Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹31.8 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹3.4 LRejected-Finance | ₹3.4 L | L2 | Rejected-Finance L2 |
| 3 | L3₹35.8 LRejected-Finance | ₹35.8 L | L3 | Rejected-Finance L3 |
| 4 | L4₹36.3 LRejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹36.3 L | L4 | Rejected-Finance L4 |
| 5 | L5₹43.0 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹43.0 L | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | rajengineers L2 | Sukhi Electricals L3 | M/s SK Traders L4 | jagdish machinery stores L1 | JAMNAGAR ELECTRIC AND MACHINERY CO L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M/L for painting to Ring Main Unit (RMU) of any type indoor/outdoor(for outside only) not more than 6 ways with two coat of synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge. | 35 | EACH JOB | 2,000 ₹70,000 | 2,000 ₹70,000 | 3,000 ₹1.1 L | 1,500 ₹52,500 | 2,500 ₹87,500 |
| 2.00 | Material and labour for repairing to body of Compact Sub station, replacing door hinges,locking arrangements complete all as specified as directed by Engineer in charge. | 10 | EACH JOB | 2,000 ₹20,000 | 5,000 ₹50,000 | 2,000 ₹20,000 | 2,500 ₹25,000 | 4,000 ₹40,000 |
| 3.00 | M/L for painting to Compact Sub station with two coat of synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge. | 10 | EACH JOB | 2,000 ₹20,000 | 5,000 ₹50,000 | 5,000 ₹50,000 | 2,000 ₹20,000 | 3,000 ₹30,000 |
| 4.00 | Disconnecting XLPE cable of any size from MCB/MCCB/Busbar chamber / LT cables etc for repair /replacment job and reconnecting cable after replacing worn out /damaged lugs, proper clamping, extended terminal link, repair to panel door replacement of door hinges, painting to disturbed surface complete etc all as specified as directed by Engineer in charge. | 80 | EACH JOB | 300 ₹24,000 | 500 ₹40,000 | 500 ₹40,000 | 250 ₹20,000 | 700 ₹56,000 |
| 5.00 | M/L for painting of LT panel indoor/outdoor type (from outside only)of any size with one coat synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge. | 300 | EACH JOB | 250 ₹75,000 | 300 ₹90,000 | 450 ₹1.4 L | 350 ₹1.1 L | 500 ₹1.5 L |
| 6.00 | Supply and fixing in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including fixing arrangements complete all as specified as directed by Engineer in charge. | 33 | Each | 4,600 ₹1.5 L | 3,500 ₹1.2 L | 5,000 ₹1.6 L | 3,300 ₹1.1 L | 6,900 ₹2.3 L |
| 7.00 | Supply and fixing in replacement of LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including fixing arragnement complete all as specified as directed by Engineer in charge. | 25 | EACH | 5,100 ₹1.3 L | 4,500 ₹1.1 L | 6,500 ₹1.6 L | 4,500 ₹1.1 L | 7,500 ₹1.9 L |
| 8.00 | Supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified as directed by Engineer in charge. | 75 | EACH | 200 ₹15,000 | 200 ₹15,000 | 100 ₹7,500 | 300 ₹22,500 | 460 ₹34,500 |
| 9.00 | Supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 20x15cm size complete all as specified as directed by Engineer in charge. | 50 | EACH | 200 ₹10,000 | 200 ₹10,000 | 200 ₹10,000 | 300 ₹15,000 | 450 ₹22,500 |
| 10.00 | Taking out / down old existing LT 1100 volt grade cables of size 3.5X185 Sqmm, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all as specified as directed by Engineer in charge.
Note : Excavation shall be measured and paid for separately | 200 | Running Metre | 25 ₹5,000 | 10 ₹2,000 | 5 ₹1,000 | 25 ₹5,000 | 15 ₹3,000 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Nov 2025, 6:00 pmClosed
Lt Col Sumukh Swaroop
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No 1 Jamnagar 361003
REPAIR/ MAINT OF E/M SWITCH YARD WITH ALLIED MISC ITEMS AT VARIOUS LOCATION UNDER GE (AF) JAMNAGAR NO 1
2025_MES_736319_1
8371/E8
Open Tender
Miscellaneous Works
270 days
JAMNAGAR
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No 1
₹90,000
Yes
6 Feb 2026
22 Oct 2025
20 Nov 2025
22 Oct 2025
19 Nov 2025
5 Nov 2025
Amount
M/L for painting to Ring Main Unit (RMU) of any type indoor/outdoor(for outside only) not more than 6 ways with two coat of synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge.
Material and labour for repairing to body of Compact Sub station, replacing door hinges,locking arrangements complete all as specified as directed by Engineer in charge.
M/L for painting to Compact Sub station with two coat of synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge.
Disconnecting XLPE cable of any size from MCB/MCCB/Busbar chamber / LT cables etc for repair /replacment job and reconnecting cable after replacing worn out /damaged lugs, proper clamping, extended terminal link, repair to panel door replacement of door hinges, painting to disturbed surface complete etc all as specified as directed by Engineer in charge.
M/L for painting of LT panel indoor/outdoor type (from outside only)of any size with one coat synthetic enamelled paint of existing colour after proper cleaning , dusting, de-rusting complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including fixing arrangements complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement of LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including fixing arragnement complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 20x15cm size complete all as specified as directed by Engineer in charge.
Taking out / down old existing LT 1100 volt grade cables of size 3.5X185 Sqmm, aluminium conductor, XLPE, armoured, removal to store for re-use or for credit, complete all as specified as directed by Engineer in charge. Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 10 here-in-before but 150 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No.10 here-in-before but 120 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 95 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 70 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 50 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 35 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 25 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 10 here-in-before but 25 Sqmm 2 Core size complete all as specified as directed by Engineer in charge.
Relaying, jointing, testing and commissioning, already taken out existing LT under ground cables XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor cross sectional area 185 Sqmm 3.5 core, 1100 volts grade, laid in trenches, along poles or passing through pipes or laid under floor or through/on walls etc, complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 150 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 120 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 95 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 70 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 50 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 35 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 25 Sqmm 3.5 Core size complete all as specified as directed by Engineer in charge.
All as per Serial Item No. 19 here-in-before but 25 Sqmm 2 Core size complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 3.5 core complete all as specified as directed by Engineer in charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 2 core complete all as specified as directed by Engineer in charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified as directed by Engineer in charge.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified as directed by Engineer in charge.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified as directed by Engineer in charge.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified as directed by Engineer in charge. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying un-reinforced precast concrete cable cover, class LV,type 1 with peak, size 250mm x 150mm x 40mm complete all as specified as directed by Engineer in charge.
Laying only old un-reinforced precast concrete cable cover, class LV,type 1 with peak, size 250mm x 150mm x 40mm complete all as specified as directed by Engineer in charge.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified as directed by Engineer in charge. Note: Boring of holes under road etc. shall be measured and paid separately.
All as per item No 43 here - in before but GI pipe 80mm complete all as specified as directed by Engineer in charge.
All as per item No 43 here - in before but GI pipe 50mm complete all as specified as directed by Engineer in charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 2/4 core, 16 to 25 Sqmm complete all as specified as directed by Engineer in charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 35/50 Sqmm complete all as specified as directed by Engineer in charge.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 70/95 Sqmm complete all as specified as directed by Engineer in charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 50 to 95 sqmm,Indoor/Outdoor type complete all as specified as directed by Engineer in charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 120 to 185sqmm,Indoor/Outdoor type complete all as specified as directed by Engineer in charge.
Supply and fixing in replacemnt of MCCB 320A 4 pole 415 V 50 KA adjustable Thermal and fixied magnetic setting in existing LT panel complete all as specified as directed by Engineer in charge.
Supply and fixing in replacemnt of MCCB 400A 4 pole 415 V 50 KA adjustable Thermal and fixied magnetic setting in existing LT panel complete all all as specified and directed be Engineer in Charge
Supply and fixing in replacemnt of MCCB 630A 4 pole 415 V 50 KA adjustable Thermal and fixied magnetic setting in existing LT panel complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required but 25x3mm aluminium strip complete all as specified as directed by Engineer in charge.
Supply and fixing in replacement of PCC earth pit cover complete all as specified as directed by Engineer in charge.
M & L Hard core, broken to gauge n exc 63 mm complete all as specified as directed by Engineer in charge.
M & L Cement concrete in foundations, filling and mass concrete Type C2 1:2:4 (40mm grade aggregate ) complete all as specified as directed by Engineer in charge.
Supply and fixing in replacemnt of HDPE pipe 50mm for cable protection complete all as specified as directed by Engineer in charge.
Supply and fixing in replacemnt of HDPE pipe 80mm for cable protection complete all as specified as directed by Engineer in charge.
M & L for complete removal of existing treatment of old surface of wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50fm/ltre and UV resitance as per IS 15489:2004 ,Alkaali & fungal resistance ,dirt resistance required shade (company Depto Tinned ) with silcon additives @1.43 litre/10 Sqm in any pattern over and including priming coat of exterion primer applied @ 0.90 Ltrs/10 SQm complete all as specified as directed by Engineer in charge.
rajengineers (BID ID -3471637)
Sukhi Electricals (BID ID -3472448)
M/s SK Traders (BID ID -3472790)
JAMNAGAR ELECTRIC AND MACHINERY CO (BID ID -3477761)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
PS.pdf
Tender Documents • 0.83 MB
BOQ_824455.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid