| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | ₹38.8 L Quoted ₹39.0 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹43.3 L+₹4.3 L (11.2%)Rejected-AOC | ₹43.3 L+₹4.3 L (11.2%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹43.7 L+₹4.7 L (12.1%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹43.7 L+₹4.7 L (12.1%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹43.7 L+₹4.8 L (12.3%)Rejected-AOC | ₹43.7 L+₹4.8 L (12.3%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 5 | L5₹44.1 L+₹5.2 L (13.2%)Rejected-AOC | ₹44.1 L+₹5.2 L (13.2%) | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
27 Aug 2022, 6:00 pmClosed
GE I RNDDEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF BOUNDARY WALL, HARD STANDING AND SHED FOR CAR PARKING NEAR TECH AREA B AT IRDE UNDER GE (I) RND DEHRADUN
2022_MES_543941_1
GE(I)RND/9168/E8/22-23
Open Tender
Civil Works
Item Rate
180 days
DEAL DEHRADUN
Class D Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹94,000
Yes
12 Sept 2022
6 Aug 2022
29 Aug 2022
6 Aug 2022
27 Aug 2022
20 Aug 2022
6 Aug 2022 - 20 Aug 2022
Amount
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L forHard core of broken stone gauge not exceeding 63mm, deposited, spread and levelled in layer not exceeding 15 cm thick watered & rammed to a true surface complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
M&L for Rubberised polished precast coloured cement concrete Interlocking paver block glossy finish any shape and size confirming to IS 15658-2006 of 100 mm thickness M-40 grade complete with & including 50mm thick sand cushioning layer complete, all as specified and directed.
S&F mild steel work in tubular trusses complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 and complete all as specified
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed..
Removing surplus excavated soil to a distance excedding 1.5 km but not exceeding 5km & depositing where directed at a level n.exc 1.5 metre above the starting point complete all as specified and directed.
M&L for Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
S&F M.S work as in hand rail or other stock section or core for wooden dand rail straight portion, drilled and countersunk for baluster running bar for doors balusters nosing to steps including embedding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc, flat iron fillets (fo securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work confirming to FC 290 or E-165 complete all as specified and directed
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 410(Gde E-250)
M & L for excavating hard/dense soil in post holes (or similar holes) each n exc 0.5 cum , getting out , returning , filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering , and removing surplus soil to a distance n exc 50 m and making good surfaces.
M&L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation filling, mass concrete and sub base of floor etc complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n' exc. 1.5 m in depth and getting out in any type soil complete all as specified and directed.
M&F for brick work with fly ash of old size bricks in straight or curved on plan exc. 6 M mean radius built in CM 1:6 complete all as specified and directed
M& L for Rendering 15mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed
Preparation of new plastered surfaces of wall / ceiling and applying two coats of cement base paint complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
M&L for RCC M -25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, including rafts, footing, foundation beams, plinth beams, bases for columns etc, basement slab, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC M -25 (Design Mix) , type B-1using 20mm graded crushed stone aggregate as in beams, cantilever bressummers lintel over 1.5 m span etc complete all as specified and directed.
M&L for use & waste for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter including fair finished surfaces complete all as specified and directed.
M&L for use and waste of formwork to sides and soffits of floors or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports etc. and similar work of fair finished flat surface of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, coping, benching, kneelers, apex stone, bed plates, kerbs, etc. including weathering, slightly rounded or chamfered angles and throating, including necessary from work etc complete all as directed.
M&L galavanised 2 stand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and strainings and fixing to any type of standard rails straining bolts ,including securing or tying at crossing with and provision of galvanised mid steel wire, staples or steel pins, etc. including restraining & resecuring & including making good staples etc ( each line to be measured )
S&F 110mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to walls fixed on wall or floor including all fittings complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Demolition of brick or stone masonary built in cement mortar including pre cast articles complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including in PVC conduit ISI marked not less than 20mm dia, surface conduit wiring in steel/PVC/Wooden panelling wall/ceiling and concealed in hardstanding/Brick/RCC wall with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for controlled by MCB. Note for item 29 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia in stove enamelled steel conduit (v) Make of cable : Gloster/Havells/ Poly cab as approved by GE. (vi) Make of in stove enamelled steel conduit& fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga/ISI as approved by GE.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F LED 20 W Tubelight fitting made up of polycarbonate material complete all as specified and directed. Make: LCTLN-20-CDL of C&G or euivalent in Philips/Havells/CG
M&L sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed in PVC conduit of suitable dia not less than 25 mm dia,in hardstanding/Brick/RCC wall and surface in steel/PVC/Wooden panelling wall /ceiling with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor complete all as specified and directed. Notes for item No. 32 (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Gloster /Havells/Polycab approved by GE. (iv) Make of conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga/ISI as approved by GE.
S&F sheet metal enclosure for double door distribution board SPN (when MCB’s to be used) 8 way, 240V,100 Amps rated bus bars and with neutral, Earthing bar and din rail complete, all as specified and as directed. Make: Indoasian/Havells/L&T Note: Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing
S & F MCB SPN 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811151/24/26/27/28/29 or equivalent in Havells/L&T as approved.
S & F MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Havells/L&T as approved.
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to GI earth wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Amit Associates
M/S PUNDIR BUILDERS
M/s Arora Sales Corporation
M/s RAM RATAN AND SONS
Sharda Enterprises
UNOQ Private Limied
M/S Anil kumar
sidh builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .