| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹34.0 L+₹1.7 L (5.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.2 L+₹1.9 L (5.86%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.0 L+₹2.6 L (8.18%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹36.4 L+₹4.1 L (12.6%)Rejected-Finance MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2022_MES_555001_1
8155_GE_NW
Open Tender
Civil Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,800
Yes
27 Feb 2023
29 Sept 2022
19 Oct 2022
29 Sept 2022
17 Oct 2022
12 Oct 2022
29 Sept 2022 - 17 Oct 2022
60 days
Amount
Taking down Copper /aluminium point wiring (light ,fan ,socket ,bell, power point ) complete fitting such as switches ,ceiling roses ,pendants,regulators,sockets ,light fitting any type, building security light removing materials to store for keeping in safe custody for taking credit to match with existing surface complete all as specified and directed.
M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade ISI marked with valid CML No. single core multistranded cable in and including medium grade concealed PVC casing and caping not less than 20mm dia and accessories ISI marked with valid CML No. (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and including 1.6 mm thick MS sheet/ pressed steel sunken boxes (earth dolly) duly painted with two coats of anti corrosive paint / aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paints over a coat of red oxide primer externally covered with 3 mm thick plastic laminated sheet cover for fixing of switches sockets and fan regulators etc including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light point controlled by one switch, complete all as specified and as directed.
All as per item No 2 here-in-before but for one fan point controlled by one push button on independent board.
All as per item No 2 here-in-before but for one bell point controlled by one push button on independent board.
All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board.
All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on same board.
All as per item No 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board complete all as specified.
Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 8 here-in-before but for one fan point controlled by one push button on independent board.
All as per item No 8 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No 8 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No 8 here in before but for one 5 pin 5 Amp socket outlet point on the same board complete all as specified and directed.
All as per item No 8 here in before but using with 2.5 Sqmm copper conductor cables multistranded (FRLSH) PVC insulated , unsheated cable and including 2.5 Sqmm copper conductor cable multistranded(FRLSH) PVC insulated and unsheated cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S&F bell push flush type 5 Amps single pole complete all as specified and as directed
S&F electric bell, AC 230 Volt single pole complete all as specified and as directed
S&F switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S&F switch piano flush type single pole one way 15 Amp complete all as specified and as directed .
S&F switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed.
S&F in repair socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S&F ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
S&F in repair , bell push flush type 5 Amps single pole complete all as specified and as directed
S&F in repair , electric bell, AC 230 Volt single pole complete all as specified and as directed
S&F in repair , switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S&F in repair , switch piano flush type single pole one way 15 Amp complete all as specified and as directed .
S&F in repair , socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repair socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repair , switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed.
S&F in repair , switch socket combination multipurpose 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified and directed
S&F in repair , fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S&F in repair , capacitor for ceiling fans,230 volts, 2.5 MFD including necessary soldering complete all as specified and as directed
S&F in repair , capacitor for any type of exhaust fan/pedestal fan/air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD complete all as specified and directed.
S&F in repair , lamp holder ,PVC /poly carbonate type with back plate suitable for batten fittings , all as specified and directed
S&F in repair , ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
M&L in repair sub main wiring on wall/ceiling with 4 runs of 10sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including PVC casing & capping with all accessories such as Tees, elbows, junction box etc.as required of not less than 20 mm dia and 1 run of 10 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLSH cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing finish complete all as specified and as directed. Note : 5 runs of 10 Sqmm cable and one run of PVC casing and capping with accessories shall be measured as one unit.
All as per item No 35 here-in-before but 2 runs of 4 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and directed. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
All as per item No 35 here-in-before but 2 runs of 6 sqmm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and directed. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
S&F Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.
S&F Sheet Metal Enclosure for MCB DB, TPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F i Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
S&F i Sheet Metal Enclosure for MCB DB, SPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair , MCB, TPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.
S&F in repair , MCB, TPN, 32 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.
S&F in repair MCB, SPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.
S&F in repair MCB, SP, 6-32 Amps, 240 Volt, b curve, having breaking capacity 10 KA complete all as specified and as directed.
S&F in repair MCB, SPN, 6-32 Amps, 240 Volt, b curve, having breaking capacity 10 kA complete all as specified and as directed.
S&F in repair 20 watt LED tube double side with batten ,universal type , 230V,50 Hz,wall surface ,roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make:- Cat part no -,CRYSTAL1213T8DSTL20WLED865S GLASS(Tube) and REGALBATTENT8UPTO1X22WSSBSWH (Batten) of Havells or equivalent model of other approved manufacturers from the list.
S&F in repair LED glass T8 tube 20 watt, 220 volt ,50 Hz, LED tube rod, double side connection, inbuilt driver complete all as specified and as directed. Make:- Cat part no -CRYSTAL1213T8DSTL20WLED865SGLASS of havells or equivalent model of other approved manufacturers from the list.
S&F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,environmental friendly ,energy efficient , with all connecting accessories ,with suitable connection complete all as specified. Make:- cat part no- LUMILINEBS20WLED830SPCWH of havells or equivalent model of other approved manufacturers from the list.
S&F in repair LED light fitting 10 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified. Make:- cat part no-LUMILINEBS10WLED865SPCWH of Havells or equivalent model of other approved manufacturers from the list.
S&F in repair ceiling light driver up to 6 Watt with all accessories and connection to the electric circuit complete all as specified and as directed.
S&F in repair ceiling light driver 9 to 12 Watt with all accessories and connection to the electric circuit complete all as specified and as directed.
S&F in repair ceiling light driver 15 to 18 Watt with all accessories and connection to the electric circuit complete all as specified and as directed.
S&F in repair 15 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified cat part no - LSCSM-15W-CDL of crompton or equivalent model of other approved manufacturers from the list.
S&F in repair 12 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified cat part no - LSCSM-12W-CDL of crompton or equivalent model of other approved manufacturers from the list.
S&F in repair 15 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified. Make:- Cat part no -LSCRM-15W-CDL of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair 12 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified. Make:-cat part no - LSCRM-15W-CDL of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair 12 Watt surface mounted round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified. Make:- cat part no - LCDSPLN-R-12-CDL of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair dimmable cob light 7 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified Make:- cat part no - LCOBD07 of Luker or equivalent model of other approved manufacturers from the list.
S&F in repair dimmable cob light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified. Make:- cat part no - LCOBD12 of Luker or equivalent model of other approved manufacturers from the list.
S&F in repair Ceiling light in Dome series 18 watt round 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified. Make:-cat part no - LCL18R of Luker or equivalent model of other approved manufacturers from the list.
S&F in repair indoor wall mounted light 12 watt ,140 volt to 265 volts,IP-20 ,50 Hz ,aluminium housing with all accessories and connection to the electric circuit complete all as specified and directed Make:- cat part no -LWL105 of luker or equivalent model of other approved manufacturers from the list.
S&F in repair mirror light 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified. Make:-cat part no - LMCL18 of Luker or equivalent model of other approved manufacturers from the list.
S&F in repair mirror light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified. Make:- cat part no - LMCL12 of Luker or equivalent model of other approved manufacturers from the list.
S&F in repair Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and as directed.
S&F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 2' long, suitable for ceiling fans any type, any make, any size complete all as specified and as directed.
All as per item No 68 here-in-before but 3' long complete all as specified and as directed.
All as per item No 68 here-in-before but 5' long complete all as specified and as directed.
S& F replacement copper conductor multistranded cable flexible 03 core PVC insulated of size 40/0.076 at site/MES store yard complete all as specified and directed.
S&F in repair Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size all as directed.
S&F in repair Rubber reel insulator, suitable for ceiling fans any type, any make, any size all as directed.
M & L in repair for hanging hook for ceiling fan with nuts bolts and washer min thickness 5 mm all as specified and directed by engineer in charge
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No. complete all as specified and as directed.
All as per item No 75 here-in-before but exhaust fan of 450/300/250 mm sweep complete all as specified and as directed.
All as per item No 75 here-in-before but wall mounted fan of 400 /450 mm sweep complete all as specified and as directed.
All as per item No 75 here-in-before but pedestal fans 600 /400 mm sweep complete all as specified and as directed.
All as per item No 75 here-in-before above but industrial air circulator fans of any sizes complete all as specified and directed
M & L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10mm c/c , 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
M&L in repair earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. point 3 connected to earthing test point all as specified or indicated including testing on completion including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10mm c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S&F in repair Modular Bell push 6A, 1module, complete all as specified.
S&F in repair in repair Fan Regulator, modular electronic rotary, 0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified
S&F in repair switch modular 6 Amps 240 Volts one way switch complete all as specified.
S&F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.
S&F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified. Make -Legrand,havells ,Honeywell.
S&F in repair Switch modular type AC 240 volts 16 Amps one way complete all as specified.
S&F in repair sunken box with Modular white cover plate 2 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S&F in repair sunken box with Modular white cover plate 3 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S&F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S&F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S&F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20-32 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20-32 Amps having breaking capacity 10 kA, including taking down old unserviceable earth plug complete all as specified.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm 2 core including taking down old unserviceable cable complete all as specified.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm 4 core including taking down old unserviceable cable complete all as specified.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core including taking down old unserviceable cable complete all as specified.
S&F in repair circular highbay LED light 80 Watt ,240 volt , min lumens 110 Lm/w ,IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make:- Cat part no -LHB11-80-CDL/60-M of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair LED Flood Light 50 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power ,with driver ,complete all as specified. Make:- Cat part no-CFS-504-50-30-60D-SL-GL-NSG of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair LED Flood Light 70 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminous efficiency and high power with driver complete all as specified. Make:- Cat part no-LFL-70-CDL/60-M of Crompton or equivalent model of other approved manufacturers from the list.
S&F in repair LED building security light 35 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified. Make:- Cat part no. ENDCITYLITPLAT+SL35WLED757 SASYBOPCWOSPD of Havells or equivalent model of other approved manufacturers from the list.
S&F in repair LED building security light 40 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified. Make:- Cat part no-ENDCITYLITEPLAT+SL40WLED757 PASYBOPCWOSPD of Havells or equivalent model of other approved manufacturers from the list.
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at 'A' & 'B' area at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days all as specified and directed by Engineer-in-Charge.
Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation) like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at 'A' & 'B' area at Naval base during off days including sunday and holiday days all as specified and directed by Engineer-in-Charge.
NOTE foe item no. 102 & 103:- (i) The material and labour cost required for taking down existing fitting / fixture and fixing of new item shall be measured and paid separately under relevant item. Additional labour charge required for immediate attendance of complaint only shall be quoted under this item. (ii)The technician employed by the contractor shall available on all working days. The quoted rate shall inclusive of all labour, transportation of material and tools. (iii) The contractor shall display contact number of technicians in 'B & J' area at Naval Base to register users complaint. (iv) A penal recovery of Rs. 800/hour/complaint shall be effected on contractor beyond 3 hrs. A register shall be maintained by contractor duly countersigned by Concerned JE & AGE with time of occurrence of defect and time of rectification and submitted for claiming payment.. (v) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly including all aspects like labours ,tool, transportation etc. (vi) The contractor should display contact number at complaint cell to register users complaint. vii) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. Including in all aspects like labours,tool,transportation etc.
M&L for checking of ceiling fan stability / tightness with fan hook for complete Satellite area as directed and make good, re-tightening of split pin / nut, bolt etc, ,loose connection in distribution boards, MCBs in quarters all as per site requirement complete all as specified and as directed. Note:- (i) The cost of accessories like split pin, nuts, bolts, washers etc if any required shall be included in the quoted rate. The quoted rate shall inclusive of all labour and plants like ladder etc complete. (ii) The contractor shall maintain a register showing the location of fan duly signed by the users for the service carried out. This register shall be produced while claiming payment. (iii) The checking of fans shall be carried out once in 6 months. (iv) Checking of all fans and DBs in a qtr at a time shall be considered as one job
M&L for checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in distribution boards, MCBs in 'A' and 'B' Area at Naval base all as specified and directed by engineer in charge Note - (i) The cost of accessories like split pin, nuts, bolts, washers etc if any required shall be included in the quoted rate. The quoted rate shall inclusive of all labour and plants like ladder etc complete. (ii) The contractor should prepared a register and enter office name with signature of office in charge and submitted to engineer in charge for verification. (iii) Checking of 7 fans and 2 DBs of any type at a time is shall be considered as one job
M&L for checking of faulty / jumped energy meter (three phase /single phase ) by fixing new energy meter supplied by department in series with existing meter and submit meter reading report of both energy meter after one week to find out the fault in meter if any to the in engr-in -charge complete all as specified and as directed.
M&L in repair aluminium strip 25 x 3.15 mm with porcelain insulators, saddles and fixing screws etc for roof conductor and down conductor above ground all as specified and directed.
M&L in repair 20 X 3.15 mm Copper strip with saddles and screws etc complete all as specified and directed .
M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified.
M&L for Checking of earthing resistance and E-N voltage with calibrated earth tester meter and multimeter including recharging of conventional earthing of lightening arrestor of building /workshop/hanger /OTM etc at Naval Base Kochi complete with chemical, maintaining the earth testing record, rectification of earthing related fault all as directed by Engineer in charge. Note:- A record for checking and recharging shall be maintained duly signed by user and JE E/M .
M&L in repair galvanised steel strip 32mmx6mm complete with, protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg complete all as specified and as directed.
M&L in repair galvanised steel strip 25mmx4mm complete with, protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg. complete all as specified and as directed.
M&L in repair of earthing chamber of any type any size with necessary pack work required with smooth surface duly coloured after repair work and cover of the size of the earth pit complete all as specified and directed.
S&F in repair 4mm dia galvanised iron or steel wire buried in ground fixed on walls and connected to main earth strip including excavation and earth work ,refilling etc. compete all as specified and as directed.
S&F in repair for rigid non metallic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends, fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia. ISI Marked complete all as specified and as directed.
Supply & fix in repair recess mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , all as specified and directed. Make:- cat part no -LCTRH-36-CDL of Crompton or equivalent model of other approved manufacturers from the list.
Supply & fix in repair recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , all as specified and directed Make:- Cat part no -LCTRNE-36-FO-CDL of crompton or equivalent model of other approved manufacturers from the list.
S&F in repair MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed by engineer in charge .
S&F in repair MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA complete all as specified and directed by engineer in charge
S&F in repair MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA all as specified and directed by Engineer in Charge.
S&F in repair MCCBs FP 200 Amps thermal magnetic 25 kA complete all as specified and directed by Engineer in Charge.
S&F in repair bed side Lamp 3 watt 50 hz,230 volts,3000k with all accessories and connection to the electric circuit. complete all as specified. Make:- cat part no -48042/30/31 of Philips or equivalent model of other approved manufacturers from the list.
S&F in repair Suspended LED lighting solution with 52 mm width and 75 mm height 24 watt 230V,50 Hz, including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make :- CG cat part no -CCP-121-24-40-SL-NWH of Havells or equivalent model of other approved manufacturers from the list.
Supply and Fixing in repair pic ventilation fan high speed 250 mm ,pic body ,dust protection ,50 watt ,speed 2370 Rpm ,Air delivery 460 cum/Min ,light weight including suitable connection from ceiling rose all as specified and directed . Make:- cat part no -Brisk air 10 inch of Crompton or equivalent model of other approved manufacturers from the list.
Supply and Fixing in repair pic ventilation fan high speed 200 mm ,pic body ,dust protection ,50 watt ,speed 2370 Rpm ,Air delivery 460 cum/Min ,light weight including suitable connection from ceiling rose all as specified and directed . Make:- cat part no -Brisk air 8 inch of Crompton or equivalent model of other approved manufacturers from the list.
Supply and Fixing in repair metallic ventilation fan high speed 300 mm ,metallic body ,70 watt ,speed 1380 Rpm ,Air delivery 1600 cum/Min ,220-240 volts ,50 Hz , including suitable connection from ceiling rose all as specified and directed . Make:- cat part no -Trans air 12 inch of Crompton or equivalent model of other approved manufacturers from the list.
Supply and Fixing in repair metallic ventilation fan high speed 225 mm ,metallic body ,40 watt ,speed 1380 Rpm ,220-240 volts ,50 Hz , including suitable connection from ceiling rose all as specified and directed . Make:- cat part no -Trans air 9 inch of Crompton or equivalent model of other approved manufacturers from the list.
Supply and Fixing in repair ceiling fan 1200 mm sweep ,white colour ,50 watt,,220-240 volts ,50 Hz ,ISI marked including suitable connection from ceiling rose all as specified and directed .Make:- cat part no Empower 50 of Crompton or equivalent model of other approved manufacturers from the list.
N.O. Antony Contractors
ANIE JOHN CONTRACTORS
ST ANTONY CONSTRUCTIONS
Oriental Constructions
MS BUILDERS
PADMADEV CONSTRUCTIONS
Neptune Engineers and Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .