Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹10 L
EMD Value
₹7,500
Closing Date
25 Nov 2026, 7:00 pmDue today
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Ex.Eng (O&M) Valsad Rural Division
Maintenance and Erection work of HT/LT line and TC network for Billimora Rural (Antaliya) Sub-Division (Zone-2) for Various schemes in various Feeder under Valsad-Rural Division.
365872
DGVCL/VALSAD-R DO/E-TENDER/2026-27/129
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹885
DGVCL, Payable Valsad
₹7,500
16 Nov 2026
16 Nov 2026
16 Nov 2026
25 Nov 2026
16 Nov 2026
180 days
Sr. Item Code Details of Works Unit Qty. Rate Amount
9924000001 Cutting of Tree branches
1 Per Tree 57/-
surrounding HT/LT line
9924000002 Replacement of old jumpers &
providing new double jumpers with
8" binding [D Type] & capsuling
with PVC pipe etc.
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633/-
9924000006 Pin binding of conductor 11/22kv
9924000007 Pin binding of conductor 11/22kv
5 Pin insulator per pole in coastal No. 41/-
area with cleaning.
9924000008 Pin binding of conductor LT shackle
9924000009 Replacement of one/both disc
insulator at strain pole
9924000010 Replacement of LT shackle
insulator at cut point
9 9924000011 Re-fixing of V cross Arm No. 61/-
9924000012 Replacement of V cross Arm (With
Transportation & Painting)
9924000013 Re-fixing of Top fitting in proper
12 9924000014 Replacement of Top fitting No. 51/-
13 9924000015 Replacement of LT cross Arm No. 105/-
9924000016 Providing DO fuse on DP with
14 carting & jumpuring(ONE DO No. 243/-
9924000017 Numberings of pole with paint by
preparing back ground of one
colour and have lettering(height 3"
* width 0.5") using stencil
9924000018 Fixing of MMB(1PH.) at consumer
9924000019 Fixing of MMB(3PH.) at consumer
9924000020 Replacement of (1ph.) meter for
9924000021 Replacement of (1ph.) meter for
9924000022 painting consumer no. on MMB
20 (Urban) (with letter size height No. 11/-
40mm* width 8mm)
9924000023 painting consumer no. on MMB
21 (Rural) (with letter size height No. 19/-
40mm* width 8mm)
9924000024 Replacement of deteriorated Single
phase Service line
9924000025 Fixing of new dist. Box with
23 complete wiring including clamps, No. 816/-
9924000026 Repairing of guarding involving
24 reshaping of bearer wire cross R Mtr. 25/-
lacing binding etc.
9924000027 Painting of steel fabricated
25 material of RSJ DO DP structure No. 2406/-
9924000028 Painting of steel fabricated
material of RSJ pole mounted
transformer double pole structure
9924000029 Painting of steel fabricated
27 material of RSJ single pole with No. 902/-
9924000030 painting of steel fabricated
28 material of PSC Single pole (HT No. 135/-
line) with paint
9924000031 painting of steel fabricated
29 material of PSC DO DP double pole No. 362/-
9924000032 painting of steel fabricated
30 material of PSC double pole at pole No. 723/-
mounted transformer with paint
9924000033 Providing line separator single
9924000034 Providing line separator three
9924000035 Replacement / Providing of stay
33 insulator along with adjustment of No. 276/-
tension in stay wire
9924000036 Replacement of deteriorated
/providing LT dist. Box with new up
to 100KVA capacity & crediting it to
9924000037 Replacement of deteriorated
/providing LT dist. Box with new
above 100KVA capacity & crediting
36 9924000038 Adjustment of tension in stay wire No. 158/-
37 9924000039 Refitting of LA No. 31/-
9924000040 Converting pin point to Shackle
38 point including dismantling & location 2232/-
restringing etc.
9924000041 replacement of 11KV Pin insulator
39 with providing new double pin No. 60/-
9924000042 replacement of 22KV Pin insulator
by new 11kv pin insulator with
spares & providing new double pin
9924000043 Providing 11kv double disc
41 insulators with binding & No. 161/-
Replacement of existing 11kv
42 conductor (all size) with new Cond/KM 4354/-
double pin binding
9924000046 Plumbing of PSC Pole with
straightening at pin point
9924000047 Plumbing of PSC Pole with
straightening at tension point
9924000048 Plumbing of tilted DP structure
45 (PSC/RSJ/STP) with refilling of No. 816/-
stone Murrum etc.
9924000049 Providing new 11kv AB /GO switch
with fabrication and insulated
46 colour code jumper, binding, lugs Set 1290/-
Replacement of old 11kv AB /GO
switch with providing new
insulated jumper, binding, lugs etc.
9924000052 Providing cage type loop guard in
48 vertical LT line with using PVC reel per pole 53/-
insulators etc.
9924000053 Labour charges for replacement
/providing of MMB & service with
all accessories for three phase
9924000054 Labour charges for replacement
/providing of MMB & service with
all accessories for single phase
9924000055 Dismantling of existing Dist.X'mer
center (RSJ /STP POLE)
51 25/63/100/200 KVA with all No. 5528/-
fabrication & crediting the old
material to store.
9924000056 Disconnection from LT pole
53 9924000057 Reconnection from LT pole 1 phase
(payment after receipt of R/C No.
9924000058 Disconnection from LT pole
55 9924000059 Reconnection from LT pole 3 phase
(payment after receipt of R/C No.
9924000060 Dismantling & removing of service
56 line from pole & crediting to S/dn No. 111/-
9924000061 Dismantling & removing of service
57 line from pole & crediting to S/dn No. 205/-
9924000062 Reconnection of service line
complete with PVC cable (1 Ph)
Reconnection of service line
complete with PVC cable (3 Ph)
9924000064 Providing spiral type earthing by
G.I. NO 8(weight 2kg -5mtr in
length) with salt and coal 10kg
each, including pvc rigid pipe
60 20mm dia( 1.5mtr length) to pass No. 816/-
exposed part of G.I. wire at
consumer end with all materials,
earth resistance should be less
9924000070 Providing and fixing of signle core
1.5 sq mm single strand copper
insulated cable with cable nail clip
for spiral type earthing at
61 consumer end. The end of G.I. no per meter 30/-
8 is to be connected by connector
with copper cable of which other
end shall be connected to the earth
terminal of meter box. This item
shall be used in location where
there is more distance between
earth terminal and earthing
terminal of meter. (All materials
supplied by contractor)
9924000065 Stringing of LT ABC of 1*35 SQ MM
+ 1*25 SQ MM including fitting of
all accessories i.e. special design
suspension / tension clamp, fixing
of cross arm, LT shackle insulator
etc. for fixing of messenger wire
and inclusive of dismantling charge
of existing bare conductor and
crediting in to store & dismantling
of service line from LT bare
conductor and to provide service
connection on Aerial Bunch Cable
by insulated piercing connectors
through service connection box
complete as required & directed by
Engineer in Charge.
9924000066 Stringing of LT ABC of 3*50 SQ MM
including fitting of all accessories
i.e. special design suspension /
tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing
of messenger wire and inclusive of
dismantling charge of existing bare
63 conductor and crediting in to store KM 22303/-
& dismantling of service line from
LT bare conductor and to provide
service connection on Aerial Bunch
Cable by insulated piercing
connectors through service
connection box complete as
required & directed by Engineer in
9924000067 Stringing of 11KV ABC of 3*95 SQ
MM +80 SQ MM including fitting of
all accessories i.e. special design
suspension / tension clamp, fixing
of cross arm, binding to pin
64 insulator, preparing shackle point, KM 44608/-
jumpers etc. and inclusive of
dismantling charge of existing bare
conductor and crediting in to store
complete as required & directed by
Engineer in Charge.
9924000068 Stringing of 22 KV ABC OF 3*70 SQ
MM +95 SQ MM including fitting of
all accessories i.e. special design
suspension / tension clamp, fixing
65 of cross arm, binding to pin KM 55019/-
insulator, preparing shackle point,
jumpers etc. and inclusive of
dismantling charge of existing bare
conductor and crediting in to store
complete as required & directed by
Engineer in Charge
9924000069 Stringing of LT ABC of 2*50 SQ MM
including fitting of all accessories
i.e. special design suspension /
tension clamp, fixing of cross arm,
LT shackle insulator etc. for fixing
of messenger wire and inclusive of
dismantling charge of existing bare
66 conductor and crediting in to store KM 15613/-
& dismantling of service line from
LT bare conductor and to provide
service connection on Aerial Bunch
Cable by insulated piercing
connectors through service
connection box complete as
required & directed by Engineer in
Total of schedule - B2
Total of schedule B1 & B2
(+)_______%Above, (-)_______%Below, Rate to Rate…..
Net Total of Schedule ‘B1 & B2:
Amount in Words: (Ten Lacs Only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Billimora Rural (Antaliya) Sub-Division under Valsad-
Rural Division.
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary accessories to
the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and crediting in to store &
dismantling of service lines from LT bare conductor and to provide service connections on ABC by
insulated pierce connectors through service connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as credit the
dismantle material to the DGVCL store at their cost.
7. DGVCL will provide key material like M.S. materials, ABC/Bare conductors, PSC/RSJ Poles,
Insulators, Fabricated materials etc. to the contractor.
8. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods
confirming to the relevant ISI specification and as directed by Engineer in charge.
9. Necessary electricity connection for fabricated items shall be provided by DGVCL on payment of
required charge for connection & electricity bill of the same shall be paid by the agency.
10. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
11. All steel material is to be painted as below:
a. Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles is must require.
b. Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ
poles & steel fabricated materials of RSJ/PSC poles.
c. Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver
paint) are to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC
Executive Engineer (O&M)
Valsad Rural Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Amend an Arbitration Clause.pdf
GENERAL TERMS and CONDITIONS.pdf
Notice Inviting Tender.pdf
Schedule-B.pdf
TECHNICAL BID.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .