Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹7.2 L+₹8,040 (1.13%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹7.3 L
EMD Value
₹14,560
Closing Date
8 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR/MAINT OF SUMMER COOLING APPLIANCES AT RALAWAS AREA UNDER GE BANAR
2023_MES_578869_1
8822/75/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹14,560
Yes
14 Mar 2023
3 Feb 2023
11 Mar 2023
3 Feb 2023
8 Mar 2023
17 Feb 2023
Amount
M&L for Taking out window/Split type AC of capacity up to 2 Ton from the site of any make for servicing, cleaning with air blower of fins, cleaning of condensing unit, cooling coil and evaporative coil with caustic soda mix water,taking out all dirt/sludge etc. by using pressure pump ,cleaning of air filter incl. Oiling and greasing of condensing fan motor, replacement of remote cell/battery replacing worn out rubber,bushes/rubber packing rectification of unusual noise, replacement of minor parts such as nut/bolts,washers etc and reassembly of complete AC unit and testing complete for smooth functioning to entire satisfaction of Engineer-in-Charge shall deemed to be included in the quoted rates.
M&L for Topping up of refrigerant as per the existing refrigerant upto the required level for window /split type AC of capacity 1.5/2 ton complete all as specified.
M&L for complete Gas charging as per the existing refrigerant up to the required level including replacement of NRV for window/Split type AC of capacity 1.5/2 Ton complete all as specified.
M&L for Taking out defective compressor Sealed Rotary / Reciprocating unit of window AC of cap 1.5 Ton incl.cutting of copper tubing without any damage to existing other parts and Material and labour for replacement of compressor/ sealed unit complete with erection of compressor in same location with suitable base,jointing of copper refrigerant pipe line,charging of gas to required level,leakage testing,NRV etc. including testing for smooth functioning. NOTE : (i)The rate quoted by the contractor shall be inclusive of all charges like transportation,fittings,etc. complete with necessary guarantee period including oiling and environment friendly gas charging , testing etc.complete all as specified.
All as per ser Item No 4.00 above but split type AC of cap 1.5 Ton complete all as specified.
All as per ser Item No 4.00 above but split type AC of cap 2 Ton complete all as specified.
M&L for replacement of blower bush of split type AC having capacities of 1.5/2 Ton complete all as per the sample existing at the ground complete all as specified.
Supply and fix in repair blower fan motor of suitable size for indoor type split AC of cap 1.5/2 Ton complete all as specified.
Supply and fix in repair condensor fan motor suitable for out door type split AC of capacity 1.5/2 Ton complete all as specified.
S & F in replacement for blower of approved make suitable for window type AC of cap 1.5/2.00 Ton complete all as specified.
S&F in replacement of running capacitor, 45/60 mfd suitable for 1.5 /2 Ton capacity window/split type AC of approved make complete all as specified.
S & F in replacement capacitor 6/10 mfd suitable for split / window type AC complete all as specified.
M&L for repairing of PCB control kit of window / split type AC of capacity 1.5/2Ton complete all as specified.
M & L for replacement of PCB control kit suitable for window/split type AC of capacity 1.5/ 2 Ton complete all as specified.
Takingdown indoor & outdoor unit of 1.5/2TR split AC and refix again on existing/another location including fastners complete all as specified.
S&F in replacement of Thermostat (Thermal sensing bulb) suitable for split/window type AC 1.5 /2 Ton capacity of approved make complete all as specified.
S&F in replacement of starting and running relay suitable for window/ split type AC 1.5/2 Ton capacity of approved make complete all as specified.
S&F in replacement of over load protection suitable for window/ split type AC 1.5 /2 Ton capacity of approved make complete all as specified.
Supply & Fix in replacement of drain out pipe suitable for AC 1.5/2 Ton of approved make complete all as specified.
Supply and fix in replacement of condensing coil of window type AC of capacity 1.5 Ton complete all as specified.
Supply and fix in replacement evaporating coil of window type AC of capacity 1.5/2 Ton complete all as specified.
Supply and fix in replacement of evaporating coil of split type AC of capacity 1.5 /2 Ton complete all as specified.
Supply and fix in replacement of condensing coil unit complete of out door unit of split type AC of capacity 1.5/2 Ton with approved make complete all as specified.
M & L for replacement of chocked copper tube of size 1/4" of split type AC 1.5/2 ton cap complete all as specified.
M & L for replacement of chocked copper tube of size 1/2" of split type AC of 1.5 /2 ton cap complete all as specified.
M & L for insulation coating /PVC air bubling insulation of circular dia to copper tube to upkeep the required temperture and over all protection to copper tubing of size 1/4" or 1/2" complete all as specified.
M & L for taking out water Cooler from site of any capacity and make for servicing incl. cleaning of cooling tank and condencing coil with C sine cemical mixed water, taking out all dirt , sludge deposited, incl. oiling / greasing of condensing fan motor rectification of unusual noise, replacement of minor parts such as nut/bolt washers etc as directed with writing of serial No SM/MES No. and re installed the water cooler in position complete all as specified.
M&L for Topping up environment friendly refrigerant as per existing suitable for water cooler up to the required level of 40/80 ltr complete all as specified.
M & Labour for spray painting to water cooler of capacity 40 lit and cooling capacity 80 lit per hour by painting outer cover with two coat of synthetic enamel paint of approved make complete all as specified.
M&L for Taking out defective sealed compressor unit of 40/80 Ltr/hr cap of water cooler and M & L for replacement for sealed compressor unit of suitable for water cooler of 40/80 lit/hr cap , reassembly and testing complete as to the entire satisfaction of Engineer-in- Charge.
M & L for finding out leakage of condensor/ cooling unit of water cooler of 40/80 Ltr cap including dismantling the same for recharging and stop leakage by brazing/soldering including charging with existing gas up to required level and testing complete as to the entire satisfaction of Engineer-in- Charge.
Material and Labour for replacement of capacitor 10 mfd oil filled for water cooler complete all as specified.
Supply and fixing OLP rellay suitable for water cooler,Refrigerator and deep freezer of any capacity complete all as specified.
M & L for replacement of condenser fan motor of water cooler 40/80 ltr/hr capacity as per existing sample or approved make and testing complete all as to the entire satisfaction of Engineer-in-Charge.
M & L for replacement of fan blade of water cooler/blower as per existing sample at the ground complete all as specified.
S & F in repairs of Thermostat suitable for water cooler 40 Ltr/hr capacity of approved make complete all as specified.
Supply and fix in replacement of Ball brass valves size 15mm, high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule complete all as specified.
M&L for replacement of defective sealed compressor unit upto 320 Ltr cap refrigerator. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make it functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of refrigerator upto 320 Ltr cap, stop leakage by brizing/soldering including charging the environment friendly refrigerant up to the required level and testing the refrigerator for the entire satisfaction of EIC.
M&L for replacement of defective sealed compressor unit of 320 ltr cap deep freezer. The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee period including checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified.
M&L for finding out leakage with the pressure testing of the condensor/ cooling unit/ compressor of deep freezer 320 Ltr cap, stop leakage by brizing/soldering including charging with existing refrigerant to required level and testing the refrigerator for the entire satisfaction of EIC.
S & F replacement of defective swing motor with new motor suitable for 1.5/2 ton window and split type AC all as specified.
Supply and fix in replacement of front grill for window type AC 1.5 /2.0 TR. Complete all as specified.
Supply and Fix in replacement of remote with new suitable for machine of 1.5/2.0 TR split type AC complete all as specified.
Dismantling to voltage stablizer upto 4 KVA for repair including assembling , testing after repair work complete all as specified. Note:- Spare parts will measured under item no 50.00 & 51.00
S&F in replacement of Indoor unit complete with cooling coil, blower/ fan, motor complete suitable for 1.5 Ton split AC complete all as specified.
S&F in replacement of outer cover of outdoor cabinet of split AC 1.5Ton with stand including fashner,nut,bolts etc complete all as specified.
S&F in replacement of 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified.
Supply only Circuit board suitable for upto 4 KVA complete all as specified.
Supply only relay suitable upto 4 KVA complete all as specified.
vinayandsons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .