| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.7 LAccepted-AOC KATTUPADATH H AZHEEKAL P O VYPEEN KOCHI ERNAKULAM DIST KERALA 682 508 | KOCHI | ERNAKULAM | KERALA | 682508 | ₹40.7 L Quoted ₹41.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹44.9 LRejected-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹44.9 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | WELTRONENGINEERINGSERVICES L2 | MS BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | Maintenance, service and repair of cranes of any type (EOT/ HOT) with or without electric motor, long traverse, hoist creep, control panels, protective panels, gear box, gantry rails, main switches, resistance coil wire rope, rope drum, brake control cable, limit switches, lift hook, pendent and push buttons and switches etc. of monorail, crane 0.5 Ton capacity of make: Cranex India Ltd = 2 Nos, complete as specified and as directed. | 11 | Job per month | 3,000 ₹33,000 | 3,000 ₹33,000 |
| 2.00 | All as per item No. 1.00 here-in-before but EOT/ HOT crane 1-ton capacity Make: Cranex India Ltd - 2Nos | 11 | Job per month | 3,000 ₹33,000 | 3,500 ₹38,500 |
| 3.00 | All as per item No. 1.00 here-in-before but EOT/ HOT crane 2-ton capacity - 8 Nos
(Make:Cranex India = 04 No,Indef cranes = 02 Nos, Electro mech = 01 No & Life Tech Eqpt Ltd - 01 No) | 11 | Job per month | 3,500 ₹38,500 | 4,000 ₹44,000 |
| 4.00 | All as per item No. 1.00 here-in-before but EOT/HOT, 3 ton capacity Make : Indef cranes/Baby and Morries Engg - 1 Nos | 11 | Job per month | 4,000 ₹44,000 | 4,000 ₹44,000 |
| 5.00 | All as per item No. 1.00 here-in-before but EOT/ HOT crane 4 ton capacity Make : Cranex India Ltd - 1 No | 11 | Job per month | 4,000 ₹44,000 | 4,500 ₹49,500 |
| 6.00 | All as per item No. 1.00 here-in-before but EOT crane 5 ton capacity Make : Cranex India Ltd - 1 No | 11 | Job per month | 4,000 ₹44,000 | 5,000 ₹55,000 |
| 7.00 | All as per item No. 1.00 here-in-before but EOT/ HOT crane 6 ton capacity Make : Cranex India Ltd - 01 No | 11 | Job per month | 4,000 ₹44,000 | 5,500 ₹60,500 |
| 8.00 | All as per item No. 1.00 here-in-before but EOT crane 7.5 ton capacity Make : Hercules Hoist Ltd - 01 No | 11 | Job per month | 4,000 ₹44,000 | 5,500 ₹60,500 |
| 9.00 | All as per item No. 1.00 here-in-before but EOT crane 10 ton capacity Make : M/S Pioneer cranes - 01 No | 11 | Job per month | 4,500 ₹49,500 | 6,000 ₹66,000 |
| 10.00 | All as per item No. 1.00 here-in-before but EOT crane 12.5-ton capacity Make: M/S Braithwaite - 01 No | 11 | Job per month | 5,000 ₹55,000 | 6,500 ₹71,500 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹99,640
Closing Date
19 Nov 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR/MAINT OF DIFFERENT TYPES OF CRANES AND CONNECTED ELECTRICAL WORKS AND UPS AT KATARIBAGH AND NAVAL BASE KOCHI AND PERIODICAL MAINT OF SOLAR AND AMR SYSTEM INSTALLED AT NAVAL BASE KOCHI
2025_MES_735222_1
8579/E8
Open Tender
Electrical and Maintenance Works
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹99,640
Yes
12 Feb 2026
15 Oct 2025
22 Nov 2025
15 Oct 2025
19 Nov 2025
30 Oct 2025
15 Oct 2025 - 16 Oct 2025
Amount
Maintenance, service and repair of cranes of any type (EOT/ HOT) with or without electric motor, long traverse, hoist creep, control panels, protective panels, gear box, gantry rails, main switches, resistance coil wire rope, rope drum, brake control cable, limit switches, lift hook, pendent and push buttons and switches etc. of monorail, crane 0.5 Ton capacity of make: Cranex India Ltd = 2 Nos, complete as specified and as directed.
All as per item No. 1.00 here-in-before but EOT/ HOT crane 1-ton capacity Make: Cranex India Ltd - 2Nos
All as per item No. 1.00 here-in-before but EOT/ HOT crane 2-ton capacity - 8 Nos (Make:Cranex India = 04 No,Indef cranes = 02 Nos, Electro mech = 01 No & Life Tech Eqpt Ltd - 01 No)
All as per item No. 1.00 here-in-before but EOT/HOT, 3 ton capacity Make : Indef cranes/Baby and Morries Engg - 1 Nos
All as per item No. 1.00 here-in-before but EOT/ HOT crane 4 ton capacity Make : Cranex India Ltd - 1 No
All as per item No. 1.00 here-in-before but EOT crane 5 ton capacity Make : Cranex India Ltd - 1 No
All as per item No. 1.00 here-in-before but EOT/ HOT crane 6 ton capacity Make : Cranex India Ltd - 01 No
All as per item No. 1.00 here-in-before but EOT crane 7.5 ton capacity Make : Hercules Hoist Ltd - 01 No
All as per item No. 1.00 here-in-before but EOT crane 10 ton capacity Make : M/S Pioneer cranes - 01 No
All as per item No. 1.00 here-in-before but EOT crane 12.5-ton capacity Make: M/S Braithwaite - 01 No
Material and labour for load testing of EOT/HOT/Monorail/Travelling crane double girder push button operated or in other means complete with/without electric motor etc by govt approved /authorized agencies . Including detailed inspection of all drives and all connected accessories of crane 0.5 Ton capacity complete as specified and as directed.
All as per item No. 12.00 here-in-before but 1 Ton capacity
All as per item No. 12.00 here-in-before but 2 Ton capacity
All as per item No. 12.00 here-in-before but 3 Ton capacity
All as per item No. 12.00 here-in-before but 4 ton capacity
All as per item No. 12.00 here-in-before but 5 ton capacity
All as per item No. 12.00 here-in-before but HOT crane 6 ton capacity
All as per item No. 12.00 here-in-before but 7.5 ton capacity single girder
All as per item No. 12.00 here-in-before but 10 ton capacity single girder
NOTE FOR ITEM NO.11.00 TO 19.00 :The Item includes inspection of the following sub systems and submitting report along with load test certificate duly load tested and signed by a Govt authorised / approved Engineer Any defect noticed by the Govt approved,authorided Engineer shall be rectified by the contractor and retest shall be carried out at his own cost. (A) LT DRIVE SYSTEM (a) Inspection for wear and tear of gears, drive shaft coupling, plummer block and brake liner, greasing, oiling, etc. (b) Checking of girders and carriage, coupling bolt, foundation bolt of gear box and motor (c) Checking of DSL system including carbon brushes brush holder insulators and tightness of copper conductors (d) Checking of serviceability of electric motors, power contactors, relays, limit switch, push buttons and electrical circuit cables and wiring. (B) CT DRIVE SYSTEM (a) Inspect wear and tear of gears, drive shaft, coupling plummer block and brake liner etc. (b) Checking of lightness of rail clamp bolts, alignment of rail joint (c) Inspection of cross travel conductor cable for motor power conductors, relays, limit switch, push button etc. (C) HOIST (a) Inspect /wear and tear of wire rope, hook block and brake lines etc. and testing of rope. (b) Checking of electrical circuit limit switch and wiring (D) LOAD FOR LOAD TESTING : (a) Contractor shall arrange necessary load as per the site requirement of the crane including shifting of load to the site by using crane, truck, labour, etc. (b) Contractor shall take care of the floor while shifting / lifting the load and if any damage found at site shall be rectifyed with in 24 hrs. (c) Load test shall not be more than 125 % of the rated load. (d) Contractor shall shift the load to inside the building for load testing of crane carefully by using crane / truck / fork lift / labour with out damage to the existing infrastructure. (e) Load testing shall be carry out as per ISO : 4310 of 1981 and IS : 14470 of 1997 with latest amendments on the IS . (E) TEST REPORT : On completion of the load test, a test report shall be prepared listing the conclusions and finding of the test for each crane. The report shall identify the crane tested, shall give the date and location of the tests, name of the engineer tested, details of load, positions, configurations and findings if any in each case. (vi) T&P for the load test and safety of the mechanic/engineer shall be at contractor's risk.
Attending any electrical or mechanical complaints of EOT/HOT crane of capacity 0.5 Ton to 5 Ton at different location at Naval Base Kochi with trained experienced skilled technician, checking thoroughly, detecting of faults and rectify the defects including trial run after rectification etc. all as specified and as directed Make: Cranex Ltd/ Indef / Life tech Eqpt Ltd / Electro mech
Attending any electrical or mechanical complaints of EOT/HOT crane of capacity 6Ton to 12.5 Ton at different location at Naval Base Kochi with trained experienced skilled technician, checking thoroughly, detecting of faults and rectify the defects including trial run after rectification etc. all as specified and as directed Make: cranex Ltd/ Braithwaite/ Indef/ M/s Pioneer Crane
NOTE FOR ITEM NO: 20.00 TO 21.00: (i) The mechanic / engineer will attend the complaints with in 48 hrs from the tele message / call from the AGE E&M or JE E&M and entered in complaint register maintained in the sub division including Sunday and holiday. (ii) If the contractor failed to attend the complaint within 48 hrs, a penalty of 2000.00 per day shall be recovered from his RAR / FB. (iii) The rate of minor spares required to rectify the complaint shall deemed to be included in the unit rate quoted costing up to. 500.00. In this regard GE's decision shall be final and binding. (iv)supply and fixing of major spares required for rectify the complaint shall be measured and paid separately under relevant item of this schedule (v) The contractor is bounded to send the mechanic / engineer with in 6 hrs during the VIP / VVIP visit to attend the complaint without fail, otherwise a penalty of ₹.500.00 will be recovered per hrs up to 24 hrs and ₹.1000.00 above 24 hrs and ₹.2000.00 above 48 hrs (vi) Tools for the repairs and safety of the mechanic/engineer shall be at contractor's risk.
Material and labour for hoist alignment of long drive assembly for crane as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd
Material and labour in replacement of current collector system for crane as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd
Material and labour in replacement of gear shaft of capacity 0.5 Ton to 5 Ton crane as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of gear shaft of capacity 5 Ton to 12.5 Ton crane as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of main hoist drive pinion for up to 5 Ton crane as per existing type and makecomplete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of main hoist drive pinion for 6 Ton to 12.5 Ton as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of brake coil for 100 mm and 150 mm dia of as per existing type and makecomplete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of Thruster Brakes are suitable for 400/440 Volts, 3 phase A.C. Supply for a range of drum sizes from 100 mm to 600 mm diameter as per existing type and make complete as specified and as directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of hoist gear pinion as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of gear coupling for LT as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of micro motor clutch assembly as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of limit switch up to 12.5 Ton capacity as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement ofy brake liner below 5 Ton capacity as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of brake liner 5 Ton to 12.5 Ton capacity as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of bearing for motor up to 10 HP complete as specified and directed.
Material and labour in replacement of over load relay, AC 415V suitable for 3 phase motor of rating up to 10 HP complete as specified and directed.
Material and labour in replacement of ball bearing for 3 ton capacity crane complete as specified and directed.
Material and labour in replacement of EOT crane wheel assembly as per existing type and make complete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Material and labour in replacement of Pendant push button station complete set as per existing type and makecomplete as specified and directed. Make: Cranex/ Indef/ Lifetech Eqpt Ltd/ Electro mech.
Supply and fix in replacement of high bay LED light fitting on cranes of capacity 80 Watt circular type, toughened glass, lumens 120 lumens/ Watt with 10 W SPD as stranded making it a robust solution for fixing in cranes ingress protection of IP66 with additional safety chain complete as specified and directed.
All as per item No 44 here-in-before but upto 11 KVA to 20 KVA,380 Volts UPS
All as per item No 44 here-in-before but upto 51 KVA to 80 KVA,380 Volts UPS
Material and labour in replacement of unserviceable/burnt PCB of UPS at site/workshop suitable for 10 KVA to 20 KVA of existing Make/model with new PCBs of suitable size/make as per existing complete as specified and as directed.
Material and labour in replacement of unserviceable/burnt PCB of UPS at site/workshop suitable for 4 KVA to 7.5 KVA of existing Make/model with new PCBs of suitable size/make as per existing complete as specified and as directed.
Material and labour in replacement of unserviceable/burnt PCB of UPS at site/workshop suitable for 80 KVA of any Make/model with new PCBs of suitable size/make as per existing complete as specified and as directed.
Supply and fix in replacement of only 20 KVA / 10 KVA UPS , 3 phase IGBT complete as specified and as directed.
Supply and fix in replacement of only 20 KVA / 10 KVA UPS , 3 phase inverter mother board complete as specified and as directed.
Supply and fix in replacement of only 7.5 KVA / 4 KVA UPS , 3 phase IGBT complete as specified and as directed.
Supply and fix in replacement of only 7.5 KVA /4 KVA UPS , 3 phase inverter mother board complete as specified and as directed.
Supply and fix in replacement of only 80 KVA UPS , 3 phase inverter mother board complete as specified and as directed.
Supply and fix SMF battery 12V 120AH including taking down old unserviceable battery and removing to store yard complete as specified and as directed.
Supply and fix SMF battery 12V 180AH including taking down old unserviceable battery and removing to store yard complete as specified and as directed.
Material and labour for servicing of electricity operated air compressor including the following :- (a) Filling upto the minimum level of compressor oil (b) Replacement of wornout fan belts. (c) Complete painting to the compressor with existing colour by using spray method Note:- Keep all 3 compressor in fully working condition for 11 months and any break down shall be attended with in 2 hrs with out fail
Material and labour for writing letters or figures (block. Roman, Italic or Indian) n exc. 30 cm high on cranes/ UPS /Air compressor with white paint including all materials such as ladders, safety equipments complete as specified and directed.
Wiring for circuit/submain wiring alongwith earth wire with the FRLS with PVC insulated copper conductor, single core cable in existing surface/ recessed as required of 2x10.0 sq. mm + 1x10.0 sq. mm as earth wire including takin down old submain wiring complete as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
Supply and fixing replacemet MCCBs of crane panels of the following capcities incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape for srl item Nos 62 to 64 all as specified and as directed. :-
3 Pole .415 V. fixed type, 25 to 100 Amps with breaking capacity 16 KA
3 Pole .415 V. fixed type, 200 Amps, with breaking capacity 36 KA
3 Pole .415 V. fixed type, 250 Amps, with breaking capacity 36 KA
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor in wall / ceiling with suitable clamps connected with suitable lugs including taking out the existing unserviceable cable for size 16 sqmm 4 core complete as specified and directed.
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor in wall / ceiling with suitable clamps connected with suitable lugs including taking out the existing unserviceable cable for size 25 sqmm 3.5 core complete as specified and directed.
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor in wall / ceiling with suitable clamps connected with suitable lugs including taking out the existing unserviceable cable for size 35 sqmm 3.5 core complete as specified and directed.
Material and labour for periodical maintenance of rooftop PV module/solar plants by inspecting/checking all parts/components with solar expert engineeers/technicians such as solar panels,solar inverters, DCDB, ACDB, AC cables, connections, earthing systems, LAs, GI & Aluminium strips etc carring out general preventive maintenance and replace the unserviceable items, if any such as AC cables, earthings, LAs, cable connectors, GI Aluminium strips, MCB's, MCCB's, repair to inverters, repair to ACDB's, repair to DCDB's, repair to solar panels etc. and make the solar plant servicable in all conditions and assuring of desired wattage of each module and rated power output as per the manfacturer recommandation complete as specified and as directed for Srl item Nos 68.01 to 68.30. Note :- Unit rate includes all the spare parts including MCB’s, MCCB's, surge protectors, AC cables, inverters including repairs etc all as mentioned above. Supply and fixing in replacement of inverters, DCDB's,ACDB's,DC cables will be measured and paid seperately under relevant items of this schedule.
Solar module of capacity 120 KWp installed at SFNA-P-290
Solar module of capacity 70 KWp installed at ALD-P-198.
Solar module of capacity 58KWp installed at ATC-P-4.
Solar module of capacity 50KWp installed at 900 MEN-A.
Solar module of capacity 50KWp installed at 900 MEN-B.
Solar module of capacity 50KWp installed at 900 MEN-C.
Solar module of capacity 50KWp installed at Venduruthy-ADMIN-P-150.
Solar module of capacity 50KWp installed at NSRY Pipe fitting shop.
Solar module of capacity 50KWp installed at NSRY Electrical shop.
Solar module of capacity 50 Kwp installed at NODPACl.
Solar module of capacity 40KWp installed at FATS F-63.
Solar module of capacity 40KWp installed at MOK SH 16 & 17.
Solar module of capacity 35KWp installed at ATD P-33.
Solar module of capacity 30KWp installed at INAS-342.
Solar module of capacity 30KWp installed at SNOM-P-60.
Solar module of capacity 20KWp installed at SFNA-P-323.
Solar module of capacity 20KWp installed at MI Room P-2.
Solar module of capacity 20KWp installed at AED P-102.
Solar module of capacity 20KWp installed at SNOM-P-350.
Solar module of capacity 10KWp installed at P-100 Navy House.
Solar module of capacity 6KWp installed at ASW School.
Solar module of capacity 5KWp installed at CRL.
Solar module of capacity 5KWp installed at MO(K).
Solar module of capacity 2KWp installed at ASW School.
Solar module of capacity 40KWp installed at Sukhthankar Block.
Solar module of capacity 25KWp installed at RN S Galley, Signal School.
Solar module of capacity 15KWp installed at PM Hall.
Solar module of capacity 20KWp installed at CTW Admin block.
Solar module of capacity 10KWp installed at CTW Garage.
Solar module of capacity 26KWp installed at 33 WEU.
Cleaning of PV module/panels bi monthly with soft cloth/ sponge consumables and water for 120 Kwp and removing dust/dirt/bird droppings all as specified and directed by Engg-in-charge. This includes taking energy readings every month from On/Off-grid solar inverter readings of power acheived to be taken and submitted as per format provided and complete all as specified and as directed.
All as per item No 70 here-in-before but capacity 70KWp installed at ALD-P-198.
All as per item No 70 here-in-before but capacity 58KWp installed at ATC-P-4.
All as per item No 70 here-in-before but capacity 50KWp installed at 900 MEN-A.
All as per item No 70 here-in-before but capacity 50KWp installed at 900 MEN-B.
All as per item No 70 here-in-before but capacity 50KWp installed at 900 MEN-C.
All as per item No 70 here-in-before but capacity 50KWp installed at Venduruthy-ADMIN-P-150.
All as per item No 70 here-in-before but capacity 50KWp installed at NSRY Pipe fitting shop.
All as per item No 70 here-in-before but capacity 50KWp installed at NSRY Electrical shop.
All as per item No 70 here-in-before but capacity 50 Kwp installed at NODPACl.
All as per item No 70 here-in-before but capacity 40KWp installed at FATS F-63.
All as per item No 70 here-in-before but capacity 40KWp installed at MOK SH 16 & 17.
All as per item No 70 here-in-before but capacity 35KWp installed at ATD P-33.
All as per item No 70 here-in-before but capacity 30KWp installed at INAS-34104.
All as per item No 70 here-in-before but capacity 30KWp installed at SNOM-P-60.
All as per item No 70 here-in-before but capacity 1040KWp installed at SFNA-P-31043.
All as per item No 70 here-in-before but capacity 1040KWp installed at MI Room P-104.
All as per item No 70 here-in-before but capacity 1040KWp installed at AED P-10104.
All as per item No 70 here-in-before but capacity 1040KWp installed at SNOM-P-350.
All as per item No 70 here-in-before but capacity 10KWp installed at P-100 Navy House.
All as per item No 70 here-in-before but capacity 6KWp installed at ASW School.
All as per item No 70 here-in-before but capacity 5KWp installed at CRL.
All as per item No 70 here-in-before but capacity 5KWp installed at MO(K).
All as per item No 70 here-in-before but capacity 104KWp installed at ASW School.
All as per item No 70 here-in-before but capacity 40KWp installed at Sukhthankar Block.
All as per item No 70 here-in-before but capacity 1045KWp installed at RN S Galley, Signal School.
All as per item No 70 here-in-before but capacity 15KWp installed at PM Hall.
All as per item No 70 here-in-before but capacity 1040KWp installed at CTW Admin block.
All as per item No 70 here-in-before but capacity 10KWp installed at CTW Garage.
All as per item No 70 here-in-before but capacity 1046KWp installed at 33 WEU.
Note for item 70 to 99:- (a) The tools, plants, water etc required for the cleaning shall be arranged by the contactor. (b) The reading of every month of solar plant has to be entered in a register and the same shall be submitted to the Engineer-in-charge duly signed.
Supply and fix in repair of Solar Inverter suitable for capacity 2 KWp, IP 66 complete all as specified and directed.
Supply and fix in repair of Solar Inverter suitable for capacity 40 KWp, IP 66 complete all as specified and directed.
Supply and fix in repair of Solar Inverter suitable for capacity 50 KWp, IP 66 complete all as specified and directed.
Supply and fix in repair of Solar Inverter suitable for capacity 70 KWp, IP 66 complete all as specified and directed.
Supply and fix in repair of DCDB suitable for capacity 20 KWp, IP 67 complete all as specified and directed.
Supply and fix in repair of DCDB suitable for capacity 50 KWp, IP 68 complete all as specified and directed.
Supply and fix in repair of ACDB suitable for capacity 20 KWp, IP 67 complete all as specified and directed.
Supply and fix in repair of ACDB suitable for capacity 50 KWp, IP 68 complete all as specified and directed.
Supply and laying in replacement of DC Cable 2 x 6 sq.mm multi stranded copper conductor 1100 volts with suitable cable lugs, MC4 connectors etc. complete all as specified and directed.
Supply and laying in replacement of DC Cable 2 x 4 sq.mm multi stranded copper conductor 1100 volts with suitable cable lugs, MC4 connectors etc. complete all as specified and directed.
Comprehensive maintenance of the AMR meters (90 Nos) installed at Naval Base, Kochi with Elmeasure complete all as specified and directed Note :- It is complete responsibility of the contractor to make the meters functional and tie up with elmeasure. If in any case the online reading is not generated, the contractor has to keep a meter reader to take the reading monthly
Scope on AMC:- (a) AMC is applicable for products manufactured by ELMEASURE like Meters, Display units, Gateway and Software etc. The items such as PC & UPS are not covered under AMC (b) Elmeasure will respond to any issue within 5 working Hours with the action plan (c) Regular visit will cover the inspection of meters installed at the customer premises. (d) To monitor AMC activities ELMEASURE have instant ticketing system through mail ID [email protected] (e) If the Elmeasure manufactured product is physically damaged or burnt and found non-serviceable, or If the meters are found tampered / opened by NON- ELMEASURE person or the customer, the product(s) will be excluded from the AMC cover (f) If the meters are found non-serviceable, contractor need to buy a new Energy meter. Since, Energy meters hardware’s are more than 5 Years old, same model components are not available. So, equivalent model will be supplied (Cost of new energy meter not included) (g) In future, if Contractor changed the static IP address in server, similarly customer need to change the static IP address to all the Energy meters. Elmeasure will not consider this activities in AMC (h) If any of the Elmeasure manufactured products at site are required to be serviced. Contractor need to send the defective meters to ELMEASURE (Sending Courier charges to be borne by customer) & ELMEASURE shall service and send the same by courier (Shipping back courier charges to be borne by ELMEASURE) to contractor (i) Contractor need to take the solution / precaution to avoid further failure. While servicing if it is found that the reason for the defect is due to non-adherence of the user guidelines then that device will be considered as out of AMC service. In such cases cost of the components that were replaced plus the service charges will be applicable (j) In case the contractor requires support over phone and doesn’t call for site visit, CSE will provide phone assistance or if customer provides remote, CSE will assist the customer though remote access to solve the issues
(k) End of the visit day field support report will be prepared by the CSE along with the contractors representative that presents the day’s work carried out at the site by the CSE (l) Contractor should acknowledge / sign the Field Service Report (m) Period to rectify the meters: 10 working days, Any EMS software modification if required, ELMEASURE will evaluate the Software requirement and confirm that, whether the modification is possible or not, also if possible, how much it would cost and delivery date etc (n) EMS database auto backup facility will be provided. Customer to ensure database backup is happening (o) If the system crashed during the AMC period, Elmeasure will install the EMS software for 1 time at free of cost (as per pervious configuration, operating system need to be compatible) and existing back-up will be restored in as-is condition, hence it is customer responsibility to ensure proper back-ups taken at regular intervals (p) Contractor has to ensure maintaining the database backup (q) EMS database auto backup facility will be provided. Customer to ensure database backup is happening in a external hardware (to be arranged by contractor)
Supply and fix in repairs of AMR meter PE 5120-P Three phase dual source prepaid meter, class 1.0, RS 485, 5A CT Operated including all CT’s, cabling, enclosure etc complete all as specified and directed.
WELTRONENGINEERINGSERVICES (BID ID -3469495)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
COMMONPAGES8579.pdf
Tender Documents • 0.56 MB
PS8579.pdf
Tender Documents • 0.38 MB
BOQ_823287.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid