Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC first lowest | |
| 2 | L2₹10.3 L+₹1.9 L (23.2%)Rejected-AOC | L2 | Rejected-AOC second lowest |
Tender Value
₹8.3 L
EMD Value
₹20,803
Closing Date
22 Feb 2024, 6:00 pmClosed
Assistant Executive Engineer
PWD Electrical Sub Division, Palakkad
Installation of individual RCCB for OT Ward OPD Block lift car supply in Govt. Medical college hospital, Palakkad Balance Electrical Works, IIMs Govt. Medical College Palakkad
2024_PWD_659686_1
ET-54/ESDPKD/2023-2024
Open Tender
Electrical Works
Item Rate
30 days
Palakkad
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,835
₹20,803
Yes
15 Mar 2024
16 Feb 2024
26 Feb 2024
16 Feb 2024
22 Feb 2024
16 Feb 2024
Amount
Wiring
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.14.8:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD195509/2023-2024:Supply, conveyance, installation , testing and commissioning of exhaust fans of size 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required
OD196595/2023-2024:Supply and clamping the following sizes of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required (for horizontal run).75 x 10 mm GI strip tinned at the points of contacts
OD237630/2023-2024:Excavation for cable trenches in soft soil, depth upto 2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD238364/2023-2024:Supply and laying the following sizes of strips existing trench as required 2 run 75 x 10 mm GI strip tinned at the points of contacts
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
OD232184/2023-2024:Supplying and fixing TPN sheet steel enclosure on surface/ recess, Testing and commissioning etc. as required.
OD233357/2023-2024:Charges for cutting holes suitable for accommodating exhaust fans up to 600mm sweep including plastering colour washing etc. as required.
OD237308/2023-2024: Toilet Ventilation Supply, Installation, Testing and commissioning of exhaust air fan section suitable for Inline mounting comprising of forward curved centrifugal blower complete with external rotor induction motor, metal clad MCB & starter switch all compete as required, suitable for three phase, 415 volts, 50Hz AC. supply as per specifications of following capacities: Make: Greenheck SQ-M-160J or equivalent Capacity Static Pressure 3000 CFM (Toilet) 20 mm WG"
Appu Velayudhan
Bidder Name
Mohammed Rafik
Appu Velayudhan
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1021085.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .