GTL Div: [1] Provision of Solar Plants at Stations and Service Buildings to Neutralize Additional Connected Load for Achieving Shunya/Shunya+. [2]Provision of Remote Monitoring System for Solar Power Plants across the Division.
GTL-EM-31-2026-27
GTL-EM-31-2026-27
Open
Works - General
6 Months
Erode, Tamil Nadu
₹0
₹8.0 L
21 Jul 2026
21 Jul 2026
29 Jul 2026
Survey, Design, Supply, transportation, installation, testing and commissioning of different capacity (5 KWp to 50 KWp ) Grid connected rooftop solar plant consisting Mono PERC - crystalline Panel, Inverter (pure sine wave), with remote monitoring system including SIM with 5 years, net connectivity, fixing structure and all other accessories including Lightening Arrestor, 1 proper earthing, Net Meter and Generation meter( From DISCOM), Controls and Protections, Single Phase Preventer, interconnect cables, cable trays for DC cabling , civil works, and switches all complete at stations( COP/ Buildings) as per the as per MNRE Standards and Specification No. RDSO/PE/SPEC/PS/0092-2008 (Rev. '0'), Amdt. 5 with five-year AMC/ CAMC including cleaning. Any charges of electricity board to be borne by contractor regarding metering of solar power and approvals. Above/
B-Cabling and allied works connected to solar plant 17854876.02 Below/P
Supply of 4 core 185 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988 or latest amendment.
Supply of 4 core 120 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988.
Supply of 4 core 95 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988 or latest amendment.
Supply of 4 core 70 sqmm XLPE insulated underground armoured aluminium cable with heat resistant insulation as per IS 7098(Part 1)1988.
Laying of 4 core LTUG cable of size 70/95 sqmm in the trench and connected at both the ends complete.
Laying of 4 core LTUG cable of size 120 sqmm and above in the trench and connected at both the ends complete.
Supply and laying of 8 SWG GI wire with 40GSM Zinc coated, conforming to IS:280- 2006 or latest, it is to be laid with armored cable for earth continuity.
Supply and fixing of HDPE pipe of 90 mm outer dia of PE-100, PN6 class with minimum wall thickness of 3.5 mm with suitable couplings and clamps for cable laying with all necessary accessories complete.
Supply and fixing of HDPE pipe of PE-80 grade in PN-4 size 2" inner dia and outer dia 63 mm and wall thickness minimum 2.5mm, maximum 2.8 mm with 'T' joints, bolts, elbows etc. including all other connected accessories.
Supply and fixing of HDPE pipe of 75 mm outer dia of PE-100, PN6 class with minimum wall thickness of 3.5 mm with suitable couplings and clamps for cable laying with all necessary accessories complete.
Excavation of cable trench in all types soils of size 400mm wide x 1 mtr. deep, and 11 making good of the same to its original form and shape after complete including all connected materials and works up to the satisfaction of the Engineer at Site and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013 The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge.
Excavation of cable trench in rocky soil of size of size 400mm wide x 1 mtr. deep, 12 and making good of the same to its original form and shape after complete including all connected materials and works up to the satisfaction of the Engineer at Site and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013
Excavation of cable trench in cement concrete bed flooring by using power drill to a depth of 1.0 Mtr and a width of 0.3mtr. After laying the pipe and refilling the trench with excavated 13 earth and undertaking cement concrete bed flooring to its original shape as was prevailing earlier to the satisfaction of Railways site Engineer and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge.
Excavation of cable trench of size 400mm x 1 mtr deep track X-ing/Road X-ing and 14 making good of the same to its original form and shape completely including all connected materials and works to the satisfaction of Railways site Engineer and also as per R.B JPO no: No.2003/Tele/RCIL/I Pt.IX dated 24.06.2013.The exact route of the HT/LT cable is to be decided in consultation with Engineer in charge.
HT/LT Cable laying by horizontal boring below track etc by pushing method-Drilling 15 for horizontal bore below track by pushing method by suitable means for laying of GI pipes/ HDPE pipe etc of various sizes, the bore shall be of 200 mm dia & shall be done at a depth of 3000 mm from ground level, it also includes insertion of pipe.
Supply and Erection of Power cable route indicators with all connected materials and works as per Drawing No.DEE/CN/BZA/2001/23.
Preparation and submission of completion drawings in A3 size with all relevant details 17 and measurements of executed installations, solar panel placement, SLD, cable routings, etc. The drawings shall be submitted in1(Soft Copy) + 3 (Hard Copy) duly signed by the concerned Supervisor, contractor, controlling officer and to be furnished along with bills.
Supply and Installation of 150mm x 50mm x 2mm thick GI perforated cable tray with cover along with required angle supports, with coupler plates, Anchor bolts and nuts etc complete and the tray should be fitted on the wall / Ceiling etc. complete.
Supply, running and connecting of 4 core 10 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010
Supply, running and connecting of 4 core 16 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010
Supply, running and connecting of 4 core 25 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010
Supply Installation Testing and commissioning of free-standing floor/Wall mounted dust and vermin proof panel of IP 65 rating for fixing of solar invrters, Solar AC & DC DB, MCCB's/MCBs & Generation meter made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene 22 rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator). Consignee Inspection.
Provision of Foundation/Platform for installation of LT panels.
Supply and installation of thermal magnetic based release; Icu = 36kA; 100A 4 Pole MCCB conform to IEC 60947-2 of model no. IHQT2EC50100 of Havells make or it's equivalent with extended ROM, spreader links (2 sets).
Supply and fixing of 40/50/63A 4P MCB C Curve, 10 KA capacity with necessary connections and all accessories complete.
Supply and fixing of 6A-32A 4P MCB C Curve, 10 KA capacity with necessary connections and all accessories complete.
Supply, transportation & installation of size 450mm x 50mm x 2.0mm of Hot Dipped 27 Galvanized Iron ladder type cable trays with rungs at span of 250 mm including horizontal and vertical bends, reducers tees, cross members and other accessories complete to place on the valley gutter to provide walkway on the COP of the platform for cleaning and maintenance of the solar panels.
Supply and fixing of 6mm thick ISI marked MS Chequered plate as per on above ladder cable tray to provide walkway on the COP of the platform for cleaning and maintenance of the solar panels. Above/
C-Remote Monitoring System for solar power plant 523898.76 Below/P
Design, supply, Installation, testing and commissioning of 4G based Plug and Play - 1 RTU with antenna, Smart data logger of model no: E Track 150i 4G of LOGICS POWERAMR PRIVATE LIMITED or its equivalent and as per 6.7.2 of Specification No. RDSO/PE/SPEC/PS/0092-2008 (Rev. '0'), Amdt. 5 to connect inverters and Weather sensors
Supply and fixing of IP 67 enclosure box with SMPS power supply and other accessories to house the RTU
Access to Web portal- server charges for 1 year Data frequency in line - 10 minute Key Components • Interactive Dashboard • Single Line Diagram • PR analysis • Solar radiation & weather data • Graphs and Reports • Superuser Dashboard for Centralized monitoring
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CEGE Technical Circular
ATTACHMENT
ListofLikelySuppliers.pdf
ATTACHMENT
GCC Apr 2022 with Correction slips
ATTACHMENT
JPO Digging of cables
ATTACHMENT
EarthingSpecificationMFEandOther.pdf
ATTACHMENT
Grid connect solar Specification
ATTACHMENT
RITESInspection.pdf
ATTACHMENT
Scope of work
ATTACHMENT
NITIREPSWorks.pdf
ATTACHMENT
CEGETechnicalCircular07-04-2022_compressed.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips._compressed.pdf
ATTACHMENT
RlyBd-JPO-DiggingofCables2013-Re-Circulatedin2022-LATEST.pdf
ATTACHMENT
0092_Amdt-5_GridConnectedsolarsystem_130819.pdf
ATTACHMENT
ScopeofworkforABSSSOLARTENDEREM-31-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].