Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.9 L+₹39,636.44 (2.41%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
10 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, LSGD Dn, Thiruvananthapuram DP, Pattom PO
O/o Executive Engineer, LSGD Division, Thiruvananthapuram DP, Pattom PO, Pincode - 695004
Please refer tender documents
2020_LSGD_396858_10
e-16/LAC-ADS/EELSGDTVM/ 2020-21
Open Tender
Civil Works - Buildings
Item Rate
180 days
Pallichal GP
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,760
Yes
₹50,000
Yes
14 Jul 2023
3 Nov 2020
12 Nov 2020
3 Nov 2020
10 Nov 2020
3 Nov 2020
60 days
Amount
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
od763392/2020_2021 : Filling up low lying and water logged areas with quarry muck spreading in layers,levelling the top at site and consolidation by ramming etc complete for improving the cbr value of subgrade
4.9 : Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
5.1.1a : Prime Coat :- Low porosity <br> Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2.3a : Tack Coat <br>Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 <br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65)
5.12.A.3.2a : Seal Coat - Manual Means - Type C - Bitumen S-65 <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means :- Case - III : Type C <br> (II) Bitumen (S-65)
od763393/2020_2021 : PLAIN CEMENT CONCRETE PAVEMENT WITH M 20 GRADE CONCRETE USING 20 MM AGGREGATE INCLUDING FORMWORK (MOD 6.4)<br>Construction of un-reinforced plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade<br>cement or any other type as per clause 1501.2.2 M 20 (grade),coarse and fine aggregates conforming to IS<br>383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2<br>cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side<br>formwork,spreading the concrete with showels,rakes,compacted using<br>needle vibrators and finished in continuous operation including provision of contraction<br>and expansion ,construction joints,curing of concrete slabs for 14 days,using<br> water finishing to lines and grade as per drawing and Technical<br>Specifications clause 1501
od763406/2020_2021 : Construction of plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade<br>cement or any other type as per clause 1501.2.2 maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer layed and finished RECONCRETE /IRISH
3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
od772291/2020_2021 : Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204<br><br>III. Random rubble masonry <br>(iii)In cement mortar (1:5)
od763394/2020_2021 : P.C.C grade M10 providing concrete for plain/ reinforced concrete in open foundations, etc. complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I.P.C.C grade M10 - 1:3:6
od763395/2020_2021 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203<br><br>I.P.C.C grade M 10<br><br>(i)Nominal mix 1:3:6
11.4.2.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
11.8 : Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
od763396/2020_2021 : Construction of Embankment with Material obtained from Borrow pits Constuction of embankment with approved material obtained from borrow pits with a lift upto 1,5m, transporting to site, spreading grading to required slope and compacting by ramming - By manual means
od763397/2020_2021 : S/F Name board of size 75*60 cm . installed in the appropriate place visible to public made of brick wall with granite plaque should be inserted and engraving letters etc complete as per the direction of deptl officers at site .
P CHANDRAN NADAR
Bidder Name
Jayaraj D M
P CHANDRAN NADAR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_564872.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .