Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC CHATHANADU HOUSE CHEMBUMUKKU | L1 | Accepted-AOC Agreement executed vide agreement no.287/25-26 | |
| 2 | L2₹1.3 L+₹17,632 (15.9%)Rejected-Finance KARAKKATTIL CHENGARA PATTIMATTOM PO LSGD THRIKKAKARA MUNICIPALITY ERNAKULAM DISTRICT KERALA | THRISSUR | KERALA | 680667 | L2 | Rejected-Finance Agreement executed by L1,hence L2 is rejected |
| Sl No | Description | Qty | Unit | AKHIL SAJEEVAN L1 | AJAS K P L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | 90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point | 16 | point | 800 ₹12,800 Lowest | 1,000 ₹16,000 |
| 1.00 | 90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 1 | point | 979 ₹979 | 900 ₹900 Lowest |
| 1.00 | 90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | 6 | point | 850 ₹5,100 Lowest | 1,450 ₹8,700 |
| 1.00 | 90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 3 | each | 524 ₹1,572 | 500 ₹1,500 Lowest |
| 1.00 | 90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | 1 | each | 699 ₹699 | 550 ₹550 Lowest |
| 1.01 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture | 4 | each | 999 ₹3,996 Lowest | 1,200 ₹4,800 |
| 1.01 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 1 | each | 150 ₹150 | 120 ₹120 Lowest |
| 1.01 | OD56695/2025-2026:Supply and providing 7 W/ 9 W LED bulb in the existing light fitting as required. | 1 | each | 127 ₹127 | 110 ₹110 Lowest |
| 1.01 | OD56728/2025-2026:Supply and provide 20 W LED flood light ( model No. LFL 20 - Luker or equalant make ) | 9 | each | 1,500 ₹13,500 Lowest | 3,300 ₹29,700 |
Tender Value
₹1.4 L
EMD Value
₹3,423
Closing Date
20 Aug 2025, 6:00 pmClosed
THE ASSISTANT EXECUTIVE ENGINEER
O/o THE ASSISTANT EXECUTIVE ENGINEER,THRIKKAKARA MUNICIPALITY
hrikkakara- Electrification of open Stage at NGO Qtrs.- Electrification of open Stage at NGO Qtrs under Thrikkakara Municipality.-General Electrical Work
2025_LSGD_784982_7
LIDEW/AEE/ET/28/2025
Open Tender
Electrical Works
Item Rate
15 days
THRIKKAKARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
₹3,423
Yes
18 Nov 2025
12 Aug 2025
22 Aug 2025
12 Aug 2025
20 Aug 2025
12 Aug 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1289894.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .