Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹15.9 L+₹61,332.60 (4.01%)Rejected-AOC | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹17.1 L+₹1.8 L (11.8%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹18.1 L+₹2.8 L (18.2%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹16.3 L
EMD Value
₹32,640
Closing Date
16 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RAMGARH
GE RAMGARH CANTT
PROVN OF MEDICAL STORE OFFICE AT MH RAMGARH
2022_MES_564799_2
8300/3142/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE RAMGARH
₹32,640
Yes
16 Feb 2023
30 Dec 2022
18 Jan 2023
30 Dec 2022
16 Jan 2023
2 Jan 2023
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Add to (or deduct from) above item No. 1 for every 3cm or part there of above or below 15 cm average depth complete all as specified and directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M& L for use & waste of form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in columns,pillars,piers,popst and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M& L for use and waste of form work to sides of columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, , etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in chajja etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M& L for use and waste of form work to sides of soffit of chajja,chullah hoods,troughs & similar items etc including for rough finished surface of concrete complete all as specified and directed.
M& L for use and waste of form work to sides of soffit of suspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed.
M& L for use and waste of form work to sides and soffit of lintel Beam,floor/roof Beams, etc for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed.
M&L for Brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for half brick thick Brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L for with moorum/ red bajri filling under the floor not exceeding 100 mm thick spreaded, levelled and rammed including watering complete all as specified & directed .
M&L for pre construction anti termite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & directed .
M&L for pre construction anti termite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the sub structure in contact with backfill to be measured) complete all as specified & directed .
M&L for pre construction anti termite treatment for treating the the top surface of filled at the rate of 5 litres of emulsion per square metre of surface complete all as specified & directed .
M&L for pre construction anti termite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & directed .
S & F brass 4 screw plate drawer pulls, plate with fixed dished pull; 80 mm to 100mm long complete all as spcefied and directed
S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engr-In-Charge .
S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing including 3 Nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed.
S&F 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed.
S & F 100mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed .
S&F 150mm extruded aluminium alloy handles, cast type, anodised complete all as specified & directed.
S&F 150mm aluminium alloy handles, cast type, anodised complete all as specified & directed.
S&F of aluminium mortice lock, vertical type, size 75 mm four levers (ISI marked) for aluminium doors complete all as specified and directed.
S&F 65 mm ,four lever brass locks, drawer,grade-I of size 65 mm complete all as specified and directed.
S&F floor door stopper of aluminium alloy body& tounge,150 mm ,anodised with hard drawn steel spring fixed in floor complete all as specified and directed.
S&F brass 4 screw drawer plate with fixed dished pull; 80 mm to 100mm long complete all as specified and directed.
S&F floor double action spring hinges,brass with phosphor bronze wire spring, bright polished of size 100 mm complete all as specified and directed.
M & L for 18/19 mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work complete all as specified and directed.
S&F 40mm dia, brass ,cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed.
S&F brass handles 150mm size cast type ,polished bright complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M & L joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed.
M & L glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm/450 mm x 300 mm x7 mm thick ,as in dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles including 10 mm thick rendering in cement plaster in CM (1:3), complete all as specified and directed.
M&L for Vetrified dark shed coloured ceramic floor tiles 10 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:6) etc complete all as specified & directed.
M&L for Vetrified dark shed ceramic tiles 10 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
M&L for rendering 10 mm thick on brick masonry/concrete surface etc in CM (1:6) surface finished even & smooth using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair face brick masonry/concrete surface etc in CM (1:4) surface finished even & smooth using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:4 on concrete surfaces as in ceiling finished even and fair complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall and applying two coat acrylic exterior emulsion paint of required shade over and including priming coat of exterior primer and a layer of putty (not less than 1.5 mm thick ) complete all as specified and directed.
S &F powder coated aluminium work for doors, windows, ventilators shutters(fixed/sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle, C.P. brass/ stainless steel screws, all complete all as specified and directed.
S&F powder coated aluminiumsliding door shutters (minimum thickness of powder coating 50 micron) , aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long (1No.),100mm long hinges type B-21 (2Nos), suitable handle(02 Nos.) in each door top rail guide rail etc. complete all as specified and directed.
&F powder coated aluminium window and ventilator shutters (minimum thickness of powder coating 50 micron) ,fixed type without sash bar aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings complete all as specified and directed.
S&F for anodised aluminium grills for windows and ventilator aluminium sections (weight not less than 2.25 kg/Sqm) size 4mmx4mm, 8mm thick and aperture not exeeding 80 mm X 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint complete all as specified and as directed.
S&F 5.5 mm thick sheet glass not exceeding 0.5 Sqm in each pane of superior quality fixed to aluminium frame work with rubber neoprene beading including solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified & directed.
S&F 4 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls /laid in trenches and ceiling or laid in floors including cutting chasees for brick walls and making good the surfacein cement mortar 1:3 complete all as specified & directed.
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and directed.
S&F 20 mm bore brass ball/ float valves high pressure with polythene float & fly nut complete all as specified and directed.
S&F bib taps long body, cast copper alloy with capstan head or butter fly handle, chromium plated fancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified & directed.
S&F fancy type angle stop valve fancy type chromium plated with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15 mm bore complete all as specified & directed.
S&F pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered 'Hot' or 'Cold' with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed.
S&F for PVC connection 15 mm dia size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F 75 mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or in wall complete all as specified and directed.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement with chromium plated grating with or without hole complete all as specified and directed.
S & F PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set all as specified and directed.
S & F vitreous China wash basin, any colour, flat back size 550 mm X 400mm including 32mm brass chromium plated waste coupling ,PVC 32 mm bore waste pipe, chromium plated Grating including bracket complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) in kerbs or mud stops, rounded or chamfered on edges water troughs and the like including necessary form work complete all as specified and directed.
M & L for 15 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing non accessible/non approachable RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying approved bituminous based primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & hot blown grade bitumin 85/25 @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /sqm over APP Membrane. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
Supply only liquid water proofing compound complete all as specified and directed.
M&L for 60mm thick factory made machine pressed pre-cast concrete coloured interlocking paver block of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including cleaned dry sand cushion bed 50mm thick over & including 100 mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as sub-base, surface finished even and rough over and including 75mm thick Hardcore of broken boulder of gauge n exc. 63mm, deposited, spread and levelled, watered and rammed to a true surface, etc complete all as specified and directed.
M & L for 100 mm thick Concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate ) complete all as specified & directed.
M & L for 150 mm bore (internal dia )reinforced concrete drain pipe ,class NP-3, laid and jointed in trenches complete all as specified & directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundations, bed of manhole ,filling & mass concrete etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in surface channels /benching of manhole ,drain ,laid to shape and slope and surface finished even & smooth using extra cement complete all as specified and directed
S& F 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
M&L for drilling in existing water pipe, taking new tapping from existing pipe,proper welding to the pipe surface complete all as specified and directed
S& F towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 90 gms) complete all as specified and directed
S&F vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. Note : Plastic seat cover shall be measured separately as Supply only as considered under respective items.
Supply only plastic water closet seat cover,black,closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S & F health faucets ,ABS body with 1.0 mtr long easy flex tube in chrome finish and wall hook complete all as specified and directed.
S & F chromium plated toilet paper holder fixed to walls complete all as specified and directed.
M&L for point wiring for one light/fan/exhaust fan point /exhaust fan/ bell /buzzer point controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steel sheet terminal box made out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including PVC board with bakelite sheet 2.8 mm thick laminated cover make sheet for housing/fixing switches etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
All as per item No. 88 here-in-before but 5 Amp socket outlet on same board.
All as per item No. 88 here-in-before but for 5 Amp switch socket on independent board.
M&L for point wiring with FRLSH PVC insulated PVC sheathed electric cable confirming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 2.50 Sq.mm nominal cross sectional area for phase & neutral & including non metallic rigid PVC conduit ISI marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 Sq.mm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steel anodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with Bakelite hylem sheet 2.80 mm thick complete for one switch socket outlet combination ,15 Amps & 5 amp socket point on independent board controlled by one ,one way switch complete all as specified and directed.
S & F switch piano flush button single pole one way 5 Amp, complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin, 5Amp, flush type, universal, complete all as specified.
S & F Switch socket combination 2 in 1, 3 pin, 5Amp and 15 Amp flush type, universal, complete all as specified.
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp, flush type, universal, complete all as specified.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
S & F bell push type single pole one way 5 amps, complete all as specified.
S & F bell electric ding dong AC 230 volts single pole complete all as specified.
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S&F five stepped type electronic fan regulator flush type controlled 230 V, , 120 watt etc complete all as specified and directed.
S&F for ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air dilivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including connecting up with three core flexible copper conductor cable suitable size from ceiling rose to fan terminal with necessary accessories complete all as specified and directed.
S & F LED light fitting 1 x 20watt , 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engr-in-Charge. Make: Havells/Bajaj/Crompton Greaves/Phillips.
S & F LED bulb of capacity 10 watt , lumen out put (950)lm ,length 102 mm dia 56 mm , base cap B22 (ISI mark) complete all as specified and as directed by Engr-in-Charge. Make: Havells/Bajaj/Crompton Greaves/Phillips.
S & F plastic body Exhaust fan of 250 mm sweep with louvers shutter ,single phase ,230 V,50 Hz,1200 RPM AC ,copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed.
S & F sheet metal enclosures for DBs when MCBs to used single pole and neutral (SPN) double door 240 volts, 8 way with IP-43 IK-09 protection including 200 Amp bus bar and neutral link (ISI marked), complete all as specified and as directed.
S & F amp rating 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: IndoAsian or its equivalent make in Havells/Standard/L&T.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: IndoAsian or its equivalent make in Havells/Standard/L&T.
M & L Sub main wiring two single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. Note : - 2 runs of 6.0 Sqmm cable and 1 run of earth wire 6.0 sqmm shall be measured as one unit length.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 2.0 core complete all as specified and directed.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV, type- 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
S & F 25 mm bore GI tube, light grade for cable protection with all necessary fitting, complete with all fittings laid as in floor etc., complete all as specified and as directed.
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test report should be submitted by the contractor duly tested in presence of Engineer-in-Charge
M&L for Boring of hole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine with & including provision of 50 mm bore light grade GI pipe for protection of cable complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/taxi track / apron /floors etc.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required in 150mm internal dia pipe complete all as specified and as directed.
upadhyay engineers and consultant
Paras Nath Singh
om suppler
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .