| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹6.6 L+₹14,500 (2.26%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.9 L+₹49,800 (7.76%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF Kumbhirgram
AGE I AF Kumbhirgram Military Engineer Services PO Kumbhirgram Assam Pin 788109 Tele 03841282376
REPAIR REPLACEMENT MAINT OF COOLING APPLIANCES AT AF STN KUMBHIRGRAM
2023_MES_576905_1
8455/2022-23/E8
Open Tender
Civil Works
Item Rate
180 days
AF STATION KUMBHIRGRAM
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE I AF Kumbhirgram
₹12,000
Yes
2 Mar 2023
24 Jan 2023
16 Feb 2023
24 Jan 2023
14 Feb 2023
31 Jan 2023
Amount
Dismantling of AC ( Window / Split type), Refrigerator, water coolers of any capacity & 'make', opening up for servicing, inspection / examination for serviceability of compressor, fan, motor, relay, overload protectors, capacitors, cleaning the evaporator and condenser with compressed air/ water as required, lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, Refrigerator complete all as directed. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge
Supply and replacement of hermetically sealed Rotary / reciprocating type compressor of 1.5 TR capacity for window type/split type AC of existing make and model with new compressors and assembling testing the same with replacement of necessary drier and capillary tube complete including taking down all as directed by Engineer-in-Charge .
All as per item No-2 here-in before but 2.0 TR Window/Split type Room Air Conditioner compressor .
Repair to worn out body of window type AC/ Out door unit of Split type AC of any make & capacity by replacing worn out portion by providing new CRCA flat sheet / MS angle or strip of appropriate gauge as per existing and fabricated to the shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and apply two coats of synthetic paint over one coat of red oxide primer complete including taking down all as specified and directed.
Taking out blower motor of Window type AC of 1.5/2.0 TR capacity from its existing base and dismantling the same and rewinding the burnt out winding with super enameled copper conductor with existing gauge and size of conductor and varnishing all insulating materials including making necessary heat treatment complete all as directed by Engineer-in-charge.
All as per item No- 5 here-in before but of condensing fan motor of split type AC of 1.5/2.0 TR capacity.
Supply and replacement of unserviceable blower motor of Windo type AC/condensing motor of Split type AC with new motor suitable for WTAC/STAC of 1.5 TR capacity complete including taking down .
Supply and replacement of unserviceable blower motor of indoor unit of split AC with new blower motor of split type AC complete including taking.
Repair to voltage stabilizer of any capacity up to 5 KVA and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as specified and directed by Engineer-in-Charge. Note. Replacement of spare parts shall be measured and paid separately under respective items as supply only.
Supply only transformer of any capacity up to 5 KVA .
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers.
Supply only transformer relay for various capacity of stabilizers.
Supply only circuit board for various capacity of stabilizer .
Supply only 3 way connector for voltage stabilizer.
Material and labour for dismantling of Window type AC of 1.5 / 2.0 TR capacity and painting externally with one coat of synthetic enamel paint of existing shade of approved make after cleaning the surfaces and refixing, testing complete all as directed by Engineer-in-Charge.
Supply and fix in replacement of rusted and damaged bracket with new one for holding of window type AC as a platform made up of MS angle of size 50 X 50 X6 mm and MS plate of size 50 X 6 mm and grouted on the wall all as directed and specified including painting with two coat of synthetic enameled paint over a coat of red oxide primer.
Supply and charging of Refrigerant gas for Window type/ Split type AC /Refrigerator / Deep freezer of various capacity after leak test. Make :- Mafron/Floron.
Supply only capacitor 230/440 VAC, 50 Hz, 2.5 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 4 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 6 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 8 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 10 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 45 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply only capacitor 230/440 VAC, 50 Hz, 50 MFD,+ 5% capacity suitable for all split / wiondow type Air conditioners all specified and directed.
Supply and replacement of printed circuit board (PCB) with display board,sensor and remote control for Window type AC / indoor units of Split type AC of 1.5 TR capacity all as per existing type and make including taking down. (Make of existing AC : LG ,Voltas , videocon , Sidwal).
Supply and replacement of printed circuit board (PCB) of indoor or outdoor unit for Split inverter type AC of 1.5 / 02 TR capacity with display board, sensor and remote control including taking down all as per existing type.(Make of existing AC : voltas,LLoyd)
Repair of printed circuit board (PCB) of WTAC/Split type AC of 1.5/02 TR capacity with display board, sensor and remote control all as per directed.
Repair of Fin and Tubes type air cooled condenser Unit of Window / Split AC of capacity 1.5/2.0 TR all as per directed.
Supply and fix in replacement of fan blade assembly made of aluminium alloy complete for out door unit of split type AC all as per directed
Supply and fix in replacement of PVC fan blade suitable for water cooler of any capacity and size all as per directed
Supply and fix in replacement of PVC fan blade suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
Supply and fix in replacement of PVC blower suitable for any make of window type air conditioners of cap 1 TR to 2 TR as required and directed.
Supply and fix in replacement of Thermostat of 20 Amps capacity for 1.5/2.0 TR WTAC compressor including knob for thermostat.
Supply and replacement of metal clad plug top 3 pin all as specified and directed.
Supply and replacement of 3 Core 2.5 Sqmm multistranded copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer.
Supply only Nitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners along with insulating tape complete all as directed.
All as per item No 37 here in before but of dia 1/4" suitable for discharge/liquid line of Split type AC.
Supply and fix in replacement of PVC flexible Drain pipe of dia, suitable for Split type AC including hose clamp complete all as directed by Engr-in charge.
Supply and fix in repair single pole and neutral sheet metal enclosure with a two pin earth plug and socket complete with one single pole MCB of 20 Amp complete all as specified and directed.
Material and labour for sub main wiring with 2 run of single core 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of required size alongwith accessories on roof/walls/ ceiling etc including one run of 2.5 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 2.5 Sqmm single core cable, one run of 2.5 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length.
Shifting of 02 Nos of 02 Ton ACs (01 Split AC and 01 No of windo AC) i.e dismentling from one location and fixing at new hydraulic lab complete all specifIed and directed. Note : 1. Cost and provision of making holes for necessary connections through the existing walls and Plumbing and masonry work deemed to be included in unit quoted rates. 2. PVC pipe for draining out condensated water, refrigerant, copper tube with insulated material for complete Job, and factory made MS bracket will be measured and paid saperately
Supply and fix of copper pipe of size 1/2" dia complete all as directed.
Supply and fix of copper pipe of size 1/4" dia complete all as directed.
Supply and fix DBOXx MCB Combo plug and socket all in one device that provide protection to electric shock and overload and short circuit current of 20 A complete all as specified and directed . Make : Havells/Legrand/L &T.
M/S P K ROY AND SONS
M/S ANITA ROY and SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .