Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.3 L+₹2.6 L (6.47%)Rejected-Finance 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹42.4 L+₹2.7 L (6.70%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹42.7 L+₹3.0 L (7.52%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
ADDITION/ALTERNATION TO BLDG NO. P-58 AT CGDHQ-1 AND PROVISION OF WIRE NETTING HANGAR AT ICGAE PORBANDAR UNDER GE I CG PORBANDAR
2023_MES_620177_1
8916
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I CG PORBANDAR
₹75,000
Yes
16 Nov 2023
22 Sept 2023
21 Oct 2023
22 Sept 2023
19 Oct 2023
7 Oct 2023
Amount
SCHEDULE 'A' B/R ITEMS
Taking down chowkhat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. as specified in SSR Part I, Section 8, clause 8.20 (a), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 40mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing 30mm thick factory made 100% solid WPC (Wood polymer composite) Solid Plain / Prelam / Enrouted Plain / Enrouted Painted flush Door Shutter of required size comprising of Virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibers (Wood Powders/rice husk/Wheat husk) and Non toxic additives made from Extrusion process WPC foam sheet single Extruded (Inner) with density not less than 650 Kg/cbm manufacture by any ISO 9001-2015 Certified Company, having good screw holding capacity (Screw withdrawl strength of 2000 N (face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread flame of Class 'A' category with Property of being Termite/Borer Free, Water/Moisture Proof, Fire Retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws for WC / Bathroom / Toilet / Kitchen / Balcony Doors, complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing and Fixing factory made 100% Solid WPC (Wood Polymer Composite) Door frame of size 75mm x 50mm made from wood Polymer Composite (Single Extruded process) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium carbonate and Natural Fibers (Wood Powder/Rice Husk/Wheat Husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & Screwed with full body threaded star headed screws having minimum frame density of 780 Kg /cbm manufacture by any ISO 9001-2015 certified Company, having good screw holding capacity (Screw withdrawal strength of (Min 990N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Draft Fasteners/Hold Fast of required dia and length for WC/Bathroom/Toilet and external uses, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+-0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 +- 0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area not exceeding 2.00 Sqm each fixed from ground floor to height of 2nd floors, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 7mm thick aluminium grills of make "Decogrill" model DG 104 surrounded by aluminum 'C' channel and size of opening 75mm x 75mm, from ground floor to height of 2nd floors, complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 300 mm long MS ordinary rat tail rod pattern springs including roller and roller, complete all as specified and directed by Engineer-in-Charge.
Dismantling of boarding, any description fixed in any position with nails i.e. in cupboard shutters, partitions and similar position, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 25mm thick flush shutters, solid core construction, with block board core and both faces covered with decorative face veeners with lipping / frame to match, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 100mm long medium weight, cold rolled mild steel Butt hinges, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 150mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 100mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 4mm thick sheet glass,ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 3mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing staineless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium/pvc sections, complete all as specified and directed by Engineer-in-Charge.
Demolition of Concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75mm thick cement concrete type C-1, (1:3:6) using 20mm graded stone aggregate as in plinth protection etc., complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non-skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in Cement Mortar (1:4), complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non-skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on skirting over with and including 10mm thick backing coat in Cement Mortar 1:3, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors, over and including 15mm thick screed in Cement Mortar (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified and directed by Engineer-in-Charge.
Material and labour for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 15mm screed bed or bedding layer in 1:4 Cement Mortar, complete all as specified and directed by Engineer-in-Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortar etc., complete all as specified and directed by Engineer-in-Charge.
Material and labour for granite (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window, cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including , grinding, polishing, moulding the edges and polishing and including over screed bed 15 mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 20 to 25mm thick machine cut Kota stone (single piece of required size for steps) flooring over cement screed base laid and jointed with grey cement slurrry mixed with pigments to match the shade of the slab including rubbing and Mirror polishing, over and including 15mm thick screed bed in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge. Note:- Kota stone in Stair case should be provided in single piece upto 1.5 Metre length or as per site requirements.
ditto - all as above item No. 32.00 but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting, dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed, complete all as specified and directed by Engineer-in-Charge. Note:- Kota stone in Stair case should be provided in single piece upto 1.5 Metre length or as per site requirements.
Demolition of reinforced cement concrete of any description and in any position not otherwise speccifically provided, complete all as specified and directed by Engr-in-Charge..
Material and labour for RCC 1:2:4 ,Type B-1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formsworks, complete all as specified and directed by Engineer-in-Charge.
Material and labour for precast RCC 1:2:4, Type B-1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material and labour for formwork of soffits of suspended slabs such as roof slab, floor slabs, landigs, shelves and similar work, not exceeding 200mm thick rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Dismentaling/ Demolition of brick work or stone masonary or RCC Precast Jali & Jafari built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-Charge.
Material and labour for porbandar stone masonary, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on stone wall including racking out joints, hacking for key scrubbing with water etc., complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:3 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge..
Material and labour for 15mm thick rendering in Cement Mortar 1:6 to brick / concrete wall surfaces trowelled to even & smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparing surfaces plastered or unplastered new surface of walls applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. (Note after painting, cleaning of all floors, glass & furniture by own arrangement).
Material & Labour for complete removal of existing treatment by washing down and smoothing old surface of walls including scrapping and applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. (Note after painting, cleaning of all floors, glass & furniture by own arrangement).
Material & Labour for preparing surfaces plastered or unplastered new surface of ceiling applying two coats of oil bound distemper over a coat of primer, two coats as per manufacturer's instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. (Note after painting, cleaning of all floors, glass & furniture by own arrangement).
Material & Labour for preparing surfaces plastered or unplastered old surface of ceiling applying two coats of oil bound distemper over a coat of primer two coats as per manufacturer's instruction with smooth roller finish, complete all as specified and directed by Engineer-in-Charge. (Note after painting, cleaning of all floors, glass & furniture by own arrangement).
Material and labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC Floor trap 75mm bore with grating including jointing using solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutter or RWP of any description including fittings, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 110mm dia PVC rain water pipe of pressure single socketed with rubber joint, jointed with solvent joint fixed to wall, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 110mm dia PVC bend any radius, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipes75mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) pipes75mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) bends 110mm bore with/without access door any radius, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) bends 75mm bore with/without access door any radius, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) single junction 'T', 75mm bore with access door any radius, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC (SWR) single junction 'T', 110mm bore with access door any radius, complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15mm bore dia, steel tubing & connections, complete all as specified and directed by Engineer-in-Charge.
Taking up or down for 20mm bore steel water tubing galvanised with connection, complete all as specified and directed by Engineer-in-Charge.
Taking up or down for 25mm bore steel water tubing galvanised with connection, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 16mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 25mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Brass Elbow for special fitting of 16mm bore CPVC pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Brass Tee for special fitting of 16mm bore CPVC pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Male Brass threaded Adaptor Tee for special fitting of 16mm bore CPVC pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15 mm bib tap ( fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer-in-Charge. Make : ESSCO Jaguar / Prayag / Somany
Supply and fixing in repairs brass CP shower rose 125mm size fancy type with swivel joint any size including fixing to steel pipe/union for 15mm dia, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair PVC connection of 15mm dia length 600mm, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Vitreous China wash down water closet pan (pedestal pattern), white with P or S trap with and including plastic water closet seat cover, connection to trap, flushing pipe & antisyphonage pipe etc., including necessary materials for fittings & making good to floor, complete all as specified and directed by Engineer-in-Charge..
Supply and fixing for in repairs 10 Ltrs. Capacity PVC flusing cistern low level slimline or equivalen make / model with all accessories, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for in repair Vitreous China ware wash hand basin white, flat back, size 550x400 mm size with cutting for and pinning ends of brackets or erecting stand including 32 mm PVC bottle trap, chromium plated 15mm pillar cock, PVC connection 450 mm long, CP waste coupling, 32 mm dia PVC pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Peg set of three made of teak wood and Aluminium pegs of size 10cm, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 20mm Aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 15mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for 15mm dia CP two way tap fixed in pipe, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for in repair 15 mm dia CP Health Faucet with 1mtr long lead fixed in pipe, complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks exceeding 500 & 1000 lit capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hositing if required reconnecting and re-fixing in position, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair for 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete with waste coupling and waste pipes of suitable capacity, complete all as specified and directed by Engineer-in-Charge. Make- Carysill or equivalents
Supply and fixing for in repair 15mm bore stop valves, cast copper alloy fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 15mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair 20mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Stop valves of size 15mm dia fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair harrison rails (Curtain rod/drapery rod), 20mm dia, powder coated with and including fency type PVC bracket 2 Nos of each opening and side stopper fency type powder coated of required shape and size 2 Nos of each opening, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Plate racks made out of 1mm thick, Stainless steel, of size 750x600x 250 mm all as specified and directed (make of plate to be used shall be SAIL, IINDAL, SURAJ or equivalent as approved by GE), complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 40mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 5mm thick in one layers on concrete surface cement sand mortar 1:3 using water proofing compound @ 3% by weight of cement finished even fair and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
Material and labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3 Kg/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over mineral surface.
Supply only water proofing compound complete all as specified and directed by Engineer-in-Charge.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation and mass concrete, complete all as specified and directed by Engineer-in-Charge.
Material and labour for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds, complete all as specified and directed by Engineer-in-Charge.
Material and labour Hardcore, broken stone /boulders to gauge exceeding 63 mm and not exceeding 100mm, complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth and getting out Soft/disintegrated rock, complete all as specified and directed by Engineer-in-Charge.
Material and labour moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75mm thick Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base of floors, complete all as specified and directed by Engineer-in-Charge.
Material and labour 10mm thick vitrified paving tile of area exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15 mm thick cement mortar 1:4, including dismantling old unserviceable tiles, complete all as specified and directed by Engineer-in-Charge. The model/Pattern of tile shall be as approved by GE
Material and labour for PCC (1:2:4) type B-0 using 12.5 mm graded aggregate as in floor of average 25 mm thick, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil exceeding 500 Metre and not exceeding 1.50 Km depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock, complete all as specified and directed by Engineer-in-Charge.
Material and labour for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed by Engineer-in-Charge.
(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout.
(ii) Rendering of uneven surfaces with 6mm thick Cement Mortar 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by weight of cement consumed including filling it with water to check dampness and seepage and where dampness / seepage is noticed, nozzles shall be fixed and grouting carried out.
(iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sika guard 694 F(I) or equivalent make: in Fosroc / Thremax as approved by GE.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(v) Applying two coats of polymer modified cementious water proof coating with Sika Top seal 107 or or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3 kg/Sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or equivalent make in Fosroc / Thremax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.
(vi) Plaster the bottom and sides upto bottom of the skirting with minimum 20mm thick Cement Mortar 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by weight of cement consumed as per manufacturer's specification including rounding of corners and injuctions sloping towards spout.
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint .
(viii) The sunken floor shall be filled with lean concrete 1:7:12.
Note :- Testing the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all Material & Labour is included in the rates quoted above.
Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where-ever required and to expose rusted reinforcement upto depth not exceeding 50mm and disposal of rubbish off the premises to a distance not exceeding 50 mtrs including cleaning of reinforced concrete surface by air compressor, complete all as specified and directed by Engineer-in-Charge.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg / Sqm / coat, complete all as specified and directed by Engineer-in-Charge.. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar).
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2mm of SikaTop Armatec ®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78, complete all as specified and directed by Engineer-in-Charge. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar)
Material and labour for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur ®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C, complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122˚F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122˚F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete sub strate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material and labour for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Thermax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness not exceeding 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions and directed, complete all as specified and directed by Engineer-in-Charge.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: Sika Rep ® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : Sika Rep ® Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99, complete all as specified and directed by Engineer-in-Charge. Note: 1 Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work .This is not paid seperately. Note: 2 Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc. complete as per site requirement. This is not paid seperately.
Material & labour for Mild CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No. 116 above, but 6mm to 8mm dia., complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No.116 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge.
Material and labour for bird hazardous nylon wire net of 1.5 mm dia and avg aperture of net approx. 50mm including cotton rope of dia 10mm, U bolt clamp of size 30mm, round ring of dia 30 mm, D shackle of 50 mm and including all arrangement for fixing the net., complete all as specified and directed by Engineer-in-Charge. Note: Overlap of net shall be measued separate.
Supply and fixing stainless steel rope of dia 6mm for fixing of nylon wire netting including necessary arrangement etc., complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' INTERNAL ELECTRICAL ITEMS
Taking down carefully copper /aluminium point wiring (light, fan ,socket or power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disribution surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge.
Taking down of unserviceable sub main wiring of any size and including PVC conduit and accessories & removing from site, complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable MCB SPN/SP/TP, Meter box, DB's etc of any capacity, complete all as specified and directed by Engineer-in-Charge.
Taking down Ceiling sealing cable end, dismantling blades and removing fan & blades and deposit to E/M store, complete all as specified and directed by Engineer-in-Charge.
Taking down Geyser of any capacity and deposit to E/M store, complete all as specified and directed by Engineer-in-Charge.
Material & labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc. fixed concealed/ recessed in wall or ceiling etc including 1.5 Sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules complete all as specified and directed by Engineer-in-Charge etc for the following:-
One light/Call bell point controlled by one, one way switch
One fan/Exhaust point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Point wiring complete with 4 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 4 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing modular switch 1 way, 16 Amps, 1 modular (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing modular fan regulator, 120 watt, 2 moduler (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & Fixing Buzzer, Ding dong, AC 230Volts single pole, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Modular Bell push 6A 1 module, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips - Cat Part No- BN100C LED40S-6500 PSU L120 GR or equivalent to Wipro / GE lighting
Supply & Fixing wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips -Cat Part No BN 021 LED12S 6500 PSU GR or equivalent to Wipro / GE Lighting
Supply & Fixing LED 25 Watts (5700K) Bldg Security light fitting, and including with GI Pipe 32 mm dia bracket with connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site, complete all as specified and directed by Engineer-in-Charge. Make: Wipro Cat No LR02-291-XXX-57-XX /Philips /CG
Supply & Fixing BEE five star rated BLDC energy efficient high-speed Metalic body ceiling fan having 1200 mm blade sweep, air-flow not less than 215 CMM, 28W,operating voltage 140-285V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan with smart remot control complete all as specified and directed by Engineer-in-Charge. Make: Orient / Crompton / Usha or equivalent
Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed by Engineer-in-Charge. Note : Cutting of wall of appropriate size of fan and making good in cement 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item.
Supply and fixing exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge. Note : Cutting of wall of appropriate size of fan and making good in cement 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item.
Supply and fixing electric water heater, storage type with inner tank and heating element upto 2 KW capacity 25 litre, BEE 3 star and above rated complete with all accessories such as safety valve, thermostate, NRV, with Anchor fastners of suitable size and including Flexible hot/cold connection Pipe -02 Nos, complete all as specified and directed by Engineer-in-Charge. Make :- Racold Model. Andris Uno 25 / JAQUAR Model. ELENA MANUAL 25 LTR/ AO Smith Model. Finesse./ Havells Cat No GHWAPPTWB025 / Bajaj Majesty or equivalent
Supplying and fixing conventional single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing distribution Board cum Meter box wall mounting type of size 980 X 950 X 330mm (minimum) fabricated from polycarbonate sheet, IP 54 cimpartmentalised design, indoor/wall mounting, Cable gland of suitiable size prewired and comprising of following :- (a) MCCB cap 63 Amps, 4 Pole, 16 KA - 01 No.(In Coming) (b) MCB SP 40 Amp, 10 KA - 05 Nos (Out Going) (c) Terminal for distribution (d) 05 Nos of cubicals for housing single phase meter (e) 06-32Amp SP MCBs-02. Make:- Hensel / Hager / Universal
Material & Labour for sub main wiring with two single core 2 x 6 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and directed by Engineer-in-Charge. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Supply & fixing Sheet metal enclosure (factory made) double door for distribution board (when MCB's are to be used) Single pole neutral 240 V, 12 ways with 200 Amp rated busbar connectin with suitable size of thimbles,complete all as specified and directed by Engineer-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Modular Motor starter 16A capacity, 02 Module with metal flush box, cover plate of required module for Acs, complete all as specified and directed by Engineer-in-Charge. Make:- Legrand Cat No 6811 66C&S/Anchor or equivalent
Supply & Fixing Co-axial TV socket, One Module, complete all as specified and directed by Engineer-in-Charge. Make:- Legrand Cat No 5748 51 or equivalent
Supply & Fixing double RJ-11 telephone socket (Jack type) with shutter, One Module, complete all as specified and directed by Engineer-in-Charge. Make:- Legrand Cat No 5734 27 or equivalent
Supply& Fixing rigid non metallic 25mm dia PVC conduit exclusive of boxes (Junction/terminal) but inclusive of all Tee, bends, elbow reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing junction boxes (1 to 4 way) with cover plates and accessories, complete all as specified and directed by Engineer-in-Charge.
Material & labour for cutting chases, pinning in, making good to facings where required of brick/stone wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed by Engineer-in-Charge.
Material & labour for Earthing complete with GI earth plate 60cm x 60cm x 6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and including earth work, PCC pit and RCC cover, watering pipe 20 mm dia light grade, funnel, wire mesh, protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc. and connected to earthing test point, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32 x 6mm as earthing lead with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40 x 3mm GI flat, PCC pit of required size in PCC 1:2:4 type B-1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm medium grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel and directed as shown in electrical plate No 3 of SSR Part-I 2009, complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' EXTERNAL ELECTRICAL ITEMS
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 35 Sqmm 3.5 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc., all connections, complete all as specified and directed by Engineer-in-Charge. Make : Polycab / Havells/ RR Kabel
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply & Fixing of GI steel tubing light grade 80mm dia for laying in ground and road crossing along the pole in coping etc. for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc., complete all as specified and directed by Engineer-in-Charge. Make - Tata/Jindal/Surya Prakash
Supply and laying 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches / road / drain or fixed along wall, poles or laid under floor, complete all as specified and directed by Engineer-in-Charge. Make : Rex / Poly/ Gemini
Material & Labour for cutting existing road/hard standing not exceeding 45cm x 45cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil, complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' EXTERNAL WATER SUPPLY ITEMS
Taking up cast iron water mains (inlcuding all fitting, with spigot and socket ends and lead joints including burning out joints of any size, complete all as specified and directed by Engineer-in-Charge.
Material & labour for cutting the 100mm bore CI/DI pipes and reducing the required length before laying for inserting of new CI specials such as Tees/ Reducers / Tail pieces /collers /sluice valve /Air release valve etc., complete all as specified and directed by Engineer-in-Charge.
Material & labour for cutting the 50mm bore CPVC pipes and reducing the required length before laying for inserting of new CI specials such as Tees / Reducers /Tail pieces /collers /sluice valve /Air release valve etc. complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC pipes of following size SDR 11 & Plain CPVC SDR 11 fittings in trenches & fitting on walls, celing or floors, complete all as specified and directed by Engineer-in-Charge.
50mm dia
32mm dia
Supply & fixing CPVC ball valve of following size complete all as specified and directed by Engineer-in-Charge.
50mm dia
32mm dia
Material & labour for construction of brick masonary valve pit complete including necessary excavation and earth work complete all as specified with internal dimension 60cm x 60cm x 60cm (type 'B') including MS sheet cover 3mm thick welded with hinges on angle iron frame 50mm x 50mm x 6mm with hold fast grouted in 100mm thick PCC (1:2:4) type B-1 coping on top of brick wall including necessary locking arrangement, complete all as specified and directed by Engineer-in-Charge.
vijay infraprojects pvt ltd
K K Construction Co
SANVI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .