| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC H NO 104 WARD 2 PURANI MANDI HP 175001 | MANDI | HIMACHAL PRADESH | 175001 | ₹16.8 L | L1 | Accepted-AOC Quoted rates are lowest |
| 2 | L2₹18.6 L+₹1.8 L (10.8%)Rejected-Finance GROUND FLOOR DOLFIN CONSTRUCTION KHEWAT NO 263 KHATAUNI NO 255 VPO TALYAHAR TEHSIL SADAR DISTT MANDI H P 175001 | MANDI | MANDI | HIMACHAL PRADESH | 175001 | ₹18.6 L+₹1.8 L (10.8%) | L2 | Rejected-Finance Quoted rates are higher |
| 3 | L3₹19.0 L+₹2.2 L (13.3%)Rejected-Finance | ₹19.0 L+₹2.2 L (13.3%) | L3 | Rejected-Finance Quoted rates are higher |
| 4 | L4₹19.1 L+₹2.4 L (14.1%)Rejected-Finance VILL JANDROHALI PO JAI DEVI TEHSIL SUNDER NAGAR DISTT MANDI HP175031 | MANDI | HIMACHAL PRADESH | 175031 | ₹19.1 L+₹2.4 L (14.1%) | L4 | Rejected-Finance Quoted rates are higher |
Tender Value
₹20.7 L
EMD Value
₹41,370
Closing Date
6 Nov 2024, 6:00 pmClosed
Superintending Engineer IIT Mandi Kamand
o/o Superintending Engineer South campus IIT Mandi Kamand Distt. Mandi HP-175075
Water proofing of open terraces including providing and fixing of floor tiles and false ceiling in rooms of campus school of IIT Mandi.
2024_IITMD_831100_1
IIT Mandi (CW)/SE-1595/2024-25/1872-74 dated 15-10-2024
Open Tender
Civil Works
Item Rate
60 days
North Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹41,370
1 Feb 2025
16 Oct 2024
8 Nov 2024
16 Oct 2024
6 Nov 2024
16 Oct 2024
16 Oct 2024 - 5 Nov 2024
Amount
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement. a) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing sheet covering over expansion joints with iron screws as per design. a) Aluminium fluted strips 3.15 mm thick. i) 200 mm wide as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: a) Cement mortar 1:4 (1 cement : 4 coarse sand) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
12 mm cement plaster of mix : a) 1:4 (1 cement: 4 fine sand) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineerin- charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 a) Upto 20 mm depth and 20 mm width as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. a) For thickness of tiles above 25 mm and up to 40 mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. a) Glazed Vitrified tiles Matt/ chemically Antiskid finish of size. i) Size of Tile 600 x 600 mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. a) 150 mm diameter as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Coupler i) 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Single tee with door i) 150x150x150 mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Single tee without door i) 150x150x150 mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) Bend 87.5° i) 150 mm bend as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : a) 8 mm thick cement board as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : a) Flashings/ Aprons.( Upto 600 mm) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : a) Gutter (600 mm over all girth) as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. a) GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. a) Two coats as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from a) grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing and applying Polysulphide sealent for the filling/treatment of expansion joints/floor joints/other joints etc upto 5 to 10mm wide. complete as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Providing, mixing and laying of waterproofing treatment by base preparation of cleaning, brushing and removal of any loose/flacky materials, in case of pot holes/cracks, the same shall be repaired with Polymer modified cement mortar using Latex. Grinding of tiles/Kota is a necessary to make the surface more abrasive and good for adhesion. Providing and applying smartcare Ultron liquidapplied hybrid Polyurethane polyuurea based, two component, llow VOC, elastomeric , seamless, waterproof coating bearing the following properties: a) Mixing ratio by weight 11 Kg :9 Kg [Base:Hardener] Elongation at break at 1.2 mm in 500 ± 50% ASTM D 2370 Tensile Strength at 1.2 mm Min 9 MPa ASTM D 2370 Puncture resistance at 1.2 mm250±20 N ASTM E 154 Hardness (Shore D scale) Min 35 units ASTM D 2240 Pull Of Adhesion (Concrete surfacefailure) Min 1.5 MPa ASTM D 4541 Pot Life at 25 Deg C and 50% Relative Humidity 30 minutes Solid content>85% ASTM D 1644 Water impermeability on coated concrete at10 bar for 72 hours No Leakage BS EN 12390-8 (Resistance to Hydrostatichead > 100m) Application Temperature 10 - 40 deg C Overcoating interval time 12-16 Hrs Light Pedestrian traffic time 24 Hrs, however final curing time conditions 30 deg C, 55% RH 14 days Crack bridging Min 4 mm ASNZ 4548.(iii) Applying a 5 to 10 mm coat of micro-concrete on the Ultron surface so that it can be prevented from high load damage including carriage of material as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Kartike Guleria (BID ID -3116032)
M/S OASIS ENTERPRISES (BID ID -3115882)
ACES DESIGN AND INFRATECH SERVICES (BID ID -3115750)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .