Executive Engineer
Executive Engieer Jal Shakti Division Mandi
Improving Sustainability and Resilience of WSS Mandi Town by Providing Supplying and Fixing of 7.50 HP 12.50 HP 12.50 HP 25.00 HP and 15.00 HP Submersible Pump Set along with its allied accessories at various Places Under AMRUT 2.0
2024_HPIPH_88789_1
1641-90
Open Tender
Pumps/Motors
Item Rate
90 days
MAndi Town
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
Yes
₹37,400
Yes
1 Jul 2024
7 Jun 2024
18 Jun 2024
7 Jun 2024
17 Jun 2024
7 Jun 2024
Amount
Providing & Fixing Submersible Pump Set (water filled) of following mentioned HP standard make such as Kirlosker / KSB /Crompton conforming to ISI code - 8034-1976 with upto date ammendments. The pumpset should be capable of handling head mentioned below with (+) 10% (-) 15% head range and it should be operationable with 415 volts single phase A.C. supply in all leads and lifts. 7.50 HP (Head 176.96 meter & Discharge 1.76 litre/sec. 1st Stage)
12.50 HP (Head 208.62 meter & Discharge 2.40 litre/sec. 1st Stage)
12.50 HP (Head 80.17 meter & Discharge 6.17 litre/sec. Booster Stage)
25.00 HP (Head 177.30 meter & Discharge 6.17 litre/sec. 1st Stage)
15.00 HP (Head 187.42 meter & Discharge 3.59 litre/sec. 1st Stage)
Providing and Fixing of GSM operated control panel consisting of Amp meter, Volt meter, Inbuilt DOL Starter up to 7.5 HP & Automatic star delta starter for above 7.5 H, with MCB, Shunt capacitor capacitor complete with internal wiring for operating above set with MCB / MCCB in main for Isolation of circuit . NOTE:- The panel shall be from top manufacturers of Siemens / L&T / Havells make complete in all respects (locally manufactured not acceptable)
Providing and Fixing of M.S. angle iron frames complete with steel sheet fabricated enclosures for housing of energy meter as well as control pannel for operating complete having door on front with locking arrangement from front side complete in all respects in all leads and lifts.
Providing and Fixing Three Core flat water proof Copper Cable of Havells/KSB/Finolex makes. having following sizes suitable for running of motors of following capacity in all leads and lifts. Size 1 x 3 x 4.00 sq mm ( as per requirement for running motor up to 7.50 HP = 4.00 sq.mm)
Size 1 x 3 x 6.00 sq mm ( as per requirement for running motor of 10.00,12.50 & 15.00 HP = 6.00 sq.mm)
Size 1 x 3 x 10.00 sq mm ( as per requirement for running motor of 20/25 HP = 10.00 sqmm size)
Providing and Fixing Holding Wire (Heavy Duty) complete in all respect in all leads and lifts.
Providing and fixing of Cast steel ASA 150 class Sluice Valve having seat test pressure of 21 Kg/sq.cm of make Kirloskar, Leader, Pelican, KSB etc. conforming to API 600 specifications equal to dia of rising main folloeing mentioned dia in all leads and lifts. 50 mm diameter Flange Table-5
65 mm diameter Flane Table-5
80 mm diameter Flange Table-5
Providing and fixing of Cast steel ASA 150 class Non Return Valve having seat test pressure of 21 Kg/sq.cm of make Kirloskar, Leader, Pelican, KSB etc. conforming to API 600 specifications equal to dia of rising main folloeing mentioned dia in all leads and lifts. 50 mm diameter Flange Table-5
65 mm diameter Flane Table-5
80 mm diameter Flange Table-5
Providing GI plate earthing for all above pumping sets ( 2Nos. Per site) conforming to IS:3043 latest amemendments)
Laying, jointing and testing in trenches GMS pipe of following dia meters conforming to BIS:1239 (Part-1) of following mentoned grade, diameter and having wall thickness as specified below with plain end and capable of withstanding required pressure in randoum length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest upto date amendments) duly wleded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standared alongwith nuts and bolts of required sizes, 3mm thick cmpressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respedcts to the satisfaction of the Engineer-in-charge. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made from parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminopus paint over a priming coat as per AWWA specificatioins C-203-1979. The welding electrodes shall be as per IS: 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of the Engineer-in-charge within all leads and lifts . (Earth work in trenches will be measured and paid for separattely 50 mm diameter (MG) Flange table 28
65 mm diameter (MG) Flange table 28
80 mm diameter (MG) Flange table 28
KARTIK MAHAJAN
M.V.Associates
TECHPRO ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .