Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted bidder. | |
| 2 | L2₹19.3 L+₹61,355.30 (3.29%)Rejected-Finance | L2 | Rejected-Finance Higher quoted bidder. | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in the requisite category of b(i) |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Jan 2023, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REPAIR MAINT OF FLOORING, HARD STANDING, FENCING, CLEANING AND REPAIR TO SEWAGE DISPOSAL, REPAIRS TO EXTERNAL WATER SUPPLY AND EXTERNAL ELECTRIFICATION AT MIL STN CHARMAGAD UNDER GE PITHORAGARH
2022_MES_570824_1
8503/PGH/E8
Open Tender
Civil Works
Item Rate
330 days
GE Pithoragarh
Class E, Category a(i) and b(i)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹50,000
Yes
20 Mar 2023
23 Dec 2022
6 Feb 2023
23 Dec 2022
30 Jan 2023
6 Jan 2023
Amount
DESCRIPTION OF ITEMS
Maintenance and complete servicing/overhauling of existing DG Set of capacity 4.8 KW/6 KVA including replacement of filters,di -assembling of operating mechanism / parts, well cleaning with chemicals, replacing unserviceable parts / assessories, oiling / greasing of complete moving parts, calibration and resetting of governer by the rep of reputed manufacturer, cleaning of injector nozzle, cleaning/descaling of radiator assembly with cleaning agent, removal of all deposited materials including oiling / greasing of exhaust fan & bearing etc. including re - assembling the DG set after replacing the unserviceable parts and components etc. and making DG Set in perfect operational in manual and electrical mode, complete all as directed. Note:- (i) Spare parts will be measured and paid seperately under respective items of Sch 'A'. (ii) Make of parts shall be same as per existing make (iii) The contractor and rep of Engineer-in-charge shall prepare jointly a list of unserviceable parts after opening the DG Set.
Supply only the following spare part of existing make & size, suitable for DG Set 4.8 KW/6 KVA complete in all respect & as directed. :- (a) Rubber hose pipes with fixing clamps
(b) Lubrication oil filter
(c) Fuel filters
(d) By Pass filters (as per sample)
(e) Fuel pipe duly covered with supper fine steel wire with coupling , nut and bolts.
(f) Fan belt (as per sample)
(g) Engine gasket.
(h) Lubrication Oil,
(J) Air filter
(k) Replacement of Hose: Air Cleaner.
(l)Replacement of Gasket: oil filter
(m) Replacement of Gasket: O -Ring
(n)Replacement of Ring: Seal
Dismantling of MH / LED/ T-5 light fittings of any capacity from existing poles / buildings of any height/type including re-fixing after repair/replacment of unserviceable parts such as LED drivers,LED modules T-5 tubes, chokes etc and making the fitting functional by replacing minor parts such as nuts,bolts PVC connector complete all as specified and directed. Notes:- (a) Parts shall be measured & paid separately as given here-in-after. (b) Contractor shall attend complain with-in 24 hrs in case non attending by the contractor the recovery shall be made @ Rs 50 per complain per day . (c) Contractor shall provide all tools and plants and minor spares such as Ladder minor nuts bolts, jumper wire, insulation taps etc required for doing the job related with electric supply including mobile phones for communication and will be fully responsible for safety and security of their man. ( d) Job cards will be provided by the contractor. (e) To make clear the shortened and current leakage of shortend electric street light line is also included in the quoted rate.
Supply and fixing in repair Integral LED street light driver, enclosed with glass cover frame suitable for existing make/models of LED street light/flood lights of capacity 25/30 W complete all as specified and directed.
Supply and fixing in repair Integral LED street light driver, enclosed with glass cover frame suitable for existing make models of LED street lights/flood lights having capacity 40/45/48/50 W complete all as specified and directed.
Supply and fixing in repair Integral LED street light driver, enclosed with glass cover frame suitable for existing make/models of LED street light/flood lights of capacity 60/65/70/72/80/90 W complete all as specified and directed.
Supply and fixing in repair Integral LED street light module with complete PCB and LED bulb suitable for 25/30 W LED street light for existing make and model complete all as specified and directed.
Supply and fixing in repair Integral LED street light module with complete PCB and LED bulb suitable for 40/45/48/50 W LED street light/flood lights for existing make and model complete all as specified and directed.
Supply and fixing in repair Integral LED street light module with complete PCB and LED bulb suitable for 60/65/70/72/80/90 W LED street light/flood lights for existing make and model complete all as specified and directed.
Supply only cable twin core PVC insulated and unsheathed solid aluminium conductor of size 2.50 Sqmm complete all as specified and directed.
Supply and fixing in repair Isolator 4pole 63 Amps,415 Volts includeing weather proof box all as specified and directed
Supply and fixing in repair Isolator 2 pole 40 Amps,220 Volts including weather prof box all as specified and directed.
Supply and fixing in repair powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens & IP 66 protection suitable for 48Watt.
Supply and fixing in repair powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 60 Watt.
Supply and fixing in repair powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 30 Watt.
Supply and fixing street light bracket made out of 25 mm dia GI pipe light grade of length upto 1.5 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Supply ,fixing ,commisioning and testing of Nature timer switch control street lights complete with MCB, power and panel duly complete with wiring Model : SWADEEP-02EC 12 KW 3P, three phase max load 12 KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERBAD or equivalent of other make complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor.
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular 6 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed.
Taking out old unserviceable Old LT cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Making horizontal bore hole under road of 50 mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
S & F in replacement GI pipe light grade 40 mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I - 1988 with aluminum conductor 1100 Volts grade of cross sectional area 10 Sqmm , 2 core of in ducts or on walls laid in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 4 core 16 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 3.5 core 25 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 3.5 core 35 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 3.5 core 50 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 3.5 core 70 Sqmm complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium copper conductor , 1100 volts grade of size 3.5 core 95 Sqmm complete all as specified and directed.
Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators.
Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators.
Restretching of ACSR conductors of any type / any size on essential LT Poles and fixing with 2 mm dia aluminium binding wire complete all as specified
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed by the Engineer-in-charge.
Cleaning and preparation of old painted surface of LT/street light pole complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making Red & white strips with synthetic enamelled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coats of white wash on PCC coping complete all as specified. Note : Pole serial no. will be as approved by GE/Engr-in-charge.
Material and labour for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces including broken of existing PCC all as specified & directed.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
Dismantling of LT PCC/steel tubular pole of any size and discription incl coping, foundation etc and shifting to E/M yard.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
Supply, fabricating and fixing, cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron , flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint as well as dismantling of existing all as directed
Supplying, drawing and fixing in replacement of contineous GI earth wire/gaurd/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on HT/LT poles incl taking down old rusted GI wire all as specified and directed
M&L for earthing in replacement complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected.
Supply and fixing in replacement of danger notice plate of 1.6mm thick, MS sheet, vitreous enamelled white, with letters, figuers and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3 mm, nuts-bolts, of approved size for LT 20 x 15 cm.
Supply and fixing in repair of PVC LT OH line spacer for 5 wires complete all as specified and directed.
Supply and fixing in repair of PVC LT OH line spacer for 4 wires complete all as specified and directed.
Supply and fixing in repair of PVC LT OH line spacer for 2 wires complete all as specified and directed.
M & L in repair for factory fabricated bus bar chamber outdoor type water vermin proof of size 600x400x250 mm duly provided with front openable door and PU(Polyurethene + Isocyanides) formed Gaskets with IP-66 protection rubber gasket housed with TPN aluminium bus bar on porcelain insulated with the bus bar size of 350x40x5 mm for phases and neutral incl making connections, cable entry/exit holes with front door locking arrangements and busbar panel shall be pedestal type and provided with four nos of angle iron supports duly embedded in foundation and complete bus bar chamber shall be CRCA type powder coated.
Cutting of floor/wall/road/footpath for removal of LT U/G cable of any size/description and making good the same as per existing specification after relaying the same or new cable and all as specified & directed.
S/F in repair MCCB 4 pole 100 Amps with breaking capacity 16 KA 415 volt & elect connection etc completeall as specrfied and directed.
S/F in repair MCCB 4 pole 160 Amps with breaking capacity 25 KA 415 volt & elect connection etc completeall as specrfied and directed.
S/F in repair MCCB 4 pole 250 Amps with breaking capacity 25 KA 415 volt & elect connection etc completeall as specrfied and directed.
S & F in replacement standard duty resin filled capacitor 440 V, 3 phase 5 KVAr. Note : Necessary addition /altration required to adjust Capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor.
All as per Item No.55 above but of 10 KVAr
All as per Item No.55 above but of 15 KVAr
S & F in replacement contactor 440 V, 3 phase 5/10/15 KVAr. Note : Necessary addition /altration required to adjust Capacitors in the panel shall be done by the contractor and no extra payment will be made to the contractor.
S & F in replacement LED type phase indication lamp of Red /blue/Green colour for phase indication in existing panels complete all as specified and directed.
All as per item No 60 Above but for checking of voltage.
M&L for preparing old painted surface of LT/APFC panel board by cleaning removing of the old paint by scracthing with wire bursh/sand paper etc and including denting/patching of brocken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting on inside/outside surface of panel,all as specified and directed. Note : repairing of old rusted rivets/nut bolts are deemed to be included in coated rates.
S & F in repair jumper wire cross sectional area 70 Sqmm single core stranded aluminium conductor PVC insulated on OH lines complete all as specified and directed.
S & F in repair jumper wire cross sectional area 95 Sqmm single core stranded Aluminium conductor PVC insulated on OH lines complete all as specified and directed.
Supply and fixing in repair of micro prismatic reftective sheet, min 2.5 cm wide, with adhesive base for dirtectly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed.
Supply and fixing in repair of glow sign board (box type) LED of required size 1200 X 900 mm made out of MS sheet of suitable size with flex sheet of suitable size with flex sheet fixed on front end quality marked with details of electric substation on front and rear with different colours including provision of LED power fittings & fixtures in equal distance to illuminate board including connections with 2.5 sqmm single core stranded copper conductor cable in conduit and wiring and fixing of MCB with weather proof box with 10 mm size letters as specified and directed by Engr in charge.
Supply and fixing in repair of test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8 mm dia, 25mm long, hex head screw.
Supply and fixing in repair of air termination, single pointed aluminum rod 12 mm dia and 300 mm long. Note: All accessories for fixing of termination is included in the quoted rates.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
S&F in replacement of TPN off load change over switch of capacity 32 Amp including dismantling of existing complete all as specified and directed
S&F in replacement of TPN off load change over switch of capacity 63 Amp including dismantling of existing complete all as specified and directed
S&F in replacement of TPN off load change over switch of capacity 100 Amp including dismantling of existing complete all as specified and directed
Supply and Fix in replacement of 15 mm dia bore Gun metal gate valve screwed both end with iron head wheel complete all as specified and directed.
All as per Item No 75 above but 20 mm dia bore
All as per Item No75above but 25 mm dia bore
All as per Item No 75 above but 40 mm dia bore
All as per Item No75 above but 50 mm dia bore
Disconnecting and taking up or down steel water tubing and connections for 15 mm dia bore size complete all as specified and directed.
All as per Item No 80 above but size 20 mm dia bore
All as per Item No 80 above but size 25 mm dia bore
All as per Item No 80 above but size 40/50 mm dia bore
Material and Labour for 15 mm dia bore GI tubing medium grade complete with all fittings laid in trenches/ walls all as specified and directed.
All as per Item No 84 above but size 20 mm dia bore
All as per Item No 84above but size 25 mm dia bore
All as per Item No 84above but size 40 mm dia bore
All as per Item No 84 above but size 50 mm dia bore
Dismentling of existing valve chambers and removing the demolished materials to a distance not exceeding 50 m and Material & Labour for reconstruction of the same (internal size 950x950x950 mm) with PCC 1:3:6 type C-1 using 20 mm graded stone aggregate solid blocks masonry set in CM 1:6 with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in foundation, PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring bed & copping and applying 15 mm thick cement plaster in cement mortar 1:4 mixed with water proofing compound as per manufacturers instruction on the inside of valve pit & valve pit cover made out of 3mm thick mild steel sheet with 40 x 40 x 5 mm angle iron frame and 40 x 5 mm mild steel hold fast embedded in PCC including two coats synthetic enamel paint blue over a coat of red oxide primer etc complete all as specified and directed.
All as per Item No 89 above but of size 650x650x650 mm
Supply and Fix in replacement of 80mm dia Sluice valve both end flanged class PN-1.6 non rising type complete with stainless Steel spindles check nut CI wheel including all fixing arrangements complete all as specified and as directed.
Supply and Fix in replacement of 100 mm dia Sluice valve both end flanged class PN-1.6 non rising type complete with stainless Steel spindles check nut CI wheel including all fixing arrangements complete all as specified and as directed.
Taking out brass /Steel spindles of sluice valve for remetaling /regrinding complete as required and refixing the same in position of size 80 mm dia complete all as specified and as directed.
All as per Item No 93 above but 100 mm dia
Material and Labour for opening up the motor 7.5/5/3 HP carefully and removing burnt windings from stator and rewinding with suitable gauge of supper enamelled copper insulated wire and superior insulating material including varnishing, heating, greasing replacement of worn out bearing, reassembling the same,including testing on full load up to entire satisfaction, complete all as directed ..
S&F in replacement rubber coupling suitable for 7.5/5/3 HP Pump complete all as directed.
S&F motor bearing of existing size complete suitable for 7.5/5/3 HP
S&F in replacement of stainless steel shaft with check nut etc complete suitable for 7.5/5/3 HP centrifugal pump complete all as specified and directed.
M & L for petty repair to water supply network of upto 50mm bore pipe line for stopping leaking by providing new GI union, socket, Tee , elbow, bends, nut bolts, washers or welding etc as required at site and testing on completion including earth work complete all as specified and directed.
Material and Labour in replacement of existing water level indicator of overhead tanks & underground sumps by replacing the defective parts such as MS pully with bearing, steelwire rope of required length, float ball duly painted and graduation board (welding work or changing of sheet as reqd on site) including painting and numbering etc complete all as specified and directed.
Material and Labour for cleaning (taking out mud, grass & bushes etc) of ponds near main source complete all as directed .
Material and Labour for cleaning of 2000 Gallons capacity RCC ground water tank/ clarifying cum sedimentation tank, flow water tank pumping out all water, taking out dirty water stone pieces and sludge etc by usnig buckets / motor, cleaning and removing all dirt and plant completely from wall and floor of the tank and from mouths of inlet and outlet pipes etc and by rubbing with wire brushes and removing all waste to distance not exc 50 mtr and depositing where directed cleaning the tank inner surface with suitable cleaning agent and fresh water and removing dirty water out of the tank complete with in 12 Hrs and writing date of cleaning on external surface of wall with synthetic enamel paint after removing old date complete all as specified and directed.
All as per item No. 102 above but 7500 gallon capacity
M & L for repairs to existing leaking joints (flanged/socketed /collar) for 80/100mm bore GI pipe line including supply and replacement of flanged/socket/union/reducer etc with and including all necessary GI nut bolts, fibre/rubber gasket sheet and welding work and to make threading wherever required, to make the joints leak proof including necessary cutting threading etc,and testing on completion including earth work complete all as specified and directed.
Demolition of brickwork or stone/boulder masonary, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles and block walling.
Taking down cement plaster on brick or stone walls, etc. Including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M & L Precast cement concrete block masonry with solid bloks exc 10 cm width and setting in cement mortar 1:6 type C1 1:3:6 (20 mm graded agg) complete all as specified and directed.
M & L 15 mm thick cement plaster with water proofing compound on fair faces of brick work or concrete surface on wall in CM 1:4 finished fair and even complete all as specified and directed. (Water proofing compound measured separately)
M & L 15 mm thick cement plaster with other than fair faces of brick work or concrete surface on wall in CM 1:6(outside of man hole upto 150 mm below GL) finished fair and even complete all as specified and directed.
Supply only Integral water proofing compound, complete all as specified and directed.
Demolition of cement concrete re-inforced of any description not otherwise specially provided for.
M & L for Precast RCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in cover slab, shelves etc set in CM 1:6 complete all as specified and directed.
M & L for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 of type C-2 using 40mm graded stone agrregate as in sub base of floors complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 of type C-2 using 40mm graded stone agrregate as in plinth protection finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as Cement concrete in floor complete all as specified and as directed.
S&F Glass dividing strips, 3 mm thick and width of strip 38 mm
Taking down existing cover of septic tank any type and cleaning of same including dewatering and digging out sludge , mud state and removing the sludge to a distance exc 250m and n. exc 500m and disposed off as directed including cleaning of inlet & outlet pipes and tank with clean water and placing the cover in position, complete all as specified and directed
Taking down existing cover of Soack well size of any size and cleaning of same including mud state and removing the sludge to a distance exc 250m and n. exc 500m and disposed off as directed including cleaning of inlet and tank with clean water and placing the cover in position, complete all as specified and directed
Cleaning of sewage manhole of any size and sewage line upto 150mm dia and disposal of waste material to a ditance n.exc 50m by any means complete all as directed
Cleaning of blockage of EWC/ IWC trap exc 100 mm but n.exc 150mm dia and disposal of waste material to a ditance n.exc 50m from outer face of bldg complete all as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding, kota stone/granite slab including screed bed and removing rubbish off the premises complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.06 Sqm but n exc 0.11 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floor over and including 15mm thick screed bed in CM 1:6 mixed etc complete all as specified and directed.
M & L for galzed ceramic coloured tiles 300X200X 7 mm thick on walls etc set & jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces over &.incl 10mm thick rendering in cement mortar 1:4 for laying wall tiles etc complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
S & F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M/S ANAND SINGH DHAMI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .