Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),Dehradun
Work of Complete overhauling /Maintenance works of 33/11 KV VCB and SF6 Breaker of different make for one year installed at various 33/11 KV Substation Kunj Bhawan, Landor, Karykuli and Happy Velly under EDSD Mussoorie.
2024_UPCL4_75470_1
Tender No.09/EDC(U)/2024-25
Open Tender
Electrical Works
Item Rate
180 days
as per tender specification
As per tender specification
4 documents required · 4 mandatory
₹2,360
Executive Engineer,ElectricityTest Divsion(U),DDN
₹61,000
26 Nov 2024
9 Sept 2024
23 Sept 2024
10 Sept 2024
23 Sept 2024
11 Sept 2024
Amount
Decentralized Material
11 KV Indoor VCB/SF6
Indicator 220 VAC (Colour as per required)
Trippping coil O/C 1A, AC DC
Trippping coil E/F 2.5 A, AC DC
Auxilary Switch
IDMT Relay 24 V DC Aux 250 VAC/DC
Miscellaneous item as per annexure A
Operating Mechanism Assembly
Tulip Contact 1250 A
Vacume Interrupter
Upper Bracket Terminal
Lower Bracket Terminal
Interrupter Housing
32 Pin Recatangular HDC Connector Assembly
Easun Reyrolle IDMT E/M Releay Housing
11 KV PT Bus Bar Female Contact
220 Volt 100 W Pannel Heater
D/P MCCB O6A
33 KV Indoor VCB/SF6
240 Volt Charging Motor
Auxilary Switch
Closing Coil (24 Volt) for CG Breaker
Tripping Coil (24 Volt) for CG Breaker
Labour Charges (Repairing and Overhauling of 11 KV Indoor Pannel/33 KV Breaker)
Overhauling and maintenace alignment mechanism of 11 KV VCB for smooth operation including replacement of all rusted/ deform N& B, removing old lubrication, cleaning of all moving part and fresh H.Q. Lubrication.
Overhauling and maintenance alignment mechanism of 33 KV SF6/VCB for smooth operation including replacement of all rusted/deform N&B, removing old lubrication, cleaning of all moving parts & fresh H.Q. Lubrication.
Repairing/Fixing of 11 KV VCB mechanism regarding operation along with the setting allignment of truck assembly of VCB with replacement of required minor part ie. Wheel/wasjer/Spindle /Square spigot/ switchgear housing tray etc.
Maintenance of operation of 11 KV VCB mechanism ie tripping spring and closing sprining charging assembly/Auxilary switch assembly with replacement of required parts and N&B complete and fixing of operational counter of VCB.
Maintenance of operation of 33 KV VCB/SF6 mechanism ie tripping spring and closing sprining charging assembly/Auxilary switch assembly with replacement of required parts and N&B complete and fixing of operational counter of VCB/SF6.
Replacement of damage wiring of existing heater/AC CKt with new one with required cabling work with proper ferruling.
Replacement of faulty relay with new one.
Replacement of HV contact point of 11 KV VCB
Repairing of Female contract point of 11 KV VCB
Repairing of male Contact of 11 KV VCB
Replacement of tulip contact of 11 KV VCB
Maintenance and repairing of spout of 11 KV VCB
Tightning of all Bus Bars connection after cleaning of Bus Bar Chamber.
Proper sealing of Bus Bar Chamber/VCB pannel and applying of sealent after tightning of pannels N& B on top and back plate of pannels.
Replacement of interrupter Housing
Fixing of female bus bar contract and proper allignment with PT connecting ROD.
Cleaning of Inner Chamber of incomming pannels with solvent etcand painting with powder coating.
Repairing of damaged 24 Volt Battery Charger
Carrying out comprehensive test and tripping check of wiring of different incoming and outgoing feeder installed at various 33/11 KV S/s such as wiring of CT to feeder panel, upto relay, Auxialiary switch to trip coil in the trolley side by both simulating load at primary of CT and by simulating trip current by relay and thereby locating the specific main fuctioning of Panel ( All testing result should be provided by certified testing agency in prescribed format given by Test Divsion).
Annual Maintenance start after one year of above work (06 Month peridocaly) of 33/11 KV VCB/SF6 as SOP prescribed by manufacturer by skilled technician(Material if need to replced during maintenance provided by UPCL)
M/s S S ENTERPRISES (BID ID -335409)
Shekwal Power Space (BID ID -335395)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .