Supply and fix inreplacement MCCB TPN 160 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type
Supply and fix inreplacement MCCB TPN 100 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type
Supply and laying sand cushioning to UG cable laid in trenches with river washed dry clean sharp sand and punning to required cover as per SSR Part 1 all as specified and directed.
Supplying and laying bricks common burnt clay sub class 'B' old size for cable protection all as specified. Note:- Old bricks retrived from Item No 19.00 to 26.00 will be re used.
Supply and fix in replacement straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply and fix in replacement straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 150-240 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply and fix in replacement straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 300-400 Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply and fix in replacement cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 70-120 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply and fix in replacement cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 150-240 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge .
Supply and fix in repair LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 5 line as per IS complete all as specified and directed by Engr-in-Charge.
Re-stretching existing/retrieved ACSR conductor on LT /HTpole and binding conductor on insulator properly using new binding wire/jumper wire complete all as directed by Engr-in-Charge. Note : (i) Each Run of line conductor shall be measured & paid for separately.
Supply and fix in replacement steel nuts, bolts, washers of any size required at site as specified and directed by Engineer-in-Charge.
M&L in replacement danger notice board/plate of 1.6mm thick mild steel sheet painting with paint , vitreous enameled white with letters, figures , and conventional skull and bone in signal red colour and fixed with and including MS clamps bolts approved size ofr HT 25cmx20 cm all as directed.
Supply and spread for loose filling of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading llime stone powder under stones complete all as per direction of Engr-in-Charge.
M & L in replacement Anti climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts,bolts,washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed
M&L plain cement concrete type C-2, 1:3:6 (using 40 mm grade aggregate) as in coping, finished even and fair, including necessary from work all as directed at site.
Supply and fix in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified and directed.
Supply only pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed by Engr-in-Charge. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of conract.
Supply only silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 11 KV stations complete as per site requirement complete, all as specified and as directed.
Cutting/Trimming of tree branches falls into OH Line of HT/LT & required minimum 3 Mtr clearance from OH Line to Branches, proper shutdown will be taken and maintained in the register complete all as specified and as directed.
Excavation in trenches not exceeding 1.50M wide and not exceeding 1.50M depth for foundation for laying of pipes/cables/poles/manholes etc and getting out in soft/loose soil completed all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 1.5M and deposting where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.
Note :- Amount of credit of Rs. 115250.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
R N Enterprises
MAYANK ENTERPRISES
Raman Electric Trading Co
Esha Engineers
kapil enterprises
Baliyan Electrical Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .