Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.3 CrAccepted-AOC WARD NO 01 PUNJABI COLONY GADARPUR U S NAGAR | LUDHIANA | PUNJAB | 141001 | ₹1.3 Cr | L-1 | Accepted-AOC Work awarded |
| 2 | L-2₹1.3 CrRejected-Finance WARD NO 04 SUNHARI KICHHA U S NAGAR | CHAMOLI | UTTARAKHAND | 246401 | ₹1.3 Cr | L-2 | Rejected-Finance Due to Higher Rate |
| 3 | L-3₹1.3 CrRejected-Finance NEAR EAST WEST PUBLIC SCHOOL SHAHABAD GATE RAMPUR U P | ₹1.3 Cr | L-3 | Rejected-Finance Due to Higher Rate |
| Sl No | Description | Qty | Unit | TNK Electricals L3 | MANRAJ ELECTRICAL & INFRASTRUCTURE L2 | HIMALAYA BUILDCON L1 |
|---|---|---|---|---|---|---|
| 1.00Annexure-A (LABOUR CHARGES) | ||||||
| 1.01 | Laying of barbed wire as per direction of Engineer in Charge. | 0.11 | Cum | 460 ₹50.60 | 459 ₹50.49 | 449.78 ₹49.48 |
| 1.02 | Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual. | 30 | Nos. | 407.52 ₹12,225.60 | 410 ₹12,300 | 399.9 ₹11,997 |
| 1.03 | Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing. | 643 | Kg. | 29 ₹18,647 | 26.35 ₹16,943.05 | 20.75 ₹13,342.25 |
| 1.04 | Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work. | 8.8 | CBM | 230 ₹2,024 | 233 ₹2,050.40 | 226.9 ₹1,996.72 |
| 1.05 | Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/manual in 11 KV Line. | 20 | Nos. | 465 ₹9,300 | 454 ₹9,080 | 448.95 ₹8,979 |
| 1.06 | Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual. | 2.16 | CBM | 5,512 ₹11,905.92 | 5,509 ₹11,899.44 | 5,499.75 ₹11,879.46 |
| 1.07 | Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work. | 7.84 | CBM | 249 ₹1,952.16 | 246.5 ₹1,932.56 | 239.65 ₹1,878.86 |
| 1.08 | Erection of SP-55 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual | 8 | Nos | 1,325 ₹10,600 | 1,309.5 ₹10,476 | 1,299.9 ₹10,399.20 |
| 1.09 | Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement, stone and sand etc. | 51 | Nos. | 609 ₹31,059 | 618 ₹31,518 | 599.25 ₹30,561.75 |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
3 Feb 2026, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle, Rudrapur
Replacement of ACSR Dog bare conductor by Insulated Covered Conductor (AAAC) in 11 KV Lalpur-III(Industry) Feeder emanating from 33/11 KV S/s Lalpur under EDD, Kichha
2026_UPCL3_91018_1
EDC(USN)53/2025-26
Open Tender
Electrical Works
90 days
Lalpur
Please refer tender documents
4 documents required · 4 mandatory
₹11,800
EE ETD Rudrapur
₹2.6 L
3 Jun 2026
16 Jan 2026
4 Feb 2026
16 Jan 2026
3 Feb 2026
17 Jan 2026
Annexure-A (LABOUR CHARGES)
Laying of barbed wire as per direction of Engineer in Charge.
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod to proper depth and connecting the earth electrode with the help of G.I. wire as per construction manual.
Fabrication of MS Channel angle iron etc in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESPO schedule and local approved drawing.
Excavation of earth for stay pit of size 0.6x0.6x1.2 mtr in all types of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Fixing, tightening and nozzling of stay with pole and stay rod on required tension as per drawing/manual in 11 KV Line.
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement, sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual.
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all types of soil including proper dressing of sides and ramming of bottom including etting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Erection of SP-55 single support pole in proper level and alignment along with fixing of all accessories like top channel & clamps as per RESPO manual
Muffing of poles size 0.45x0.60 cm radius with 1:3:6(1 cement:3 coarse sand :graded stone 10 mm nominal size) block size 45 cm height from ground level including cost of cement, stone and sand etc.
Dismantling of existing HT line including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections and Street light connections etc. including rolling of conductor and cartage back from site to JE store (ACSR Dog)
Painting of SP-55 pole with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
Mounting & Fixing of Fuse sets on double pole structures including making of connections complete work
T-off Connection Complete 11 KV line.
Cartage of ST pole SP-55 Poles from store centre to construction site with loading, unloading at both points and proper stacking.(Distance 21-50 Km)
Cartage of other material (other than poles) by vehicle from Store Center to nearest construction site Store including loading and unloading at both ends(distance 21-50 Km).
Headload cartage of ST Pole SP-55 from road to site (distance 0-1 Km)
Headload cartage of small material (distance 0-1 Km).
Straightning of Tilted STP Poles as per direction of Engineer in Charge.
Laying G.I. Earth wire 7/16 SWG for providing Earth Wire on 11 KV Line as per direction of Engineer in Charge.
Fixing of IPC with AL. Bail for Earthing as per direction of Engineer in Charge.
Removing Heavy Tree Branches from line as per direction of Engineer in Charge.
Fixing of 11 KV 90KN Tension Clamp B&IPC as per direction of Engineer in Charge.
Fixing of 11 KV Suspension Ties as per direction of Engineer in Charge.
Fixing of 11 KV IPC for CC to CC Conductor as per direction of Engineer in Charge.
Fixing of 11 KV IPC for CC to Bare Conductor as per direction of Engineer in Charge.
Fixing of 11 KV Mid Span Jointing Kit as per direction of Engineer in Charge.
Opening of 11 KV Jumper and Making again of section pole.
Renozzeling of existing stay set as per direction of Engineer in Charge.
Laying Spreading, Stringing AAAC Conductor as per direction of Engineer in Charge.
Back Carriage of Scrap material as per direction of Engineer in charge.
Lopping and chopping of trees branches near HT, LT line as per direcetion of Engineer in Charge.
Annexure-B (SUPPLY ITEMS)(As per UPCL Norms)
Supply of MS NUT & BOLT Off size.
Supply of Holding Clamp for SP-55 with N/B.
Supply of F-Clamp.
Supply of Earth wire Clamp for SP-55 with N&B.
Supply of Stay Clamp for SP-55 with Nut & Bolt.
Supply of 11 KV Cable Ties for Pin Insulator
Supply of 11 KV IPC for Covered to Covered Conductor.
Supply of 11 KV IPC for Covered to Bare Conductor.
Supply of 11 KV mid span Jointing Kit
Supply of IPC with Al. BAIL for Earthing 11 KV
Supply of 11 KV AAAC Covered Conductor AL-59, 99 Sq.mm.
Supply of Al.Lug 120 Sq.mm
Supply of Barbed Wire
Supply of 11 KV Tension Clamp with BAIL & IPC
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
TN532526tenderdocument.pdf
Tender Documents • 1.48 MB
FormAandB.pdf
Other Document • 0.67 MB
GeneralInstruction532526.pdf
Other Document • 0.78 MB
TechnicalSpecificationanddrawing532526.pdf
Additional Documents • 8.29 MB
BOQ_107836.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid