| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | ₹16.4 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.6 L+₹1.1 L (6.95%)Rejected-Finance | ₹17.6 L+₹1.1 L (6.95%) | L2 | Rejected-Finance Other Than L1 |
| 3 | L3₹17.9 L+₹1.4 L (8.77%)Rejected-Finance | ₹17.9 L+₹1.4 L (8.77%) | L3 | Rejected-Finance Other Than L1 |
| 4 | L4₹18.6 L+₹2.2 L (13.2%)Rejected-Finance | ₹18.6 L+₹2.2 L (13.2%) | L4 | Rejected-Finance Other Than L1 |
| 5 | L5₹21.7 L+₹5.2 L (31.9%)Rejected-Finance | ₹21.7 L+₹5.2 L (31.9%) | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Aug 2021, 6:00 pmClosed
GE(KH)YOL
GE(KH)YOL
REPAIR TO WATER SUPPLY TANKS, PIPES AND DRAIN INCLUDING WATER PROOFING/PROVIDING AT YOL CANTT.
2021_MES_464044_1
GE/Y-23/2021-22
Open Tender
Civil Works
Item Rate
183 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH)YOL
₹40,000
Yes
16 Sept 2021
2 Aug 2021
30 Aug 2021
2 Aug 2021
28 Aug 2021
16 Aug 2021
Amount
SCHEDULE 'A' PART-I Dismantling floor, hearth or wall tiling including cement mortar bedding (But not backing), Removal of tiles and all looses gravel, dirt , oil, grease and foreign matter to make open stone masonary expose for repair before applivation of waterproofing treatment. Ensure that the moisture content in the prepared surface dose no exceed 5% and dumping of material deposited at designated site complete all as spd and directed by Engineer-in-charge. all as specified and as directed.
Repairing / treatment of all cracks , joint and honey combs with polymer modified fiber reinforced morter as per metholodogy specified by the manufacturer . Average depth of honey comb repairing 20-25 mm thick, complete all as spd and directed by Engr-in-charge. Make : Fosroc/BASF/STP or its equivelant.
M&L for Plastering over Stone Masonary : Plastering - vertical/horizontal wall of 20 mm thick over concrete masonary with cement and sand ratio 1:4 to provide levelled surface with integral water proofing liquid additive for concrete, mortar and plasters in the ratio of 200ML / 50 Kg of cement. Ensure that the surface should be levelled.Work should be process with guideline as per methodology complete all as spd and diredted by Engr-in-charge. Make : Fosroc/BASF/STP or its equivelant.
M&L for Cementitious Coating - Floor (Horizontal/Vertical Area) : Prime the area with slurry by mixing one part of acrylic polymer with two parts of neat cement i.e. in the ratio 0.5 Kg acrylic polymers and 1 Kg cement. Apply two component cementitious elastomeric polymers base water proof coating on clean and dampen surface with stiff fibre brush. Apply first coat @ 1.25 Kg per Sqmt per coat in one direction. Apply second coat when the first coat is touch dry @ 1.25 Kg per Sqm per coat in perpendicular direction to first coat direction. Allow to dry for 24 hr before moist curing. Do not apply water through a hose or pressurized nozzle. Protection screed 25mm thick M-15 Grade screed adding of integral water proofing liquid 200ML per 50 Kg of cement PCC to protect the treated surface on all horizontal surface. Work should be process with guideline methodology complete all as spd and directed by Engineer-in-charge. Make : Fosroc/BASF/STP or its equivelant
M & L for Epoxy Coating (Approved by CFTRI) PRIMER : Apply two component penetrative epoxy based primer @ 160 gms per Sqmt on cured surface. Note the moisture should not be more than 5%. EPOXY COATING : Apply food grade epoxy coating tested by CFTRI) @ 500 Gms per Sqmt in two coats. Apply two coats at right angles to each other. This way the second coat will cover any blemishes of the first coat. Allow first coat to become tack free before the second coat is applied. Work should be process with guideline as per methodology complete all as spd and directed by Engineer-in-charge. Make : Fosroc/BASF/STP or its equivelant
M&L for Polyurethane Top Coating (Approved by CFTRI) PRIMER : Apply two component penetrative epoxy based primer @ 160 gms per Sqmt on cured surface. Note the moisture should not be more than 5%. PU COATING : Apply two component, liquid aliphatic polyurethane based UV and weather resistant coating approved by CFTRI) @ 300 Gms per Sqmt in two coats. Apply two coats at right angles to each other. This way the second coat will cover any blemishes of the first coat. Allow first coat to become tack free before the second coat is applied. Work should be process with guideline as per methodology complete all as spd and directed by Engineer-in-charge. Make : Fosroc/BASF/STP or its equivelant
LOKESH AND CO.
surinder kumar jindal & bros.
M/S VIG AND COMPANY
KISHAN CONTRACTOR
M/S RANA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .