Estate Manager
Estate Manager, EMU RnD Estate, Sanchar Vihar, Dehradun
REPAIR TO FIRE ENGINES n PUMPS, HT n LT PANELS IN PHOTONIC, OPTICAL n MMG BUILDINGS AND WIRING OF FIRE ALARM SYSTEM IN MMG BUILDING AT IRDE, DEHRADUN.
2021_DRDO_641894_1
EMU/DDN/02/FIRESYSTEM/01/IRDE
Limited
Miscellaneous Works
Works
120 days
Dehradun
As per NIT
4 documents required · 4 mandatory
₹0
Exempted
21 Sept 2021
4 Aug 2021
24 Aug 2021
4 Aug 2021
23 Aug 2021
5 Aug 2021
Amount
Part - I : Repair to Fire Engine & Pumps Carrying out servicing of fire engine and connected pump at Photonic Bldg including replacing of defective parts as mentioned below, Make: Kirloskar, Capacity- 59.25KW/ 79Hp, S.No: 6H-2005-10/0200001 :-
Supply and replacement of defective fuel filter kit complete of existing make
Supply and replacement of coolant 26 ltrs, Make: Kirloskar/Servo.
Supply and replacement of engine oil 20 ltrs, Make: Servo/ Kirloskar.
Supply and replacement of defective fan belt, Make: Fenner or equivalent
Cleaning of radiator assembly complete
Servicing of fuel injection pump and repair of defective parts complete all as specified and directed by Engr-in-Charge
Taking down injector from fire engine and refixing after necessary repair complete all as specified and directed by Engr-in-Charge
Taking down fire hydrant pump carefully for over hauling, replacing defective parts i.e. service kit of water pump, rotary shaft, packing kit & bearing etc, Make: Kirloskar or equivalent
Supply and replacement of defective hose pipe set complete of existing make.
Supply and replacing of defective fuel pipe complete of existing make.
Taking out sprinklers from fire hydrant system & Cleaning it thoroughly including choked part of fire hydrant complete all as directed by Enr-in-charge.
Carrying out servicing of fire engine and pumping set at MMG Bldg , as mentioned below, Make: Kirloskar, Capacity- 47.8KW/ 65Hp, S.No: 06-1003-10/ 1000005 :-
Supply and replacement of defective fuel filter kit complete of existing make
Supply and replacement of air cleaner hose pipe of existing make
Supply and replacement of engine oil 20 ltr, Make: Servo/ Kirloskar.
Supply and replacement of defective fan belt, Make: Fenner or equivalent
Servicing of fuel injection pump and repairing of defective parts complete all as specified and directed by Engr-in-Charge
Taking down injector from fire engine and refixing after necessary repair complete all as specified and directed by Engr-in-Charge
Taking down fire hydrant pump carefully for over hauling, replacing defective parts i.e. service kit of water pump, rotary shaft, packing kit & bearing etc, Make: Kirloskar or equivalent.
Taking out sprinklers from fire hydrant system & Cleaning it thoroughly including choked part of fire hydrant all as directed by Engr-in-Charge complete
Carrying out servicing of fire engine and connected pump at Optical Bldg including replacing of defective parts as mentioned below, Make: Kirloskar, Capacity- 62KW/ 85Hp, S.No: 4H-2709-16/1000236:-
Supply and replacement of defective fuel filter kit complete of existing make
Supply and replacement of coolant 26 ltr, Make: Kirloskar/Servo.
Supply and replacement of engine oil 20 ltr, Make: Servo/ Kirloskar.
Supply and replacement defective fan belt Make: Fenner or Equivalent.
Cleaning of radiator assembly complete.
Servicing of fuel injection pump and repair of defective parts complete all as specified and directed by Engr-in-Charge
Taking down injector from fire engine and refixing after necessary repair complete all as specified and directed by Engr-in-Charge
Taking down fire hydrant pump carefully for over hauling, replacing defective parts i.e. service kit of water pump, rotary shaft, packing kit & bearing etc, Make: Kirloskar or Equivalent.
Supply and replacement of defective hose pipe set complete of existing make.
Supply and replacement defective fuel pipe complete of existing make.
Taking out sprinklers from fire hydrant system & Cleaning it thoroughly including choked part of fire hydrant all as directed by Engr-in-Charge complete
Supply and replacement of lead acid battery, 12 volts,150 AH, Make: Tata Green/ Exide
Supply and replacement of lead acid battery, 12 volts,180 AH, Make: Tata Green/ Exide
Part- II : Repair To LT & HT Panels
Disconnecting & taking out LT ACB, capacity 800 amps Make: L&T, SNo.BT 415470 from Main LT Panel Board at plant room of MMG Bldg for servicing, overhauling & testing complete and refixing it after repair as per followings :- (a) Cleaning of breaker with CRC-26. (b) Removal of old grease and lubricating with new grease (c) checking all nut-bolts and resetting push button mechanism of tripping system in breaker. (d) Checking proper tightening of hardware. (e) Checking condition and alignment of jaw contact with cradle terminals. (f) Checking wiring and replacing unserviceable wiring as required. (g) Checking & adjusting gap between hylum sheet and side plate, (h) checking proper closing of poles together, checking working of anti-pumping device, alignment of SIC and its operation (i) checking scrapping earth alignment, checking condition of arc chute and ACB tripping through shunt release. (j) Checking continuity, ensuring proper change over of aux contact block and setting of release as per the load.
Disconnecting & taking out LT ACB, capacity 1250 Amps, Make: L&T, SNo. BT-CT-417386 from Main LT Panel Board at plant room of MMG Bldg for servicing, overhauling & testing complete and refixing it after repair as per followings :- (a) Cleaning of breaker with CRC-26. (b) Removal of old grease and lubricating with new grease (c) checking all nut-bolts and resetting push button mechanism of tripping system in breaker. (d) Checking proper tightening of hardware. (e) Checking condition and alignment of jaw contact with cradle terminals. (f) Checking wiring and replacing unserviceable wiring as required. (g) Checking & adjusting gap between hylum sheet and side plate, (h) checking proper closing of poles together, checking working of anti-pumping device, alignment of SIC and its operation (i) checking scrapping earth alignment, checking condition of arc chute and ACB tripping through shunt release. (j) Checking continuity, ensuring proper change over of aux contact block and setting of release as per the load.
Disconnecting & taking out LT ACB from LT panel board at plant room of MMG Bldg & Overhauling complete, capacity 1250 Amps, 415 volts, Ac, 50 Hz, S. No. CT- 417343, Make: L&T, replacing of defective parts as mentioned at S.No.4.04 to S.No. 4.09, here-in-after as directed by Engr-in- charge. (Note: Replaced spare parts shall be paid separately).
Supply and replacement of FRCD Mechanism part, capacity 1250 Amps, of existing make.
Supply and replacement of protection release (SR18G), capacity 1250 Amps, of existing make.
Supply and replacement of current transformer, of existing make.
Supply and replacement of spring charging motor, 240 volts, AC, of existing make.
Supply and replacement of Shunt Release (tripping), 240 volts, AC, of existing make.
Supply and replacement of Under voltage Release, 240 volts, AC, of existing make.
Taking out Vaccum Circuit Breaker, 11 KV, 3 Ph, AC, Type-ALAI/XLV, capacity 400 Amps, S.No.0460VR Make: Crompton Greaves from HT panel board at plant room of Photonics Bldg and carrying out servicing and testing as mentioned below:- Cleaning all dust and dirt deposits, foreign particles and degreasing various parts of VCB. Cleaning all parts with cleaning agent such as CRC-2-26. Checking the hardware for any wear & tear, regreasing the VCB parts as recommended including checking all terminals connections for tightness. Refixing the VCB in the HT panel board and testing complete all as directed by Engr-in-charge. Testing of VCB shall include insulation test with digital IR tester, time interval test with microprocessor unit, resistance measurement of closing coil, mechanical and electrical closing and tripping check, charging of spring through manual and electrical check and Hi-pot test.
Taking out defective charging gear of Vaccum Circuit Breaker, 11 KV, 3 Ph, AC, Type-ALAI/XLV, capacity 400 Amps, S.No.0460VR Make: Crompton Greaves from HT panel board at plant room of Photonics Bldg and supply & fixing new charging gear including testing complete.
Taking out Air Circuit Breaker, 440 V, 3 Ph, AC, Capacity 1000 Amps, S.No.1000EM173P Make: Crompton Greaves from LT panel board at plant room of Photonics Bldg and carrying out servicing and testing as mentioned below:- Cleaning all dust and dirt deposits, foreign particles and degreasing various parts of ACB. Cleaning all parts with cleaning agent such as CRC-2-26. Checking the hardware for any wear & tear, regreasing the ACB parts as recommended including checking all terminals connections for tightness. Refixing the ACB in the LT panel board and testing complete all as directed by Engr-in-charge. Testing of ACB shall include release test, CT test with resistance, resistance measurement of closing coil, tripping coil, and spring charge motor coil. Mechanical and electrical closing and tripping check, charging of spring through manual and electrical check etc complete.
Disconnecting & taking out LT ACB, capacity 800 amps Make: L&T, from Main LT Panel Board at plant room of Photonics Bldg for servicing, overhauling & testing complete and refixing it after repair as per followings :- (a) Cleaning of breaker with CRC-26. (b) Removal of old grease and lubricating with new grease (c) checking all nut-bolts and resetting push button mechanism of tripping system in breaker. (d) Checking proper tightening of hardware and presence of circlips. (e) Checking condition and alignment of jaw contact with cradle terminals. (f) Checking wiring and replacing unserviceable wiring as required. (g) Checking & adjusting gap between hylum sheet and side plate, (h) checking proper closing of poles together, checking working of anti-pumping device, alignment of SIC and its operation (i) checking scrapping earth alignment, checking condition of arc chute and ACB tripping through shunt release. (j) Checking continuity, ensuring proper change over of aux contact block and setting of release as per the load.
Disconnecting electrical connection of Servo Stablizer, AC, 3 Ph, 50 Hz, rated input voltage 300 - 470 volts and output voltage 400 +- 1 %, capacity 750 KVA, S.No. 2212377 Make: VINITEC. Carrying out servicing & repair work, reconnecting electrical connections and conducting routine testing of servo stablizer, auto - manual testing and voltage stability test.
Supply and replacement of defective motor of servo stabilizer of existing make.
Supply and replacement of defective gear of servo motor of existing make.
Part-III : Repair To Wiring Of Fire Alarm System In MMG Bldg
Material & Labour for 2 x 1.5 sq. mm sizes of FRLS PVC insulated copper conductor, stranded, single core cable in the existing surface/ recessed steel/ PVC conduit including taking out old unserviceable wire as required. Make: Havells/ Polycab/ Legrand.
Material & Labour of 20 mm dia, medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. Make: AKG/ Astral/ Kalinga.
Supply, replacement & testing smoke detector, 2 wire based detector, advance algorithm to provide advanced detection & discrimination. Operating voltage range 9 volts to 32 VDC volts non-polerised, alarm current 2mA, with dual red LED for 360 degree visibility. Make:Palex/ Plladuiam/ Agni/ Realex.
Supply, replacement & testing heat detector, 2 wire based detector, advance algorithm to provide advanced detection & discrimination. Operating voltage range 9 volts to 32 VDC volts non-polerised, alarm current 2mA, with dual red LED for 360 degree visibility. Make:Palex/ Plladuiam/ Agni/ Realex.
Supply, replacement & testing response indicator weight 20 gm, power input 24 volts dual LED based. Make: Palex/ Plladuiam/ Agni/ Realex.
Supply, replacement & testing of fire alarm (Hooter), with MS housing, power input 100 volts (with LMT) or 12/24 volts AC speaker, 4 watts. Make: Palex/ Plladuiam/ Agni/ Realex.
Supply, replacement & testing of manual call point in ABS compatible with all conventional fire control panel with alarm test key facility, glass protected. Make: Palex/ Plladuiam/ Agni/ Realex.
RefAir India Pvt. Ltd.
CLYMATE CONTROL
KUKREJA ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .