Loading…
Loading…
Tender Value
₹24.0 L
EMD Value
₹24,000
Closing Date
4 Aug 2026, 5:00 pm
SE LI CANAL DIVISION KHARIAR
O/o THE SE LI CANAL DIVISION KHARIAR,DIST-NUAPADA, PIN-766107
Internal Electrification to Science Museum at Dam site, Tikhali of Lower Indra Irrigation Project under the Scheme Periphery Development of Reservoir and Water Bodies for the year 2026-27
2026_CCELI_136956_2
SELICD-02/2026-27
Open Tender
Electrical Works
Percentage
60 days
DAM SITE TIKHALI
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹24,000
Yes
24 Jul 2026
24 Jul 2026
5 Aug 2026
24 Jul 2026
4 Aug 2026
24 Jul 2026
24 Jul 2026 - 31 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUB-HEAD I (MODULAR WIRING ITEMS) Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kabel/ Kei with 20 mm dia HMS FRLS PVC conduit ISI marked Make- AKG/ Bec/ Precision/ Norpack/ Anchor/ Kinjal 6A modular type (flame retardant type) switch ISI marked Make- Schneider (Zencelo)/ legrand (Myrius)/ Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (flame retardant type) Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) of suitable size, modular box with 1.5 sq.mm FRLS PVC insulated single core multistranded copper conductor as earth wire including all accessories and connection as per direction of Engineer-in-Charge. All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Each light point should have provision for ceiling rose and angle holder point. In all the rooms there shall be two types of switchboard- one for raw and the other one for emergency. The inverter switchboard shall include at least one fan, one light and one 6A emergency socket. | |||||
| 1.1 | Group-A | - | Nos | 620.9 | - |
| 1.2 | Group-B | - | Nos | 923.7 | - |
| 1.3 | Group-C | - | Nos | 1,308.9 | - |
| 2 | Supplying, fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg.-in-Charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | - | Nos | 196.1 | - |
| 3 | Supplying, fixing of 6A Plug on the separate board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) (flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg.-in-Charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | - | Nos | 553.8 | - |
| 4 | Supplying, fixing of 1X16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket (modular type) (flame retardant type) with suitable size modular box & cover (flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipment power). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | - | Nos | 691 | - |
| 5 | Supplying, fixing of 2X6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket (modular type) ((flame retardant type) with suitable size modular box & metallic cover plate (both side) (flame retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make- Schneider(Zencelo)/ legrand (Myrius)/ Panasonic (vision) (For equipment power)(Maximum 02 nos point in one circuit). All the switches & sockets should be warranted for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. | - | Nos | 1,192 | - |
| 6 | Supplying, fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( ( flame retardant type) with suitable size modular box & metallic cover plate (both side)( flame retardant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( |( Myrius))/ Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit). All the switches & sockets should be warrantied for a replacement period of 2 years against defects with necessary test report & Warranty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. | - | Nos | 1,997 | - |
| 7Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/ Anchor/ Polycab/ Havells/ RR Kabel/ Kei in recessed HMS FRLS PVC conduit of mentioned size Make- AKG/ Bec/ Precision/ Norpack/ Anchor/ Kinjal as required as per direction of Engg.-in-Charge. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
BID002.pdf
Tender Documents • 2.50 MB
BOQ_603139.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].