Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹17.7 L+₹1.1 L (6.51%)Rejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹18.0 L+₹1.4 L (8.39%)Rejected-Finance VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹20.0 L+₹3.4 L (20.4%)Rejected-Finance 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹20.2 L+₹3.6 L (21.5%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Jun 2024, 6:00 pmClosed
Lt Col Shilpam Bharali
Garrison Engineer (AF) Military Engineer Services, Bareilly 243002 (UP)
8796 REPAIR, MAINT OF INTERNAL WIRING, FIXTURES, DBs ETC. ALONG WITH CONNECTED ITEMS IN OFFICERS LIVING AREA, SMQ, VARIOUS MESSES AND SINGLE LIVING ACCN AT AF STN, BAREILLY
2024_MES_655316_1
8796/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
Class D
Category b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Bareilly
₹60,000
Yes
29 Jun 2024
21 May 2024
19 Jun 2024
21 May 2024
17 Jun 2024
5 Jun 2024
Amount
Taking down carefully aluminum/ copper point wiring for light, fan, socket or power point etc. complete including conduit, fittings and fixtures such as ceiling rose, switch socket, pendants etc. including making good surface of wall, ceiling etc. complete all as specified.
Taking down carefully aluminum/ copper sub main wiring complete including conduit and conduit accessories all as specified.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one light/ fan/ bell point controlled by one switch 6 Amps 1 way. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
All as per Item No. 3 herein before but for one 3 pin 6 Amp socket out let point on independent board.
All as per Item No. 3 herein before but for one 3 pin 6 Amp socket out let point on same board with other switches.
All as per item No. 3 herein before but point wiring with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) duly earthed with same cable as for wiring above but green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through existing rigid non-metallic PVC conduit, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one light/ fan/ bell point controlled by one switch 6 Amps 1 way.
All as per Item No. 7 herein before but for one 3 pin 6 Amp socket out let point on independent board.
All as per Item No. 7 herein before but for one 3 pin 6 Amp socket out let point on same board with other switches.
All as per item No. 7 herein before but point wiring with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) duly earthed with same cable as for wiring above but green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC concealed conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including decorative modular cover plates (inner and outer) suitable for housing modular pattern switches/ sockets/ regulators etc. along with necessary metal boxes flush mounting in the wall duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one light/ fan/ bell point controlled by one switch 6 Amps 1 way. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
All as per Item No. 11 herein before but for one 3 pin 6 Amp socket out let point on independent board.
All as per Item No. 11 herein before but for one 3 pin 6 Amp socket out let point on same board with other switches.
All as per item No. 11 herein before but point wiring with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) duly earthed with same cable as for wiring above but green in colour as continuous earthing wire suitable for one 3 pin 16 Amps socket out let on independent board.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 Volts grade (ZHFR) Zero Halogen Flame Retardant Smoke Free Non-Toxic Non-Corrosive Electric Cable with multi stranded copper conductor of size 1.5 Sq.mm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduit fittings and accessories such as tees, junction boxes, bends, duly tested by CMRI Dhanbad, duly earthed with same cable as for wiring above but green in colour as continuous earthing wire connected to earth dolly complete all as specified and directed by Engineer-in-Charge for one light/ fan point controlled by one flame proof rotary switch SP one way.
All as per Item No. 15 herein before but for one 3 pin 6 Amp socket out let point on independent board.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 Volts grade (ZHFR) Zero Halogen Flame Retardant Smoke Free Non-Toxic Non-Corrosive Electric Cable with multi stranded copper conductor of size 2.5 Sq.mm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduit fittings and accessories such as tees, junction boxes, bends, duly tested by CMRI Dhanbad, duly earthed with same cable as for wiring above but green in colour as continuous earthing wire connected to earth dolly complete all as specified and directed by Engineer-in-Charge for one 3 pin 15/ 25 Amps socket outlet point on independent board
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 Amp, 250V, 2P + earth complete all as specified and directed including taking down existing unserviceable socket. [Make:- Sudhir/ Baliga/ Shyam/ Bajaj].
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25 Amp, 250V, 2P + earth complete all as specified and directed including taking down existing unserviceable socket. [Make:- Sudhir/ Baliga/ Shyam/ Bajaj].
S&F Flame proof, weather proof direct entry type rotary switch with cable terminal box in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230 volts 16 Amp ON / OFF switch AC certified by CRMI for group II-A & II-B including compression glands complete all as specified and directed including taking down existing unserviceable switch. [Make:- Sudhir/ Baliga/ Shyam/ Bajaj].
S&F wall/ surface mounted type LED light fitting 1 X 20 watt (4' long) with extruded aluminum batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible three core 1.50 sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed including taking down existing unserviceable light fitting. [Cat. Part No. BN021C LED22S PSU CW GR (SmartBright) of make: Philips or Cat No. ENDURALINEARNEOBS20WLED865SPCWH of make: Havells/ Cat No. CCS-100-20-65-HL2-DP-NWH of make: CG/ Cat No. LL20-221-XXX-65NE3 of make: Wipro]
S&F wall/ surface mounted type LED light fitting 1 X 9 to 12 watt (2' long) with extruded aluminum batten with multiple lumen packages complete with all accessories internally pre-wired and including making electric connection with flexible three core 1.50 sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and directed including taking down existing unserviceable light fitting. [Cat. Part No. BN 021 LED12S 6500 PSU GR (SmartBright) of make: Philips or Cat No. ENDURALINEARNEOBS10WLED865SPCWH of make: Havells/ Cat No. LL20-111-XXX-65NE3 of make: Wipro]
S&F Wall / surface mounted type LED light fitting batten type complete with LED lamp 05 Watt (1 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable complete all as specified and as directed. Make :- Philips, Wipro, Havells
S&F recess mounted direct lighting LED Luminaire 34-36W of size 2'x2', with powder coated CRCA housing, seamless front frame, flat white high transmission acrylic cover fixed to Modular/ Gypsum/ POP ceiling complete including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to fitting all as directed. [Cat No. PLUTONEO2X2PLR34WLED857S of make: Havells or Cat No. RC380B LED36S-6500 G5 L60W60 PSU OD of make: Philips or Cat No. LCTLRNE-36-FO-CDL of make: CG/ Cat No. CRCO10S038HP57GL of make Wipro with frame of Cat No. 9180P01089 LP]
S&F Recess mounted LED down lighter 18 to 20 Watt in powder coated/ aluminum die cast housing with integrated electronic driver complete including connecting up with three core twisted flexible copper conductor cable of suitable size all as directed including taking down existing unserviceable light fitting. [Cat No. GLOWDLR18WLED857S of make: Havells or Cat No. DN296B LED20S-6500 PSU WH of make: Philips or Cat No. BZSLO nxt 18L LED WH SD of make: Bajaj]
S&F Surface mounted LED down lighter 18 to 20 Watt in powder coated/ aluminum die cast housing with integrated electronic driver complete including connecting up with three core twisted flexible copper conductor cable of suitable size all as directed including taking down existing unserviceable light fitting. [Cat No. ENDURANEOHESURFA CEDLS21WLED857S of make: Havells or Cat No. SM251C LED20S- 6500 PSU WH of make: Philips or Cat No. BZSLOS NXT 18L LED WH SD of make: Bajaj]
S&F LED bulk head light fitting 10W with IP-65 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to fitting and taking down existing unserviceable luminaire all as directed by Engineer-in-Charge. [Cat No. 'LBHP-10-CDL' of make: CG/ 'BIBWP 10W LED' of make: Bajaj]
S&F energy efficient building security light fitting not less than 35W, with pressure die cast aluminum housing, heat resistant glass, IP-65 consisting of high power LED, control driver etc. along with necessary cable connection with 3 Core 2.5 sq.mm copper cable, including 40mm dia GI pipe bracket, bolts, nuts etc. fixed to walls complete all as specified and as directed including taking down existing unserviceable light fitting. [Cat No. LSTS-36-CDL-M of make: CG or Cat No. BRP046 LED 36 CW MR S1 PSU GR of make: Philips or Cat No. ENDURAPEARLNEOSL40W LED757 PASYTOPC of make: Havells/ Cat No. LR13-501-XXX-57-XX of make Wipro]
Supply and install integral LED aviation obstruction light 12W comprising of aluminum housing with polycarbonate enclosure, 302 nos. LEDs complete including necessary fixing arrangement, installed on top of hangars/ OH tanks etc. all as directed including taking down existing unserviceable light fitting. [Cat No. BGAV 302 LED of make: Bajaj or equivalent in Future Lighting Solutions (P) Ltd Nagpur/ Siren & Electricals, Chennai]
Supply and install LED post top lantern with spun aluminum housing with opal acrylic diffuser, 40-45W, IP 65 protection complete including necessary cable connection all as specified and as directed including taking down existing unserviceable fitting. [Cat No. CORALPT45WLED757PSYMTOPC of Make: Havells or Cat No. BGCTNP 40W LED WH of Make: Bajaj or Cat No. LP07-501-XXX-57-CL of Wipro].
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230V AC all as specified.
S&F switch piano, flush type, single pole, two way, 5/6 Amps, 230V AC all as specified.
S&F Bell push, flush type, single pole, 5/6 Amps, 230V AC all as specified.
S&F socket outlet 6 Amp, 2 in 1, 5 pin, 230V AC
S&F socket outlet 6/16 Amp, 2 in 1, 6 pin, 230 V AC
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230V AC all as specified.
S&F ceiling rose PVC/ Poly carbonate isolated body, three terminal, 230 Volts AC complete all as specified.
S&F fan regulator electronic socket step type, 100 Watts, 230 Volts, flush type all as specified.
S&F Electric bell 230 Volts AC. [Make: Anchor/ Leader/ Cona]
M&L for Angle Holder, insulated body with back plate with & including LED Lamp 9 Watt suitable for batten fittings complete all as specified and directed by Engr-in-Charge. [Make: Anchor/ Leader/ Cona]
S&F modular snap switch 6 Amp one way 230 V AC, one module [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
S&F modular socket outlet 6 Amp multi pin socket for all pins 230 V AC, two modules [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
S&F modular snap switch 16 Amp one way 230 V AC, two modules [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
S&F modular socket outlet combination 16 Amp and 6 Amp heavy duty 230 V AC, two modules [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
S&F modular type fan regulator electronic socket step type 120 W, two modules complete all as specified. [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
S&F modular bell push 6 Amp one way 230 V AC, one module [Make: Roma (Anchor)/ Crabtree (Havells)/ Legrand]
M&L for street light bracket made of GI pipe medium grade 32mm dia, approx 1.20 m long bent to shape suitable for fixing street light fixed to pole with 2 Nos of MS FI brackets with nuts and bolts complete including painting with two coats of aluminium paint over a coat of zinc chrome primer all as specified and as directed
M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 2.5 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 4 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 20mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 4 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 6 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
M&L for sub main wiring concealed complete with two runs of 1100 Volts grade 10 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. with one run of 1100 Volts grade 10 sq.mm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as earth continuity conductor all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F sheet steel powder coated distribution board Vertical type TPN 8 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB up to 160 Amps as incomer and MCBs as out going complete including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Cat No. 5077 47 of make Legrand/ Cat No. DBVTH008DD of Make: L&T]
S&F sheet steel powder coated distribution board Vertical type TPN 6 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB up to 160 Amps as incomer and MCBs as out going complete including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Cat No. 5077 46 of make Legrand/ Cat No. DBVTH006DD of Make: L&T]
S&F sheet steel powder coated distribution board Vertical type TPN 4 ways, 415 volts, with 200 Amps rated copper bus bar, neutral link, earth bar, IP 43 protection and double door, suitable for mounting MCCB up to 160 Amps as incomer and MCBs as out going complete including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Cat No. 5077 45 of make Legrand/ Cat No. DBVTH004DD of Make: L&T]
S&F in repairs MCCB 4 pole, 125 Amps, 16 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed. [Make: Legrand/ L&T/ Schneider/ ABB]
S&F in repairs MCCB 4 pole, 100 Amps, 16 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed. [Make: Legrand/ L&T/ Schneider/ ABB]
S&F in repairs MCCB 4 pole, 160 Amps, 16 KA, 415 Volts with thermal magnetic release connecting up with necessary spreader links complete all as directed. [Make: Legrand/ L&T/ Schneider/ ABB]
S&F sheet steel powder coated distribution board TPN 4 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F sheet steel powder coated distribution board SPN 12 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, double door with IP 43 protection, suitable for mounting MCBs all as specified and as directed including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F MCB TPN 40 to 63 Amp, 10 KA, 'C' curve, 415 V AC. [Make: Legrand/ L&T/ Schneider/ ABB]
S&F MCB SPN, 240 volts, 40 to 63 Amps, 'C' curve, 10 KA all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F MCB SP, 240 volts, 6 to 32 Amps, 'C' curve, 10 KA all as specified and as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F in repairs single pole and neutral sheet metal enclosure with two pin and earth plug and socket with one single pole MCB 20 Amps 240 Volts complete all as directed. [Make: L&T/ Schneider/ Legrand/ ABB]
S&F die cast aluminium LED Flood light not less than 70W IP 66 with high power LEDs, integral flood light with driver inside a PDC housing including all fittings, clamps, angle frame etc for fixing on wall/ pole etc with all accessories pre-wired including taking down existing unserviceable fitting complete all as specified and directed [Make: Cat Part No. JETAALBAFLOODLIGHT70W of make Havells or LF19-931-060-57-XX of make: Wipro or BVP120 LED 70 CW FG S1 PSU GR of make: Philips].
S&F suspended/ surface type High bay luminaire not less than 150 Watt, environmental friendly, energy saving long life corrosion resistant suspended/ vertical surface mounting pressure die-cast aluminium housing and control gear with high power LED with all mounting accessories for fixing to truss of hangar/ MT garage etc complete prewired with flexible 3 core 1.50sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete including taking down existing unserviceable light fitting all as specified and as directed. [Model: SAUCERGENXADVHBP150WLED857PWBBORL of make: Havells or BY718P LED150/CW PSU NB IN of make Philips or LH21-262-060-57-XX of make: Wipro]
S&F of LED street light fitting 70W, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66 with high power LEDs and unique peanut lens to ensure uniform light distribution complete with all accessories pre-wired including taking down existing unserviceable fitting complete all as specified and directed. [Cat. Part No. BRP409 LED 074 CW HO MR FG S1 PSU GR of Philips or ENDURACITYLINERNEO SL70WLED757 PASYBOTG (ENDURA CITYLINER NEO) of Havells or LR02-671-XXX-57-G2 (Skyline) of Wipro]
Supply and laying XLPE insulated armoured heavy duty electric cable of size 3½ core 35sq.mm with aluminum conductor 1100 Volts grade, ISI marked as per IS 7098-I, fixed to walls with necessary porcelain insulators and saddles etc. complete including taking down existing burnt cable all as specified.
Supply and laying XLPE insulated armoured heavy duty electric cable of size 4 core 25sq.mm with aluminum conductor 1100 Volts grade, ISI marked as per IS 7098-I, fixed to walls with necessary porcelain insulators and saddles etc. complete including taking down existing burnt cable all as specified.
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25cm in any type of soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
Supply and spread dry sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge.
Horizontal Boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes up to 50mm bore and making good the disturbed surface complete all as specified and as directed. [Note: GI pipe will be measured and paid separately]
S&F GI pipe light grade with all fittings 50mm dia for cable protection.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of earth plate not less than 1.50m below normal ground level, connected to galvanized earth lead 4mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board/ main DB’s/ earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate 150 mm in all directions with & including watering pipe 20mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick precast RCC cover of size 450 mm X 450mm with 1:2:4, type B-1 duly reinforced with 8mm dia TMT steel bars @ 150mm c/c both ways with suitable lifting handle made of 10mm dia mild steel round bars to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15mm bore including testing on completion of job complete all as specified and directed.
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16 of tender document i.e. Rs. 82,780.00
S S ELECTRICALS
M/S MAHIRA ENTERPRISES
SONI ENTERPRISES
M/S BABA ENTERPRISES
avon electric engineering woks
M/s Agarwal Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .