| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹1.0 L (0.93%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.1 Cr+₹1.0 L (0.93%) | L2 | Rejected-Finance High Bid |
| 3 | L3₹1.2 Cr+₹8.5 L (7.79%)Rejected-Finance | ₹1.2 Cr+₹8.5 L (7.79%) | L3 | Rejected-Finance High Bid |
| 4 | Rejected-Technical VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | - | - | Rejected-Technical Two Class below |
Tender Value
₹1.3 Cr
EMD Value
₹12.0 L
Closing Date
3 Dec 2024, 6:00 pmClosed
CWE Bareilly
HQ CWE Bareilly
CWE BLY/GE(W)/54 of 24-25 SPECIAL REPAIR REPLACEMENT OF EM ITEMS AGAINST BER AND PROVN OF ELECTRIC SUPPLY TO COMBAT WEAPON TRG SIMULATOR (CWTS) AT JRC UNDER GE (W) BAREILLY
2024_MES_679830_1
8100/B/831/E8
Open Tender
Civil Works
Item Rate
270 days
GE (W) Bareilly
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (West) Barielly
₹12.0 L
Yes
30 Jan 2025
16 Oct 2024
10 Dec 2024
16 Oct 2024
3 Dec 2024
11 Nov 2024
Amount
S&F in replacement Cable jointing kit for 11 KV (Earthed) grade cable for outdoor heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm complete all as specified and directed.
S&F in replacement Current transformer (CT) of 33 KV Single Phase, outdoor type, CT ratio 200/1 Amps and 100/1 (dual core one for metering and other for protection) having 16 VA burden and class 5P-10 protectioncomplete all as specified and as directed.
Supply, installation, testing and commissioning in replacement of gang operated air break isolators switch, outdoor type, 18 insulator, double stack, triple pole, rotating type double break per pole, suitable for horizontal mounting consisting of hot dip galvanized channel iron base having 02 Nos, 33 KV post type insulators per stack and 3 such stacks per pole copper or copper alloy high pressure heavily tinned contacts, plated MS arcing horns capable of breaking mangnetising current complete with phase coupling bar 25 mm GI pipe as down rod, lever coupling and operating handle with locking arrangement at for both 'ON' and 'OFF' positions coupling connections etc suitable for 33000 volts, 3 phase, 50 Hz AC supply system having 400 Amp complete all as specified and directed.
Supply, installation, commissioning and testing complete with all accessories of transformer of 33 KV capacity 5 MVA step down, outdoor type, floor mounted, double copper wound, 3 Phase, 50 Hz, AC, Oil immersed, ONAN/ONAF confirming to IS-2026 and IEC 62770 including cooling fans, external cooling tubes/radiator cores type having voltage ratio 33000/11000 volts (corresponding to principal tapping) winding delta connecting on Primary side and star connected on secondary side in accordance with vector symbol Dyn11 (vector Group) with neutral brought out on secondary side and looping on HV side for contact output so as to alter/vary secondary voltage by (+) 5 to (-) 15% in 8 steps of 2.5% each to be changed by means of (OLTC) Off Load Tap Changer. Transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability PRIME GRADE, CRGO with m4 grade or Better, Perfectly insulated and clamped to minimize noise and vibrations, core shall be purchased directly from manufacturer of core or from their accredited marketing network and not through any agent. Before placing order for procurement of transformer, the contractor shall submit the credentials in respect of the manufacturer of core and transformer shall be procured only after approval from GE in respect of name of manufacturer of transformer as well as manufacturer of core. The limit of temperature rise after continuous full load runs as specified in IS/IEC 60076 shall be suitably adjusted to suit the ambient temperature of maximum 50 degree Celsius prevailing at site all as specified and directed including having following characteristics :- The transformer shall confirm to the latest edition of applicable standard as follows :- (i) IS-2026, for tests and tolerance of guaranteed Particulars. (ii) IS-3639 for Fitting and accessories. (iii) IS-2099 for Bushing >1000V. (iv) IS-7421 for Bushing <1000 V (v) IS-1271 for Electrical insulation classified by Thermal stability. (a) Winding (i) Primary Side Winding - Layer/disc winding (ii) Secondary Side Winding - Helical/Disc winding (b) Insulation Level (i) Primary Side - 170 (ii) Secondary Side - 70 (c) Insulation level (Power frequency with Stand KVrms) (i) Primary Side - 70 (ii) Secondary Side - 28”
(d) Tapping Range - (+)5 % to (-) 15% @ 2.5% of 8 steps (e) Tape Changer Type - Off load Tap Changer + AVR. (f) Temperature Rise (Oil/Winding) - 50/55 Degree Centigrade (g) Hot spot temperature over a meximum yearly weight average ambient temp of 32 Degree Centigrade - 98 Degree Centigrade (h) Termination Primary/Secondary - Cable Box (j) Short Circuit thermal withstand time-02 seconds (k) % impedance at 75°C Current and frequency (Subject to IS Tolrance) at 10 MVA base % 8.35 (l) No load loss at rated voltage and frequency (subject to IS Tolerance) (KW) - 10 (m) Load loss at rated current and 75°C (KW) (subject to IS Tolerance ) at 10 MVA base - 70 (n) % load at which Max Efficency occurs % - 33.81 (o) Regulation at full load 0.8 PF%.- 5.75 p) Regulation at full load upf % - 1.05 The transformer should have following fitting and accessories :- (a) Cable Boxes on 11 KV secondary side for single core XLPE cable 3 Core 300 Sqmm (b) Outdoor 33 KV bushing insulator for connection through open conductor with sleeves. (c) Oil conservator with filling hole and cape drain valve and oil level guage. (d) Dehydrating breather with connecting pipe first fill of dehydrating agent and oil seal. (e) Explosion relief vent mounted on tank with double diaphragm and equilliser pipe connection to conservator air space (Pressure release device). (f) Air relief plug. (g) Shut off valve between the conservator and buchholz relay. (h) Drain valve with threaded adopter. (j) Filter valve with threaded adopter (Top and bottom)., (k) Wheels (l) Rating plate and terminals marking plate. (m) Extra bushing for neutral out side the Secondary Side (n) Hand hole sufficient size to assess the interior of the tank. (o) First filling of the transformer oil.. (p) Cover Lifting eyes. (q) Double float Buchholz relay with trip and alarm contacts. (r) 150mm dial type thermometer for winding temperature indicator having range 0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting device with alarm / trip contact and additional contact for switching on the cooling fan. (s) Dial type thermometer for oil temperature indicator with 02 sets of contacts for alarm and trip having range 0-12 centigrade vapor pressure type with maximum reading pointer/Max temperature indicator and resetting device with alarm/trip contact . (t) Shut off valve between cooling tubes and tank. (u) Pressure Release Valve (PRV) with one set of trip contact. (v) Magnetic Oil gauage (MOLG) with one set of trip contact. (w) Earthing terminal for connecting earthing lead
NOTE:- (i) The oil temperature and winding temperature guages shall be housed in a marshaling box made up of MS sheet as per manufacturer recommendations with hinged door and having glass front side of the box and provision for entry of cables and compression glands. (ii) Pre dispatch inspection of Transformer shall be carried out by representative of accepting officer at manufacturer premises within overall cost quoted by the contractor. Nothing extra shall be payable on this account at later stage. ' (iii) Completion has been given to contractor after pre-commisionig test carried out by SEI and all the euipment/instrument shall be arranged by the Contractor for testing. The cost of the same shall also be included in the item rate. (iv) Following documents to be submitted for core during the stage inspection: (a) Invoice of supplier (b) Factory test certificates (c) Packing list
M&L for Disconnecting of HT connections of existing transformer with earthings carefully and shifting the same from platform/sub station to AGE E/M Store yard including existing foundation will be repair and painted with white wash as per site requirement complete all as specified and directed.
M&L for lightining arrester expulsion type to be fixed on existing structure complete with all fitting, transmission class, discharge capacity 65 kilo amps suitable for 33000 volts complete as specified and directed
M&L for in replacement galvanized earthing complete with galvanised steel earth plate electrode of size 600x600x6.0mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using glavanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers made of MS and protected by light grade 40mm dia and 20mm dia bore for watering and incl funnel, wire mesh RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (incl excavation and earth work, disposal of surplus soil to a distance not exc 50 mtr) as shown on Plate No 3 of SSR Part-I 2010 including testing after completion complete all as specified and directed.
Supply and fixing Galvanised iron strip 32 x 6mm for connection of earthing with Transformer directly burried in ground complete all as specified and directed.
Taking down serviceable HT cable of size 300 Sqmm, 3 core (from cable duct/underground trench) and relaying after replacement of transformer complete all as directed. (Note :- Necessary earth work shall be measured and paid separately)
Supply and laying in replacement un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed.
M&L for in replacement Galvanised Steel Tubing Pipe 100 mm bore (dia), light grade with Bends, laid in Trenches or under Roads/ Flooring/ Culverts etc., complete all as specified and as directed.
M&L for maintenance of 33 KV indoor control and relay panel of 33 KV by checking wiring from outdoor VCB to indoor control panel, tightening of loose connections, U/S indicator with holder, thimble, replacement of unserviceable wiring including testing calibration and checking of tripping system of 33 KV control panel through all protective relays installed on each C&R panel including testing and adjust/ repair the alarm circuit as per time current characteristices by primary injuction test at 60%, 75%, 100% plug including well cleaning and decarbonizing of relay contacts complete all as specified and directed.
M&L for Overhauling and servicing of 33 KV VCB outdoor type including repair and setting of operating mechanism parts, spring charging material mechanism, well cleaning with petrol and CRC-226 and replacing unserviceable parts/ accessories, oiling/ greasing of moving parts, dismantling, checking and well cleaning of pole insulator, checking of vaccum, interupters well cleaning mechanism links fibre reinforced plastic frame around the vaccum interupts including routine and periodical test complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr width and not exc. 1.5 mtr in depth in soft/loose soil and getting out complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr width and additional 1.5 mtr or part thereof in depth beyond the first 1.5 mtr in soft/loose soil and getting out complete all as specified and as directed.
M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and directed.
Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed.
M&L fly ash bricks with (old size) locally available laid in trenches above sand cushioning for cable protection complete all as specified and directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-55 (11 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminious paint on embedded surface incl writing of Pole Numbers etc., and marking of two black/red/yellow strips with synthetic enamel paint upto 1.2 Mtr height and making good disturbed surface complete all as specified and directed.
Supply and fixing of MS Cross arms, bracings, supports,anti climbing device etc. incl nuts, bolts, washers, welding, bending, drilling inclusive of two coat aluminium paint over a coat of red oxide primer after preperation of surface complete all as specified and directed.
S&F Gang operated air breaker switch, triple pole, mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 Amps, out door type (confirming to IS specifications) HT 11 KV, triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse Assembly, Fuse carrier fitting, 9 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and directed.
Supply and fixing of lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp of rating 11 KV complete all as specified and directed.
Supply and installation of copper wound transformer step down, outdoor type complete with standard fittings, HT 11 KV 3 Phase, LT 433 volts, Level-III, IS: 1180 - (2014), 3 Phase 4 wire with off load tappings on HT side to vary secondary voltage within limit of capacity upto 160 KVA complete all as specified and directed.
S&F of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement, as directed..
M&L for galvanized earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using glavanised iron strip 25x4mm by means of bolts, nuts, check nuts and washers made of MS and protected by light grade 40mm dia and 20mm dia bore for watering and incl funnel, wire mesh RCC pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including excavation and earth work, disposal of surplus soil to a distance not exc 50 mtr) as shown on Plate No 3 of SSR Part-I 2009 complete all as specified and directed..
All as per item no.31 above but using galvanised earth lead wire 4.0mm dia as earthing lead
Supply and fixing Galvanised iron strip 25 x 4mm for connection of earthing with DBs and LT Panel etc. directly burried in ground complete all as specified and directed.
Supply and Laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 95 sq mm 3 core complete all as specified and directed.
M&L for horozontal boring and inserting casing pipe with all fitting and fixture with material of HDPE pipe size 150 mm of pressure rating 6 Kg/Cm2 along road and under pavements/hard standing/railway/road crossing in all type of soils at prescribed depth of boring not less than 1.75 Mtr from the raod surface including making PCC Chamber with cover at both ends of road complete all as specified and directed.
Supply, Laying and testing of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench as per site requirement /passing through pipe/pole complete of the following sizes and cross sectional area :- 35 Sqmm, 3.5 core
50 Sqmm, 3.5 core
185 Sqmm, 3.5 Core
S&Fof Sheet metal enclosure for MCB DB double door three pole & Neutral 4 way with 200 amps rated bus bar complete all as specified and directed.
S&Fof Isolator, 63 amps. FP, 415 volts complete all as specified and directed.
S&Fof Isolator, 40 amps. TPN, 415 volts complete all as specified and directed.
S&F of MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
M&L for Galvanised Steel Tubing Pipe 100 mm bore (dia), medium grade with fixed for riser complete all as specified and directed.
M&L Brick work with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of brick work/concrete surfaces in CM 1:4, finished fair & even & smooth without using extra cement complete all as specified and directed.
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC type D2 1:4:8 (using 40 mm graded stone aggregate) as in sub base and finishing the surface even and fair complete all as specified and directed.
M&L for 100 mm thick PCC type B1 1:2:4 (using 20 mm graded stone aggregate) as in hard standing and finish even and smooth without using extra cement complete all as specified and directed.
Excavating in post holes (or similar holes) each n. exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n. exc 50 mtr and making good surface in soft/loose soil complete all as specified and as directed.
S&F mild steel angle iron work, as in fencing post and strut, flat iron fillets for securing wire mesh etc including cutting, drilling, bending, bolting etc and similar work complete all as specified and directed.
S&F for Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted or forget into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 410-0 or 310-0, and for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts,etc complete all as specified and directed.
S&F PVC coated chain link fencing 3 mm dia galvanised wire mesh (mesh size 50 mm x 50 mm) made up to tapped wire and laid on portion/fixed on poles complete all as specifed and directed. (NOTE : MS Post, MS round bars, flat iron, nuts & bolts shall be measured and paid seperately.)
S&F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and directed.
M&L for preperation of new steel and iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
M&L for preperation of new steel and iron surfaces of any description n. exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
GEPS PROJECTS (BID ID -3168645)
Rajindera Enterprises (BID ID -3167832)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .