Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.4 L+₹66,884.66 (4.55%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹13.4 L
EMD Value
₹33,442
Closing Date
18 Jan 2024, 6:00 pmClosed
Regional Project Director
2nd Floor, Bldg.No.3/253, Near AKG Hospital, Talap, Kannur
Sustainability Support to Honnekatte Berika ,Ammenidika Berika ,Karibail Hossagadde, Kadambar, Budriya WSS in Meenja GP
2024_KRWSA_641951_1
16/KRWSA/KNR/SUS/MEENJA/23-24
Open Tender
Civil Works - Water Works
Item Rate
60 days
Meenja Grama Panchayath Kasaragod District
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
₹33,442
Regional Project Management Unit, KRWSA, Kannur
26 Sept 2024
10 Jan 2024
20 Jan 2024
10 Jan 2024
18 Jan 2024
10 Jan 2024
10 Jan 2024 - 18 Jan 2024
12 Jan 2024
Amount
Honnakattte berika WSS
bore well
od120318/2023_2024 : Drilling Bore Well of size suitable to accommodate well pipe suitable for the size below GL having an average overburden of 10-15 m in all classes of soil and rock including all hire charges and storing of soil and rock samples at various depths, conveying and lowering the casing pipes and jointing, grouting with cement including cost of cement, complete. 150mm<br>
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipes.
100.9.12 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 180 mm nominal outer dia pipes.
100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016.
100.98.228 : Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 180mm Dia.
water meter
od120427/2023_2024 : Providing and fixing 15mm (1/2 inch) Class B multijet water meter ,FRP chamber box,and GM ball valve and specials in the existing house connection and making the loop for fixing the water meter-tracing,locating and exposing the service line at the required place including trenching ,cutting and removing the service line portion and making the connection functional including cost of materials, hire for tools, cost of consumables and labour charges etc complete.
pump set and accessories
AMMENIDIKA BERIKA WSS
GI pipe relacing to HDPE
100.9.7 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 75 mm nominal outer dia pipes.
Suuplying HDPE pipe
100.98.133 : Supply of PE Pipe, PE100, PN8, 75mm dia, conforming to IS 4984/2016.
Demolishing existing tank cover
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
Rcc Wall & Roof slab
5.7 : Reinforced cement concrete work in well - steining excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)
Shuttering & centering work
4.3.3 : Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts
KARIBAIL HOSSAGADDE WSS
bore well
od124890/2023_2024 : Drilling Bore Well of size suitable to accommodate well pipe suitable for the size below GL having an average overburden of 10-15 m in all classes of soil and rock including all hire charges and storing of soil and rock samples at various depths, conveying and lowering the casing pipes and jointing, grouting with cement including cost of cement, complete. 150mm<br>
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipes.
100.9.12 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 180 mm nominal outer dia pipes.
100.98.152 : Supply of PE Pipe, PE100, PN10, 63mm dia, conforming to IS 4984/2016.
100.98.228 : Supply of uPVC Pipe, IS 4985: 2000 , 8kg/cm2, 180mm Dia.
pump set and accessories
od124891/2023_2024 : Supplying and Installation of best quality submerssible pumpset and accessories with ISI mark (IS 14220) as per duty conditions.
water meter
od124892/2023_2024 : Providing and fixing 15mm (1/2 inch) Class B multijet water meter ,FRP chamber box,and GM ball valve and specials in the existing house connection and making the loop for fixing the water meter-tracing,locating and exposing the service line at the required place including trenching ,cutting and removing the service line portion and making the connection functional including cost of materials, hire for tools, cost of consumables and labour charges etc complete.
Kadambar WSS
Ladder for existing tank
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
100.47.1.1 : Leak rectification work in 32 mm PVC (Class 2 to 6) pipe line including detecting and locating leak, earth work excavation in all kinds of soil for for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipe line with out causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe in to the trenches,placing in position aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or or any available joint and testing the pipe line by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards,lighting,watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers including the cost of pipe and PVC specials; PVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
Budriya WSS
Ladder for existing tank
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
PVC PIPE
100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.
100.9.3 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 32 mm nominal outer dia pipes.
100.98.233 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50mm Dia.
100.98.231 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 32mm Dia.
2.1.1 : Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
RONY D SOUZA
Bidder Name
RONY D SOUZA
NAZIR I
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_979788.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .