Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | ₹15.0 L Quoted ₹15.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.7 L+₹2.4 L (15.7%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | ₹17.7 L+₹2.4 L (15.7%) | L2 | Rejected-Finance Other Than L1 |
| 3 | L3₹22.1 L+₹6.8 L (44.3%)Rejected-Finance | ₹22.1 L+₹6.8 L (44.3%) | L3 | Rejected-Finance Other Than L1 |
| 4 | Rejected-Technical 143 SANT NAGAR AIR FORCE GATE IZZAT NAGAR BAREILLY UP 243022 | 243022 | - | - | Rejected-Technical Not enlisted in b(ii) Catogery |
Tender Value
₹21.8 L
EMD Value
₹43,500
Closing Date
10 May 2025, 6:00 pmClosed
CWE(AF) BAREILLY
HQ CWE(AF) BAREILLY PIN-243002
SPECIAL REPAIRREPLACEMENT OF DEFECTIVE PARTS OF RING MAIN UNIT (RMU) ALONGWITH ASSOCIATED WORKS AT MES INSTALLATIONS AT AF STATION BAREILLY
2025_MES_703946_1
81512/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) BAREILLY
AS Per NIT
9 documents required · 9 mandatory
₹500
GE (AF) BAREILLY
₹43,500
Yes
22 Jul 2025
9 Apr 2025
12 May 2025
9 Apr 2025
10 May 2025
23 Apr 2025
9 Apr 2025 - 19 Apr 2025
Amount
Opening the front and rear cabinate of the RMU 6 way 630 Amps 11 KV de-carbonizing moving and fixed contacts if required, lubricating, checking the pressure of SF-6 gas, inspecting the wiring of micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system complete and placing the SF-6 VCB and isolating unit in its original position complete all as specified and directed.
M&L for replacement of plug in type voltage presence indicator system (VPIS) type WIM for 11 KV, RMU complete all as specified.
Supply, installalation, commissioning and, testing of Spring charge motor 24V DC operated with AC and DC mechanism suitable for 11 KV RMU and connecting with existing system all as specified and directed.
Supply and connecting VCB Charging rod on existing system suitable for 11 KV RMU all as specified and directed.
Supply and connecting charging lock gear suitable for 11 KV RMU all as specified and directed.
S&F spring charging lock lever suitable for 11 KV RMU all as specified and directed.
Supply and installation power bank unit 24 Volts and connecting with existing system incuding fixing required copper flexible cable of suitable size all as specified and directed.
S&F LED Kit suitable for 11 KV RMU all as specified and directed.
S&F indicator suitable for 11 KV RMU all as specified and directed.
S&F CRC suitable for 11 KV RMU all as specified and directed.
M&L for filling SF 6 Gas on existing system and testing the required level all as specified and directed.
M&L for replacement of pressure indicator manometer for SF-6 Ring Main unit 11 KV by opening the front cover complete all as specified and directed.
M&L for replacement of ring type current transformer 100/1 Amps for SF-6 Ring Main unit 11 KV by opening the cable compartment cover of fixed the CT on cable elbow plug/T plug complete .
M&L for replacement of Trifurcation boot 11 KV capacity for cable termination joint of RMU incoming and outgoing terminals including taking out old defective trifurcation boot complete
S&F short circuit indicator relay of SF-6 Ring main unit type ALPHAE/VOIS relay complete
S&F in replacement of cable sealed for SF-6 Ring main unit 11 KV complete all as specified and directed.
S&F in replacement of HT bushing with gaskit for SF-6 Ring main unit 11 KV complete all as specified and directed.
S&F in replacement of digital Voltmeter (0 to 500V ) complete all as specified and directed.
M&L cable jointing kit for 11 KV ( E) grade cable for inddor end termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core complete all as specified and directed.
M&L for hammer tone spray painting of 11 KV RMU inddor type of capacity 630 KVA by scraping with emery paper and making free from rust, dust and applying one coat of syenthetic enamel paint and two coat of smoke gray paint through spray including writing MES number and machine number with black paint, letters 15mm wide and 50mm height complete all as specified and directed.
M&L for replacement of Amp meter 0 to 600 Amp complete all as specified and directed.
Disconnecting LT supply and taking out defective LT ACB of any make and rating and serving by cleaning the fix and moving parts, removing dust particle by using high speed blower applying greese/jelly to moving mechanism and moving parts , tightening complete all as specified and directed.
M&L for repalcement of earth fault relay for 6 NO + 6 NC with wiring bunch for 4 pole breaker complete all as specified and directed.
M&L for repalcement of shunt trip and closing coil 6D-16D/06 N-20S complete all as specidied and directed.
M&L for replacement of trip indication switch complete all as specified and directed.
M&L for replacement of Spring charged indication switch complete all as specified and directed.
M& L for repalcement of Position indication switch complete all as specified and diretced,.
M&L for repalcement of castle key lock - 4 pole complete all as specified and directed,.
M&L for repalcement of charging motor 220V AC/DC , 6D-16D/06N-20S complete all as specified and directed,
M&L for repalcement of Magnet hold trigger 30D-40D, 4 pole complete all as specified and directed.,
S&F in replacement of 6 way secondary isolating contact block
S&F in replacement of lockable trip push button type A
S&F in replacement of Arch Chutes for 400/800A breaker
S&F in replacement of auxillary contact block 6 Nos+6NC
S&F in replacement moving arching contact for 800 to 1250A breaker
Supply, installation, testing and commissioning of air circuit breaker (ACB) draw out type of capacity 4 pole, 1250 Amp breaking capacity 50 KA including taking out old unserviceable and necessary connections complete all as specified and directed
Supply,laying, jointed and testing HT cable XLPE insulated, screened, PVC bedded, galvanised steel strip, armoured,electric power cables with aluminium conductor, 11000 volts (Earthed) grade, laid in trenches/ drawn through pipe/ poles or laid under road / drains / path complete of cross sectional area 95 sq. mm 3 core complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc or /getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cables with 8 CM thick before laying of cables and 15 CM thick after laying and stretching of Cable complete all as specified and directed. Note : Only punned thickness i.e. 18 CM shall be measured and paid.
Supply and laying reinforced precast concerete cable cover, class HV type 1 flat size 300mm x 180 mm x 40 complete all as specified and directed
Vishal Traders (BID ID -3289275)
Hindustan Power Corporation (BID ID -3292453)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .