Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹24.4 LAccepted-AOC GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L 1 | Accepted-AOC Being L 1 | |
| 2 | L-2₹26.7 L+₹2.3 L (9.33%)Rejected-Finance DEPOPARA PO BINNAGURI PS BANARHAT DIST JALPAIGURI WEST BENGAL PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹28.2 L+₹3.7 L (15.3%)Rejected-Finance NIL | L-3 | Rejected-Finance Being L 3 | |
| 4 | L-4₹28.3 L+₹3.8 L (15.6%)Rejected-Finance P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-4 | Rejected-Finance Being L 4 | |
| 5 | L-5₹28.9 L+₹4.5 L (18.3%)Rejected-Finance NEAR KRIPAN TCP GATE PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L-5 | Rejected-Finance Being L 5 |
Tender Value
₹33.6 L
EMD Value
₹67,200
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Binnaguri
Post Binnaguri Dist Jalpaiguri West Bengal
PROVISION OF STEEL TUBULAR POLE LED SECURITY AND STREET LIGHTS AT BINNAGURI UNDER GE NORTH BINNAGURI
2022_MES_533400_1
NIT No. 8701/ 20/ 2022-2023 / 03 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
BINNAGURI
Class D Category b i
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹67,200
Yes
23 Aug 2022
24 Jun 2022
29 Jul 2022
24 Jun 2022
27 Jul 2022
7 Jul 2022
60 days
Amount
SCHEDULE `A' ( ELECTRIFICATION) Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exceeding 3 m wide and not exceeding 3 m in depth for foundations of poles etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .
Material and labour for laying well burnt old size bricks, fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 50 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers as in cable protection complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Material and labour for plain cement concrete 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundations/mass concrete for pole foundation and finishing the surface ecven & smooth withouit using extra cement including necessary form work complete all as specified.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in foundations/mass concrete for pole foundation/ coping / pedestal of poles and stay and finishing the surface ecven & smooth withouit using extra cement including necessary form work complete all as specified.
Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-31, 9 meter long including painting all external exposed steel surfaces with two coats of aliminium paints over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bitumenous paint complete all as specified and as directed.
Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-55, 11 meter long including painting all external exposed steel surfaces with two coats of aliminium paints over a coat of red oxide zinc chrome primer and all internal surfaces and external surfaces in contact with concrete with two coats of black bitumenous paint complete all as specified and as directed.
Supply and fixed of LED flood light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 11500 lumen, system wattage 100 Watt, Ingress protection IP-66 with all acessories including testing , necessary connection complete all as specified and directed.
Material and labour of LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 6600 lumen, system wattage 60 Watt, Ingress protection IP-66 with all acessories complete all as specified and directed.
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 35 sqmm 3.5 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 16 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block clamps nuts bolts washers and pipe shall be measured and paid separately under appropriate items)
Supplying and fixing of single run, 3 core, 2.5 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting complete all as specified.
Supplying and fixing of single run, 2 core, 1.5 sqmm nominal cross sectional area multistranded copper conductor cable, over all PVC sheathed, 1100 Volts grade confirming to IS-694-2010 (FRLS) heavy duty cable PVC insulated and PVC sheathed from pole junction box to light fitting complete all as specified.
Supply and fixed of 20 mm nominal bore dia, UPVC pipes of pressure rating 10 kgf/cm2 fixed to pole, any type including provision MS clamp of size 20mm x 3mm flat at interval of 1.5 m length and painting with synthetic enemal complete all as specified and as directed
Supply and fixing of street light bracket made out of mild steel angle of size 50 mm x 50 mm x 5mm by cutting, welding and well finishing including MS clamp of flat iron complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing of street light bracket made out of GI pipe light grade 40 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.5 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supplying and fixing of MCCB, 63 Amps, Four pole, adjustable, 415 Volts, 25 kA, 50 Hz Icu=100% including connecting, testing and commissioning MCCB in panels etc. complete all as specified and directed
Supply and fixed of powder coated Mild steel junction box of size 250 mm x 190 mm x 150 mm, out door type, weather proof, factory made out of CRCA sheet 2.00 mm thick CPRI Approved with front openable hinged door having rubber lining, painting internally and externally with powder coated locking arrangements with 4 Nos copper bus bars , 100 Amps, mounted on porcelain insulator, glands and lugs etc. including one No MCB SP, 6 Amps, 10 kA, fixed on insulator and fixed on box in DIN rail , fix to pole with suitable size of FI clamps, nuts , bolts and washers complete and including making good surface of existing surface and connections complete all as specified. Note : Rate quoted against the item will include for making suitable nitch and making good disturbed surfaces with using required PCC 1:2:4 type B0 / 15 mm thick rendering in cement mortar (1:4)
Supply, fabrication , installation, testing and commissioning of LT 3 phase 4 wire 450 volts system factory made water and vermin proof protection pedestal type out door type cubical feeder pillar box of size (900 mm (H) x 600 mm (B) x 400 mm (D)) overall made out of 3.15 mm thick CRCA and frames and legs made out of MS angle section 40x40x6 mm in all sides with double door, front and back openablewith hinged door and air ventilation arrangement including provision of cable looping box of size 1000 x 450 x 400mm CPRI approved degree of protection IP-55 and general construction confirming to IS; 13947 on PCC 1:2:4 type B-1 platform of size 0.80m x 0.60m x1.05 m depth (60 cm above the ground level and 45 cm below the ground level), frame factory fabricated with front and back openable double door system (Each door hinged with body at 4 places ) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process which included seven tank pretreatment process comprising of degreasing, rinsing, de-rusting, rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns , provided with suitable gasket to make it dust / vermin proof and general construction confirming to IS:8623/93. the TPN copper busbar shall be insulated with colour coaded heat shrinkable sleeve through out length of the busbar and shall be mounted on suitable size "F"class insulator at an interval not more than 250 mm. the cubicle incomer MCCB as well as outgoing shall have copper TPN extansion links of current carrying capacity not less than 1.5 times the rated capacity of individual feeder. the extansion capacity not less than 300 mm long supported on suitable size "F"class insulator. all inter connection between the main busbar as well as outgoing feeder shall be carried out with TPN copper busbar of rating not less than 1.5 times rated capacity of individual outgoing feeders & should be insulated with heat shrinkable PVC sleeves, Danger Notice Board size as per IE Rule 1956 . All control wires shall be of 2.5 sqmm multi stranded copper conductor and shall be properly bunched, tied , ferulled for proper identification and print with adequate size of lugs complete including PCC foundation comprising of the following. (a) Incomming TPN copper busbar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (b) Outgoing TPN copper busbar 100 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size "F" class insulators of non hygroscopic non combustable , all internal connection from main busbar to switch gear etc - 04 Nos (c) Incoming MCB FP 63 Amps 10 KA 415 volts, 50 Hz, withadjustable thermal magneti c release with Icu = 100 % Icu, neutral adjustmnet 100 % including all fixing accessories with both ends spreader links - 01 No (d) Outgoing MCB SP 16 Amps 10 KA 415 volts, 50 Hz, - 05 Nos (e) Outgoing ML connector TPN 32 Amps -01 No. (f) MCB SPN 40 Amps , 240 Volts 10 kA - 4 NOs (g) Digital timer single phase with necessary control wiring - 01 No (h) Spare pocket for 1No MCB. (j) Enameled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200mm x 150mm, white with letters, figure and conventional skull and bones in signel red and fixed with nuts and bolts on door / shutter of FPBfor LT - 01 No NOTE: Rate of earthwork and PCC are deemed to be inclusive in the unit rate quoted against this item. (ii) The schematic diagram of LT panel shall be got approved by GE before procurement.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 20 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- (i) Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. (ii) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply and fixing of Time lite distribution board with in sheet steel enclouser of capacity 65 Amp comprising of 3 pole 65 Amp power contactor with coil voltage 415 Volt AC, MCB TPN 63 Amp 10 KA, Analog time switch and togle switch two way for manual and auto operation with and including internal connection with suitable size copper conductor wire complete all as specified and directed.
M/S MOHAN KUMAR BANSAL
SHRI PRADEEP PARIK
BBKundu
R K AGARWAL
samrat saw mill and joinery workshop
M/s. MD IRSHAD
M/S SINHA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .