Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-AOC AOC accepted. | |
| 2 | L2₹41.2 L+₹2.6 L (6.77%)Rejected-AOC VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC AOC rejected. | |
| 3 | L3₹43.0 L+₹4.4 L (11.5%)Rejected-AOC 239 PHASE 2 MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-AOC AOC rejected. | |
| 4 | L4₹43.1 L+₹4.6 L (11.9%)Rejected-AOC | L4 | Rejected-AOC AOC rejected. | |
| 5 | L5₹43.4 L+₹4.9 L (12.6%)Rejected-AOC | L5 | Rejected-AOC AOC rejected. |
Tender Value
Refer Docs
EMD Value
₹76,600
Closing Date
30 Sept 2021, 6:00 pmClosed
GE DEHRADUN
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Special repair of roof sheet, ceiling and plaster work of main offices bldg No P-2 in HQ UK Sub Area Dehradun under GE Dehradun.
2021_MES_472346_1
8344/A/E8
Open Tender
Civil Works
Item Rate
180 days
GE DEHRADUN
Class D cat a (i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹76,600
27 Oct 2021
2 Sept 2021
2 Oct 2021
2 Sept 2021
30 Sept 2021
16 Sept 2021
Amount
Dismantling Plain or corrugated steel sheeting of any gauge, thickness, including Nainital or similar pattern roof/wall coverings etc complete all as specified & directed.
Dismantling timber scantlings 40 sqcm and over in section, framed or unframed work, in any position complete all as specified and directed.
M&L for second class hard-wood, scantlings wrought in roof trusses (framed), trussed purlins work etc complete all as specified and directed.
Dismantling structural steel work including doors, gates etc of any description and in any position complete all as specified.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming Fe-290 (Gde E-165)complete all as specified and as directed.
S & F Pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed vwith self tapping screws as specified
S&F pre-painted galvalume aluminium zinc coating GI based corrugated plain steel sheet 0.50mm thick of an ecofriedly colour having tensile strenght of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
M/L applying two coats of synthetic enamel paint over a coat of pink primer to new wooden surfaces including preparation, exc 10 cm width or girth, complete all as specified.
M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 15mm thick on fair faces in cement mortar 1:4 using water proofing compound, if required including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces in cement mortar 1:6 including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound (powder) as per manufacturere instructions complete all as specified.
Dismantling of walls/ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs / blankets, any thickness including cover fillets etc, complete all as specified and directed.
Providing & fixing tiled false ceiling of Everest Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizental level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and croos 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of 1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable rods of 3mm dia with galvanised Butterfly level clips or 3mm dia GI wire spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm. All 'T'' sections shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engineer-in-Charge.
M&L for complete removal of existing treatment of ceiling and applying two coats of white wash on walls surfaces including preparation complete all as specified and directed.
M&L for applying two coats of white wash on walls including preparation of newly plastered surface complete all as specified and directed.
M&L for two coats of distemper oil emulsion on newly plastered surface of walls including corners applying over and including 1-2 mm thick wall care putty over a primer coat to finished surface even & smooth complete all as specified and directed.
M&L for complete removal of existing treatment from walls including corners and applying two coats of distemper oil emulsion over and including 1-2 mm thick wall care putty over a primer coat, finished the surface even & smooth complete all as specified and directed.
M&L for newly plastered surface of walls including cornices and applying two coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over applying of 1-2 mm thick wall care putty finish wall surface even & smooth complete all as specified and directed.
M&L for complete removal of existing treatment of walls including cornices and applying two coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over applying of 1-2 mm thick wall care putty finish wall surface even & smooth all as specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder, light fitting any type and fan regulator etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
M&L for Point wiring for one light/ bell buzzer point, ceiling fan/ exhaust fan point with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and making good to walls,floors etc as per existing one complete all as specified and directed by Engr.-in-charge of following. Note :(1) The wiring to be done as per IE rule and maintain colour code accordingly. (2) moduler switch boxes cover plates shall be paid separetely under respective items.
All as per item No.25 above but for one pin 5 A socket outlet independent point
All as per item No.25 above but for one pin 5 A socket outlet on same board
All as per item No.25 above but with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board
M & L for point wiring complete with PVC insulated and unsheathed, Flame retardant low smoke ( FRLS ) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core , drawing through exisitng conduit (without socket, elbow, junction box, bell mouth, bend, reducer and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly complete all as specified including lugs required for One light/fan point controlled by one switch , complete all as specified and directed. (Note - Modular switch boxes and cover plates shall be measured and paid separately).
All as per item No.29 above but for one pin 5 A socket outlet independent point
All as per item No.29 above but for one pin 5 A socket outlet on same board
All as per item No.29 above but with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board
M&L rigid PVC concealed conduit not less than 20 mm dia including chases cutting and incl making good for drawing of Telephone cable/Cable for TV (VGI Cable )/Inernet Cable all as specified and directed.
S&F in repair ceiling rose surface bakelite 3 terminals of size 65x25mm. complete .
S&F switch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
S&F Socket modular 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and as directed
S&F Socket 6A/16 Amps-2/3 pin combined AC 230 Volts modular type complete all as specified and as directed.
S&F Switch modular type AC 230 volts 16 Amps one way complete all as specified & as directed.
S & F Modular Fan Regulator electronic rotary,0-4 steps, 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F moduler bell push 6 Amp one module one way complete all as specified.
S&F moduler TV Socket out let with single port complete all as specified.
S&F moduler RJ11 Tele Jack double port with shutter port complete all as specified.
S&F Calling Bell (Pilot Ding Dong - 1, Rose Mary Ding Dong -1, City Ding Dong -1, Cindrella Ding Dong-1) complete all as specified.
S&F in repair GI sunken box with flush metal GI box 1 module suitable for modular switches incl plastering, making good disturbed surfaces of wall, painting to match the existing finishes complete all as directed.
All as per item no 44 here in above but 2 module.
All as per item no 44 here in above but 3 module.
All as per item no 44 here in above but 4 module.
All as per item no 44 here in above but 6 module.
All as per item no 44 here in above but 8 module.
S&F combind cover plate white 1 module suitable for modular switches complete all as specified and directed.
All as per item no 50 here in above but 2 module
All as per item no 50 here in above but 3 module
All as per item no 50 here in above but 4 module
All as per item no 50 here in above but 6 module
All as per item no 50 here in above but 8 module
Taking down light fitting care carefully from the wall/ceiling and depositing in MES store and refixing the same at the position as directed after necessary cleaning and maintenance including necessary connecting wire, clip etc all as specified and directed.
S&F LED tube light alluminium extruded body with intergrated electronic driver , 20 W complete all as specified and directed. Make - Philips Cat No BN 021 LED40S- 6500 PSU GR (4 ft) or equivalent of Crompton/ Havells/ Wipro.
S&F LED Mirror light fitting tube light alluminium extruded body with intergrated electronic driver along with fixture, 10 W complete all as specified and directed. Make - Wipro Model Trim Neo LL20-111-XXX-65NE3 or equivalent of Crompton/ Havells/ Philips.
S&F LED down lighter 2'x2' , 35/36 W complete all as specified. Make - Philips Cat No RC383BLED28S-4000PSUODWH PIR or equivalent of Crompton/ Havells/ Wipro.
S&F LED down lighter consealed ceiling light 12W Sky Spot COB (WW) complete all as specified and directed. Make - Crompton/ Haveels/ Wipro / Philips.
S&F flood light fittings. Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP66 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 82/100/110 watt or higher size LED , Glass cover, fixed on pole duly fixed on angle iron bracket complete all as specified and directed. Make Philips BVP192 LED82 CW HO NB FG GR PSU or equivalent of Crompton/ Havells/ Wipro.
Taking down ceiling fan/ wall mounted fan carefully from the wall/ceiling and depositing in MES store and refixing the same at the position as directed after necessary cleaning and maintenance including necessary connecting wire, clip, screws etc all as specified and directed.
S&F wall mounted fans complete with all accessories ,400 mm . BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , connector block of fan including fixing of Fan hooks and necessary nuts and bolts complete all as specified and directed. Make - Usha/ Crompton / Havells.
S&F fans ceiling complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated PVC AC single Phase 230 V / 240V 50 Hz of , connecting up ceiling rose to connector block of fan including fabricating and fixing of Fan hooks from ceiling truss/angle iron, required length of down rods (As per site requirement) and necessary nuts and bolts complete all as specified and directed. Make - Usha/ Crompton / Havells.
S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metalic exhaust fan complete all as specified and directed. Make - Usha/ Crompton / Havells. (Note:- Old u/s Exhaust fan will be deposited to E/M store yard)
S&F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep,50 Hz with louver of size 300 mm sweep, complete with louvers, shutters and connecting up ceiling rose to connector block of fan including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block including taking down old metalic exhaust fan complete all as specified and directed. Make - Usha/ Crompton / Havells. (Note:- Old u/s Exhaust fan will be deposited to E/M store yard)
S&F Supply and fix Water heater storage type, electric, capacity 35 litres AC single phase 230/ 240 V o and connecting up including making of holes and grouting of nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed. Make Havells Model Monza DX GHWAMGSWH035 or equivalent to Usha/ Crompton / Havells.
Taking down old u/s DB/main switch/Metal clad box of any size complete with MCBs and removing u/s materials out of site
S&F Vertical DB DP 6 way double door with 250 Amp rated bus bar including MCCB, 4 pole, 250 Amp breaking capacity 36 KA with enclosure complete all as specified and as directed. Make Indoasian Part No 810359, MCCB Part No 830082 or equivalent to Havells/ L&T/ ABB.
S & F sheet metal enclosure TPN for DB's when MCB's to be used 8 way with 200 amps bus bar and double door complete all as specified and directed.
S&F Residuel Circuit Breaker (RCOB) for earth leakage, overload & short circuit protection 4 Pole 30 mAof capacity 100 Amps complete all as specified.
S&F Sheet metal enclosure SPN for DB's when MCB's to be used 8 way with 200 amps bus bar double door complete all as specified.
S&F Residuel Circuit Breaker (RCOB) for earth leakage, overload & short circuit protection 2 pole 30 mAof capacity 25 Amps complete all as specified.
S & F MCB TPN 100 Amps,240 Volts,10 KA 'C' series with all incoming/outgoing connections with proper size of lugs complete all as specified and directed.
S & F MCB SPN 32 Amps,240 Volts,10 KA 'C' series with all incoming/outgoing connections with proper size of lugs complete all as specified and directed. Make Indoasian Part No 810014 or equivalent Crompton/L&T/Anchor/Legrand
S&F MCB SP 6 to 32A complete all as specified.
M&L for submain wiring with 3 runs(1 run for Phase+1 run for Neutral &1 run for Earth, with approved colour code as per EI rules) of 4 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through and including concealed wiring with PVC conduit pipe of medium duty not less than 15 mm dia including necessary conduit specials and connecting with suitable size thimble, and making good surface of disturbed wall/ceiling/floor as match with existing complete all as specified and directed. Note:-3 runs of 4 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length.
All as per item No 77 here in above, but 3 run of 6 Sq mm. Note:-3 runs of 6 Sqmm size PVC copper cable, and one run of PVC conduit shall be measured as one unit length complete all as specified.
All as per item No 77 here in above, but 6 run of 6 Sq mm (3run -Phase, 1 for Neutral & 2 Runs for Earth with recommended colours) and drawn through not less tha 32 mm dia PVC conduit . Note:-6 runs of 6 Sqmm size PVC copper cable and one run of PVC conduit shall be measured as one unit length complete all as specified.
S&F Sheet metal enclosures with socket plug top and MCB' SPN enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB complete all as specified.
M&L for copper earthing complete with Copper earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to Copper earth strip 20x3mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 40mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer nuetral/body/ Lt panel etc. and testing on completion, complete all as specified & directed by Engr-in-Charge.
AMAR NATH SHARMA
SARASWATI CONSTRUCTION CO
AASNA URZA INDIA PRIVATE LIMITED
M/S SETHI BROTHERS
M/s Anil Kumar
PAWAN KUMAR
M/s RAM RATAN AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .