Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-Finance L1 | |
| 2 | L2₹19.9 L+₹7,100.35 (0.36%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹25.9 L+₹6.1 L (30.7%)Accepted-Finance | L3 | Accepted-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹26,500
Closing Date
3 Jan 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC I, Lucknow
Pareshan Bhawan Lucknow
Work
2024_UPTCL_983825_1
E-Tender35/2024-25
Open Tender
Electrical Works
Piece-work
30 days
Gomti Nagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
A/c No 2408002190005438, IFS PUNB0691100, PNB, Lko
₹26,500
1 Feb 2025
16 Dec 2024
4 Jan 2025
16 Dec 2024
3 Jan 2025
16 Dec 2024
Amount
Bus Post clamp Suitable for Twin Panther
Bus Post clamp Suitable for Twin Moose
33 kV Dop out Fuse set with post insulator
Fittings & Clamps
Supply of PG clamp duly made of LM6 aluminium alloy suitable For Moose/Moose complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample.
Supply of PG clamp duly made of LM6 aluminium alloy suitable For Moose/Panther complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample
Supply of PG clamp duly made of LM6 aluminium alloy suitable For Panther/Panther complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample.
Supply of PG clamp duly made of LM6 aluminium alloy suitable For Moose/Tarantulla complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample.
Supply of PG clamp duly made of LM6 aluminium alloy suitable For Panther/Tarantulla complete with 4 no. 16x90mm size GI nuts and bolt and spring/plain washer. As per sample.
Supply of 33KV isolator clamp made of aluminium alloy LM6 one side connecting Twin panther conductor and another side connecting with the Isolator Thimble/ plate complete with clamp HDG nut - bolts and washer as per sample
Supply of 33KV isolator clamp made of aluminium alloy LM6 one side connecting Twin Moose conductor and another side connecting with the Isolator Thimble/ plate complete with clamp HDG nut - bolts and washer as per sample
Supply of 132KV isolator clamp made of aluminium alloy LM6 one side connecting twin panther conductor and another side connecting with the Isolator Thimble/ plate complete with clamp HDG nut - bolts and washer as per sample
Supply of following Portable fire extinguishers carbon di oxide co2 type complete with hose pipe and all other accessories and fitting as per IS 2878/1986
Supply of AFFF Portable fire extinguishers mechanical foam type complete with initial charge hose pipe and all other accessories and fitting as per IS 1024 Trolley /wheel mounted 45/50 litre capacity
Supply of Dry Chemical Powder type fire Extinguisher of 4.5 KG Capacity Conforming with IS 2171/1988 as per technical specification
Supply of Sand Bucket as per technical specification
Supply of Sand Bucket stand suitable for 10 Nos. Bucket as per technical specification
Fire Wall Mounted LED Luminarie type FL-2( 250 Watt)
Supply of 150W LED Street Light as per Tech. specification.
Supply of new generation energy saving environment friendly long life versatile pressure die casting aluminium outdoor high beam flood light with high power of LED street light luminaries 150 watt of havells/CGL /any standard make. Transportation upto site, insurance etc. and any other job requested to properly execute the complete work.
Work Part-(B)
Shifting/Dragging of Main tank of 63 MVA Transformer up to 20 mtr distance including turning of the tank ,as required alongwith associated accessories from existing place to near open space/safe loading place at 132KV Substation TRT with all due care of safety & precautions.
Additional shifting of Transformer tank upto 30 mtr distance at 132KV Substation TRT (1 Job for every 5 mtr.)
Erection of 63 MVA Transformer RTCC Panel including shifting from storage place to control Room.
Safe Carriage of 20 KL Transformer oil tank for centrifuging of Transformer oil from 220 KV Substation Sarojninagar / any other UPPTCL S/S within( approx distance 60Km.) and after completion of work return the oil storage tank including loading from 132KV S/S TRT and unloading at other substation as per T/F supplier guidelines.
Performing following precommisioning CT test on all Turret CT before erection of 63 MVA T/F. A) Ratio Tests b) IR Test c) continuity Test d)Winding Resistance e)Polarity Test d) IR of CFT
Performing Pressure test using Dry Air on All Radiators @0.3 kg/cm2 with hold time 30mins for checking leakage before erection of 63MVA T/F. (b) Performing Leakage test on Air Cell using Dry Air with pressure 0.07 kg/cm2 & prssure test on conservator tank using dry air with pressure 0.5 kg/cm2 ( Air cell should not being pressurised condition ) for checking leakage before erection of 63MVA T/F . If Pressure drops leakage point to be identified and rectified. Note- Dry Air plant to be arranged by contractor.Note-Any other tests required by T/F manufacturer will be in contractors scope.
Performing precommisioning Tan Delta tests on HV & LV Bushings of transformer before erection of 63 MVA T/F using standard testing kit with valid calibration certificate. Note-Any other tests required by T/F manufacturer will be in contractors scope.
Complete erection of 63 MVA Transformer including Radiators, Conservator Tank, Bushing, Connecting pipe lines, Cooling fans and pumps, Marshaling box, OTI, WTI, Capillary pipes etc.
Filling of fresh Transformer oil from Transformer oil drums in suitable capacity oil stortage tank and then centrifuging of transformer oil by ultra high vaccum oil Filtration plant after connecting the centrifuging pipes with oil tanker to oil filtration plant including taking the BDV value of oil periodically till the required value is achieved with all cost of centrifuging machine CFM operator, lubricant etc. Note- Before Filling Oil in storage tank for centrifusing the BDV ,PPM test to be performed.
Centrifuging/Dehydration of the complete Transformer oil of 63 MVA Transformer by ultra high vacuum oil filtration plant after connecting the centrifuging pipes with Transformer tank to oil filtration plant. Including taking the BDV values of oil and megger values of the Transformer periodically till the required value is achieved. Including filling and topping up of the Transformer oil under vacuum in Main tank , Radiator , Conservator tank etc. and attending the oil leakages if any, will all cost of centrifuging machine , CFM operator , Lubricant etc.
Performing complete testing of Transformer with standard testing equipment with valid calibration certificate . Following tests are to be completed Tan-delta and capacitance measurement at standard as well as variable frequencies of 3 no. HV,03 no. IV and 03no. LV bushing (using omicron/megger kit) after erection (b) LV testing of ttransformer including magnetising current test , magnetic balance test , measurement of winding resistance test, vector group, insulation resistance, core insulation, voltage ratio test, short circuit test, open circuit test, .Test report to be compiledand submitted in required formatas per satisfaction of competent authority.Note-Any other tests required by T/F manufacturer will be in contractors scope.
Sampling & testing of transformer oil at CPRI or any other NABL testing lab including cost of transportation of sample in standard sampling bottle (adequate no. of bottle arranged by contractor) . samples to be taken at following intervals . 1 Before filling in transformer main tank & OLTC -02 samples 2. Before charging -05 samples at top & bottom of main tank & OLTC -3 samples. Following test to be Performed - 1-BDV 2)PPM 3)Tan delta 4) Resistivity 5) Interfacial tension 6) Particle count 7 ) DGA (one job for each sample Note-Any other tests required by T/F manufacturer will be in contractors scope.
Erection of auxiliary structures required for installation of Bays ALP/ABL/BBL/BCT’s etc. including shifting of all material i.e. structure parts nuts, bolts washer etc. from store to site of erection, erection of structure as per drawings and practices using flat and spring washer with each bolt. Matching of holes, cutting, matching of member if required shall also be done by the contractor without any extra cost to complete the work satisfactorily. All material to be erected shall be supplied by the UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost.
Erection of Equipments :- Erection of following equipments as per instruction manual of various equipment and technical specification including shifting of material/equipment from store to erection site including all other associated work to complete the job satisfactorily :-
145 KV C.T. with JB
145 KV Bus Isolator.
132 KV Control &Relay Panel
Laying of following sizes of unarmoured copper control cables in the cable trenches from Transformer C&R Panel to Marshling Box,132/33KV CT to CRP, equipments junction boxes, RTCC panel to DM box, Transformer to marshling box, CB to Transformer marshling box, interpanel wiring, WTI,OTI,RTD sensors, Fan & pump wiring, lighting of yard etc as per requirement & cable schedule, it's saddling with 25x3 mm Al saddle at every 750mm distance including carriage of cable drum from store to site and shifting back to store and all other associated works to complete the job satisfactory as per technical specification.
10 x 2.5sqmm unarmoured copper control cable
6 x 2.5sqmm unarmoured copper control cable
4 x 2.5sqmm unarmoured copper control cable
2 x 2.5sqmm unarmoured copper control cable
Earthing of main tank of the Transformer, RTCC Panel, Marshalling box, drive mechanism of the cooling fans etc.of 63 MVA Transformer with the help of 50 x 6 mm / 75 x 10 mm size M S flat (to be provided by Department), its jointing with already laid earthmat and necessary modification in existing support for earthing of Neutral bushing and then painting of earthing strips as per technical specification/ standard practices .
Earthing of Transformer HV & LV neutral with 50 x 6 mm / 75 x 10 mm size M S flats , connecting with delta including making additional delta at two places and other associated work as per technical specifications.the Neutral Earthing of Transformer is to be connected with 2 MS flat of size-75x10mm strips and these strips shall be connected with the earth electrode system at X & Y-axis of Main Earth mat of s/s for appropriate protection of 63MVA T/F.
Carriage of sub-station structure through private truck from EFU Naini (Allahabad) to above sub-stations alongwith sorting, shifting and loading at Naini and unloading and stacking at 132 KV Substation TRT, Lucknow
Sorting out and stacking of main & auxilary structure as per BOM at EFU Naini (Allahabad)
Loading of structure on Pvt. Truck / trailer at EFU Naini.
Transportation of structure from EFU Naini, Allahabad to sub-stations
Unloading and proper stacking of structure parts at Sub-stations
Laying MS flat for Earthing of Structures/equipments by cutting,. bending , laying 700mm below ground level as per Corporation norms in the following way: Double earthing of all structure and equipments. One earthing will be from top and another from bottom by 50x6mm/75x10mm MS Flat to be provided by dept. free of cost.Work includes excavation and backfilling of soil
25x6mm. MS Flat
50x6mm. MS Flat
75x10mm. MS Flat
Painting of newly erected MS Flat following with 01 coat red oxide and 02 coat with bus green ISI mark paint complete with its MS Flat & vertical support.
MS Flat 50x6 mm
MS Flat 75x10mm
MS Flat 25x6mm
Jumpering interconnection of equipments through various ACSR conductor of various 132kv equipments (CT/PI/CB/LA/ISO/Bushing etc.) with Main bus of ACSR Moose / Twin Moose conductor.The work includes cutting of conductor ,bending in proper shape ,clamping with help of clamps and other associated work to complete job satisfactorily.(1 job includes 3 phases jumper)
63MVA T/F Bay of 132kV/HV side through Panther conductor
63MVA T/F Bay of 33kV/LV side through Twin Moose conductor
Raising of height of jumpers between Transformer LV Side Bushing and LA by installation of 33kV Post Insulator increasing the height by adding upper angle joints duly fabricated using scrap angles to the auxialary structure availabe at sub station store by direction of JE/SDO.
Providing and fixing of Protective MS Iron Mesh/ Jali of size (3x3mtr approx) on both side of 63MVA T/f (HV &LV) to protect Radiators from any damage.Work includes proper grouting of MS angle support stand/structure adjustable to radiator height. (01 Job for each side)
Supply and fixing of junction box on gantry structure of size 200mmx200x150mm made of MS sheet of 16 gauge duly powder coated in side fixing 1no. 6amp MCB ,1no. TB of 1no. terminal, and 1no. 16amp fuse fixed on MICA sheet and back side MS clampalong with PVC pipe fixing on junction box.half round GI PIPE OD 50mm for mounting the 120/150watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
Supply and fixing of half round GI PIPE OD 50mm for mounting the 120/150 watt LED light upon gantry mounting of 02no. Bracket upon gantry and fixing GI pipe complete with Nut & bolts and washer.
Construction of 02 nos. fire hut of size 4000 x 3000 x 2000 mm duly made of GI angle post supports & frame structure covered by 1.5 mm corrugated fiber glass (A.C.) roofing sheet and B.C. platform as per technical specifications with all cost of men, materials, misc. comsumables and T & P etc. required for the job at 132 kV S/S TRT as per details given below:-
Grouting of 04 Nos. 50 x 50 x 6 mm GI angle posts of height 2500 mm grouted upto 500 mm depth with CC mixture in the ratio of 1:2:4. Fabrication, fixing & welding of open hut type GI angle frame structure of size 4000 x 3000 x 2000 mm on above grouted GI angle posts by due cutting,drilling and welding of GI angles of size 50 x 50 x 6 mm which shall be provided by the department.
Fixing & fitting of 1.5 mm red colour corrugated fiber glass (A.C.) roofing sheet to cover the roof of open hut type GI angle frame structure of size 4000 x 3000 x 2000 mm with 'J' hooks,nuts,bolts and washer etc. for each fire hut including fixing of the ridge cap at the top of the open joint of the roof sheet for preventing of seepage of rain water.The joints shall be sealed properly to make them water proof using necassary sealant materials.
Construction of B.C. floor / platform of size 4000 x 3000 x 200 mm for each fire hut with first class brick ballast,cement & sand mixture in the ratio of 1:4:8 and finally 12 mm thick plastering with cement & sand mixture in the ratio of 1:4 including necessary curing etc.
Fixing of 02 nos. MS BP sheet board of size 300 x 150 mm in the angle frame structure of each fire hut after due fabrication by cutting,drilling,welding etc. of MS BP sheet including painting of above angle post & frame structures with post office red colour synthetic enamel paint of standard quality in two coats after applying one coat of red oxide primer and writing 'आग ' and 'FIRE' on the MS sheet boards. (01 Job for each fire hut)
Shifting of dismalted/damaged/new materials lying in approach road/erection location for 63MVA T/F .Work includes Loading, , unloading and proper stacking of following structure and Scrap/ Miscellaneous 132/33 KV equipments and materials from different locations of switchyard to store and open yard store at 132 KV Substation TRT,Lucknow using Hydra/ Manpower to create space for T/F and clear road for 63MVA T/F .
Oil drum
Conductors drum
Conductors old used in pices.
Various size of Structure
132kV CB / 33kV CB
132KV CT/ PT
Temporary shed
Dismentaling of Equipments :- Dismentaling/Disconnection of following equipments as per instruction manual of various equipment and technical specification including shifting of material/equipment from dismentaling site to store site including all other associated work to complete the job satisfactorily :-
Opening of old & existing jumpers of ACSR Panther conductor from main bus to station transformer on station transformer bay (1 job includes 3 phases jumper)
Dismentaling of 33/0.4kV 25KVA Station T/F
Dismentaling of ABL structure alongwith 33 kV Fuse set with post insulator
Dismentaling of 33 KV BI
Safe shifting & Erection of following equipments as per instruction manual of various equipment and technical specification including shifting of material/equipment from store to erection site including all other associated work to complete the job satisfactorily :-
ABL structure alongwith 33 kV Fuse set with post insulator
33/0.4kV 25KVA Station T/F
Laying of 3.5x300 sq. mm LT power cable, 50 cm from the ground level after due excavation of the trench and covering the cable with sand and bricks between the station T/F and the start of concrete trench including drilling into the existing trench
Termination of 3.5x300 sq. mm LT power cable as laid above including making necessary holes in gland plates as per requirement and providing and fixing crimping type lugs of Dowell/Tension make for termination of each core of the cable at both ends including providing of lugs and accessories and welding holes if required (01 Job for each end of the cable)
Transportation of 3.5x300 sq. mm LT power cable drum from any transmission substation/ stores to 132kV S/S TRT including shifting, loading, carriage, unloading and shifting of the cable to the work site
Installation of cable joint in 3.5x300 sq. mm LT power cable at 01 location , if required, including supply of jointing materials and accessories.
MANAS ELECTRICALS (BID ID -4829320)
Perfect Power Transformer Associates (BID ID -4829365)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .