Bilwal Masulbhai Titabhai
Providing & fixing paver block, parking shed, sewage treatment plant (100 KLD) Video conference room at Rajpipla district jail, Rajpipla dist. Narmada (Including Electrification) [3rd Attempt]
266742
NIT No 22 [2025-26] Sr No 04
Open
Civil Works
Works
Vadodara
13 documents required · 8 mandatory · 5 optional
₹3,600
Yes
GUJARAT STATE POLICE HOUSING CORPORATION LIMITED
₹1.1 L
Yes
20 Jan 2026
20 Jan 2026
20 Jan 2026
2 Feb 2026
20 Jan 2026
No. InFigure In Words Rs.
Excavation for foundation in Loose or soft soil upto 1.5 mt. depth including sorting out and
stacking of useful materials and disposing of the excavated stuff upto any Lead & Lift. Rs. One Hundred Twenty Four &
Paise Sixty One Only
Excavation for foundation in Dense or Hard soil upto 1.5 mt. depth including sorting out and
stacking of useful materials and disposing of the excavated stuff upto any Lead & Lift. Rs. One Hundred Fifty Nine & Paise
Thirty Only
Providing & laying Cement Concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone
aggrigates of 40 mm nominal size) curing complete excluding cost of formwork in Rs. Three Thousand Thirty Three &
FOUNDATION AND PLINTH. Paise Thirty Three Only
Providing & laying Cement Concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone
aggrigates of 20 mm nominal size) curing complete excluding cost of formwork in Rs. Three Thousand Five Hundred
FOUNDATION AND PLINTH. Fifty Five & Paise Sixty Six Only
Providing & laying Cement Concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone
aggrigates of 40 mm nominal size) curing complete excluding cost of formwork in Rs. Two Thousand Seven Hundred
FOUNDATION AND PLINTH. Eleven Only
BRICK WORK using common burnt clay building bricks having crushing strength not less
than 35 Kg./Sq. cm. In Foundation & Plinth in cement mortar 1 : 6 ( 1 cement : 6 coarse sand ( Rs. Four Thousand Two Hundred
Conventional Bricks). Thirty Seven & Paise Sixty Only
FILLING in plinth with SAND under floors including watering, raming consolidating and
Rs. Four Hundred Eighty Four &
7 dressing etc. complete. 16.00 Cum 484.44
Paise Forty Four Only
Providing & laying Controlled CEMENT CONCRETE M-150 and curing complete including
the cost of formwork of Plywood only with fair finish & Proping must be of steel only so as to
give fair finish but excluding the cost of reinforcement in Rcc Grade Slab. Providing and Rs. Three Thousand Eight Hundred
Mixing Plasticiser in cement concrete as per mix design including rate of labour,material etc.as Seven & Paise Six Only
per direction of Engineer in charge.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing & laying Controlled CEMENT CONCRETE M-250 and curing complete including
cost of formwork Plywood only with fair finish & Proping must be of steel only so as to give
fair finish but excluding the cost of reinforcement in column FOOTING base of columns and
Rs. Four Thousand Five Hundred
9 Mass concrete. Providing and Mixing Plasticiser in cement concrete as per mix design 4.00 Cum 4522.02
Twenty Two & Paise Two Only
including rate of labour,material etc.
Providing & laying Controlled CEMENT CONCRETE M-250 and curing complete including
cost of formworkof Plywood only with fair finish & Proping must be of steel only so as to give
fair finish but excluding the cost of reinforcement in COLUMN upto PLINTH for any cross
Rs. Eight Thousand Eight Hundred
10 sectional area of column. Rate are also inclusive of providing and mixing Plasticiser in cement 4.00 Cum 8893.05
Ninety Three & Paise Five Only
concrete as per mix design etc.
Providing and laying Controlled cement concrete M-250 and finishing smooth with curing
etc.. complete including the cost of formworkof Plywood only with fair finish & Proping must
be of steel only so as to give fair finish but exculding the cost of reinforcement for PLINTH Rs. Seven Thousand One Hundred
11 BEAMS of any cross sectional area of beam. Rate are also inclusive of providing and mixing 3.00 Cum 7169.87 Sixty Nine & Paise Eighty Seven
Plasticiser in cement concrete as per mix design etc. Only
Filling avaliable excavated earth ( excluding rock) in trenches, plinth sides of foundations etc.
in layers not exceeding 20cms. in depth consolidating each deposited layer by ramming and Rs. One Hundred Thirty Six & Paise
watering. Eleven Only
Providing TMT Bars Fe500D reinforcement of approved brand of GSPHC ONLY for RCC
work including cutting, bending, binding and placing in position etc.complete for all floors. Rs. Seventy Six & Paise Fifty Two
Providing , Fabricating and fixing M.S. GRILL/GATE of approved pattern fabricated from
M.S. flat,square bars, round bars,c-channel, box pipe as per detail Drawings. Rate is including
welding. Rate is also including two coats of Oil paint and one coat of yellow Zinc Cromet
Rs. Seventy Five & Paise Twenty
14 primer coat of approved brand only oil paint shall be used as per approval materials list of 22993.00 Kg. 75.20
GSPHCL Steel Used Must Be ISI Make List.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
providing and corrogulated JSW pre coated sheet roofing fixed withh galvanised iron J or L
hooks, bolts and Nuts 8 mm dia with bitumin and G.I. Limpet washer or G.I. limpet washer
Rs. Nine Hundred Eighty Four &
15 with white lead complete excluding the cost of Purlines , rafters and trusses(0.60mm thick) 300.00 Sqm 984.37
Paise Thirty Seven Only
Providing and Laying 60mm thick Rubber Mould Paver block of M-30 grade made by Block
making machine with strong vibratory compaction and of approved size and design in
required colour and pattern over and including 50mm thick compacted bed of course sand etc. Rs. Six Hundred Ninety Eight &
complete as directed by engineer in charge Paise Ninety Six Only
17 Designing (hydraulic, process. structural & aesthetic), providing, construction, hydraulic
testing,commissioning of Sewage Treatment Plant of Capacity 100000 ltr per day (100 KLD)
and giving satisfactorily trial run for 3 months of STP consisting of inlet Chamber, Screen
chamber, Grit Separator, MBBR (Based on technologies providing attached growth on plastic
media kept suspended in the sewage due to low density of plastic & provided with diffused air
for aeration with tank, Secondary Clarifier, Sludge collection sump, Gravity Sludge Thickener,
Chlorine Contact Tank, Chlorinator room, Sludge Dewatering Equipment,associated piping
work with required valves, gates, drains. Administration Block cum Laboratory, associated
buldings, Laboratory Equipments, inclusive of mandatory spare parts and instrumentation, etc
complete as turnkey jobs with all involved , electrical, instrumentation and mechanical works
inclusive of following items, units as per detailed specifications for civil, electrical,
instrumentation and mechanical components with all duties and taxes etc. commplete to Rs.Fifty four lakh fifty three
achieve BOD<10ppm,TSS< 10ppm, Biological TN < 10ppm & PO4 < 2ppm to get recyclable thousand three hundred
quality of water for industrial/agricultural purposes. The Coagulant Desing System is
mandatory for chemical phosphorus removal..If so required for the complete working of the
STP and have it approved by GSPHCL.All the materials & componant of STP Shell be of
approved brand & make by GSPHCL Only.
Min. freeboard of 0.3m shall be maintained unless otherwise asked for 0.5m stipulated for
specific units.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
A PRIMARY TREATMENT
1.1 Bar screen Chamber : Supply, installation, testing & commissioning of 2 Nos. SS-304
Perforated, Screens with suitable lifting arrangement to be fitted with in Bar Screen Chamber
as per STP Manufacturer's design.
1.2 Oil & grease Chamber : Supply, installation, testing & commissioning of Manual
overflow type Oil Removal trap for removal of Oil & Grease from Chamber.
1.3 Collection cum Equilization tank: Tank will be in RCC _ Civil Contractor Scope and the
tank shall have Retention time of Minimum 8 Hours. Course Bubble aeration will be provided
in the tanks.Design included and to be approved by department GSPHC.
1.4 Raw Sewage Transfer Pump :Supply, installation, testing & commissioning of non-clogging
submersible pumps complete with all accessories, motor of required capacity. Delivery
header with check valve, level controller (with wiring) to control the level of sump
automatically.
No. of pumps: 02 Nos. (1 Working + 1 Standby).
B SECONDARY TREATMENT
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
2.1 Process Tanks : Material of construction shall be in MS + FRP : MS sheet thickness 6.0 mm
and Internal FRP lining shall be 2.0 mm. Outside Epoxy Painted.
2.1.1. Anoxic Tank : As per STP Manufacturer's design
2.1.2. Aeration Tank : Aeration Tank shall have suitatble MBBR Media As per STP
Manufacturer's design. Fine Bubble aeration shall be provided with Air Blower (No of Blowers
: 1 Working + 1 Standby)
2.1.3 Tube Settler \ Lamella Settler : Tank with Tube Deck media \ Lamella Plates and
Recirculation Pumps (No. of pumps: 02 Nos. (1 Working + 1 Standby)) As per STP
Manufacturer's design.
2.1.4 Chlorine Contact tank: As per STP Manufacturer's design. Chlorine dosing shall be
provided with tanks and dosing Pumps (No of Pump : 01 No and No of Tank : 01) for
disinfection Purpose.
2.1.5 Sludge Holding Tank: Tank As per STP Manufacturer's Design. Filter press of suitable
capacity along with Feed Pump ((No. of pumps: 02 Nos. (1 Working + 1 Standby)) as per STP
Manufacturer's design.
C TERTIARY TREATMENT
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
3.1 Filter Feed Pump : Supply, installation, testing & commissioning of pumps complete with
all accessories, motor of required capacity. Delivery header with check valve, level controller
(with wiring) to control the level of sump automatically. No. of pumps: 02 Nos. (1 Working +
1 Standby).
3.2 Multigrade Filter: Supply, installation, testing & commissioning of Filter complete
with all accessories, Isolation Valves, Vessel media and Piping
3.3 Activated Carbon Filter: Supply, installation, testing & commissioning of Filter
complete with all accessories, Isolation Valves, Vessel media and Piping
3.4 Treated Water tank: Tank will be in RCC _ Civil Contractor Scope and the tank shall have
Retention time of Minimum 8 Hours. Design of tank is included which to be approved from
GSPHC Structure department.
D 4.0 Control Panel for Sewage Treatment Plant & Cabling Work :
4.1Supply ,Installation ,Installation & Commissioning of Common control panel
(compartmental type) and Cabling for all electrical items like sewage transfer pumps, air
blowers, filter feed pumps, sludge removal pump as well as dosing system.(Details
Attached Below)
4.2 SLD & A Drawing of panel shall be approved by Executive Engineer (Ele.)Panel
Manufacture Shall be approved by EIC as per Tender specification and make list
5.0 Inter Connecting Pipe Work within Battery Limit : 01 Set. Sewage Pipe line Shall be UPVC.
Air line shall be MSEP. Submerged air lines shall be in UPVC. Clear Water shall be in UPVC.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
(1) All Civil works finished with water proofing, plaster, Outside & Inside colour as per
GSPHC list, structure duly tested for leak-proofing, plant room flooring, pumps foundations
etc. and related S.S/MS/CI works such as supply and fixing of handrails, manholes, gratings,
grills, doors, vents, footrests etc. shall be in the scope of the Main Civil Contractor.
(2) All Civil Tanks shall be constructed in RCC as per STP manufactures drawing &
STRUCTURAL Design.Design to be approved by structure department of GSPHC
(3) If anything required to achieve the mentioned parameters and completing treatment
process shall be in STP Manufacturer's scope.
B. Chemical & Consumable Charges for Comprehensive (all inclusive) annual maintenance
service contract of the above STP system as per the terms and conditions of the tender, This
shall be applicable after Defect Liability Period of One year. Total -3Yrs.
C. Operation of Sewage Treatment Plant Charges for providing manpower for operation of
STP at site as per the terms and conditions of the tender . The charges shall be
applicable after handing over of the system.Including cost of operater, Periodical
checking of the plant, periodical testing of treated water with submission of reports,
oiling, greasing, routine and preventive maintenance of electrical Items, consumables,
chemicals, disposal of dried sludge as per direction of engineer in charge.
Total Time Period -3 Yrs.
Manpower : 3 Operator (8 Hour shift) and 1 Helper
F Rate include all cost of material,Labour and require machineries involved in the item.In all
operation describe above for complete above item.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
G Estimate offer should be including Collection tank,Treated water tank and all civil work
finished with water proofing ,treatment as require,plastering ,colour work as per
GSPHC,Structure duly tested for leakproofing
,Plant room flooring ,Pump foundation etc.and related S.S/M.S/CI work such All items should
engineer incharge.
H Electrical Supply panel,Power and control cabling.
Electric Control Panel & Cables with automation, audio Visual alarm. (As per Venders design )
A) Power and control cabling between panel and electrical motors, instruments.
All power cables up to 4 mm2 will be of Copper Armoured conductor, whereas above
4 mm2 will be of Aluminium conductor. Perforated metallic Cable tray with supports will
be provided to lay the cables.
B) All instrument cables will be of Copper conductor.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
I (C)SITC of CPRI approved makeI IP 66 with Double door Compartment type Electric control
panel mounted on the Stand for Semi automatic operation of pumps comprising incoming
MCBB, digital VAF meter switches, over load and under voltage protection devices, single
phase preventers, Reverse phase sequence, MCB and DOL /Stat Delta starter for each
motor, indicating Lamp etc, dry suction cut off, all complete. 1 No. Panel
comprising:
• Compartment type, with 2mm sheet metal for Outer body & door & 1.5 MM sheet metal for
partition.
• Cubical type
• Floor mounted with 1.5 feet height supporting legs with necessary foundation as per site
requirment
• Cable bottom/Top entry(As per Site Situation)
• All cables inside the panel will be of Copper conductor.
• Incoming power control switch.
• Ammeters voltmeters Frequency (VAF) phase indicating lamps,
• MCB and starters.
• 2 Nos. automatic level controllers for actuating raw effluent and Filter Feed pumps
J (D) Automation for Pump operation :
System to start manually/automatically at every start, the other pump shall cut in There shall
be audio visual alarm in case any pump/blower fails to starts// trip. Proper name
plates & marking will be provided on the panel doors.
Programmable Control System for the following logic:
i) System to start manually/automatically
ii) At every start, the other pump shall cut in
iii) Audio visual alarm in case any pump/Blower fails to starts.
iv) Both the pumps & Blowers will be in operational but with one remaining standby at any
particular moment.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
K E) Local Push bottom.
F) Armored cabling from our panel to motor starters and earth pits (in civil).
G) Necessary earthing chamber(Civil Job)
H) Earthing to panel connectivity to 25 x 6 mm GI patti & Panel to motor/ Machine
connectivity 10 mmcopper wire.
Control panel to be designed for semi-auto operation of STP. (i.e. LLC based operation
for raw and filter). Pressure gauges will be provided on delivery main for pumps, blowers and
vessels. Agency shall complete the STP system and put in working order.No Extra payment
shall be done for electrical item mention in above description.
Mode of measurements & payments The rate shall be for a unit of one set.
NOTE :SCREEN CHAMBER,INLET TANK ,FILTER TANK (ALL Civil works ) SHOULD
BE PAID SEPERATELY UNDER ITEM NO
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Preparing structural design of RCC Under Ground / Partially under ground / above high
ground level Reservoir of required capacity as per relevant I.S.s and constructing the
same,including excavation in all types of soil strata (including rock) including shoring strutting
if required, for loose soil / to protect from collapse due to near by traffic load, casting 100 mm
thick P.C.C. leveling course in M-15, Refilling the pit with proper soil and disposing of the
surplus stuff at all lead . Including cement plaster in CM 1:2 with approved water proofing
compound to inside and out side up to 300mm ground level water touching surface to
container. Including all types of labour and material charges of lowering, laying, erecting /
hosting and jointing of pipe assembly to inlet, outlet overflow, washout and bye pass
arrangement as per hydraulic design. Providing and fixing accessories like MS / GI Ladder, CI
Manhole frame and cover, water level indicator, adequate cowl type ventilators or lantern type
ventilator with stainless steel jail. B.B. Masonry chambers for valves. Providing and applying
three coats of cement paint / snowcem to the out side face of structure. It also includes
satisfactory water tightness test as per relevant I.S. code and painting name of scheme and
capacity on the tank as per direction of engineer in charge. List of Indian Standards for Design
of GSR / SUMP:- The structural design of GSR shall be in accordance with provisions relevant
I.Ss. (1) I.S. 3370 part I & II 2009 or latest revised (1.1) I.S. 3370 part III & IV 1965 or latest
revised (2) I.S. 456 – 2000 or latest revised. (3) I.S. 1893 – 2000 – 1984 or latest revised. (4) I.S.
875, Part – 1 to 3, 1987 or latest revised.
General specifications :
[1].Water depth in container shall be adopted as per data of tender. If water depth is not
specified the suitable water hydraulic requirement shall be adopted for capacity.
[2].Shape of container (in plan) specified by in data shall be adopted in absence circular shape
shall be adopted.
[3].Size shall be fixed as per availability of space (land area) at site / acceptable engineer in
[4].Effect of overlapping of pressure bulbs on soil due near by structure and proposed sump
should be considered.Care shall be taken that no damage should occur to
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
[5].nearby existing structure. Compensation shall be paid for the same by agency.
[6].The minimum concrete grade for RCC shall be M-30
[7].Fe 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall be considered in design.
CRS / TMT bars shall be provided. In saline atmosphere corrosion resistance stainless steel /
HCR rebar shall be provided. Any other steel can be used with approval of C.E./ in situation
of non availability in market without extra cost.
[8].Minimum size (or thickness) of various components shall be provided as per tender criteria
/ specifications in absence as per I.S./ Std. practice of G.W.S.S.B. Minimum dimensions
specified for various components in tender data / specifications shall be provided without fail.
[9].The safe bearing capacity (SBC) shall be referred from SBC test report. In absence of report
it shall be referred from data sheet. If poor soil is found / water table is met with during
excavation SBC shall be scientifically ascertained and design shall be revise. No extra shall be
paid for increase in quantity.
[10].DI pipes and special shall only be used if type is not specified in tender.
[11].The rate shall include cost of dewatering during excavation making all arrangement when
water table meets within depth.
[12].The structure shall be designed properly to resist uplift due to ground water table
specified in data or actual ground water table meets with during excavation. If GWT / Uplift
iswater table meets with during excavation. If GWT / Uplift is mentioned in tender and during
excavation it dose not meet 7.5% rate shall be reduced.
[13].SS pipes railing shall be provided when sump height is ≥ 1.5 meter above ground level
[14a].RCC staircase/RCC Steps should be provided from GL to sump top slab based on the
height of the GSR above/below the ground.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
[14b].RCC Staircase with SS railing to be provided inside reservoir container. BB Masonry
staircabin to be provided to cover the same with MS safety door having locking arrangement
[15].Appearance of structure should be aesthetically good looking acceptable to authority.
[16].Any charge in size, shape, depth below GL, height above GL, water depth, F.B., size of
member etc can be permitted in exceptional case due to site condition or hydraulic design
requirement by C.E. No extra shall be paid for change.
[17].Any charge in data, dimensions, shape, water depth,reduction in size if permitted by
competent authority and if itreduction in size if permitted by competent authority and if it
reduces quantity then payment shall be reduced prorate.
[18].When capacity of GSR / Sump is > 20 lakh liters two or suitable compartments acceptable
to executive engineer shall be designed and provided.
[19].Agency shall engage qualified (at least graduate) consulting engineer for designing the
structure and he / she shall visit the site for guidance of work.
[20].75% part rate shall be payable for concrete, reinforcement and plastering items of
container until satisfactory hydraulic testing for water tightness is performed as per tender
condition. Till the work shall be treated as incomplete.
Above conditions / general specifications Sr. No. 1 to 20 are part and parcel of tender (contact)
and prevail over other
provisions in tender for below 1 to 5 differents capacity of Sumps for STP as per STP drawings
Screen Chamber -
18a 1000.00 Ltr 5.98 Rs. Five & Paise Ninety Eight Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
COLLECTION TANK
18b 50000.00 Ltr 5.98 Rs. Five & Paise Ninety Eight Only
Consrurting Manhole with RCC TOP SLAB IN 1:2:4 mix (1 cemente :2 corarse sand :4 graded
stone aggregate 20mm nominal size ) found . Concrete 1:3:6 ( 1 cement :3 corarse sand : 6 brick
bats 40 to 50mm size ) inside plastering 15mm thick with c.m 1:5 ( 1 cement : 5 corase sand )
finish with a floating coat of neat cement making channaels in cement concrete 1:2:4 ( 1cement
: 2 Coarse sand : 4 stone aggregate 20mm nominal size) finished smooth complete including
curing & testing (i) inside size 900mm x 1200mm including with 230mm thick wall of brick Rs. Sixteen Thousand Four Hundred
19 masonary using brick having crushing strenghth not less then 35 kg/Sqcm in c.m 1:5 for 2.00 No 16435.16
Thirty Five & Paise Sixteen Only
multipurpose pipe line ( B- type depth 1.50mt. for multipurpose line) Rate are also iclusive of
Provinding and fixing precast RCC cover
Providing & Laying ( to level or slopes ) and jointing reinforce concrete non pressure pipes I.S.
class NP 2 of the following internal diameter with collars & butt ends prepaid for collar joints
Rs. Six Hundred Seventy One &
20 including testin of joints. 300 mm dia pipe . 25.00 Rmt 671.32
Paise Thirty Two Only
Table: Size: (1.52 x 0.76 x 0.76)
Provinding and fixing 19mm thick plywood top table with fixing 25mm thick plywood (19mm
+ 6mm) patta of 300mm width fixed on bottom periphery .The plywood table top is laminated
on top and bottom.the front edges of the table top surface is to be covered with 12mm thick
teak wood bedding patty with melamine polish finish of approved shed.The Rate includes the
cost of fixing telescopic suspended metal keyboard with mouse tray. 38mm thick vertical legs
made from plywood with exterior side 1mm and interior side 0.8mm approved laminate.
Appron should be made from plywood with laminated finish as per detail drawing and CPU
Trolley should be supplied of metal powder coated. Footrest (0.75 x 0.37) should be from Rs. Sixteen Thousand Six Hundred
21 teakwood with melamine polish complete.Seperate Drawer unit box (0.65 x 0.41 x 0.43) to be 1.00 No 16622.62 Twenty Two & Paise Sixty Two
made from 19mm plywood with 1mm outside and 0.8mm inside laminate as well as approved Only
shade for Left or Right sidewith wooden bidding patti on nylon castors with handle,lock and
telescopic channel.Rate includes the cost of all materials and labour etc. complete as per detail
drawing and instruction of engineer-in charge.The necessary hardware fitting shall be as per
approved make list of GSPHCL.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Low Back Chair (Staff & Visitor ) (MODEL LIKE HOF OCT 173) Providing and supplying
Revolving synchro tilting mechanism based chair with gas lift for adjustable height and
medium curved back with seat and back PU moulded cushion with MS pipe frame structure
and white foam layer for seat and molded PU foam. White foam layer for back covered with
thick cloth and draped with cloth of approved shade. (min. of Rs.150/meter). 5 legged
revolving molded nylon chair base with good quality of PU castors with 2 years replacement Rs. Four Thousand Six Hundred
22 guarantee. The chair to have wide polyurethane arm rest of approved shape. Complete chair 7.00 No 4669.00
Sixty Nine Only
of chair should be as approved by engineer in-charge.
High Back Chair (MODEL LIKE HOF OCT 171) Providing and supplying Revolving synchro
tilting mechanism based chair with gas lift for adjustable height and medium curved back with
seat and back PU moulded cushion with MS pipe frame structure and white foam layer for
seat and molded PU foam. White foam layer for back covered with thick cloth and draped with
cloth of approved shade. (min. of Rs.150/meter). 5 legged revolving molded nylon chair base
with good quality of PU castors with 2 years replacement guarantee. The chair to have wide Rs. Seven Thousand Sixty One &
polyurethane arm rest of approved shape. Complete chair should be in suitable shape. Rates to Paise Eighty Six Only
engineer in-charge.
Conference Table
Providing and fixing 25mm (19mm+6mm) thick (plywood, interior grade/MDF/with post
forming laminated top in approved shed) with bottom 0.075m. 19mm ply patta for edge
thickness and edges should be cover with 1mm Outside & 0.8mm interier side approved
laminate with 38mm (19mm+19mm) thick vertical legs made by plywood with exterior side
with laminated finish and 8mm thick plain glass fixed in center of the apron area as per detail Rs. Six Thousand Nine Hundred
drawing, footrest should be from 19mm plywood with laminated finish in approved shade. Eighty & Paise Ninety One Only
Including all materials and labour, all edges should be laminated etc. complete as per detail
drawing and instruction of engineer in charge and Architect.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles having Regular
edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight
calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part
IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC.for the best
thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture Fine
fissured/Spintone/Cosmos having NRC value of 0.5 & Globe having NRC value of 0.75 NRC
or equivalent of size 595 X 595 mm to be laid on true horizontal level suspended inter locking
metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including
both side) consisting of main 'T' runner suitably spaced at joints to get required length and size Rs. One Thousand Six Hundred
25 of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross 18.94 Smt 1657.57 Fifty Seven & Paise Fifty Seven
T' of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced Only
between main 'T' at 600mm centre to centre to form a grid of 1200X600mm and secondary cross
'T' of length 600mm and size 24x28mm made of 0.30 mm thick (Minimum) sheet to be
interlocked at middle of the 1200X600mm panel to form grid of
size 600x600mm resting on periphery walls/partitions on a perimeter wall angle pre-coated
steel of size (24X24X3000mm made of 0.40mm thick (minimum) sheet with the help of rawl
plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying
15mm thick Densified edges light weight calcium silicate ceiling tiles of approved texture (Fine
Fissured/Cosmos/Spintone) in the grid including, cutting/making opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main 'T'
runners to be suspended from ceiling using G.J. slotted cleats of size 25X35X1.6mm fixed to
ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.l. adjustable rods with
galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main
'T' bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked
paint, for all heights, as Per specifications, drawings and as directed by engineer-in-charge.
Note:- Only calcium Silicate false ceiling area will be measured from wall to wall. No
deduction shall be made for exposed frames/opening (cutouts) having area less than 0.30sqm.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
The calcium silicate ceiling tiles shall have NRC Value of 0.50 (Minimum) for
Finefissured/Spintone/Cosmos and 0.75 NRC for Globe, light reflection 85% noncombustible
as per B.S. 476 part-IV, 100% humidity resistance and also having thermal conductivity. 0.043"
w/m KC.for the best thermal Insulation.
Providing and fixing wall acoustical paneling with using CS65 and IC 91 framing directly to
the wall and then fixing 12.5 mm perforated board with the help of screw and using rock wool
of 60 kg density and 50 mm thick between framing and perforated sheet. Then fixing Ecotone
make Micro polyester tiles acoustic wall paneling with the specification of 50MM thick having
density of 180 kg/m3 with NRC value of 0.80 surface matt finish which is fixed with solution Rs. Four Thousand Six Hundred
26 SR665 as required. The panel should have euro class B ASTM E84-13 fire rating. The color 67.00 Smt 4628.75 Twenty Eight & Paise Seventy Five
shade of Panel as approved by Architect. Including all accessories, material & labor complete Only
as directed by Engineer.
Providing, Supplying and Fixing 16MM thick HDF Board of Approved Brand. The rate
inclusive with labours, Adhesive,Cutting and Fixing As per drawing and as Directed by Rs. One Thousand Ninety Six &
engineer-in-charge. Paise Fifteen Only
Civil Amount
Providing & erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC
insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth
continuity in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed
rigid PVC pipe with PVC fitting fixed with adhesive solution erected on/in Brick Wall / slab
along with continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC
pipe and boxes shall be filled with cement mortar and finishing the surface to match the wall /
ceiling complete with approved make 5/6 Amp. ISI make modular type switch and accessories
mounted in 20 G. G.I. company fabricated metallic box covered with appropriate front plate Rupees Four Hundred Sixty One
28A 8.00 Point 461.00
modules erected flushed with wall / ceiling with necessary modular lamp holder / modular Only
ceiling rose / HD Connector as directed..(Deep Junction box 75mm depth if required)(Make &
Model approved by EIC and matching colour with switch and accessories) for concealed
wiring. Light point. Cat.-II
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent
mortar going into the box. Length of point wiring must not increase than 10 mtr. For that
necessary switch boards and their locations must be finalised before execution by agency
otherwise payment will not be done for extra long point. (For future extention, if required,
agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost
of blank plate shall be paid as per tender item) [This item include cleaning (inside/outside) of Rupees Nil
all G.I. switch boards, electric point box, fan box, MCBDB & box cutting plaster finishing for
modular plate without any gap]
For Fan Point (with 6 A. Modular type switch and two module hum free EME Five step type
Rupees Six Hundred Forty Eight
28B Electronic fan regulator both having ISI mark) Cat.-Il. 2.00 Point 648.00
For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.-Il
Rupees Four Hundred Eighty Nine
28C 2.00 Point 489.00
For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.-
Rupees Two Hundred Thirty Four
28D Il 4.00 Point 234.00
Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed)
RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish
29A wire to draw mains with necessary fittings and junction boxes for following dia. (a) 20 mm. 120.00 Mtr. 24.00 Rupees Twenty Four Only
25 mm dia.
29B 90.00 Mtr. 33.00 Rupees Thirty Three Only
For 32 mm dia
29C 50.00 Mtr. 54.00 Rupees Fifty Four Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with FIA
approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with PVC
fitting fixed with adhesive solution to be erected on/in brick wall / slab along with continuous
G. I. fish wire to draw mains laid in approved manner with plastering by cement mortar &
finishing the surface to match the wall / ceiling complete with FRLS PVC insulated wire for
30A earth continuity. (Approved ISI make only) [a] 2 x 1.5 sq.mm. FRLS copper multi stranded 80.00 Mtr. 62.00 Rupees Sixty Two Only
conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for earthing as per
standard colour code. [conductor resistance should be as per IS:8130/1984]
For 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper
multi stranded conductor for earthing as per standard colour code. [Wire must be having box
30B 50.00 Mtr. 82.00 Rupees Eighty Two Only
2 x 6.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper
multi stranded conductor for earthing as per standard colour code. [conductor resistance
Rupees One Hundred Forty Six
30C should be as per IS:8130/1984] 90.00 Mtr. 146.00
Providing & fixing 20mm. dia. PVC insulated G.I. corrugated Flexible pipe with necessary
socket, PVC bushes saddle, Check-nuts etc. complete of following sizes.
31 30.00 Mtr. 31.00 Rupees Thirty One Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and fixing Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x
sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS
wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm
dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected in
wall/slab along with continuous G. I. fish wire to draw wires and laid in approved manner
zari for PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match
the wall / ceiling complete with 16 Amp Modular type Swich and accessories mounted in
G. GI company fabricated metallic box covered with appropriate front plate modules erected Rupees Seven Hundred Twelve
32 2.00 Point 712.00
flushed with wall. (a) 16 Amp. Indicator switch & 1 No. 6/16 A universal socket white colour Only
suitable for 3 pin top duly both having ISI mark. (Necessary sheet / tape / polythene / sand
must be erected or filled in all box To Prevent Mortor Going In To The Box) Cat.-II
Providing & Erecting 2.0 mtr long Earthing system by making minimum bore of 225 mm dia
in soft soil. Suitable for doing pipe-in-pipe technology earthing.Earthing electric rod must be
made from Corrosion free Hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outerpipe:- 88 mm minimum O.D., ISI 'B ' Class ISI mark of Reputed
Brand, Inner pipe:- 42 mm minimum O.D., Pipe B Class ISI mark reputed Brand Terminal
Size: 70mm X 100mm length, Terminal Should be made from inner pipe for that pipe must be
pressed and gave rectangular shape so its work as a terminal.The hot deep galvanising must
be done after above process.Galvanised thickness must be minimum 75 micron any where. SS
Nut bolt:- 2 no.with washer suitable for 14mm dia. hole must be provided at terminal. total
minimum Weight(approx.) of earth electrodewith inside conductive material minimum
should be 26 kg. Rupees Seven Thousand Twenty
33 (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm/meter testing as per IEC 62561- 4.00 Each 7025.00
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long
time Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm
depth and Cover should be heavy duty cast iron with required size of 300 mm X 300 mm X
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to
submit all detail & sample for approved before supplying] Rupees Nil
[Water must be poured in bore before starting earthing. Earthing value must be measured with
earth tester. Agency has to bring the earth resistance to at least 02 ohms & voltage between
neutral & Earthing upto 02 volt. Agency has to maintain earthing & its value for one year.
Earthing must be done in the presence of A.E. (GSPHCL)]
For above earthing additional charges for boring in hard rock soil (by breaker) & filling soft
soil in earth pit (certificate for soil have to given by DEE / AE along with photographs) Rupees Two Hundred Seventy Six
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for
mounting mob & hinged doors as per requirement having locking arrangements with
35 mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& 2.00 Each 890.00 Rupees Eight Hundred Ninety Only
earth bolt of following size of box.(A) 300mm x 200mm x 100mm [deep]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Supplying and Erecting LED indoor fitting of approximately 4feet long with LED of wattage 0.2W to
0.5W assemble on single MCPCB with housing use as a heat sink shall be made from Aluminum
extrusion having enough strength (sample must be
approved by EIC) with polycarbonate diffuser with following specification:(A) Company mark/name on the
(B) Rated input voltage and frequency: 220V to 240 VAC ; 50Hz.
(C) Rated input wattage: max. 24w
(D) Rated input current : 0.2 Amp
(E) Power Factor : Min.
(F) ATHD : Max. 15%
(G) Rated Luminous flux: Min. 2420 lm
(H) CCT: 6500K
(I) CRI: Min. 80Ra Rupees Three Hundred Seventy
36 (J) Driver Efficiency: Min. 80% 4.00 Each 370.00
(K) LED life span: Min. 50000 Hrs @ L70
(L) Over Voltage protection: Withstand up to 440V/AC for 4 Hrs.
(M)Surge protection : Min. 2KV
(N) IP rating: IP
(O) IK rating : IK
(P) Short circuit , Open circuit & Reverse Polarity Protection must be provided
(Q) Fixing clamp design & strength should be sufficient to hold the fitting erected on wall or ceiling.
(R) 3 core copper wire of appropriate size with earthing connector(Note:-The manufacturer/ authorized Channel
partner of the manufacturer has to
submit 5 yrs free replacement Guarantee for complete Fixture) [Approval will be given strictly subject to
item specification]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing, erecting, testing Ceiling Fan confirming to IS: 374/1979 AMDT No. 1 to 6 Class-I,
50 Hz. Specification of Ceiling Fan must be as per below. (1) Sweep: 1200 mm, (2) Operating
Voltage: 180 to 230 V, (3) Power Factor: > 0.9, (4) Power Consumption: maximum 53W, (5)
RPM: minimum 330, (6) Service value:min 4.3 m3/min. (7) Class of insulation: 'B', (8) No. of
heavy duty premium quality Ball bearing: Two, (9) Total Body: Top & Bottom should be
alluminium, (10) Blade: Aluminium approx 1.1 mm thick, (11) Colour: White high grade
powder coating, (12) Canopy: Two Nos. Heavy duty, (13) Condenser: min 1.5 MFD (15%
Tolerance )as per is 1709-1984, Aluminium body premium quality, Branded make,(14) Down
road: up to 1.0 mtr as per site requirment, (15) Required fixing accessories, (16) 3 core Rupees One Thousand Nine
0.75 sq.mm ISI wire as per site requirment, (17) No vibration and noise due to mechanical Hundred Twenty Nine Only
parts. (Agency has to erect safey wire with ceiling fan and checked with EIC) (OEM has to
approved model as per tender specification and tested at ERDA) (Necessary test reports
should be submitted strictly at the time of approval. Sample approved by EIC subject to above
specification only)
Supplying and erecting 8 W LED lamps with following wattage capacity of 220 to 240 voltage,
minimum 15000 burning hours life, 500 V in built-surge protection,Polycarbonate diffuser,
mounting suitable for E14 / E27 / B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type,
38 2.00 Each 111.00 Rupees One Hundred Eleven Only
with PC diffuser suitable LAMP holder
Providing and erecting Polycarbonate body surface mounting LED Bulk head type 9 watt
Lighting Fitting with electronic driver having THD < 15%, CRI>80, P.F.0.95 And lumen
output from luminaire 720 lm, input voltage range 90-300 V AC, 50 Hz cool white (3000 to
39 k), inbuilt driver having efficiency >=80lm/w, -20 deg C to + 60 deg C working temperature, 2.00 Each 780.00 Rupees Seven Hundred Eighty Only
AL frame with Beam Angle 120 deg.
Supplying & Erecting Fan Hook Of 10 mm M.S Round bar bounded to the RCC bars up to
mm Length each side & piereced through 18 Gauge G.I Box having 125 mm dia depth of
Rupees One Hundred Twenty Five
40 mm complete erected concealed in ceiling with necessary modular plate / sheet. 6.00 Each 125.00
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor
type cubical panel board having IP-42 & above protection as per approval from engineer
incharge and made from 2 mm. thick CRCA sheet for outer body & doors, 1.6 mm. thick CRCA
sheet for internal partitions with necessary supporting angles, flats including skirting, bending,
drilling, welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-In-Charge with erection of supplied switchgears, busbars with suitable
size of interconnecting PVC copper wire / Copper-Aluminium strips, rubber gromets, rib, Rupees Sixteen Thousand Two
41 1.50 Sq. Mtr. 16230.00
control wires, backelite control fuses, measuring instruments, earth bus & earth bolts, Hundred Thirty Only
foundation flange-bolts-base plates, sufficient nos. of hinged doors, handle with locking
arrangement, rubber gasket complete with Required Nos. heavy Duty Connector with
Cadmium plated nut and bolt for Anti rusting
The panel shall be supplied with Seven Tank chemical process which shall be carried out
before applying painting, painted with powder coating. (The rates excludes the cost of
switchgears, busbars, interconnecting mains & Copper / Aluminium strip, fuse, meters etc.
The dimension shall be measured excluding base beams) The standard companies switch gear
shall be used and only manufacturers at CPRI approved factory as per IEC 61439 and shall be Rupees Nil
certified by that company whose switch gears are used after fabrication for beneficial use. With
350 mm depth
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Panel manufacturer have to give 3 years maintenance and service support if in case of
breakdown or fault. Panel manufacturer have to submit electrical meter calibration report.
Agency should design the panel in such a way that there should not be any excess in panel
area (sq.mtr) & length of bus-bar (mtr), if any excess occurs draw attention to GSPHCL at the
time of approval of G.A. drawing.
Loading and unloading of above item shall be done by hydra and skill work force under
supervision of electrical engineer and guidelines given by manufacturer to avoid damage to
the item. Picture of it to be submitted in running bill / final bill.
Size of door and Ele. room / Pump room shall be checked by agency's engineer before giving
order. If found any problem in size discuss with GSPHCL engineer for rectification before Rupees Nil
giving order. [Including Necessary numbering / marking on PANEL done with red colour
radium sticker as per site requirement and instructions given by EIC on site. Font / number
size given by EIC on site as per requirement] (All Panel as per IEC 61439 as per NBC
Guideline) [Manufacturer must be of Gujarat state so three stage inspection can be done]
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 35 K.A. at 415 V having normal current rating of 125 A. with
variable/Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all
Rupees Seven Thousand Nine
42 internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. 1.00 Each 7976.00
Hundred Seventy Six Only
ICS=100% of ICU only.
Providing and erecting Approved make Four pole moulded case circuit breaker having
breaking capacity ICU of 25 K.A. at 415 V, having normal current rating up to 25 A to 100 A.
with variable/Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with
Rupees Six Thousand One Hundred
43 all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. 4.00 Each 6112.00
Twelve Only
housing. ICS=100% of ICU only
Supplying & Erecting Approved Make Extended operating rotary handle with pad lock with
three position Trip, Off, On suitable for 25 Amp. to 250 Amp. panel mounting.(Company Rupees Eight Hundred Sixty Five
Must be same company of switchgear) Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly wraped with colour insulating tape for phase
sequence of following current carrying capacity, erected with necessary bus bar supports /
Rupees Three Thousand One
45 insulators, main cable socket to each bar, erected in existing cubical panel with necessary 2.00 Rn.Mtr 3171.00
Hundred Seventy One Only
connections.For electrolyte copper busbars suitable for 200 Amp. capacity
Supplying and erecting Approved make Earth fault Relay suitable to mount with inter
connection to moulded case circuit breaker having CT ratio & MCCB rating as following along
with shunt trip 220 V AC with all internal connections & complete erected in existing
Rupees Four Thousand Nine
46 M.S.housing.(2) 125 A - 200 A, CT Ratio 1/200 [make and model approved by EIC strictly as 1.00 Each 4934.00
Hundred Thirty Four Only
per tender specification]
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 x
1/2 digits LED display, 0 to 750 AC Volts range having 0.5 class accuracy erected on existing
panel board with all connection, wiring etc. with manufacturers calibration certificate. [make Rupees One Thousand Two
and model approved by EIC strictly as per tender specification] Hundred Sixty Three Only
Supplying and erecting approved make panel mounting type Digital Ammeter having
digits LED display, external CT operated, calibrated for 0 to 1000 Amps. suitable to operate on
500 Volt AC, having 0.5 class accuracy erected on existing panel board with all connection,
Rupees One Thousand Five
48 wiring etc. with manufacturers calibration certificate. [make and model approved by EIC 1.00 Each 1543.00
Hundred Forty Three Only
strictly as per tender specification]
existing panel board with necessary connections. [make and model approved by EIC strictly as Rupees Three Hundred Fourteen
per tender specification] Only
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover,
50 complete erected with necessary connections. 3.00 Each 43.00 Rupees Forty Three Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and Erecting of Miniature circuit breaker single pole 6 Amp. to 25 Amp. suitable
to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing
51 box. confirming to IS 8828/1996 with ISI Mark. 3.00 Each 111.00 Rupees One Hundred Eleven Only
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA
burden having 0.5 class accuracy erected in existing CRCA box duly secured with insulating
Rupees Two Hundred Seventy Two
52 materials connected to the meter [make and model approved by EIC strictly as per tender 3.00 Each 272.00
specification]
Providing & erecting 240 V MCB Double pole switch for Motor & Inductive load (C curve)
having 10 KA breaking capacity & confirms to IS:8828 in Existing M.S. box having following Rupees Three Hundred Twenty
capacity. For 40 Amp. Seven Only
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS :8828 in existing box having following capacity [c]
54 2.00 Each 730.00 Rupees Seven Hundred Thirty Only
Supply, Installation, Testing & Commissioning of Three Phase, 440 V Surge Suppressor
protection Device (SPD) & 40 Amp TPN MCB (or As per SPD OEM guide line for the
protection of SPD which is erected such a way that it can be operated easily) SPD must be
capable to protect all electrical and electronics equipments if SPD blast or fuse then the panel
Rupees Six Thousand Three
55 builder must have replace it soon during defect liability period.The Detail Specification of SPD 1.00 Each 6319.00
Hundred Nineteen Only
are As per Attached sheet with Annexture -A(E). (Hakel,ikra,OBBO make) (With Three year
Gaurantee/warranty)
Providing, erecting, Fabricating the M.S. structure as per requirement of site as per structure
design Including proper size approved by EIC of M.S. angles, flats, bars, square pipe,
channels, sections (Tata, Jindal, Asian, JSI Make) complete with cutting, welding, grinding and
finishing duly painted with Asian/Nerolac make premium quality oil paint and true care red
oxide metal primer,asian paint make with erection on site as per direction of engineer in charge Rupees Seventy Five And Paise
56 with necessary grouting cementing, plastering and finishing complete. All hole opening of 60.00 Kg. 75.20
Twenty Only
square pipe end must be closed with M.S plate welding. Payment will be done on KG as per
Actual weight.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Supplying & erecting 12 mm thick backelite sheet of approved make and grade on existing
x 25 x 3 mm red oxide painted angle iron frame suitable for fixing ICDP SWITCH and energy
meter (contractor shall make approved drawing of Bakelite sheet To arrange required No. of
Energy meter & ICDP/MCB switch-busbar etc. as per Actual space available in electrical room Rupees Two Thousand Two
57 1.00 Sq. Mtr. 2289.00
at site) Hundred Eighty Nine Only
Providing and erecting metalic danger notice board for MEDIUM VOLTAGE installation to be
58 erected as per I.S. 2.00 No. 69.00 Rupees Sixty Nine Only
Providing and erecting approved make single phase Double Door metal clad D.B. as per relevant
indian standards ammended upto date. Supplying and fixing following way single phase MCB
distrubution board of company fabricated with sheet box with powder coated inside and outside after
apply seven tank chemical process of CRCA sheet (MCBDB Door, Backside & Body must be made of
1.2 mm thick CRCA sheet )cover complete with suitable integral single piece construction tinned
copper busbar and link with all necessary interconnection and with necessary size MS frame for
mounting MCBDB. Manufacturer must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC 61439-1 &
having D type PU gasket. (2) Seven tank Powder coating Certificate (3) Tinned Copper/Brass make
neutral & Earthing link with isolation & Protecting Cover for 240 Volts on surface / recess complete
with loose wire box, terminal connectors for all incoming and outging circuits, with suitable size FRLS
PVC insulated copper conductor up to terminal blocks and internal connection, tinned coppper bus
bar, 1 no. tinned copper neutral link, tinned copper earth bar, din bar, detachable gland plate,
interconnections, powder painted including earthing etc. Single phase incoming and horizontal single
phase outgoing. For 16 Way MCBDB: Including 40 Amp. 30 mA double pole ELCB (ELCB Rupees Five Thousand Eight
confirming to IS:12640/1988 having sensitivity of 30 mA and breaking capacity of 10 KA), MCB 40 Hundred Sixty Nine Only
Amp. double pole switch (C curve confirms to IS:8828 having breaking capacity of 10 KA) and S.P.
MCB of rating 6 to 32 Amp. with NL suitable to operate on 240 Volt A.C. power. (6/25 Amp sp mcb
company of MCB / ELCB to be used) (MCBDB must be erected in line & level with spirit level and
finish the external edge with box cutting plaster) (Same colour MCB(SP/DP) should be used as
same as MCBDB) [Including Necessary numbering / marking on box done with red colour radium
sticker as per site requirement and instructions given by EIC on site. Font / number size given by
EIC on site as per requirement]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS:8828 with same company metal box with earthing
Rupees One Thousand One
60 terminal having following capacity with necessary Numbering / marking with oil Paint by 1.00 Each 1172.00
Hundred Seventy Two Only
painter. [c] 63 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having
10KA breaking capacity & confirms to IS :8828 with same company metal box with earthing
Rupees One Thousand One
61 terminal having following capacity with necessary numbering/marking with oil paint by 1.00 Each 1104.00
Hundred Four Only
painter. For 40 Amp.
Providing and laying Mains with ISI marked, 1.1 KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS:694, IEC -
erected in existing pipe of following size (Specifically for control panel, relays, power Rupees One Hundred Forty One
62A 60.00 Each 141.00
switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts Only
if required. [g] One wire 16.00 sq. mm [For Earthing]
62B For One wire 10.00 sq. mm 60.00 Mtr. 91.00 Rupees Ninety One Only
For One Wire 25 sq.mm wire Rupees Two Hundred Thirty Four
Supplying and erecting approved make single phase servo controlled voltage stabilizer
suitable for input voltage range 180/250 V And output voltage range 225/235V. A.C. Rupees Six Thousand Three
complete erected. (a) 1.0 KVA Single Phase. Hundred Ninety One Only
Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Aluminium conductor cable
for 1100 volt to be laid 90 cms. Under ground or to be laid on wall with 1.00 m.m thick G.I.
Rupees Two Hundred Eighty Two
64 heavy guage cable clamp or in existing DWC pipe underground or road crossing or floor . 50.00 Mtr. 282.00
(C) 3 1/2 core 50 Sq. mm (25 Sq. mm 1/2 core)
Providing & erecting XLPE (IS : 7098) (I)-88 ISI marked armoured Copper cable for 1100 volt to
be laid 90 cms. Under ground or to be laid on wall with suitable G.I. heavy guage 1.0mm thick
Rupees Two Hundred Sixty Nine
65A cable clamp or in existing DWC pipe underground or road crossing or floor. (a) For 4 core x 30.00 Mtr. 269.00
For 4 core x 4 sq.mm. Rupees Three Hundred Sixty One
For 4 core x 10 sq.mm
65C 20.00 Mtr. 670.00 Rupees Six Hundred Seventy Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing & laying HDPE Double walled corrugated pipes (DWC) (conforming to IS:
(part 24) 2018)) with minimum load required of 450N capacity with anti rodent and ultra violet
material properties with necessary connecting accessories of same material at required depth
to be laid 90 cms. under ground for laying of cable below ground / road surface for enclosing Rupees One Hundred Seventeen
cable and back filling the same to make ground as per original. (A) For Outer dia. 50 mm and Only
Inner dia. 38 mm. ) (Test Certificate to be Submitted)
66B (C) For Outer dia. 90 mm (Test Certificate to be Submitted) 30.00 Mtr. 150.00 Rupees One Hundred Fifty Only
Providing & erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as directed. 3 core x 1.5 sq.mm. PVC insulated
67 20.00 Mtr. 46.00 Rupees Forty Six Only
round copper wire ISI mark.
Supplying & Erecting following size of Light duty “A” Class G.I. Pipe & erecting as directed
Rupees One Hundred Seventy One
68 by Engineer-in-charge. For 25 mm dia. 10.00 Mtr. 171.00
Providing & fixing double compressed heavy duty flange type brass cable gland with rubber
ring for P V C insulated armoured cable complete with outgoing tails, insulating tape etc. For
69A following size cables. For 2 to 4 core x 4.0/ 6.0 Sq. mm (Sigma, MCI, Comet Make Only) 8.00 Each 43.00 Rupees Forty Three Only
For 2 to 4 core x 10.0 Sq. mm (Sigma, MCI, Comet, Make Only)
69B 4.00 Each 48.00 Rupees Forty Eight Only
For 3*1/2core*50 Sq. mm (Sigma, MCI, Comet Make Only)
69C 4.00 Each 75.00 Rupees Seventy Five Only
Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box with Hot
Deep Galvanised door having 2 nos. 180° operated hinges & 2 nos. Ln key locking with
silicon rubber gasket. Consist of terminal plate of min 6mm Hylam sheet, standard profile
35 mm X 7.5 mm Din-Rail & MCB, Brass stud type terminal and arrangement for cable
Rupees Eleven Thousand Four
70 termination to be erected on RCC foundation as per details given by manufacturer and EIC 2.00 Each 11410.00
Hundred Ten Only
considering site requirement.
Foundation Details: (1) Grade of RCC 1:2:4, (2) Grade of steel rainforcement of RCC FE 415, (3)
Clear cover to rainforcement 50mm, (4) Concrete vibrated, (5) use suttering / farma, (6) Hot
deep galvanized average 70 Micron, (7) Detail drawing will be given by corporation
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
(C) 7 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with 225 mm X 225 mm X
16 mm base plate, 4-M20 Bolts and 600 mm long hot deep galvanized J-Bolt, nuts, washers
with 800 mm under ground and 200 mm above ground level and Foundation in 1:2:4
proportion as per details given by manufacturer and EIC considering site requirement. Rupees Nil
Approx Pole weight 67 kg.(Make:- Bajaj, Valmont, Transrail, Ambica Only) (Test certificate
to be submitted)
Providing & erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside diameter
complete with suitable G.I. Sleeve tubing of 2 mm. thick and required size and length suitable
for 76.5 / 80 mm. required size of pole top or pipe in pipe surface for terrace as per instruction
of EIC or wall bracket as per instruction of EIC having nuts and bolts for fixing the brackets
and having spread of Upto 0.70 mtr. length with suitable rise as per site condition and suitable
welded stiffner reducer and nipple with check nut complete painted with one coat of yellow Rupees Four Hundred Eighty Seven
zinc and two coats of alluminium paint for Single arm bracket suitable for pole or terrace as Only
per design given by EIC (a) For single arm bracket. (Jindal / Asian / Tata / Surya Prakash
make Only) (Fabricators:- Bajaj, valmont, Transrail, Ambica Only) (Test certificate to be
submitted)
Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S.
sheet having following size complete with fixing arrangement for terminal board, with
necessary hole for wire entry and exit from the box. The box shall be provided with cover and
hinges on one side and bolting at other end The box shall be fixed by clamps fabricated from
25mm x 6mm flat.The box shall be painted with one coat of red oxide and two coats of paint
72 having following box size 330 mm x 260 mm x 140 mm (depth). Providing and fixing Terminal 3.00 Each 702.00 Rupees Seven Hundred Two Only
board of size 5.0 x 127 x 152.4 mm.bakelite sheet with 15 Amp. kitkat pattern porcelain fuse
unit with suitable brass studs with nuts, washers and clamps of size 25 mm x 3 mm suitable for
pole painted with one coat of red lead paint.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of Outdoor aesthetically designed LED Street Light Luminaire with total consumption of
Max. 45 W with single piece die cast aluminium housing, high power LED shall be mounted
on high quality metal core PCB with extremely precison designed heat sink complete with
IP66 protection Class with polycarbonate / thoughened glass cover the fixture should be
suitable for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines
with LED module min. 130 lumen/watt with toughen Glass L70 at 50,000 hrs, provided with
high quality polycarbonate lenses for better light distribution. The Fixture Should be able to be
Pole Mounted and also bracket mounted, provided with high quality driver for protection Rupees Three Thousand Five
against high and low Voltage cut Off, opertional for high amibient and high humid Hundred Twelve Only
envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should
meet the following technical criterias Oprating range Voltage 160 to 270 V, system efficiency
>= 110 lm/w, and total lumens not less then 4950, CCT > 5000K, CRI > 65, beam angle 120 deg,
surge immunity level at least 4 KV integral and 10 KV non integral
The Separate Potted driver should have over current, over voltage protection, short circuit
protection so that the fixture recovers once the fault is removed. In addition to the above
product should be operational in the temperature range of 0 deg to 50 deg and humidity range
of 10% to 90% RH.The watt capacity of each LED Should be gereter than equal to 5Watt (Note:- Rupees Nil
The manufacturer / authorized Channel partner of the manufacturer has to submit 5 yrs free
replcement Guarantee for complete Fixture)
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption of
maximum 90 W with single piece die cast aluminium housing, LED's mounted on high quality
metal core based PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The fixture should be suitable
for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED
minimum 130 lumen/watt with L70 at 50,000 hrs, provided with high quality polycarbonate
Seperate lenses for better light distribution. The Fixture Should be able to be Pole Mounted
and also bracket mounted, provided with high quality potted driver for protection against,
high and low Voltage cut Off, opertional for high amibient and high humid envirnoments,
THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the Rupees Six Thousand Two Hundred
following technical criterias. Operating range Voltage 160 to 270V, system efficiency > 110 Twenty Eight Only
lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral... Flood Light lumens shall be more than
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
5yrs free replcement Guarantee for complete Fixture) (Provision in Estimate For Garden)
Providing & fixing Solderless crimping type Copper lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to switchgear terminals
75A with brass/cadmium plated nut bolts in an approved manner. [a] 1.5/2.5 to 6 Sq.mm 50.00 Each 8.00 Rupees Eight Only
75B (B) 10 Sq.mm 16.00 Each 10.00 Rupees Ten Only
Providing & fixing Solderless crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected to switchgear
76A terminals with brass/cadmium plated nut bolts in an approved manner. [d] 50 Sq.mm. 12.00 Each 20.00 Rupees Twenty Only
76B (C) 16/25 Sq.mm. 4.00 Each 15.00 Rupees Fifteen Only
Providing & Erecting Universal Astro 5 KVA intelligent streetlight control system insu with
weather proof box for outdoor application. (As per specification attached separately) (Make Rupees Twelve Thousand Eight
and model approved by EIC) Hundred Ninety Five Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Supplying and erecting Servo Controlled Voltage Stabilizer (SCVS) as per following
requirement: (1) Input Voltage Range - Three Phase 340 To 480 Volt AC. (2) Out put Volatge -
Three Phase 415 Volt AC (Line - Line) with Voltage Regulation of +/- 1%. (3) Frequency range -
47 Hz To 63 Hz. (4) Efficiency - More or equal to 98%. (5) Type of Stabilizer - Suitable for
Balance & Unbalance Load and Voltage including SPD (6) Controlled Type - Digital Micro
Controller Based Disply. (7) Rate Of Correction - Upto 100 Volt / Sec (Line - Line) (8) Servo
Motor Drive - AC Syncronous Stepper Motor - As per KVA Capacityy, Out put volatge and
Voltage regulation requirement. (9) Nil Wave form Distortion and Effect of Load POwer. (10) Rupees Sixty Six Thousand Four
78 Responce Time - 10 milli second. (11) Protection requirements - Input low Cut off protection / 1.00 Each 66413.00
Hundred Thirteen Only
Input High Cut Off Protection / Output Low Cut Off protection / IOutput High (12) Fault
Annuciation Panel LED shows Input present, Input high Input low, Output Normal, Output
High, Outpur low, Overload. (13) Output On time delay - 10 seconds (14) Ambient
Tempeature capacity - 0 - 45 RH upto 90 %. (15) Enclosure Type - IP20 (16) Type of Cooling -
Air,Output:Bypass switch with changeover switch, & 5 year free replacement guarantee on
Stamp paper.
Loading and unloading of above item shall be done by hydra and skill work force under
supervision of electrical engineer and guidelines given by manufacturer to avoid damage to
the item. Picture of it to be submitted in running bill / final bill.Size of door and Ele. room /
Pump room shall be checked by agency's engineer before giving order. If found any problem in Rupees Nil
size discuss with GSPHCL engineer for rectification before giving order. 20 KVA (Air Cooled)
(make - Fuji-Electric,Servomax,Krykard)
Supplying and erecting approved make GRP/FRP Perforated type Cable Tray Material –
Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured
from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard
Length : 3000 mm- Support Span – 1500 mm, Deflection L/200 - Specification NEMA FG1 1993-
UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability -
Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 -
Flame Spread (Extent of Burning) – 20 mm as per Standard ASTM D 635 - Tensile Strength – Rupees Five Hundred Twenty Six
79A 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 30.00 Rn.Mtr 526.00
as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D
256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol
Hardness – 50 – 65. Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm
Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading
79B 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span. 30.00 Rn.Mtr 230.00 Rupees Two Hundred Thirty Only
Providing and erecting open well type horizontal submersible mono block pump set with
cast iron body having following specification [E] For 3 phase open well horizontal mono block
pump set suitable for 85 LPM to 270 LPM discharge at required head as per plumbing length
and vertical & Horizontal head. Agency has to submit the details calculation of head to
GSPHCL and get approval of make and model of pump having tender specification with TDS
& GA drawing. Suitable for 32/40/50/65/75 mm dia delivery pipe with 10 mtr. necessary Size
3 Core Flat copper flexible cable. (Body: Cast iron / Winding : Copper / stator : Copper / rotor
: Copper / shaft : SS / Carbon material test certificate from manufacture shall be Rupees Fifteen Thousand Five
submitted).The model of the pump with respect to head and discharge will be approved by Hundred Fifty Two Only
EIC. Pump should have following specifications: (1) Minimum 10 mtr. Cu. flat cable of suitable
size must be provided with pump.(2) Pump shall be installed as per manufacturer
foundation/erection drawing or as per IS specification. (Body full C.I., stator winding- copper,
rotor- copper, shaft- SS / carbon material, motor-Energy efficiency)
Supplying and erecting approved make 3 HP DOL type motor control cubical panel made
from 16 G. CRCA sheet duly epoxy powder painted inside and outside with hinged doors and
locking arrangement Floor Mounting On 300 mm Height with MS Stand Angle & CC
Foundation. Size 35 mm (H) x 35 mm (W) x 05 mm (D). The detail specification & quantity of
Rupees Forty Seven Thousand Sixty
81 material used are as under. 1.00 Each 47062.00
Panel must be with minilec relay for auotmatic change over for pump 1 & 2 logically without
using manually change over switch (Minimum Panel Size: 1.10 meter (H) x 1.10 meter (W) x
0.25 meter (D).
INCOMMER SECTION: (1) MCCB-30 KA-FP (DU-100H), Rating: 63 Amp., Make: L&T, Qty:
01 No. (2) Digital Ammeter (SR-65), Rating: 0-60 Amp., Make: Meco, Qty: 01 No. (3) Ammeter
Make: Salzer, Qty: 01 No. (6) C.T.- Current Transformer, Rating: 60/5 Amp., Make: Virat, Qty:
03 Nos. (7) Indicating Lamps (R,Y,B), Rating: 22.5 mm LED, Make: Airon, Qty:03 Nos. (8) SP Rupees Nil
MCB , Rating: 20 Amp., Make: L&T , Qty: 03 Nos. (9) Control Wiring, Rating: 1.0 Sq.mm,
Make: Any ISI, Qty: Lot (10) Copper Busbar, Rating: 63A/100 Amp., Qty: Lot (11) Numeric
logical relay, Qty: 1 No.
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Outgoing Feeder (3 HP DOL Feeder): Qty: 02 Nos. (1) MCB-FP-10 KA, Rating: 20 Amp.,
Make: L&T, Qty: 02 Nos. (2) Power Contactor (415 V) Main, Rating: 12 Amp., Make: L&T, Qty:
02 Nos. (3) Over Load Relay, Rating: 6-10 Amp., Make: L&T, Qty: 02 Nos. (4) Digital Ameter
(SR-65), Rating: 0-20 Amp., Make: Meco, Qty: 02 Nos., (5) Digital Voltmeter (SR-65), Rating: 0-
500 V, Make: Meco, Qty: 02 Nos. (6) Indicating Lamps (Start,Run,Trip), Rating: 22.5 mm LED,
Make: Airon, Qty: 04 Nos. (7) Push Button (Start,Stop), Rating: 22.5 mm, Make: Airon, Qty: 04 Rupees Nil
Nos. (8) SPP, Rating: 415 V, Make: Space, Qty: 02 Nos. (9) Terminal, Rating: As per Amp.,
Make: Airon, Qty: 04 Nos. (10) Control Wiring, Rating: 1.0 Sq.mm., Make: Any ISI, Qty: Lot
(11) Power Wiring, Rating: As Per Amp., Make: Any ISI, Qty: Lot
Outgoing Feeder (6 Amp. - 01 No.) For Capacitor (1) MCB-FP-10 KA, Rating: 6 Amp., Make:
L&T, Qty: 01 No. (2) Capacitor- MPP Type, Rating: 2 KVAr, Make: Concap, Qty: 01 No., (3)
Rupees Nil
Power wiring, Rating: As Per Amp., Make: Any ISI, Qty:Lot
Outgoing Feeder (32 Amp. - 01 No.) For Lighting (1) MCB-FP-10 KA, Rating: 32 Amp., Make:
L&T, Qty: 01 No. (2) Power wiring, Rating: As Per Amp. (3) Earthing Strip: 25 x 3; G.I. Strip,
Qty: 01 No. (4) MCB-DP-10KA , Rating: 20A, Make: L&T, Qty.:01 Nos. Rupees Nil
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible Submersible
copper cable approved make of following Size. [c] 3 Core x 2.5 Sq. mm
82 20.00 Mtr. 103.00 Rupees One Hundred Three Only
Providing & erecting ISI make medium duty (B class) galvanized MS pipe with coupling,
bend, union, reducer, tee, MS flange etc. with plumbing charges. 50 mm dia. [make and model
83 20.00 Mtr. 260.00 Rupees Two Hundred Sixty Only
approved by EIC strictly as per tender specification]
Supplying and erecting C.I. Swing check type non-return (reflux) valve ISI marked with
packing, flange, nuts and bolts etc.suitable for following pipe size. [a] For 50 mm dia. (Make
84 3.00 No. 1010.00 Rupees One Thousand Ten Only
and model approved by EIC as per specification only)
Lowering of existing submercible motor pump set complete with required No. and size of
pipes by means of proper chain pulley block and pipe wrenches. Job includes stacking of pipes
Rupees Eight Hundred Forty Eight
85 cronologically after the checking of threads. [d] For open well horizontal submercible pump set 2.00 Each 848.00
for sump well. (ii) 1.0 HP to 5 HP
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and fixing of ABC Type Store Pressure Fire Extinguisher Having capacity 6 kg
Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored Pressure
Type, UGTS Pressure Gauge, Can Height 530 mm, Diameter 150 ± 10mm, Discharge Time
Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 92%,
applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can
Construction : Deep drawn & CO2 Mig welded, EPDM(Ethylene Propylene Diene Monomer)
Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating,
External Coating - Pure Polyester Powder coating (UV Resistant),Brass forged CE Marked
valves with NRV & Auto Safety Release with safety Pin is of SS material, Made up from
1.6mm thick sheet, Extinguishers confirmed to IS 15683:2018 and ISI marked. Referance Rupees One Thousand Nine
86 Weight:-Gross Weight 8.9 Kg, Empty Weight 2.9 Kg, 1. Necessary certificate & and guarantee 2.00 Each 1991.00
Hundred Ninety One Only
must be attached, 2. OEM has to provide wall mounting heavy duty bracket/clamp, screw,
hardware for installation. 3.Following printed marking Manufacturing Date and Expiry Date
must be mention on Extinguisher 4. Refilling period must be of 3 Years. Following Printed
marking on equipment must be required:- Model No, Capacity, Gross Weight, Content, Fire
Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with necessary numbering / marking
with oil paint by painter as instructions given by G.S.P.H.C.L engineer] (Make: KANEX,
MINIMAX, CEASEFIRE)
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing and fixing of CO2 type High Pressure Portable 4.5 kg Fire Extinguisher, filled with
Co2 Gas as per IS 15222, Control discharge mechanism fitted with 1 Meter Wire Braided Hose
& Electrical non-conductor Polyethylene Flat Horn with Diffuser Nozzle for dispersed
discharge of CO2, Discharge Time 12 Sec, Average Discharge is 95%, Applicable on Class B, C
and electrically started Fire, Fire Rating 55B, Internal coating is not applicable & External
coating is of enamel spray painting, Powder Coated Handle, Valve Confirm to IS 3224 ISI
Marked, CO2 Cylinder construction: hot spinning by seamless pipes & bearing ISI mark, Body
confirms to IS 7285 and PESO ( Petroleum and Explosives Safety Organization) APPROVED,
Minimum Wall Thickness 4 to 4.2 mm, Extinguishers confirmed to IS 15683:2018 and ISI
marked. Referance Weight:-Gross Weight 16.4, empty weight 11.9 Kg, 1. Necessary certificate Rupees Six Thousand Five Hundred
& and guarantee must be attached, 2. OEM has to provide wall mounting heavy duty Twenty Six Only
bracket/clamp, screw, hardware for installation. 3.Following printed marking Manufacturing
Date and Expiry Date must be mention on Extinguisher 4. Refilling period must be of 5 Years.
Following Printed marking on equipment must be required:- Model No, Capacity, Gross
Weight, Content, Fire Rating, Batch No, Serial no, Mfg Month, Refilling Due. [with necessary
numbering / marking with oil paint by painter as instructions given by G.S.P.H.C.L engineer]
(Make: KANEX, MINIMAX, CEASEFIRE)
Providing & erecting Point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC
insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth
continuity in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed
rigid PVC pipe with PVC fitting fixed with adhesive solution erected on Brick Wall along
with continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe
and boxes shall be filled with cement mortar and finishing the surface to match the wall /
ceiling complete with approved make 5/6 Amp. ISI make modular type switch and accessories Rupees Four Hundred Forty Five
88A mounted in 20 G. G.I. company fabricated metallic box covered with appropriate front plate 10.00 Point 445.00
modules erected flushed with wall / ceiling with necessary modular lamp holder / modular
ceiling rose / HD Connector as directed..(Deep Junction box 75mm depth if required)(Make &
Model approved by EIC and matching colour with switch and accessories) for Open wiring.
Light point. -.(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete CAT III (For Conferance Hall)
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Necessary sheet / tape / polythene / sand must be erected or filled in all box to prevent
mortar going into the box. Length of point wiring must not increase than 10 mtr. For that
necessary switch boards and their locations must be finalised before execution by agency
otherwise payment will not be done for extra long point. (For future extention, if required,
agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost Rupees Nil
of blank plate shall be paid as per tender item) [This item include cleaning (inside/outside) of
all G.I. switch boards, electric point box, fan box, MCBDB & box cutting plaster finishing for
modular plate without any gap]
For Fan Point (with 6 A. Modular type switch and two module hum free EME Five step type
Electronic fan regulator both having ISI mark) with medium class Rigid PVC pipe and Rupees Six Hundred Thirty Two
88B 5.00 Point 632.00
accessories erected flushed on wall/ceiling complete CAT III Only
For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark)with medium
class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete CAT III Rupees Four Hundred Seventy One
88C 3.00 Point 471.00
For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.-
Rupees Two Hundred Fifty Five
88D IlI 6.00 Point 255.00
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured / metallic/white
Rupees One Hundred Fifty Nine
89A front plate , modules erected with necessary connections as per site situation directed by 1.00 Each 159.00
Engineer In charge.TV Co-axial Socket Outlet. Cat.-III
For Modem Jack for Computer Open RJ-45. Cat.-III. Rupees One Hundred Fifty Nine
89B 2.00 Each 159.00
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Providing & Erecting Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x
sq.mm copper PVC insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS
wire for earth continuity in FIA approved ISI mark white colour medium class 20/25 mm
dia. embossed rigid PVC pipe with PVC fitting fixed with adhesive solution erected on brick
wall along with continuous G. I. fish wire to draw wires and laid in approved manner zari for
PVC pipe & boxes shall be filled with cement mortar & finishing the surface to match the wall Rupees Seven Hundred Thirty Eight
90 / ceiling complete with 16 Amp Modular type Swich and accessories mounted in 20 G. GI 3.00 Point 738.00
company fabricated metallic box covered with appropriate front plate modules erected flushed
with wall. (a) 16 Amp Indicator switch & 1 No. 6/16 A universal socket white colour suitable
for 3 pin top duly both having ISI mark. (Necessary Sheet Must Be Erected On All Box To
Prevent Mortor Going In To The Box) Cat.-III
Plug Point wiring with 1.1 KV grade ISI marked approved make 2 x 4.0 sq.mm copper PVC
insulated FRLS wire with 1.5 sq.mm (green) copper PVC insulated FRLS wire for earth
continuity in FIA approved ISI mark white colour medium class 20/25 mm dia. embossed
rigid PVC pipe with PVC fitting fixed with adhesive solution erected in brick wall/slab along
with continuous G. I. fish wire to draw wires and laid in approved manner zari for PVC pipe
& boxes shall be filled with cement mortar & finishing the surface to match the wall / ceiling Rupees Eight Hundred Sixty Three
91 complete with 16 Amp Modular type Swich and accessories mounted in 20 G. GI company 2.00 Point 863.00
fabricated metallic box covered with appropriate front plate modules erected flushed with
wall. (a) 16 Amp switch & 1 No. 6/16 A universal socket white colour suitable for 3 pin top
duly both having ISI mark. (Necessary Sheet Must Be Erected On All Box To Prevent Mortor
Going In To The Box) Cat.-III
Providing & erecting Switch board for Computer or electric apparatus consisting of following
items in single board erected on 20 G. G.I. company fabricated metallic box erected with
appropriate front plate modules erected flushed with wall as directed. 1 no. 6/16 Amp.
Rupees One Thousand One
92 universal Socket, 1 no. 13 Amp. international socket, 2 nos. 16 Amp. indicator switch, 2 nos. 6 2.00 Nos. 1122.00
Hundred Twenty Two Only
Amp. Switch & 2 nos. 6 Amp. 5 pin Plug. For Computer power Supply board. Cat.-III
Supply, Installation testing and commissioning of 16 Gauge M.S. Powder coated floor raceway
Access outlet / service junction box with 16 Gauge M.S. Powder coated Cover plate with duct
entry 25 mm / 38 mm size having epoxy powder coated trap lead with corrosion & rust free Rupees Seven Hundred Forty Nine
with adjustable levelling screw of following size. [a] 300 mm x 300 mm x 50 mm depth Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of specified make Cat - 6 voice /data cable to be done in prelaid PVC pipe / raceway
but without the cost of raceway or pipe ( the wire is to be drawn from MFD/ JB to outlet
94 point) (a) CAT - 6-Y Colour ( For Voice Cabling ) & X -Colour(For Computer Data Cable ) .( 70.00 Mtr. 47.00 Rupees Forty Seven Only
Molex/Avaya/Systimax/Legrand make)
SITC of Indoor Commercial Recess / Surface mounted (IP20) 24 W Cool/Warm white Color
BacklitLED Down lighter office Lighting Luminaire with separate potted driver with single
piece pressure die cast aluminium alloy housing with corrosion resistant powder coated finish
with PMMA/PS/Injection moulded Polycarbonate diffuser with high brightness LED
complete, CRI > 80, with 24 W. The LED's should be mounted on metal core PCB for better
heat conduction and long life of LED. The Fixture should comply all International Standarad
third party (LM 79 for complete fixture, LM80 for individual LED). The Fixture have protection
like miswiring, over voltage, over load, wrong wiring, THD < 15%,, P.F > 0.95, efficacy >
lm/w & driver efficiency > 85%. For 24 W fixture wide voltage range from 160 V to 270 V,
50/60 HZ @ 240V application, 2 KV surge protection.The fixure must have min. 2160 lumen
light output.The fixture should be provided with external separate Potted driver, latest Valid Rupees Seven Hundred Fifty One
BIS approved Luminaire and driver. The Fixture efficacy > 90 lumens/watt only for safety and Only
performance. (L70 @ 30,000 Hrs.) The fixture should be able to easily mount on POP / Grid
false ceiling. The Luminiare should be tested as per IP 20 and following test reports should be
submitted at the time of approval: heat resistant test, thermal test, Ingress protection test, drop
test, Photobiological report with 3 core X 1.0 Sq.mm. flexible wire as per site requirment [Note:-
The manufacturer / authorized Channel partner of the manufacturer has to submit 5 yrs. free
replcement Guarantee for complete Fixture]
Providing and erecting Inverter based approved make split air-conditioning unit consisting of
condensing unit with variable speed fan motor, inverter type hermetically sealed rotary
compressor with accessories etc. duly connected separately erected evaporating unit and
blower motor with its accessories by means of extra supplied proper insulated copper Rupees Fifty One Thousand One
96 tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A 2.00 Each 51155.00
Hundred Fifty Five Only
plug top & Remote Control & MS Stand) with necessary core cutting.(1)For ISEER Range
(KWH/KWH)(3.1 to 3.99) for 2 ton capacity( Make &Model Approved By EIC)
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
Extra charges for the item of copper tubing with minimum 19 mm thick class 0 nitrile rubber
insulation for entire piping system exposed refrigerant piping should be additionally insulated
with factory laminated 200 GSM glass coth for UV and mechanical protection and
manufacturer accomoded adhesive ( solvent free ) sealant applied at all joints (including
Refrigerant Joint) UV protection layer. additional layers of UV paint over GC for all exposed to Rupees Nine Hundred Fifty Six
atmosphere piping for weather protection of pipes & insulation and prevention of rain Only
waterigress. item beyond standardlength for single phase / three phase Split A.C. Machine /
Cassate A.C. Machine including power and control cable up to 4.0 TR capacity.
Supplying and laying UPVC cable trunking system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and flame proof confirming BS with necessary end
caps Internal and external bend, flat bends, coupler, tee etc..All necessary accessories and Rupees Four Hundred Twenty Four
measuring of following sizes. FOR 100 mm x 50 mm trunking Only
SITC of of 2Dual-channel power amplifier 2 x 240W 100V Lightweight class-D amplifier
Advanced protection circuit XLR input & linkthrough connections with gain control & HPF
switch Terminal block output connections High-pass filter switchFrequency Response (± 3 dB)
50 Hz - 22 kHz Signal / Noise > 100 dB Technology Class-D Power Supply Switching mode
Source 230 ~ 240 V AC / 50 Hz Inputs Sensitivity -0.5 dB ~ 10.5 dB Impedance 10 kΩ balanced Rupees One Lakh(s) Six Hundred
99 Connector XLR female with Male Linkthrough Outputs Voltage / Impedance 100 V / 42 Ω 1.00 Each 100606.00
Connector 4-pin Euro Terminal Block (Pitch - 5.08 mm) .
[Make:- Audac / Workpro Zenith 1000 / EAW / Bose and equivalent make and model
approved byt EIC Only]
SITC of Column loudspeaker 40W, metal, black.
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Rupees Twelve Thousand Three
100 [Make:- Workpro NEO 5 / Bose / Martin Audio and equivalent make and model approved 6.00 each 12349.00
Hundred Forty Nine Only
byt EIC Only]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of Handheld Wireless Mic with Cardiod polar pattern,Dynamic microphone ,frequency
response 80Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and
receiver having 30 or more channels possible,S/N ratio >100dB A,dynamic range >95db
B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA
battery.The transmitter & receiver should be of metal body (Including Five year free Rupees Sixty Seven Thousand Six
maintenance with guarantee) Hundred Thirty Only
[Make:- Erhtpot AR-31 / Clock Audio / Brahler,and equivalent make and model approved
byt EIC Only]
Supply,Installation,Testing and Commissioning of 30 ft HDMI Interface Cable
Should be 30ft Male to Male High-speed Category 2 HDMI cable; Should be 24k
gold-plated 19-pin Type A connector; Should have High-flex CL3-rated jacket;
Should Support 4K30 4:4:4 and 4K60 4:2:0 video; Should support 18 Gbps
Rupees Fourteen Thousand Four
102 bandwidth; Should be RoHS compliant (Including Five year free maintenance 3.00 Each 14407.00
Hundred Seven Only
with guarantee) [Make:- MX / Kramer / Extron / and equivalent make and
model approved byt EIC Only]
Supply,Installation,Testing and Commissioning of 3 ft HDMI Interface Cable
Should be 3ft Male to Male High-speed Category 2 HDMI cable; Should be 24k
gold-plated 19-pin Type A connector; Should have High-flex CL3-rated jacket;
Should Support 4K60 4:4:4 video; Should support 18 Gbps bandwidth; Should Rupees Four Thousand Two
be RoHS compliant (Including Five year free maintenance with guarantee) Hundred Thirty Seven Only
[Make:- MX / Kramer / Extron / and equivalent make and model approved byt
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of 3LCD Lamp based projector having wxga (1280x800) or better
resolution with minimum white brightness of 3800 lumens and color brightness
of 3800 lumens. The projector should have minimum 1HDMI,1VGA input.
Having contrast ratio of 15000:1 or more. the projector should have auto vertical
key stone correction of +/- 30 degree and Manual Horizontal of +/-30 degree.
the projector should have optical lens, throw ratio 1.30-1.56:1. Zoom Factor of
1.2. Lens focus Manual having focal length 16.9mm to 20.28mm. projector Rupees Thirty Three Thousand Five
104 should have features like AV mute slide, quick corner and split function and 1.00 Each 33560.00
Hundred Sixty Only
should support wireless functionality with inbuilt wifi or wifi dongle.
[Approved by Competent Authority i.e. not Below the rank of Executive
Engineer ] (Make : Epson / Sony / Panasonic and equivalent make and model
approved byt EIC Only)
SITC of 120 inch Diagonal Self Lock MW Instalock Slow Retraction Screen,
Rupees Five Thousand Two
105 Aspect Ratio-16:9 1.00 Each 5282.00
Hundred Eighty Two Only
SITC of universal Projector mounting kit, with necessary grouting, fasteners etc.
with adjustable height and suitable for all types of projectors. [Approved by
Rupees Six Thousand Seven
106 Competent Authority i.e. not Below the rank of Executive Engineer ] 1.00 Each 6781.00
Hundred Eighty One Only
SITC Hydrolic popup box with HDMI , VGA , with audio 3.5 mm jack , lan
AMP power. (Make and model approved bhy EIC Only) (Including 3 years Rupees Eight Thousand One
warranty) Hundred Eighty Six Only
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC Mono Audio/Control Cable, is a high−quality shielded pair cable
designed for routing balanced mono or unbalanced stereo mic or line level
audio signals in commercial or residential AV systems. Conductors and drain
wire are stranded 20AWG tinned copper With sequential markings every meter..
Exceptionally easy to strip because the foil shield is bonded to the inside of the Rupees One Hundred Twenty Two
jacket., with white colour medium class PVC pipe , As directed By Engineer In Only
charge[Make:- MX / Kramer / Extron, and equivalent Make and model
approved bhy EIC Only)]
Providing and erecting 4 x 2 HDMI matrix switcher ,4 HDMI inputs & 2 HDMI
outputs ,Max. resolution 4K@60Hz (4:2:0) & 4K@30Hz (4:4:4) HDMI ,support
max. resolution 4K@60Hz (4:2:0) & 4K@30Hz (4:4:4)HDMI Suppot Color, 3D,
ARC, up to 7.1 uncompressed audio channels , Data rate up to 8.91 Gbps
,reclocks and equalizes the signal ,standards Compliance: HDMI 1.4 and HDCP
Rupees One Lakh(s) Seven
Thousand Two Hundred Eight Only
or last connected input ,Flexible control options viz Front Panel, Ethernet with
built-in webpages & RS-232 erected as directed by engineer in charge[Make:-
KRAMER / AMX/ EXTRON / CRESTRON,and equivalent Make and model
approved bhy EIC Only)
Supply and installation of 19 U Equipment steel rack Floor mounting for
installing Amplifier,Scalar, Wireless mic receiver etc, rack should be fully
enclosed steel housing fabricating with powder coated with glass doors and
having wire nos. wire management system . the rate includes the exhaust fan 2 Rupees Twenty Four Thousand One
nos, 6 Sockets and 1 switch power strip and all the wiring in the rack.. (Including Hundred Fifty Three Only
Three year Warranty) [ Make: Elixir / Rittal / Valrack]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC 2 Core Speaker Cable , is a high−quality 99.999% OFC Résistance :
Ω/m Capacitance : 55,530 pF/m, Section : 2x1,5mm2 Dimensions
:415x160x215mm , Cable as comfortable with micro-information as they are with
high power twisted pair cable designed for connecting speakers and amplifiers .
111 100.00 Mtr. 72.00 Rupees Seventy Two Only
( Make- MX , Norstone , Belden , Kramer,and equivalent Make and model
approved bhy EIC Only)
Supplying & erecting Mixing Console having channels, Audio mixer with. Echo facility for live
performance, Auditorium & stadiums, having following features & facilities. [[Approved by
Competent Authority i.e. not Below the rank of Executive Engineer ] (a)input Channels :- Each
channel has separate 6.25mm size balanced phone jack for mike & line for balanced &
unbalanced signals.(b)Individual gain control for sating optimum level for minimum noise.
(c)BASS, MID & TREBLE ‘ controls Separately for each input channel.(d)ECHO control for
each channel (e)PAN control for echo channel for left or right output(f) AUX Control : To
control , level of the channel in final mix to AUX sound output(g)Channel ON/OFF
switch(h)ECHO Section :- ECHO, reverb & Chorus effect can be added to all input channel by
different setting of Delay, Reverb & Level control.(i)Tape section (j)Aux. send & return For
sending Pre-feeder output of channel for monitoring or adding a special effect unit.(k)Mono /
Stereo output controls(L)Master faders to control over left & right (m) Head phone output for
Rupees Twelve Thousand Two
112 monitoring purpose.Technical specification:(a)Power Requirement -AC220-24OV 50 Hz DC 1.00 Each 12289.00
Hundred Eighty Nine Only
24 Volts (b)MIC Output Impedance/gain -2 K Ohms/ 62 dB (c)Line Output Balance/42
dB —- 20 K ohms (d) Impedance / Gain :- 10Kohms unbalance / 42 dB (e)frequency
Response - 30 Hz- 20 KHz L / R Line Output ( + 0, -1 dB ) (f)Equalization Bass/ - + / -
12 dB at 100Hz Mid / Treble 2 KHz / 10 KHz (g) Outputs, Line Output Line Output Low
: -10 dB / -2 dBM Line Output High
: 0 dBM / +17 dBM (775 mv / 5.5 V ) (h) S/N ratio Line Output Level : > 70 dB (0 dB,
0.775V) The Console shall be mounted on standard Rack, The channel of following
numbers.(B) 9 Channel Audio Mixer with ECHO
[Make:- Studiomaster / Ahuja / Behringer and equivalent Make and model approved bhy EIC
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of Delegate Unit shall enable delegates to speak and listen to the
proceedings via a loudspeaker or headphones. The unit shall include a
microphone with a red indicator ring, which shall illuminate when the
microphone is on.
The unit shall include a ‘Possible To Speak’ white LED indicator, which shall
illuminate showing the delegate when it is possible to switch on the
microphone.To prevent acoustic feedback, the built-in loudspeaker shall be
muted when the microphone is on, and/or the headphones are connected.Two
3.5 mm stereo headphone sockets (wired for mono) shall allow two pairs of Rupees Thirty One Thousand Seven
headphones to be connected, enabling two delegates to simultaneously use the Hundred Seven Only
The headphone volume level shall be adjustable on the unit for maximum
comfort. It shall also be possible to connect a tape recorder to one headphone
socket, and use the other headphone socket to listen to the proceedings.
[Make:- Erthpot NCS-5D / Brahler / Telvic,and equivalent Make and model
approved bhy EIC Only.]
SITC of Chairman Unit shall enable the user to function as chairman of a
conference or meeting. It shall be similar in appearance to the Delegate Unit, and
shall also include a ‘chairman priority button.When pressed, the priority button
shall cause all currently active delegate microphones to be temporarily or
permanently muted, allowing the chairman to take control of the meeting.To
prevent acoustic feedback, the built-in loudspeaker shall be muted when the Rupees Thirty Eight Thousand
microphone is on, and/or the headphones are connected.An optional chime Three Hundred Forty Three Only
Brahler / Telvic,and equivalent Make and model approved bhy EIC Only)]
Item Qty. Unit Estimated Rate [Rs. Ps.] Amount
Description of Item
No. InFigure In Words Rs.
SITC of Control Unit shall have features for managing the number of active
microphones and determining the operating mode, without the need for a
central operator, should be available. It shall be possible to control up to
delegate units and power up to 50 delegate units.It shall be possible to connect
external equipment to extend the system capabilities. There shall be a built-in
Rupees Ninety Four Thousand Two
115 loudspeaker and headphone connector to allow the conference to be monitored 1.00 Each 94226.00
Hundred Twenty Six Only
by, for example, a stenographer.
[Make:- Erhtpot NCS-110U / Brahler / Telvic, and equivalent Make and model
approved bhy EIC Only.
Ele Amount
Total Amount
Total Amount
Exeucutive Engineer
Signature of Contractor G.S.P.H.C,Limited.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02 specification para.pdf
03 section 5.1 Genral Techinal Specification CIVIL_ 24-3-23.pdf
04 attached specification.pdf
05 Schedule B.pdf
Document
07 ELECTRICAL BOOKLET.pdf
01 SBD RAJPIPLA STP.pdf
NIT-22 [2025-26].pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .