Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 CrAccepted-AOC | ₹22.0 Cr | L1 | Accepted-AOC agt executed |
Tender Value
₹20.9 Cr
EMD Value
₹5 L
Closing Date
1 Nov 2024, 4:00 pmClosed
Superintending Engineer
KWA, P H Circle,Muvattupuzha
Construction of 9 M dia well cum pump house, Supply and Laying of 600 mm DI Raw Water Pumping Main, Supply and Erection of 400 KVA Transformer, Raw Water Pump set etc at Thopilkadavu
2024_KWA_698783_1
Re-64/2024-25/SE/PHC/MVPA
Open Tender
Civil Works - Water Works
365 days
KWA PH CIRCLE MUVATTUPUZHA6
AS per NIT
10 documents required · 10 mandatory
₹16,540
Yes
₹5 L
Yes
KWA, P H Circle,Muvattupuzha
18 Jan 2025
22 Oct 2024
2 Nov 2024
22 Oct 2024
1 Nov 2024
22 Oct 2024
22 Oct 2024 - 25 Oct 2024
26 Oct 2024
Amount
9M DIA WELL CUM PUMP HOUSE
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.7.3:Bailing out water with engine and pump set above 10HP up to 20HP including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.3.7.1:Earthwork in open well excavation (above water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.7.11:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift up to 1.5m including neat banking.
100.3.7.12:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 1.50m to 3.0m including neat banking.
100.3.7.13:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 3.0m to 4.5m including neat banking.
100.3.7.14:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 4.5m to 6.0m including neat banking.
100.3.7.15:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 6.0m to 7.5m including neat banking.
100.3.7.16:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 7.5m to 9.0m including neat banking.
100.3.7.17:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 9.0m to 10.50m including neat banking.
100.3.7.18:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 10.50m to 12.00m including neat banking.
100.3.7.19:Earthwork in open well excavation (in or under water) for wells of diameter above 6.0m and up to 9.0m in all kinds of soil and conveying and depositing the spoil within initial lead of 50m and lift from 12.00m to 13.50m including neat banking.
OD71306/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 13.50m (12.0m to 13.50m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD71307/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 15.00m (13.50m to 15.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD71308/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 16.50m (15.00m to 16.50m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD71309/2024-2025:Granite rock blasting in wells, measured in solids, including collecting and stacking spoil for measurement within the initial lead of 50m and lift up to 18.00m (16.50m to 18.00m) but excluding bailing out water and including providing protection by earth filled cement bags (300 Nos. of earth filled cement bags / 10 m3 blasting) to avoid damages to the nearby structures)
OD71310/2024-2025:Rubble packing with hard stone in foundation, including leveling as per directions with available stone at site
OD71311/2024-2025:Dry rubble masonry with hard stone in foundation and plinth including levelling up to plinth level
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level
5.9.12:Centering and shuttering including strutting, etc. and removal of form for:Well steining
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.11.1:Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.23.1:Extra for plastering on circular work not exceeding 6 m in radius.In one coat
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
50.9.3.1:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
10.5.1:Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
9.63.2:Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete:200x10 mm
OD71312/2024-2025:Pad lock 7 lever approved qualit
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.
100.37.14.2:Fabricating M.S. flanges of diameter 600mm using 16mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.98.492:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 600mm.
10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
OD71313/2024-2025:Providing and erecting Gantry girder crane of 3Tonn Capacity, Including all cost and conveyance charges
OD71314/2024-2025:Supplying chequered plate 6mm thick including cost and conveyance
OD71315/2024-2025:Providing and fixing vertical rod for operating valve using 25mm dia MS rod including cutting the rod to the required length,welding one end to the valve spindle,providing wheel on other end so as to operate from platform as and when required etc complete.
RAW WATER PUMPSET
RAW WATER PUMPING MAIN
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.2:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.1.6:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Ordinary Rock.
100.2.7:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.2.8:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5m but not exceeding 3m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in Medium Rock where Blasting is Prohibited.
100.59.1:Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffic diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.
100.14.10:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 600mm diameter Ductile Iron Class K-9 Pipes.
100.14.4:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 250mm diameter Ductile Iron Class K-9 Pipes.
18.70.10:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:600 mm dia pipes
18.70.4:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes
OD71289/2024-2025:Labour for cutting D.I. pipe with steel saw.600 mm diameter D.I. pipe
OD71290/2024-2025:Labour for cutting D.I. pipe with steel saw.250 mm diameter D.I. pipe
100.35.10:Testing 600mm DI/CI pipeline with potable water to the required test pressure. 600 mm dia Observed Data derived from item no.1029 of PHED DATA
100.31.2.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class II.
100.31.2.6:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 250mm diameter, Class II.
100.31.2.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class II.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.9.1:Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock
2.26.2:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.16.2:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsAbove 20 cm wide
100.98.1008:Engaging Coolie.
100.37.21.1:In situ fabrication of M.S. pipes of size 600mm (I.D.) using 10mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
OD71291/2024-2025:Fabricating MS flanges of diameter 600 mm using 20 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 10mm thick MS plates
100.37.21.3:Cutting 600mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.37.21.4:Welding 600mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.37.21.5:Grinding cut and weld edges of 600mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 10mm thick M.S. plates.
100.98.124:Supply of DI K9 Pipe Conforming to IS 8329/2000, 600mm Dia.
100.98.118:Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia.
100.98.437:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Kinetic Air Valve Type DK, Size 100mm.
100.98.468:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 600mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.462:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 250mm.
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
400 KVA TRANSFORMER
OD71254/2024-2025: 500 KVA Transformer - Supply, installation, testing and commissioning of one number 500 kVA, DYn11, 3Ph, 50Hz, 11 KV/433 V,ONAN cooled, copper, wound indoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The LT side shall have cable end box for XLPE cable. The transformer shall have suitable enclosure for The LT side. The transformer shall be complete with all standard accessories and fittings & conform to IS:2026. The rate shall be inclusive of all materials, lead, lift, first fill of oil, and necessary civil works for mounting to the existing transformer foundation complete as per single line schematic diagram & particular specifications.
OD71255/2024-2025:Supply and providing MS ladder type cable try and supports made out of suitable size MS angles/ flats etc. including painting with 2 coats of enamel paint over 2 coats of red oxide primer.
OD71256/2024-2025:Fabrication, supply and erection of 11 KV 4 pole structure as per standards made out of ISMB 200 x 100mm joist of 10mts. Length and cross members of ISMC 100x50 mm MS channels and fitted with following equipments '0' SWG solid copper conductors shall be used for all jumber connections from suppliers AB switch to transformer through various equipments , the post has to be fixed 1.60m below ground level using 1:3:6 cement concrete as per standard including painting with 2 coats of epoxy 300x300x6mm MS plate shall be welded to all poles as base plate including fixing suitable bolts and nuts etc.complete and the pole structure consist the following: a)11KV 400A 3 pole 3 insulator type gang operated AB switch with operating rod and handle with pad lock arrangements - b)11KV 30/60A 3 pole DO fuse with element -c) 9KV 5KA Lightning Arrestors d) 11KV disc type insulator with all hardwares. - e) 11KV pin type insulator
OD71257/2024-2025:Fabrication, supply and erection of fencing for transformer yard up to a height of 2.0 m using 2.5m long 40x40x6 mm angle supports at 1.2 m interval erected in ground 0.5m below and 2.0 above ground level the bottom portion grouted on 1:3:6 cement concrete, providing necessary length 25x6 flat iron horizontals at 80cm intervals, and providing 10 mm MS rods vertically fitted at 10 cm interval and chain link fabric fencing mesh of size 50x50mm made of G.I. wire of dia 4 mm.all around the yard fixed on the frame work including excavation of soil, levelling, painting 2 coats of aluminium paint over 2 coats of epoxy and spread 40mm broken granite gelly over spreading a layer of sand in the yard as per standards
OD71258/2024-2025:Supply and fixing of 2 m x 1.8m size gate with 40X40X6mm angle frame with 3 Nos MS flat central cross support of 25X6mm flat iron and 10mm rod as vertical welded with 10cm apart to the gate frame hinged to the existing fencing pole, providing locking arrangements and painting 2 coats of aluminium paint over 2 coats of epoxy primer
OD71259/2024-2025::Supply, erection , testing , commissioning of outdoor oilfilled CTPT unit with bushing as per KSEB standard consist of the following CT ratio--/5A 15 VA class .2 S CTs Nos 11 KV/110V 100VA 0.2S Class PT:1no. CTPT unit as per KSEB standards and including testing at KSEB TMR unit
OD71260/2024-2025:Supply, erection , testing , commissioning of -/5A, class 0.2S, 4 wire HT TOD meter with CRCA sheet weather proof Kiosk with locking facility and base frame as per KSEB specification. The rate should include cost of fee and other incidental expenses for testing TOD meter
OD71261/2024-2025:Conveying and fixing of Transformer 500 KVA 11KV/433V outdoor copper wound oil filled transformer (KEL/TELK/BHEL make) with first fill oil off load tap changer (+)5 to (-)10% in steps of 2.5%. HT side rbushing and LT side cable box suitable for XLPE cable termination and construction of suitable R.R masonry plinth for accommodating transformer etc. as per IS specification
OD71262/2024-2025:Supply, erection, testing and commissioning of Neutral CT 150 5A 15 VA 5P10 in weather proof<br>MS panited enclosure with hinged cover
OD71263/2024-2025:Supply and providing plate earthing as per IS 3043 with 1200x1200x12 mm GI/CI earth plate, 50 mm GI watering pipe fixed to the earth plate with 25 x 3mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 450 x 450 x 450 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
OD71264/2024-2025:Supply and providing pipe earthing as per IS 3043 by using 3 meter long 40mm size 'B' class GI pipe. Providing 1 No earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top.Filling charcoal and salt at alternate intervals.providing masonry earth pit chambers of suitable size and covering with RCC/CI chamber cover etc complete
OD71265/2024-2025:Supply and providing pipe earthing as per IS 3043 with 2.5 m long 40 mm dia B class GI pipe, GI funnel with weld mesh, filling required quantity of charcoal & salt including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top.
OD71266/2024-2025:Supplying and fixing cable route marker with 10cmx10cmx5mm thick G.I.plate with inscription there on,bolted /welded to 35mmx35mmx6mm angle iron,60cm long and fixing the same in ground as required
OD71267/2024-2025:Supply and providing following safety items. 6 mm thick rubber mat 0.90 m wide 1.80 m long ISI marked- 3 nos, DCP type fire extinguisher 5 kg (ISI marked) - 2 nos, CO 2 type fire extinguisher 5 kg (ISI marked)- 2 nos, fire bucket with floor mounting self stand - 2 nos, shock treatment chart duly framed with glass cover - 2 nos, 11 KV gloves - 2 pair, danger baord - 6 nos, first aid box with medicine - 1 box,earth rod of 3. m long 1no etc.
OD71268/2024-2025:Charges for preparation of electrical scheme and getting energisation approval (including clearing defects if any) from electrical inspectorate.Statutory fee excluded from the cost (statutory fee shall be done by KWA)
OD71269/2024-2025:MSB- Fabrication of fully partitioned in door self standing cubical type dust and vermin proof enclosure for panel assembly as per 4 of IS 8623 using 2.00 mm CRCA sheet as per approved design and requirements with front access facility, bus bar chambers, hinged door for all switch gear compartment earthing the door using 4 sq mm braided copper conductor providing necessary cutout for mounding meters, relays ,indication lamps ,bus bar inter connections etc detachable cover for bus bar chamber and cable alley, powder coating in the assembly after subjecting to 7 tank process etc as required . CRCA sheet alone to be use for the fabrication. Angles ,flats, slotted angles etc shall not be used for the panel assembly .with 800A ACB as incomer-1No with 3O/C and E/F releases and stand by earth fault relay, 400A TPN SFU -3Nos , 125A TPN SFU -2Nos as Outgoings .Switch board should have suitable rated TPN copper bus bars with specified current ,flort level and insulated with SMC/DMC bus bar support, color coded lead ould be have 6 mm thick FRP shrouding wherever required as per electrical inspectorate specification .
OD71271/2024-2025:Supplying and laying of 25x5 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD71272/2024-2025:Supplying and laying of 25x3 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD71273/2024-2025:Supplying and laying of 6 SWG copper wire conductor along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD71274/2024-2025:Transportation ,erection testing and commissioning of MSB 1 no.,SSB 2 nos,MCC 4 nos,LDB 2 nos
OD71275/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point ( rate as per SI 120a1)
OD71276/2024-2025:Supplying and fixing yard lighting with GI pole and LED light
OD71277/2024-2025:Supplying and laying following size of 1.1KV PVC insulated and armoured heavy duty aluminium cable as per IS through built in trenches/ cable trays including clamping 3.5CX240sqmm
OD71278/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3C x 185 Sqmm
OD71279/2024-2025:Supplying and wiring points according to IS 732 is using rigigid pvc pipes using 1sqmm FR PVC insulated stranded single core copper conductor etc. complete as per sepecification (Sl no. 120) single control light point with 6 A 5 pin plug ( rate as per SI 120a3)
OD71280/2024-2025:Supplying and laying one number PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade folloewing size in masonry open duct as required (S&L of 3x2.5 sqmm copper armored cable)
OD71281/2024-2025:Supplying and laying of following size of 1.1 KV grade PVC insulated armored heavy duty aluminium cable as per I S through built-in trenches/ cable trays including clamping 3.5 x 95 sq mm ( two run)
OD71282/2024-2025:Supplying and laying one number PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade folloewing size in masonry open duct as required (S&L of 3x70sqmm copper armored cable) (Two run)
OD71283/2024-2025:(cabling )supply laying testing and commissioning of the following size.PVC XLPE insulated shelthed armoured aluminium conductor cable 1100 /11000 volts grade clamped on wall / cieling with Clamps and saddle clips partly laid in cable tray partly laid in trench for 16 sq mm PVC XLPE aluminium cable
OD71284/2024-2025:Supply and installation of sheet steel phosphatised and painted dust and vermin prof enclosure of MCB DB 8 way including copper /brass bus bar nuetral link earth bus and DIN rail suitable for fixing MCB isolator etc. fixed on wall using suitable anchor bolts or recess including cutting hole on the wall making good the damages colour washing etc. as required 8 way single phase double cover(IP 42/43)
OD71285/2024-2025:supply and wiring light points with 6A plate ceiling of according to various 732- 1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 3419 -1988 fixing the conduit using methyl saddles spacing not exceeding 50cm concealed suitably and with 1 sq mm FR PVC insulated standed single core copper conductor cable 650 B grade including providing switch board main and continuous earthing earth socket brass Bolt and nuts crimpling soldering etc compete with suitable size modular type of metal switch boxes modular type of front plates (white) etc up to and including 6A modular type SP switches and making good the surface of wall colour washing etc complete all the terminations in switich boards and the DB"s shall be tinned and wires shall be drawn and fixied along the Periphery of the box using suitable Ties tie mounts etc. as require
OD71286/2024-2025:Supply, conveyance and installation testing and commissioning the light fittings of 1200 mm 1-20 w LED lamp with box type fluxure made from CRCA sheet 0.5 mm thickness with all accesseries and lamps directly on wall and giving connections with 16/0.2 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD71287/2024-2025:Supply,Laying,Testing and Commissioning of following sizes of MV(1100V) cables XLPE Aluminum cables as per IS. standards 3.5x300 Sq. mm ( transformer to MSB, MSB to Pump control panel)
OD71288/2024-2025:end terminations 3.5 core 300Sq.mm. 1100V AYFY Cable
TOILET UNIT
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
13.7.2:12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
11.37:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
11.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
18.1.4:Providing and fixing Polyethelene - Aluminium - Polyethelene ( PE - AL- PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80?C including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) eg. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes testing of joints complete of joints complete as per direction of the Engineer -in-Charge. Internal work - Exposed on wall2532( 32 mm OD ) pipe
18.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
17.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
50.18.8.8.2:Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
50.18.9.21.7:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
9.143:Providing and fixing factory made uPVC door frame, made of uPVC extruded section, of size 65 mm x 55 mm with wall thickness 2.0 mm (? 0.2mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm ( ? 0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.
9.144:Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm ( ± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (± 02. mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer -in- charge.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
BRIDGE
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
5.37.1:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All wiork upto plinth level
5.37.2:Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in -charge. Note:- Cement content considered in this item is @330 kg/cum. Excess /less cement used as per design mix is payable/recoverable separately.All work above plinth level upto floor V level
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
10.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.44.1:Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD71248/2024-2025:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, , spreading, leveling keeping gradient of road etc for lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
16.2:Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density ( proctor density)
16.78.1:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
RETAINING WALL,COMPOUND WALL AND GATE
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
13.33.2:Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Raised and cut pointing
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
13.4.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
16.18.1:Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for serarately) :- Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
13.50.3:Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
HDPE PIPE LINE
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
OD71292/2024-2025:Extra Charges for excavating trenches of required width for pipes, Including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating<br>each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m All kinds of soil (Ref. Item No. 2.10.1 of DSR)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
100.10.17:Laying HDPE pipes (IS : 4984) on land portion including conveying within initial lead and aligning the pipes, electro-fusion welding using automatic or semi-automatic electrofusion machines, testing the pipeline thus fabricated to suit the hydraulic working pressure and after testing, aligning the pipeline, lowering the pipe in position into the trenches already made, testing the line to suitable pressure with potable water before back filling and levelling the trenches including all labour charge, hire for appliances etc., complete but excluding cost of pipe and fittings: 630mm Nominal Outside Diameter Pipes.
10.20:Providing and fixing bolts including nuts and washers complete.
100.98.480:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 600mm.
100.98.451:Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm.
100.31.1.12:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 600mm diameter, Class I.
100.32.5:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 100mm Double Acting Air Valve.
100.98.190:Supply of HDPE Pipe PE 100 (IS 4984/1995), 12.5kg, 630mm Outer Dia.
LSGD ROAD RESTORATION
3.5.1:Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
4.1.A.1:Granular Sub-base with Well Graded Material (Table 400.1) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material
4.9:Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
75.5.1.1pb:Prime Coat - Low porosity - With Packed Bitumen Rates Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
75.5.2.3pb:Tack Coat - With Packed Bitumen Rates Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.9.1.2a:20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (II) Bitumen (S-65)
5.12.A.3.2a:Seal Coat - Manual Means - Type C - Bitumen S-65 Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 A. By Manual Means :- Case - III : Type C (II) Bitumen (S-65)
OD71293/2024-2025:Providing concrete for plain/reinforced concrete, using 40 mm graded brocken stones (Form work excluded, Cement content changed to 170kg/m3) I.P.C.C grade M10 (i) Nominal mix 1:3:6
OD71294/2024-2025:Providing concrete for plain/reinforced concrete, using 20 mm graded brocken stones (Form work excluded, Cement content changed to 320kg/m3, 40mm aggregate excluded 20mm-0.54m3 and 10 mm -0.36 m3 ) P.C.C grade M20 (i) Nominal mix 1:2:4
OD71295/2024-2025:Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
OD71296/2024-2025:Filling with Quarry Muck Filling up low lying and water logged areas with local material/quarry muck,spreading in layers, levelling the top at site and consolidation by ramming,etc complete for the CBR value of sub grade)<br>
CIAL Road Restoration
OD71297/2024-2025:Cutting of Bituminous /RCC surface using specialised tools without damaging the bitumen/RCC surface in cluding cost of labour, conveyance,lead, lift,rent and allenergy charges as per specification and a directed by the engineer- in charge
OD71298/2024-2025:Supply and stacking of coarse sand to site as per direction of the engineer-in- change including cost of material , lift, lead, loading & unloading charges
OD71299/2024-2025:Filling available coarse sand in trench etc. in layaers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.50 m. Cost of sand paid separately.
OD71300/2024-2025:Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix pplant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of 3 specified thickness with motor grader on prepared surface and compacing with vibratory poer roller to achieve the desired density, complete as per specifications and directions of Engineer-in-charge
OD71301/2024-2025:Providing, laying, spreading and compacting graded sione aggregate to wet mix macadam as per clause 405 of MORTH specification including pre-mixing the material with water at OMC in mechanical mix plant carriage of mixed materia! by tipper to site, laying in uniform layers of maximum thickness 150mm with paver in sub-base/ base course on well prepared surface and compacting with vibratory roller to achieve desired density, etc. complete as per specification.
OD71302/2024-2025:Providing and applying prime coat using hot straight run bitumen of grade VG - 30, including heating the bitumen,spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications and as directed by the Engineer in charge.
OD71303/2024-2025:Providing & applying tack coat with bitumen grade VG-30 using pressure distributor at the rate of 0.20kg per sqm on the prepared bituminous surface cleaned with mechanical broom etc. complete and as per specification and directed by Engineer-in-charge.
OD71304/2024-2025:Providing and laying bituminous macadam with 100-120THP hot mix plant producing an average out put of 75THP using crushed aggregates of sprcified grading premixed with bitumionous binder VG-3.3% by weight of total mix transported to site, laid over apreviously prepared surface with hydrostatic paver finisher with sensor control to required grade, level and aligment and rolled with tandem rollers as specified to achieve the desired compaction complete as per MORTH specification and as directed by Engineer-in-charge,Grading II, 19mm nominal size.
OD71305/2024-2025:Providing and laying bituminous concrete with 100-120TPH hot mix plant producing an average output of 75TPH using crushed aggregates of specified grading premixed with bituminous binder VG-30 at 5.4% by weight of total mix,8 cement as filler, transported to site, laid over a previously prepared surface with hydrostatic paver finisher with sensor control to required grade, level and alignment and rolled with tandem rollers as specified to achieve the desired compaction Complete as per MoRTH specification and as directed by Engineer-in-charge.
Bidder Name
Koya and Company Construction Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid